Interlogix NS2052-8P-2C User Manual

NS2052-8P-2C Industrial PoE+ Switch User Manual
P/N 1073392-EN • REV A • ISS 07FEB18
Copyright
©
2018 United Technologies Corporation.
Interlogix is part of UTC
Climate, Controls & Security, a unit of United
Technologies Corporation
. All rights reserved.
Trademarks and
patents
Trade names used in this document may be trademarks or registered trademarks of the
manufacturers or vendors of the respective products.
Manufacturer
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626
-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
Version
This document applies to
NS2052-8P-2C.
FCC compliance
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC compliance
Class A:
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated i
n a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this
equipment
in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
Canada
This Class A digital apparatus complies with CAN ICES
-003 (A)/NMB-
3 (A).
Cet appareil numérique
de la classe A est conforme à la norme CAN ICES-
003 (A)/NMB
-3 (A).
ACMA compliance
Notice!
This is a Class A product. In a domestic environment this product
may cause radio interference in which case the user may be required to take adequate measures.
Certification
EU directives
This product and
- if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19
/EU (WEEE directive): Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equi
pment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info.
Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCL
UDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS
.
For more information on warranty disclaimers and prod
uct safety
information, please check
www.firesecurityproducts.com/policy/product-
warning/
or scan the following code:
Contact information
and manuals
For contact information go to:
www.interlogix.com or
www.firesecurityproducts.com
.
To get translations for this and other product manuals go to: www.firesecurityproducts.com
.
Content
Important information 2
Chapter 1 Package contents 3
Package contents 3
Chapter 2 Hardware introduction 4
Physical dimensions 4 Product features 9 Product specifications 10
Chapter 3 Installation 13
DIN-rail mounting 13 Wall mount plate mounting 15
Installing the SFP transceiver 15
Chapter 4 Troubleshooting 18
Appendix A Networking connection 19
Appendix B Approved Interlogix SFP transceivers 22
NS2052-8P-2C Industrial PoE+ Switch User Manual 1
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be liable for any lost profits or business opportunities, loss of use, business interruption, loss of data, or any other indirect, special, incidental, or consequential damages under any theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you. In any event the total liability of UTCFS shall not exceed the purchase price of the product. The foregoing limitation will apply to the maximum extent permitted by applicable law, regardless of whether UTCFS has been advised of the possibility of such damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you should read.
2 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 1
Package contents
The description of the IFS NS2052-8P-2C model is as follows:
Industrial 8-port 10/100TX 802.3at PoE+
+ 2-port TP/SFP combo Ethernet switch
Unless specified, the term industrial PoE+ switchmentioned in this user manual refers to the NS2052-8P-2C.
Package contents
Open the box of the industrial PoE+ switch and carefully unpack it. The box should contain the following items:
The industrial PoE+ switch × 1
CD with user manual × 1
DIN rail kit x 1
Wall mounting kit x 1
If any of these are missing or damaged, contact your dealer immediately. If possible, retain the carton including the original packing materials for repacking the product in case there is a need to return it to us for repair.
3 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 2
Hardware introduction
Physical dimensions
Dimensions (W x D x H): 161 x 107 x 72 mm
4 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 2: Hardware introduction
Front panel
Fast Ethernet TP interfaces (port 1 to port 8)
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit TP interfaces (port 9 to port 10 TP/SFP combo interfaces)
10/100/1000BASE-T copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit SFP slots (port 9 to port 10 TP/SFP combo interfaces)
1000BASE-SX/LX mini-GBIC slot, SFP (Small-form Factor Pluggable) transceiver module: From 550 meters (multi-mode fiber) and to 10/20/30/40/50/70/120 kilometers (single-mode fiber).
NS2052-8P-2C Industrial PoE+ Switch User Manual 5
Chapter 2: Hardware introduction
DIP switch
The industrial PoE+ switch has a built-in solid DIP switch that provides “Standard” and “Extend” operation modes. The industrial PoE+ switch operates as a normal IEEE
802.af/at PoE+ Switch in the “Standard” operation mode.
In the “Extend” operation mode, the industrial PoE+ switch operates on a per-port basis at 10 Mbps full duplex operation but can support 30 W PoE power output over a
distance of up to 250 meters, overcoming the 100 m limit on Ethernet UTP cable. With this brand-new feature, the industrial PoE+ switch provides an additional solution for
802.3af/at PoE+ distance extension.
LED indicators
The front panel LEDs indicate port link status, data activity, and system power.
picture
System
LED
Color Function
P
1 Green Lit: indicates that the power input 1 has power.
P
2 Green Lit: indicates that the power input 2 has power.
F
ault Red Lit: indicates that either power 1 or power 2 has no power.
6 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 2: Hardware introduction
Per 802.3at PoE+ 10/100BASE-TX interface (port 1 to port 8)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 10 Mbps or 100 Mbps.
Blinking: indicates that the switch is actively sending or receiving data over that port.
PoE In-use Orange Lit: indicates the port is providing DC in-line power.
Off: indicates that the connected device is not a PoE
powered device (PD).
Per 10/100/1000BASE-T interface (shared with port 9 to port 10)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 10/100/1000 Mbps.
Blinking: indicates that the switch is actively sending or receiving data over that port.
1000 Orange Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Off: indicates that the link through that port has successfully connected to the network at 10/100 Mbps.
Per 1000X SFP slot (shared with port 9 to port 10)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Blinking: indicates that the switch is actively sending or receiving data over that port.
1000 Orange Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Off: indicates that the link through that port is not established.
Switch upper panel
The upper panel of the industrial PoE+ switch consists of one terminal block connector within two DC power inputs.
NS2052-8P-2C Industrial PoE+ Switch User Manual 7
Chapter 2: Hardware introduction
Wiring the power inputs
The 6-contact terminal block connector on the top panel of Industrial PoE+ switch is used for two DC redundant power inputs. Follow the steps below to insert the power
wire.
Caution: When performing any of the procedures like inserting the wires or tightening
the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
1. Insert positive/negative DC power wires into contacts 1 and 2 for DC Power 1, or 5 and 6 for DC Power 2.
2. Tighten the wire-clamp screws to prevent the wires from loosening.
8 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 2: Hardware introduction
1 2 3 4 5 6 Power 1
Fault
Power 2
+ - +
-
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. The DC power input range is 48 to 56 VDC.
Wiring the fault alarm contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the industrial PoE+ switch detects the fault status of the power failure and then forms an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts. Wires are inserted into the fault
alarm contacts.
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. Alarm relay circuits accept uo to 30 V, max. 3 A currents.
Product features
Physical port
Eight 10/100BASE-T Fast Ethernet RJ45 copper ports with IEEE 802.3at/af PoE+ injector (port 1 to port 8).
NS2052-8P-2C Industrial PoE+ Switch User Manual 9
Chapter 2: Hardware introduction
Two 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (port 9 and port 10).
Two 100/1000BASE-X mini-GBIC/SFP slots for SFP type auto detection (port 9 and
port 10).
Power over Ethernet
Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE.
Backward compatible with IEEE 802.3af Power over Ethernet.
Up to 8 ports of IEEE 802.3af/IEEE 802.3at devices powered.
Supports PoE power up to 30 W for each PoE port.
• 240 W PoE budget
• Auto detects powered device (PD).
Circuit protection prevents power interference between ports.
• Remote power feeding up to 100 meters.
Industrial case and installation
IP30 aluminum case
• DIN-rail and wall-mount design
• 48 to 56 VDC redundant power with polarity reverse protect function.
• Supports Ethernet ESD protection for 6000 VDC
• -40 to 75°C operating temperature
Switching
• Hardware-based 10/100 Mbps (half/full duplex), 1000 Mbps (full duplex), auto- negotiation and auto MDI/MDI-X.
Features Store-and-Forward mode with wire-speed filtering and forwarding rates.
IEEE 802.3x flow control for full duplex operation and back pressure for half duplex
operation.
• 16K MAC address table size
• 10K jumbo frame
• IEEE 802.1Q VLAN transparency
• Hardware DIP switch for “Standard” and “Extend” mode selection; the “Extend” mode features 30 W PoE transmit distance of 250 m at a speed of 10 Mbps.
Automatic address learning and address aging
• Supports CSMA/CD protocol
Product specifications
10 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 2: Hardware introduction
Hardware Specification
s
Fast Ethernet
Copper Ports
Eight
10/100BASE-TX RJ45 auto-MDI/MDI-X ports (port 1 to port 8)
Gigabit Ethernet
Copper
Ports
Two 10/100/1000BASE
-T RJ45 auto-MDI/MDI-X ports (shared with port 9 and
port 10)
SFP
/mini-GBIC Slots
Two 1000BASE
-SR/LX/BX SFP interfaces (shared with port 9 and port 10)
PoE
Injector Port
Eight ports with 802.3af/8
02.3at PoE+ injector function (port 1 to port 8)
Switch Architecture
Store
-and-Forward
Switch
Fabric
5.6
Gbps / non-blocking
Throughput
4.1
Mpps @ 64 bytes
MAC
Address Table
16
K entries
Share
d Data Buffer
4
Mbits
Flow Control
IEEE 802.3x
pause frame for full-duplex
Back pressure for
half-duplex
Jumbo Frame
10
K bytes
DIP Switch (Port 1 to Port 8)
Standard mode: 30 W PoE transmit distance of 100 m at speed of 10/100
Mbps.
Extend mode: 30 W PoE transmit
distance of 250 m at speed of 10 Mbps.
Enclosure
IP30 aluminum case
Installation
DIN rail kit and wall
-mount kit
Connector
Removable 6
-pin terminal block for power input.
Pin 1/2 for Power 1
Pin 3/4 for fault alarm
Pin 5/6 for Power 2
Alarm
One relay output for power failure. Alarm relay current carry ability:
1A @ 24
VDC
LED
System
and power:
DC power 1 (Green)
DC power 2 (Green)
Power fault Alarm (Red)
P
oE Copper Ports (Port 1 to Port 8):
10/100 Mbps LNK/ACT (Green)
PoE-in-Use (Orange)
10/100/1000T Copper
Ports (Port 9 to Port 10):
LNK/ACT (Green)
1000 (Orange)
Mini
-GBIC Interface (Port 9 to Port 10):
LNK/ACT (Green)
1000 (Orange)
Power Requirement
48 to
56 VDC, 5.5 A (max.), (>51 VDC for PoE+ output recommended)
Power
19 W, 64 BTU (Standby without PoE function) at DC 56 V power input.
NS2052-8P-2C Industrial PoE+ Switch User Manual 11
Chapter 2: Hardware introduction
Consumption/Dissipation
23 W, 78 BTU (Full loading without PoE function) at DC 56 V power input.
244 W, 832 BTU (Full loading with PoE function) at DC 56 V power input.
ESD Protection
6K VDC
Dimensions
(W x D x H)
72 x 107 x 161 mm
Weight
1.034 kg
Power over Ethernet
PoE Standard
IEEE 8
02.3at Power over Ethernet Plus/PSE
PoE Power Supply Type
End
-span
PoE Power Output
IEEE 802.3af Standard
Per port 48~51 VDC (depending on the power supply), max. 15.4 W.
IEEE 802.3at Standard
Per port 51~56 VDC (depending on the power supply), max. 30 W.
Power Pin Assignment
1/2(
-), 3/6(+)
PoE Power Budget
Dual power input:
240 W maximum (depending on power input)
Max.
Number of Class 2 PDs 8
Max. Number of Class 3 PDs
8
Max. Number of Class 4 PDs
8
Standards Conformance
Regulation Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC 60068
-2-32 (free fall)
IEC 60068
-2-27 (shock)
IEC 60068
-2-6 (vibration)
Standards Compliance
IEEE 802.3 10BASE
-T
IEEE 802.3u 100BASE
-TX
IEEE 802.3ab Gigabit 1000BASE
-T
IEEE 802.3z Gigabit SX/LX
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
Environment
Operating
Temperature:
-40 to 75°C
Relative Humidity:
5 to 95% (non-condensing)
Storage
Temperature:
-40 to 85°C
Relative Humidity:
5 to 95% (non-condensing)
12 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 3
Installation
This section describes how to install and make connections to the industrial PoE+ switch. Read the following topics and perform the procedures in the order presented.
Note: The images in the following installation instructions are provided for reference.
The device shown is not the industrial PoE+ switch.
DIN-rail mounting
There are two methods to install the industrial industrial PoE+ switch: DIN-rail mounting and wall-mount plate mounting. Please read the following topics and perform the procedures in the order presented.
Note: Follow all the DIN-rail installation steps as shown in the example.
To install the DIN rails on the industrial PoE+ switch:
1. Screw the DIN-rail onto the industrial PoE+ switch.
2. Carefully slide the DIN-rail into the track.
NS2052-8P-2C Industrial PoE+ Switch User Manual 13
Chapter 3: Installation
3. Ensure that the DIN-rail is tightly attached to the track.
To remove the industrial PoE+ switch from the track:
Carefully remove the DIN-rail from the track.
14 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 3: Installation
Wall mount plate mounting
Note: Follow all the wall mount plate installation steps as shown in the example.
To install the industrial PoE+ switch on the wall:
1. Remove the DIN-rail from the industrial PoE+ switch. Use the screwdriver to loosen the screws to remove the DIN-rail.
2. Place the wall-mount plate on the rear panel of the industrial PoE+ switch.
3. Use the screwdriver to screw the wall mount plate onto the industrial PoE+ switch.
4. Use the hook holes at the corners of the wall mount plate to hang the industrial PoE+ switch on the wall.
5. To remove the wall mount plate, reverse the steps above.
Installing the SFP transceiver
SFP transceivers are hot-pluggable and hot-swappable. They can be plugged in and removed to/from any SFP port without having to power down the industrial PoE+ switch (see below).
NS2052-8P-2C Industrial PoE+ Switch User Manual 15
Chapter 3: Installation
Before connecting to other network devices:
1. Make sure both sides of the SFP transceiver are with the same media type. For example, 1000BASE-SX to 1000BASE-SX, 1000BASE-LX to 1000BASE-LX.
2. Check if the fiber-optic cable type matches the SFP transceiver requirement.
To connect to 1000BASE-SX SFP transceiver, use the multi-mode fiber cable
with one side being male duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, use the single-mode fiber cable
with one side being male duplex LC connector type.
To connect the fiber cable:
1. Attach the duplex LC connector on the network cable to the SFP/SFP+ transceiver.
2. Connect the other end of the cable to a device with the SFP/SFP+ transceiver installed.
3. Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the industrial PoE+ switch. Ensure that the SFP/SFP+ transceiver is operating correctly.
4. Check the link mode of the SFP port if the link fails.
Note: We recommend the use of Interlogix SFPs on the industrial PoE+switch. If you
insert an SFP transceiver that is not supported, the industrial PoE+switch will not recognize it.
To remove the transceiver module:
1. Make sure there is no network activity by checking with the network administrator. Or, through the management interface of the switch/converter (if available), disable the port in advance.
16 NS2052-8P-2C Industrial PoE+ Switch User Manual
Chapter 3: Installation
2. Carefully remove the fiber optic cable.
3. Turn the lever of the transceiver module to a horizontal position.
4. Pull out the module gently through the lever.
Note: Never pull out the module without making use of the lever or the push bolts on
the module. Removing the module with force could damage the module and the SFP/SFP+ module slot of the industrial PoE+ switch.
NS2052-8P-2C Industrial PoE+ Switch User Manual 17
Chapter 4
Troubleshooting
This chapter contains information to help you solve issues. If the industrial PoE+ switch is not functioning properly, ensure that it was set up according to the instructions in this manual.
Issue
Solution
The l
ink LED does not illuminate Check the cable connection.
T
he industrial PoE+ switch doesn't connect to
the network
1. Check the LNK/ACT LED on the industrial
PoE+ switch.
2. Try another port on the industrial PoE+ switch.
3. Make sure the cable is installed properly.
4. Make sure the cable is the right type.
5. Turn off the power. After a while, turn on power again.
The port link LED illuminates
, but the traffic is
irregular
Check that the attached device is not set to dedicated full duplex. Some devices use a physical or software switch to change duplex modes. Auto-
negotiation may not recognize this
type of full-duplex setting.
The industrial PoE+ switch doesn’t connect to the network.
Check each port LED on the industrial PoE+ switch. Try another port. Make sure the cable is
installed properly and the right type. Turn off the
power. After a while, turn on the power again.
The
industrial PoE+ switch does not power up. 1. Check to ensure that the AC power cord is
not faulty and that it is inserted properly.
2. If the cord is inserted correctly, replace the power cord.
3. Check that the AC power source is working by connecting a different device in place of the switch.
4. If that device does not work, check the AC
power
NS2052-8P-2C Industrial PoE+ Switch User Manual 18
Appendix A
Networking connection
PoE RJ45 port pin assignments
Pin Number RJ45 Power Assignment
1 Power +
2 Power +
3 Power -
6 Power -
RJ45 port pin assignments – 1000Mbps, 1000BASE-T
Pin number
MDI MDI-X
1
BI_DA+ BI_DB+
2
BI_DA- BI_DB-
3
BI_DB+ BI_DA+
4
BI_DC+ BI_DD+
5
BI_DC- BI_DD-
6
BI_DB- BI_DA-
7
BI_DD+ BI_DC+
8
BI_DD- BI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
10/100Mbps, 10/100BASE-TX
When connecting the industrial PoE+ switch to another Fast Ethernet switch, a bridge, or a hub, a straight or crossover cable is necessary. Each port of the industrial PoE+ switch supports auto-MDI (Media Dependent Interface)/MDI-X (Media Dependent Interface Cross) detection. This makes it possible to directly connect the industrial PoE+ switch to any Ethernet device without making a crossover cable. The following
table and diagram show the standard RJ45 receptacle/ connector and their pin
assignments.
19 NS2052-8P-2C Industrial PoE+ Switch User Manual
Appendix A: Networking connection
Pin number
MDI MDI-X
1
Tx + (transmit) Rx + (receive)
2
Tx - (transmit) Rx - (receive)
3
Rx + (receive) Tx + (transmit)
4, 5
Not used
6
Rx + (receive) Tx + (transmit)
7, 8
Not used
The standard RJ45 receptacle/connector:
There are eight wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and the color of the straight cable and crossover cable connection:
Straight Cable SIDE 1 SIDE 2
SIDE 1 1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
SIDE 2
Crossover Cable SIDE 1 SIDE 2
SIDE 1 1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
1 = White / Green
2 = Green
3 = White / Orange
4 = Blue
5 = White / Blue
6 = Orange
7 = White / Brown
8 = Brown
SIDE 2
Ensure that connected cables are with the same pin assignment and color as the above diagram before deploying the cables into the network.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
20 NS2052-8P-2C Industrial PoE+ Switch User Manual
Appendix A: Networking connection
Fiber Optic cable connection parameters
The wiring details are shown below:
Standard
Fiber Type Cable Specifications
1000BASE
-SX (850 nm) Multi-mode 50/125 μm or 62.5/125 μm
1000BASE
-LX (1300 nm) Multi-mode 50/125 μm or 62.5/125 μm
Single-mode 9/125 μm
Wiring distances
Standard
Fiber Diameter (micron) Modal Bandwidth
(MHz* km)
Max. Distance (meters)
1000BASE
-SX MM 62.5
62.5
50
50
100
200
400
500
220
275
500
550
1000BASE
-LX MM 62.5
50
50
5
4
5
550
SM 9 N/A 5000*
NS2052-8P-2C Industrial PoE+ Switch User Manual 21
Appendix B
Approved Interlogix SFP transceivers
The following list of approved Interlogix SFP transceivers is valid as of the time of publication:
Part #
Fiber
Connector
# of
Fibers
Fiber
Type
Max
Distance
Wave
Length
Optical
Budget
(dBm)
Optical
Power
(dBm)
Receiver
Sensitivity
(dBm)
Operating
Temperature
Twisted Pair SFP 1000Base TX
S30-RJ RJ 45 1 Cat5e
100M
(328 ft.)
0 to +50°C
(32 to 122°F)
Fast Ethernet 100Base FX
S20-2MLC2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 12 -20 ~ -14 -32
0 to +50°C
(32 to 122°F)
S25-2MLC2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 12 -20 ~ -14 -32
-40 to +75°C
(-40 to 167°F)
Fast Ethernet 100Base LX
S20-2SLC20 LC 2
Single
Mode
20 km
(12 mi.)
1310 nm 19 -15 ~ -8 -34
0 to +50°C
(32 to 122°F)
S25-2SLC20 LC 2
Single
Mode
20 km
(12 mi.)
1310 nm 19 -15 ~ -8 -34
-40 to +75°C
(-40 to 167°F)
Fast Ethernet 100Base BX
S20-1SLC/A-
20
LC 1
Single
Mode
20 km
(12 mi.)
1310 /
1550 nm
18 -14 ~ -8 -32
0 to +50°C
(32 to 122°F)
S25-1SLC/B-
20
LC 1
Single
Mode
20 km
(12 mi.)
1550 /
1310 nm
18 -14 ~ -8 -32
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000Base SX
S30-2MLC LC 2
Multi-
mode
220/550 m
(720 /
1800 ft.)
850 nm 7.5 -9.5 ~ -1 -17
0 to +50°C
(32 to 122°F
S35-2MLC LC 2
Multi-
mode
220/550 m
(720 /
1800 ft.)
850 nm 7.5 -14 ~ -8 -17
-40 to +75°C
(-40 to 167°F)
OM1 Multimode fiber @ 200/500 MHz-km
22 NS2052-8P-2C Industrial PoE+ Switch User Manual
Part #
Fiber
Connector
# of
Fibers
Fiber
Type
Max
Distance
Wave
Length
Optical
Budget
(dBm)
Optical
Power
(dBm)
Receiver
Sensitivity
(dBm)
Operating
Temperature
OM2 Multimode fiber @ 500.500 MHZ-km Laser Rated for GbE LANs
S30-2MLC-2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 10 -9 ~ -1 -19
0 to +50°C
(32 to 122°F)
OM3 Multimode fiber @ 2000/500MHz-km Optimized got 850 nm VCSELs
Gigabit Ethernet 1000 Base LX
S30-2SLC-
10
LC 2
Single
Mode
10 km
(6.2 mi.)
1310 nm 18 -9.5 ~ -3 -20
0 to +50°C
(32 to 122°F)
S35-2SLC-
10
LC 2
Single
Mode
10 km
(6.2 mi.)
1310 nm 18 -9.5 ~ -3 -20
-40 to +75°C
(-40 to 167°F)
S30-2SLC-
30
LC 2
Single
Mode
30 km
(18.6 mi.)
1310 nm 18 -2 ~ +3 -23
0 to +50°C
(32 to 122°F)
S35-2SLC-
30
LC 2
Single
Mode
30 km
(18.6 mi.)
1310 nm 18 -2 ~ +3 -23
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000 Base ZX
S30-2SLC-
70
LC 2
Single
Mode
70 km
(43 mi.)
1550 nm 19* -15 ~ -8 -34
0 to +50°C
(32 to 122°F)
S35-2SLC-
70
LC 2
Single
Mode
70 km
(43 mi.)
1550 nm 19* -15 ~ -8 -34
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000 Base BX
S30-1SLC/A-
10
LC 1
Single
Mode
10 km
(6.2 mi.)
1310 /
1490 nm
11 -9 ~ -3 -20
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
10
LC 1
Single
Mode
10 km
(6.2 mi.)
1490 /
1310 nm
11 -9 ~ -3 -20
0 to +50°C
(32 to 122°F)
S30-1SLC/A-
20
LC 1
Single
Mode
20 km
(12 mi.)
1310 /
1490 nm
15 -8 ~ -2 -23
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
20
LC 1
Single
Mode
20 km
(12 mi.)
1490 /
1310 nm
15 -8 ~ -2 -23
0 to +50°C
(32 to 122°F)
Gigabit Ethernet 1000 Base BX
S30-1SLC/A-
60
LC 1
Single
Mode
60 km
(37 mi.)
1310 /
1490 nm
24 0 ~ +5 -24
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
60
LC 1
Single
Mode
60 km
(37 mi.)
1490 /
1310 nm
24 0 ~ +5 -24
0 to +50°C
(32 to 122°F)
* Note: High Power Optic. There must be a minimum of 5 dB of optical loss to the fiber for proper operation.
Note: We recommend the use of Interlogix SFPs on the industrial PoE++ switch. If you
insert an SFP transceiver that is not supported, the industrial PoE+ managed switch will not recognize it.
Note: Choose a SFP/SFP+ transceiver that can be operated under -40 to 75°C
temperature if the industrial PoE+ switch is working in a 0 to 50°C temperature environment.
NS2052-8P-2C Industrial PoE+ Switch User Manual 23
Loading...