NS2052-8P-2C Industrial
PoE+ Switch User Manual
P/N 1073392-EN • REV A • ISS 07FEB18

2018 United Technologies Corporation.
Interlogix is part of UTC
Climate, Controls & Security, a unit of United
Trade names used in this document may be trademarks or registered
trademarks of the
manufacturers or vendors of the respective products.
2955 Red Hill Avenue, Costa Mesa, CA 92626
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference,
and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated i
n a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this
equipment
in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
This Class A digital apparatus complies with CAN ICES
3 (A).
Cet appareil numérique
de la classe A est conforme à la norme CAN ICES-
This is a Class A product. In a domestic environment this product
may cause radio interference in which case the user may be required to
take adequate measures.
- if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
/EU (WEEE directive): Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the
purchase of equivalent new equi
pment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info.

Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND
INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE &
SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON
OR ENTITY BUYING ITS PRODUCTS, INCL
DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS
For more information on warranty disclaimers and prod
information, please check
www.firesecurityproducts.com/policy/product-
or scan the following code:
Contact information
and manuals
For contact information go to:
www.firesecurityproducts.com
To get translations for this and other product manuals go to:
www.firesecurityproducts.com

Content
Important information 2
Chapter 1 Package contents 3
Package contents 3
Chapter 2 Hardware introduction 4
Physical dimensions 4
Product features 9
Product specifications 10
Chapter 3 Installation 13
DIN-rail mounting 13
Wall mount plate mounting 15
Installing the SFP transceiver 15
Chapter 4 Troubleshooting 18
Appendix A Networking connection 19
Appendix B Approved Interlogix SFP transceivers 22
NS2052-8P-2C Industrial PoE+ Switch User Manual 1

Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be liable
for any lost profits or business opportunities, loss of use, business interruption, loss of
data, or any other indirect, special, incidental, or consequential damages under any
theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you.
In any event the total liability of UTCFS shall not exceed the purchase price of the
product. The foregoing limitation will apply to the maximum extent permitted by
applicable law, regardless of whether UTCFS has been advised of the possibility of
such damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or
loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you
should read.
2 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 1
Package contents
The description of the IFS NS2052-8P-2C model is as follows:
Industrial 8-port 10/100TX 802.3at PoE+
+ 2-port TP/SFP combo Ethernet switch
Unless specified, the term “industrial PoE+ switch” mentioned in this user manual refers
to the NS2052-8P-2C.
Package contents
Open the box of the industrial PoE+ switch and carefully unpack it. The box should
contain the following items:
The industrial PoE+ switch × 1
CD with user manual × 1
DIN rail kit x 1
Wall mounting kit x 1
If any of these are missing or damaged, contact your dealer immediately. If possible,
retain the carton including the original packing materials for repacking the product in
case there is a need to return it to us for repair.
3 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 2
Hardware introduction
Physical dimensions
Dimensions (W x D x H): 161 x 107 x 72 mm
4 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 2: Hardware introduction
Front panel
Fast Ethernet TP interfaces (port 1 to port 8)
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit TP interfaces (port 9 to port 10 TP/SFP combo interfaces)
10/100/1000BASE-T copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit SFP slots (port 9 to port 10 TP/SFP combo interfaces)
1000BASE-SX/LX mini-GBIC slot, SFP (Small-form Factor Pluggable) transceiver
module: From 550 meters (multi-mode fiber) and to 10/20/30/40/50/70/120 kilometers
(single-mode fiber).
NS2052-8P-2C Industrial PoE+ Switch User Manual 5

Chapter 2: Hardware introduction
DIP switch
The industrial PoE+ switch has a built-in solid DIP switch that provides “Standard” and
“Extend” operation modes. The industrial PoE+ switch operates as a normal IEEE
802.af/at PoE+ Switch in the “Standard” operation mode.
In the “Extend” operation mode, the industrial PoE+ switch operates on a per-port basis
at 10 Mbps full duplex operation but can support 30 W PoE power output over a
distance of up to 250 meters, overcoming the 100 m limit on Ethernet UTP cable. With
this brand-new feature, the industrial PoE+ switch provides an additional solution for
802.3af/at PoE+ distance extension.
LED indicators
The front panel LEDs indicate port link status, data activity, and system power.
picture
System
1 Green Lit: indicates that the power input 1 has power.
2 Green Lit: indicates that the power input 2 has power.
ault Red Lit: indicates that either power 1 or power 2 has no power.
6 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 2: Hardware introduction
Per 802.3at PoE+ 10/100BASE-TX interface (port 1 to port 8)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 10 Mbps or 100 Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
PoE In-use Orange Lit: indicates the port is providing DC in-line power.
Off: indicates that the connected device is not a PoE
powered device (PD).
Per 10/100/1000BASE-T interface (shared with port 9 to port 10)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 10/100/1000 Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
1000 Orange Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Off: indicates that the link through that port has successfully
connected to the network at 10/100 Mbps.
Per 1000X SFP slot (shared with port 9 to port 10)
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
1000 Orange Lit: indicates the port has successfully connected to the
network at 1000 Mbps.
Off: indicates that the link through that port is not
established.
Switch upper panel
The upper panel of the industrial PoE+ switch consists of one terminal block connector
within two DC power inputs.
NS2052-8P-2C Industrial PoE+ Switch User Manual 7

Chapter 2: Hardware introduction
Wiring the power inputs
The 6-contact terminal block connector on the top panel of Industrial PoE+ switch is
used for two DC redundant power inputs. Follow the steps below to insert the power
wire.
Caution: When performing any of the procedures like inserting the wires or tightening
the wire-clamp screws, make sure the power is OFF to prevent from getting an electric
shock.
1. Insert positive/negative DC power wires into contacts 1 and 2 for DC Power 1, or 5
and 6 for DC Power 2.
2. Tighten the wire-clamp screws to prevent the wires from loosening.
8 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 2: Hardware introduction
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. The DC power input range is 48 to 56 VDC.
Wiring the fault alarm contact
The fault alarm contacts are in the middle of the terminal block connector as the picture
shows below. Inserting the wires, the industrial PoE+ switch detects the fault status of
the power failure and then forms an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts. Wires are inserted into the fault
alarm contacts.
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. Alarm relay circuits accept uo to 30 V, max. 3 A currents.
Product features
Physical port
• Eight 10/100BASE-T Fast Ethernet RJ45 copper ports with IEEE 802.3at/af PoE+
injector (port 1 to port 8).
NS2052-8P-2C Industrial PoE+ Switch User Manual 9

Chapter 2: Hardware introduction
• Two 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (port 9 and port 10).
• Two 100/1000BASE-X mini-GBIC/SFP slots for SFP type auto detection (port 9 and
port 10).
Power over Ethernet
• Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE.
• Backward compatible with IEEE 802.3af Power over Ethernet.
• Up to 8 ports of IEEE 802.3af/IEEE 802.3at devices powered.
• Supports PoE power up to 30 W for each PoE port.
• 240 W PoE budget
• Auto detects powered device (PD).
• Circuit protection prevents power interference between ports.
• Remote power feeding up to 100 meters.
Industrial case and installation
• IP30 aluminum case
• DIN-rail and wall-mount design
• 48 to 56 VDC redundant power with polarity reverse protect function.
• Supports Ethernet ESD protection for 6000 VDC
• -40 to 75°C operating temperature
Switching
• Hardware-based 10/100 Mbps (half/full duplex), 1000 Mbps (full duplex), auto-
negotiation and auto MDI/MDI-X.
• Features Store-and-Forward mode with wire-speed filtering and forwarding rates.
• IEEE 802.3x flow control for full duplex operation and back pressure for half duplex
operation.
• 16K MAC address table size
• 10K jumbo frame
• IEEE 802.1Q VLAN transparency
• Hardware DIP switch for “Standard” and “Extend” mode selection; the “Extend”
mode features 30 W PoE transmit distance of 250 m at a speed of 10 Mbps.
• Automatic address learning and address aging
• Supports CSMA/CD protocol
Product specifications
10 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 2: Hardware introduction
10/100BASE-TX RJ45 auto-MDI/MDI-X ports (port 1 to port 8)
-T RJ45 auto-MDI/MDI-X ports (shared with port 9 and
-SR/LX/BX SFP interfaces (shared with port 9 and port 10)
Eight ports with 802.3af/8
02.3at PoE+ injector function (port 1 to port 8)
pause frame for full-duplex
DIP Switch (Port 1 to Port 8)
Standard mode: 30 W PoE transmit distance of 100 m at speed of 10/100
Mbps.
Extend mode: 30 W PoE transmit
distance of 250 m at speed of 10 Mbps.
-pin terminal block for power input.
Pin 1/2 for Power 1
Pin 3/4 for fault alarm
Pin 5/6 for Power 2
One relay output for power failure. Alarm relay current carry ability:
and power:
DC power 1 (Green)
DC power 2 (Green)
Power fault Alarm (Red)
oE Copper Ports (Port 1 to Port 8):
10/100 Mbps LNK/ACT (Green)
PoE-in-Use (Orange)
Ports (Port 9 to Port 10):
LNK/ACT (Green)
1000 (Orange)
-GBIC Interface (Port 9 to Port 10):
LNK/ACT (Green)
1000 (Orange)
56 VDC, 5.5 A (max.), (>51 VDC for PoE+ output recommended)
19 W, 64 BTU (Standby without PoE function) at DC 56 V power input.
NS2052-8P-2C Industrial PoE+ Switch User Manual 11

Chapter 2: Hardware introduction
23 W, 78 BTU (Full loading without PoE function) at DC 56 V power input.
244 W, 832 BTU (Full loading with PoE function) at DC 56 V power input.
02.3at Power over Ethernet Plus/PSE
Per port 48~51 VDC (depending on the power supply), max. 15.4 W.
Per port 51~56 VDC (depending on the power supply), max. 30 W.
240 W maximum (depending on power input)
Max. Number of Class 3 PDs
Max. Number of Class 4 PDs
IEEE 802.3ab Gigabit 1000BASE
IEEE 802.3z Gigabit SX/LX
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
5 to 95% (non-condensing)
5 to 95% (non-condensing)
12 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 3
Installation
This section describes how to install and make connections to the industrial PoE+
switch. Read the following topics and perform the procedures in the order presented.
Note: The images in the following installation instructions are provided for reference.
The device shown is not the industrial PoE+ switch.
DIN-rail mounting
There are two methods to install the industrial industrial PoE+ switch: DIN-rail mounting
and wall-mount plate mounting. Please read the following topics and perform the
procedures in the order presented.
Note: Follow all the DIN-rail installation steps as shown in the example.
To install the DIN rails on the industrial PoE+ switch:
1. Screw the DIN-rail onto the industrial PoE+ switch.
2. Carefully slide the DIN-rail into the track.
NS2052-8P-2C Industrial PoE+ Switch User Manual 13

Chapter 3: Installation
3. Ensure that the DIN-rail is tightly attached to the track.
To remove the industrial PoE+ switch from the track:
Carefully remove the DIN-rail from the track.
14 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 3: Installation
Wall mount plate mounting
Note: Follow all the wall mount plate installation steps as shown in the example.
To install the industrial PoE+ switch on the wall:
1. Remove the DIN-rail from the industrial PoE+ switch. Use the screwdriver to loosen
the screws to remove the DIN-rail.
2. Place the wall-mount plate on the rear panel of the industrial PoE+ switch.
3. Use the screwdriver to screw the wall mount plate onto the industrial PoE+ switch.
4. Use the hook holes at the corners of the wall mount plate to hang the industrial
PoE+ switch on the wall.
5. To remove the wall mount plate, reverse the steps above.
Installing the SFP transceiver
SFP transceivers are hot-pluggable and hot-swappable. They can be plugged in and
removed to/from any SFP port without having to power down the industrial PoE+ switch
(see below).
NS2052-8P-2C Industrial PoE+ Switch User Manual 15

Chapter 3: Installation
Before connecting to other network devices:
1. Make sure both sides of the SFP transceiver are with the same media type. For
example, 1000BASE-SX to 1000BASE-SX, 1000BASE-LX to 1000BASE-LX.
2. Check if the fiber-optic cable type matches the SFP transceiver requirement.
• To connect to 1000BASE-SX SFP transceiver, use the multi-mode fiber cable
with one side being male duplex LC connector type.
• To connect to 1000BASE-LX SFP transceiver, use the single-mode fiber cable
with one side being male duplex LC connector type.
To connect the fiber cable:
1. Attach the duplex LC connector on the network cable to the SFP/SFP+ transceiver.
2. Connect the other end of the cable to a device with the SFP/SFP+ transceiver
installed.
3. Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the industrial PoE+
switch. Ensure that the SFP/SFP+ transceiver is operating correctly.
4. Check the link mode of the SFP port if the link fails.
Note: We recommend the use of Interlogix SFPs on the industrial PoE+switch. If you
insert an SFP transceiver that is not supported, the industrial PoE+switch will not
recognize it.
To remove the transceiver module:
1. Make sure there is no network activity by checking with the network administrator.
Or, through the management interface of the switch/converter (if available), disable
the port in advance.
16 NS2052-8P-2C Industrial PoE+ Switch User Manual

Chapter 3: Installation
2. Carefully remove the fiber optic cable.
3. Turn the lever of the transceiver module to a horizontal position.
4. Pull out the module gently through the lever.
Note: Never pull out the module without making use of the lever or the push bolts on
the module. Removing the module with force could damage the module and the
SFP/SFP+ module slot of the industrial PoE+ switch.
NS2052-8P-2C Industrial PoE+ Switch User Manual 17

Chapter 4
Troubleshooting
This chapter contains information to help you solve issues. If the industrial PoE+ switch
is not functioning properly, ensure that it was set up according to the instructions in this
manual.
ink LED does not illuminate Check the cable connection.
he industrial PoE+ switch doesn't connect to
1. Check the LNK/ACT LED on the industrial
PoE+ switch.
2. Try another port on the industrial PoE+
switch.
3. Make sure the cable is installed properly.
4. Make sure the cable is the right type.
5. Turn off the power. After a while, turn on
power again.
The port link LED illuminates
Check that the attached device is not set to
dedicated full duplex. Some devices use a
physical or software switch to change duplex
modes. Auto-
negotiation may not recognize this
type of full-duplex setting.
The industrial PoE+ switch doesn’t connect to
the network.
Check each port LED on the industrial PoE+
switch. Try another port. Make sure the cable is
installed properly and the right type. Turn off the
power. After a while, turn on the power again.
industrial PoE+ switch does not power up. 1. Check to ensure that the AC power cord is
not faulty and that it is inserted properly.
2. If the cord is inserted correctly, replace the
power cord.
3. Check that the AC power source is working
by connecting a different device in place of
the switch.
4. If that device does not work, check the AC
power
NS2052-8P-2C Industrial PoE+ Switch User Manual 18

Appendix A
Networking connection
PoE RJ45 port pin assignments
Pin Number RJ45 Power Assignment
1 Power +
2 Power +
3 Power -
6 Power -
RJ45 port pin assignments – 1000Mbps, 1000BASE-T
BI_DD- BI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at a
wiring panel, while not expressly forbidden, is beyond the scope of this standard.
10/100Mbps, 10/100BASE-TX
When connecting the industrial PoE+ switch to another Fast Ethernet switch, a bridge,
or a hub, a straight or crossover cable is necessary. Each port of the industrial PoE+
switch supports auto-MDI (Media Dependent Interface)/MDI-X (Media Dependent
Interface Cross) detection. This makes it possible to directly connect the industrial
PoE+ switch to any Ethernet device without making a crossover cable. The following
table and diagram show the standard RJ45 receptacle/ connector and their pin
assignments.
19 NS2052-8P-2C Industrial PoE+ Switch User Manual

Appendix A: Networking connection
Tx + (transmit) Rx + (receive)
Tx - (transmit) Rx - (receive)
Rx + (receive) Tx + (transmit)
Rx + (receive) Tx + (transmit)
Not used
The standard RJ45 receptacle/connector:
There are eight wires on a standard UTP/STP cable and each wire is color-coded. The
following shows the pin allocation and the color of the straight cable and crossover
cable connection:
Straight Cable SIDE 1 SIDE 2
SIDE 1 1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
SIDE 2
Crossover Cable SIDE 1 SIDE 2
SIDE 1 1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown
1 = White / Green
2 = Green
3 = White / Orange
4 = Blue
5 = White / Blue
6 = Orange
7 = White / Brown
8 = Brown
SIDE 2
Ensure that connected cables are with the same pin assignment and color as the above
diagram before deploying the cables into the network.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
20 NS2052-8P-2C Industrial PoE+ Switch User Manual

Appendix A: Networking connection
Fiber Optic cable connection parameters
The wiring details are shown below:
Fiber Type Cable Specifications
-SX (850 nm) Multi-mode 50/125 μm or 62.5/125 μm
-LX (1300 nm) Multi-mode 50/125 μm or 62.5/125 μm
Single-mode 9/125 μm
Wiring distances
Fiber Diameter (micron) Modal Bandwidth
(MHz* km)
Max. Distance (meters)
-SX MM 62.5
62.5
50
50
100
200
400
500
220
275
500
550
-LX MM 62.5
50
50
5
4
5
550
SM 9 N/A 5000*
NS2052-8P-2C Industrial PoE+ Switch User Manual 21

Appendix B
Approved Interlogix SFP
transceivers
The following list of approved Interlogix SFP transceivers is valid as of the time of
publication:
Part #
Fiber
Connector
# of
Fibers
Fiber
Type
Max
Distance
Wave
Length
Optical
Budget
(dBm)
Optical
Power
(dBm)
Receiver
Sensitivity
(dBm)
Operating
Temperature
Twisted Pair SFP 1000Base TX
S30-RJ RJ 45 1 Cat5e
100M
(328 ft.)
0 to +50°C
(32 to 122°F)
Fast Ethernet 100Base FX
S20-2MLC2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 12 -20 ~ -14 -32
0 to +50°C
(32 to 122°F)
S25-2MLC2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 12 -20 ~ -14 -32
-40 to +75°C
(-40 to 167°F)
Fast Ethernet 100Base LX
S20-2SLC20 LC 2
Single
Mode
20 km
(12 mi.)
1310 nm 19 -15 ~ -8 -34
0 to +50°C
(32 to 122°F)
S25-2SLC20 LC 2
Single
Mode
20 km
(12 mi.)
1310 nm 19 -15 ~ -8 -34
-40 to +75°C
(-40 to 167°F)
Fast Ethernet 100Base BX
S20-1SLC/A-
20
LC 1
Single
Mode
20 km
(12 mi.)
1310 /
1550 nm
18 -14 ~ -8 -32
0 to +50°C
(32 to 122°F)
S25-1SLC/B-
20
LC 1
Single
Mode
20 km
(12 mi.)
1550 /
1310 nm
18 -14 ~ -8 -32
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000Base SX
S30-2MLC LC 2
Multi-
mode
220/550 m
(720 /
1800 ft.)
850 nm 7.5 -9.5 ~ -1 -17
0 to +50°C
(32 to 122°F
S35-2MLC LC 2
Multi-
mode
220/550 m
(720 /
1800 ft.)
850 nm 7.5 -14 ~ -8 -17
-40 to +75°C
(-40 to 167°F)
OM1 Multimode fiber @ 200/500 MHz-km
22 NS2052-8P-2C Industrial PoE+ Switch User Manual

Part #
Fiber
Connector
# of
Fibers
Fiber
Type
Max
Distance
Wave
Length
Optical
Budget
(dBm)
Optical
Power
(dBm)
Receiver
Sensitivity
(dBm)
Operating
Temperature
OM2 Multimode fiber @ 500.500 MHZ-km Laser Rated for GbE LANs
S30-2MLC-2 LC 2
Multi-
mode
2 km
(1.2 mi.)
1310 nm 10 -9 ~ -1 -19
0 to +50°C
(32 to 122°F)
OM3 Multimode fiber @ 2000/500MHz-km Optimized got 850 nm VCSELs
Gigabit Ethernet 1000 Base LX
S30-2SLC-
10
LC 2
Single
Mode
10 km
(6.2 mi.)
1310 nm 18 -9.5 ~ -3 -20
0 to +50°C
(32 to 122°F)
S35-2SLC-
10
LC 2
Single
Mode
10 km
(6.2 mi.)
1310 nm 18 -9.5 ~ -3 -20
-40 to +75°C
(-40 to 167°F)
S30-2SLC-
30
LC 2
Single
Mode
30 km
(18.6 mi.)
1310 nm 18 -2 ~ +3 -23
0 to +50°C
(32 to 122°F)
S35-2SLC-
30
LC 2
Single
Mode
30 km
(18.6 mi.)
1310 nm 18 -2 ~ +3 -23
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000 Base ZX
S30-2SLC-
70
LC 2
Single
Mode
70 km
(43 mi.)
1550 nm 19* -15 ~ -8 -34
0 to +50°C
(32 to 122°F)
S35-2SLC-
70
LC 2
Single
Mode
70 km
(43 mi.)
1550 nm 19* -15 ~ -8 -34
-40 to +75°C
(-40 to 167°F)
Gigabit Ethernet 1000 Base BX
S30-1SLC/A-
10
LC 1
Single
Mode
10 km
(6.2 mi.)
1310 /
1490 nm
11 -9 ~ -3 -20
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
10
LC 1
Single
Mode
10 km
(6.2 mi.)
1490 /
1310 nm
11 -9 ~ -3 -20
0 to +50°C
(32 to 122°F)
S30-1SLC/A-
20
LC 1
Single
Mode
20 km
(12 mi.)
1310 /
1490 nm
15 -8 ~ -2 -23
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
20
LC 1
Single
Mode
20 km
(12 mi.)
1490 /
1310 nm
15 -8 ~ -2 -23
0 to +50°C
(32 to 122°F)
Gigabit Ethernet 1000 Base BX
S30-1SLC/A-
60
LC 1
Single
Mode
60 km
(37 mi.)
1310 /
1490 nm
24 0 ~ +5 -24
0 to +50°C
(32 to 122°F)
S30-1SLC/B-
60
LC 1
Single
Mode
60 km
(37 mi.)
1490 /
1310 nm
24 0 ~ +5 -24
0 to +50°C
(32 to 122°F)
* Note: High Power Optic. There must be a minimum of 5 dB of optical loss to the fiber for proper operation.
Note: We recommend the use of Interlogix SFPs on the industrial PoE++ switch. If you
insert an SFP transceiver that is not supported, the industrial PoE+ managed switch will
not recognize it.
Note: Choose a SFP/SFP+ transceiver that can be operated under -40 to 75°C
temperature if the industrial PoE+ switch is working in a 0 to 50°C temperature
environment.
NS2052-8P-2C Industrial PoE+ Switch User Manual 23