S E N T R O L
P R O D U C T I N F O R M A T I O N B U L L E T I N
5812A SERIES
ACOUSTIC
GLASSBREAK SENSOR
• Designed for quiet occupied
areas on the perimeter loop
• End-user can test sensor operation with a clap of the hands
• Listens across the glassbreak
frequency spectrum for greater
false alarm immunity
• Consistent detection even of
soft, quiet glass breaks
• Detects through blinds and light
drapes
ShatterPro
Model numbers:
5812A-W, 5815A-W, SPRES
The Sentrol 5812A Series ShatterPro
acoustic glassbreak sensor provides great false
alarm immunity, fast installation testing, and a hand-
clap feature that lets end-users confirm the sensor’s
operational status.
Using Sentrol’s patented Pattern Recognition
Technology™, the sensor listens for actual patterns of
breaking glass while eliminating most false alarm
patterns. ShatterPro™ II sensors listen across the
glassbreak frequency spectrum for greater false alarm
immunity.
A new test feature makes installation faster by
eliminating the test mode jumper. The ShatterPro™ II
is tested by activating the Sentrol hand-held
glassbreak tester at close range. Opening the sensor is
unnecessary.
A simple hand-clap feature lets end-users confirm at
any time that the ShatterPro
sensor will blink twice but will not trip when a hand
clap is made close to the unit.
The ShatterPro
pattern, with a 25' (7.5 m) radius from sensor to glass.
The ShatterPro™ II is suitable for use in quiet occupied
areas on the perimeter loop.
™
II detects in a full 360° coverage
™
II
™
II is operational. The
™
II
continued
Sentrol 5810A Series ShatterPro
™
II
Specifications:
Electrical
Operational voltage ........................................... 9 to 16 V DC
Current draw ................................ 12 mA typical; 25 mA max.
Relay output ......... Normally closed, open 4 seconds on alarm
On resistance ................................................. 5 to 15 Ohms
Off resistance ..................................................... 20 MOhms
Maximum loop rating
(relay or tamper loop .............................. 16 V DC, 50mA
Fails safe and opens on power loss
Environmental
Lightning suppression ................... 400 watts for 1 msec pulse
Operating temperature ............ 0°F to 120°F (-18°C to +50°C)
RFI immunity ......................... 20 V/meter from 1 to 1000MHz
Features
Housing material ........................... Flame retardant ABS plastic
Microphone ............................. Omni-directional 360° electret
Sensitivity setting .................................................... Factory set
Range ......................................... 25' (7.5 m) measured to the
farthest point on all glass
25' (7.5 m) on the opposite wall
Glass types detected
Plate glass ............................................... Up to
Tempered glass ...................................... Up to 1⁄4" (6.4 mm)
Wired glass ............................................. Up to
Laminated glass ...................................... Up to
1
⁄4" (6.4 mm)
1
⁄4" (6.4 mm)
1
⁄4" (6.4 mm)
Mounting location ...................................... Ceiling or any wall
Minimum distance from glass ................................... 3.3' (1 m)
Dimensions ................................................... 1.75" (4.5 cm) H
3.25" (8.3 cm) W
0.88" (2.3 cm) D
Color .............................................................................. White
Mounting Location Range ___________________________________________________________________________________
25' (7.5 m)
25' (7.5 m)
Range measured to the farthest glass
360° coverage
Dimensions __________________________________________________________________________________________________
1.75"
4.5 cm
Front View
3.25"
8.3 cm
®
1.75"
4.5 cm
Side View
0.88"
2.3 cm
Ordering Information
Description Model Number Color Listing
ShatterPro II, tamper, latch or non-latch LED 5812A-W White UL
ShatterPro II, tamper, Form C, latch or non-latch LED 5815A-W White ULC
Hand-held Tester 5709C-W White
ShatterPro Residential SPRES White
CORPORATE HEADQUARTERS
12345 SW Leveton Dr., Tualatin, OR 97062
Tel.: 503.692.4052 Fax: 503.691.7566
http://www.sentrol.com
Sentrol reserves the right
to change specifications
without notice.
©1998 Sentrol
U.S. & Canada: 800.547.2556
Technical Service: 800.648.7424
SENTROL
FaxBack: 800.483.2495
G-3225-FLG20K-1297