ShatterPro™ Residential Advanced Acoustic Sensor
with Pattern Recognition Technology
Protected under U.S. Patent 5,192,931 and 5,510,767
Installation Instructions for Surface Mount Models
Surface Mount ShatterPro™ Residential SPRES
SENTROL
™
Surface Mount ShatterPro™ II
Residential SPRES-EZ
WIRING
Strip back the outer jacket on your wiring cable. This will allow wires to flex in the case. Make sure the cable is slack in the wall to
avoid stressing the wires at their connections.
N.C.
COM
SPRES/SPRES-EZ
+
–
ORDERING INFORMATION
Description Model No. Color
ShatterPro™ Residential EZ, non-latch LED SPRES-EZ White
ShatterPro™ Residential, non-latch LED SPRES White
Hand-held Tester, for testing effective range 5709C-W White
RANGE OF COVERAGE
25' (7.5 m)
25' (7.5 m)
ShatterPro sensors are omni-directional, providing 360° coverage.
Coverage is measured from the sensor to the point on the glass
farthest from the sensor. The sensor can be mounted as close as
3.3' (1 m) from the glass.
1. Mounted on opposite wall or adjoining walls, range is 25 ft.
(7.5m) for plate, tempered, laminated and wired glass.
2. Mounted on the ceiling, maximum range is 25 ft. (7.5m) for
plate, tempered, laminated and wired glass.
3. For armor-coated glass, mount sensor no more than 12 ft.
(3.65m) from glass.
Recommended Glass Size:
Minimum 1' x 2' (0.3 m x 0.6 m) or larger
Glass thickness:
Plate: 3/32" to 1/4" (2.4 mm to 6.4 mm)
Tempered: 1/8" to 1/4" (3.2 mm to 6.4 mm)
Wired: 1/4" (6.4 mm)
Laminated: 1/8" to 1/4" (3.2 mm to 6.4 mm)
TESTING THE SENSOR
Put Sensor in Test Mode
1. Connect 9-volt battery to sensor for pre-testing.
2. Use double-stick tape provided to temporarily mount sensor
in desired location.
3. Use Sentrol 5709C Hand-Held Tester to put sensor into test
mode. Set tester to tempered glass and hold on top of
sensor. Activate tester this will trip sensor into test mode
for one minute. In test mode, LED will blink continuously.
To extend test time, activate tester at least once a minute.
Test the Sensor (sensor must be in test mode, blinking)
1. The 5709C tester has settings for different types of glass.
Use tempered setting if unsure of glass type.
2. Hold tester near surface of glass to be protected and aim at
sensor. Press test button.
If drapes or blinds are present, hold the tester behind the
closed drapes or blinds.
3. If LED stays on for 4 seconds, glass is within detection range
of sensor.
4. If LED does not stay on, reposition the sensor and retest.
(Verify adequate battery strength in tester.)
For Best Detection, Avoid Installing In:
Rooms with lined, insulating, or sound deadening drapes.
Rooms with closed wooden window shutters inside.
SENTROL
ShatterSwitch
Shatterbox II
Shatterbox
ShatterPro
5709C
Use for testing:
Shatter Series Tester
stays on during test
Battery LED
Battery is OK if LED
Hold tester so that the speaker is
within 1 inch of sensor microphone
In test mode the sensor LED will light
solid for about 4 seconds,
then blink for about a minute
<1 inch
• Single
• Continuous
Plate •
Laminated •
Tempered •
How Test Mode Works:
Test Mode is activated by the hand-held tester when the tester is
held directly over the microphone and set off. The sensors LED
will blink continuously for 1 minute. During this time, the
installer can test the unit using the instructions above. When the
system is armed and the ShatterPro trips to an alarm condition,
the LED will latch solid for 4 seconds and then revert back to a
1- minute test mode. At the end of 1 minute, the LED will
extinguish.