Interlogix 5515-G User Manual

5500 Moisture Detection Series
Models: 5501 Moisture Processor
5505 Under Carpet Sensor 5515 Surface Mount Sensor
Installation Instructions
Description
The 5501 Moisture Processor can be used with any closed loop control, dialer, or wireless transmitter input circuit. The processor comes with internal lithium batteries that have an anticipated life of 10 to 15 years. The processor offers flexibility in mounting with no need for an external power source and minimal wiring required.
Installation
1 T o open the processor, insert a small, flat-bladed
screwdriver in the slot at top or bottom of the unit and pry the cover up from the base.
2 Mount the processor using the mounting holes
shown in Figure 1.
3 Placement of the sensors depends on the model type:
Model 5505 - Insert the sensor beneath carpeting or rugs. When padding is used, position the sensor between the padding and the carpet. The sensor can be walked on, so there is no need to avoid high traffic areas.
Model 5515 - The sensor can be mounted to any surface and in any position, using screws or double-sided tape.
Maximum of 4 sensors, any mix of Models 5505 or 5515
Wire entry hole
Test Button
Wire entry hole
Sensor
Sensor
Sensor
Sensor
Mounting hole
SENSOR
CLOSED LOOP
+ -
Mounting hole
Closed Loop To control, dialer, or wireless transmitter (observe polarity)
MAXIMUM OF FOUR SENSORS PARALLEL WIRED
OBSERVE POLARITY
Wire entry hole
LED
Wire entry hole
Wiring
The sensors are wired in parallel (see Figure1) without the need to observe polarity . The connection for output, however, is polarity sensitive and should be verified by actually triggering the processor and allowing the control, dialer, or transmitter to operate.
Testing
Press the test button (see Figure 1) for 15 seconds to simulate the presence of water and activate the processor (the LED will flash). Release the button to restore the processor to normal.
5500 Moisture Detection Series
Figure 1.
Operation
A time delay circuit is provided to reduce the chance of false alarms. The processor requires the presence of moisture for 10 seconds before going into alarm mode. It will stay in alarm mode until the moisture is removed from the affected sensor (s). When tripped, the LED will flash at 2-second intervals until the sensor is dry . Isolation from "ground" is obtained by the use of optical coupling between sensor input and processor output circuits.
1
Dimensions
5501 Moisture Processor
2.75"
7.0cm
5505 Under Carpet Sensor
1.00"
2.54cm
3.00"
0.25"
0.63cm
5515 Surface Mount Sensor
7.62cm
4.56"
11.58cm
1.38"
3.51cm
10" Lead
3m
Specifications
Loop type ............................................................................ Closed
Battery type .......................................................................Lithium
Battery life ...................................... Approximately 10 to 15 years
Alarm response ................10 seconds delay, then on as long as wet
Test button............................................Simulates moisture for test
LED ............................................ Flashes every 2 seconds on alarm
Trigger resistance ........................................................... 500K ohm
Sensor isolation from ground ................................... Photo coupled
Sensing circuit .......................... AC to eliminate electolysis (1 Hz)
Cable length ..............................................100 feet (30m) maximum
Loop resistance .............................. 10 ohms maximum (non-alarm)
1 M ohm minimum (alarm)
Operating temperature ....5501 Moisture Processor, 0° F to 125° F
(-17° C to 51° C)
5505 and 5515 sensors, 33° F to 180° F (0° C to 82° C)
Number of sensors per processor ..................................4 maximum
10' Lead
3m
0.7"
1.8cm
3.5"
8.9cm
3.9"
9.9cm
0.6"
1.5cm
Ordering Information
Model Number Description Loop T yp e Co lor Lead
5501 Moisture Processor Closed Mahogany brown T erminals 5505 Under Carpet Sensor N/A White 10 ft (3m) 5515 Surface Mount Sensor N/A Gray 10 ft (3m)
12345 SW Leveton Drive Tualatin, OR 97062 www.interlogixsecurity.com www.sentrol.com
© 2002 GE Interlogix, Inc.
2
Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 FaxBack: 800-483-2495
GE Interlogix
1038436 Rev A 06/02
5500 Moisture Detection Series
Loading...