Intergraph Mylex AcceleRAID 150 User Manual

AcceleRAID™ Installation Guide
AcceleRAID 150 PCI to Ultra2 SCSI RAID Controller
P/N: 775020-01
AcceleRAID
AcceleRAID™ 150
(
960
DAC
PCI to Ultra2 SCSI
RAID Controller
Part Number 775020-01
© Copyright 1999 Mylex Corporation.
All Rights Reserved.
All contents of this manual are copyrighted by Mylex Corporation. The information contained herein is the exclusive property of Mylex Corporation and shall not be copied, transferred, photocopied, translated on paper, film, electronic media, or computer-readable form; or otherwise reproduced in any way, without the express written permission of Mylex C orporation.
PRL
-1)
Greetings
Thank you for purchasing the Mylex AcceleRAID 150 controller. This manual describes the installation of the Mylex AcceleRAID 150 controller. Requests for technical information ab out this and other Mylex Corporation products should be made to your Mylex authorized reseller or Mylex sales representative.
Please Notice
Mylex is a registered trademark, and AcceleRAID, DAC960PRL, and RAID EzAssist are trademarks of Mylex Corporation.
Microsoft, MS-DOS and Windows are registered trademarks of the Micr osoft Corporation. Novell is a r egis te re d t ra d emark of Novell corporati on. U n i xWare is a registered trademark of Santa Cruz Ope rations. Other names that are trademarks may be used herein for the purpose of identifying the products or services of their respective owners.
Unless otherwise noted, companies, names and data used in examples herein are fictitious.
Our Policy
Although reason able efforts have been made to assure the accuracy of the inf o r m ation contained herein, this publication could include technical inaccuracies or typographical errors. Mylex Corporation expressly disclaims liability for any error in this information, and for damages, w hether direct, indirec t, spe cial, exemplary, consequential or otherwi se, that may result from such error, including but not limited to loss of profits resulting from the use or misuse of the manual or information contained therein (even if Mylex Corporation has been advised of the possibility of such damages). Any questions or comments regarding this document or its contents should be addressed to Mylex Corporation at the address shown on the cover.
The following paragraph does not apply to the United Kingdom or any country where such provision s are inco n sistent with local l aw:
MYLEX CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some states do not allow disclaimer of express or implied warranties or the limitation or exclusion of liability for indirect, special, exemplary, incidental or consequential damages in certain transactions; therefore, this statement may not apply to you. Also, you may have other rig hts which vary from jurisdiction to ju risdiction.
Information in this publication is subject to change without notice and does not represent a commitment on the part of Mylex Corporation. Changes may be made periodically to the information herein; th ese changes will be incorpora ted in new editions of the publ ic ation. Mylex Corporatio n re serves the righ t to make i mpro v ement s and/ or ch ang es a t an y t ime in the product(s) and/or program(s) described in this publication.
It is possible that this publication may contain reference to, or information about, Mylex Corporation products (machines and programs), programming or services that are not announced in your country. Such references or information must not be construed to mean that Mylex Corporation intends to announce, provide, or make available such Mylex products, programming, or services in your jurisdiction.

About This Manual

This installation guide covers hardware set-up and configuration procedu r es necessary for the installation of the Mylex AcceleRAID 150 PCI to Ultra2 SCSI RAID controller.
Chapter 1 describes the controller, standard package contents, and user­supplied items necessary for installation.
Chapter 2 describes steps to be performed prior to controller installation and the physical installation of the controller.
Chapter 3 describes controller board start-up and the RAID EzAssist resident utilities.
Appendix A describes installation notes. Appendix B describes hardware and environmental specifications. Appendix C describes error messages and how to correct problems causing
errors.
Appendix D describes enclosure manag ement . Appendix E provides regulatory information.

Conventions

Throughout the manual, the following conventions are used to describe user interaction with the product:
prompt This style of type indicates screen display messages.
Enter Press the key labeled “Enter” (or “Delete”, etc.).
Note
Supplementary information that can ha ve an effect on system performance.
m Caution
Notification that a proscribed action has the potential to adversely affect equipment operation, system performance, or data integrity.
,
WARNING
Notification th at a proscribed action will result i n equipment da mage, data los s , or p er s on al injury .
definitely
Contents
Chapter 1
Introduction
Product Description ...........................................................................1-1
AcceleRAID 150 Controller Features .........................................1-3
Operating System Support ................................................................1-3
Standard Package Contents .............................................................1-4
Hardware ....................................................................................1-4
Software .....................................................................................1-4
User-supplied Items ..........................................................................1-5
Chapter 2
Installation
This chapter describes: .....................................................................2-1
AcceleRAID 150 with Standard PCI Bus ...........................................2-1
Before You Begin (Standard) ............................................................2-2
Standard Installation Checklist ..........................................................2-4
GET READY ..............................................................................2-4
GET SET ....................................................................................2-4
GO ..............................................................................................2-4
Connectors, Jumpers, and LED’s (Standard) .............................2-5
Controller Board Installation (Standard) ............................................2-6
AcceleRAID 150 with SISL
(SCSI Interrupt Steering Logic) .....................................................2-15
Before You Begin (SISL) .................................................................2-16
SISL Installation Checklist ...............................................................2-18
GET READY ............................................................................2-18
GET SET ..................................................................................2-18
GO ............................................................................................2-18
Connectors, Jumpers, and LED’s (SISL) .........................................2-19
Controller Board Installation (SISL) .................................................2-20
Chapter 3
Controller Board Start-up
Procedural Overview .........................................................................3-1
Controller Board Start-up ..................................................................3-2
BIOS Options Sequence ...................................................................3-2
Setting BIOS Options ................................................................3-3
Manual No. 775020 v
RAID EzAssist Configuration Utility Sequence ..................................3-6
Operating System .................................................................. ...... ......3-7
Installing the AcceleRAID as the Primary Controller ..................3-7
Installing the AcceleRAID into an Existing System with a SCSI
Boot Device ..............................................................................3-7
Operating System Device Drivers ......................................................3-8
Global Array Manager (GAM) ............................................................3-8
In Case of Problems ..........................................................................3-9
Appendix A
Installation Notes
Helpful AcceleRAID Installation Notes ...............................................A-1
SCSI Formats and Bus Lengths ........................................................A-1
SCSI Cabling for AcceleRAID 150
(Standard and SISL) .................................. ...... ..... ...... .......................A-2
Appendix B
AcceleRAID Specifications
General Hardware Specifications ......................................................B-1
AcceleRAID ................................................................................B-1
Environmental Specifications ............................................................B-2
DAC960PRL Block Diagram (Standard) ............................................B-3
DAC960PRL Block Diagram (SISL) ...................................................B-4
Appendix C
AcceleRAID Error Messages
Error Messages ................................................................................C-1
Start-up: Error Messages ..........................................................C-1
Drive Check: Error Messages ........................ ...... ...... ..... ........... C-1
Aborted Installation ...........................................................................C-2
NVRAM Error ............................................................................ C-3
System Reboot or Power Down ........................................................C-3
Appendix D
Enclosure Management
Introduction ....................................................................................... D-1
SAF-TE ............................................................................................D-1
vi AcceleRAID 150 Installation Guide
Appendix E
Regulatory Information
Class B Compliance ...................................................................E-1
Declaration of Conformity ................................... ..... ...... ...... ..... ..E-2
Declaration of Conformity ................................... ..... ...... ...... ..... ..E-3
Community of Europe ................................................................E-4
Underwriters Laboratories ..........................................................E-4
Glossary
Manual No. 775020 vii
viii AcceleRAID 150 Installation Guide
This chapter describes:
• Product description
• Standard package contents
• User supplied items
Chapter 1
Introduction
Figure 1-1. AcceleRAID 150 Disk Array Controller

Product Description

The AcceleRAID™ 150 (DAC960PRL-1) is a single-channel PCI-to-Ultra2 SCSI, LVD (Low Voltage Differential) RAID Controller. It has all the functions and performance characteristics of the Mylex line of RAID controllers for several popular network operating systems.
The Mylex AcceleRAID 150 offers the ultimate flexibility in a controller board, as a standard PCI configuration or as a SCSI I nterrupt Steering Logic (SISL) configuration.
The AcceleRAID 150 controller board works on two different types of system boards: a standard system or PC board that has the standard PCI bus interface, or a system board with embedded SCSI that allows the AcceleRAID 150 controller to steer RAID features (the SISL feature) onto the embedded SCSI channel(s).
Manual No. 775020 1-1
Product Description
Mylex’s AcceleRAID 150 can be used in either one of the following two situations:
1. A cost-effective, single-channel, standard PCI RAID controller board, which may reside in any PCI slot (to implement a standard RAID connection), or
2. A cost-effective PCI RAID controller board with SISL, which must reside in the prewired, SISL-dedicated slot on a system board (to implement a SISL connection). See your system board documentation to identify your board’s specific PCI slot that supports SCSI Interrupt Steering Logic (SISL).
In addition to the choice of any system board for one of the above situations, note that some Intel
boards also give you the following flexibility:
®
1. Use the AcceleRAID 150 board plugged into a standard PCI slot as a single-channel board, or
2. Use the AcceleRAID 150 board plugged into a SISL enhanced PCI slot. The controller board takes control of the SCSI channels allowing RAID configurations to be extended from the controller board to the embedded SCSI channels on the system board.
The following Intel boards: N440BX, T440BX, NA440BX, NC440BX and SC450NX are examples of the server boards and systems that support the SISL feature of the AcceleRAID 150 controller.
A specially configured dedicated SISL slot is required to use SCSI Interrupt
Steering Logic (SISL).
Mylex AcceleRAID controllers supply the necessary signals that enable
SISL hardware to capture and control the embedded SCSI channel(s) on the
system board. This feature implements RAID capabilities on the SCSI
channels that reside on the system board.
1-2 AcceleRAID 150 Installation Guide
Introduction

AcceleRAID 150 Controller Features

Includes the following features:
• Ability to operate in an ordinary PCI slot as a single-channel RAID controller in any PCI system.
• Ability to add the functionality of an additio nal RAID SCSI channel which is a Wide Ultra2 SCSI RAID LVD channel (see the note below for further explanation).
Note
The AcceleRAID 150 will work as a single-channel, Wide Ultra2 SCSI LVD RAID controller with a system board that has an available PCI slot.
A specially configured, dedicated PCI slot is required to enable SISL, which allows the controller to add RAID capability to a system board’s built-in SCSI channels.
See your system board document ation to identify your board’s specific PCI slot that supports SCSI Interrupt Steering Logic (SISL).

Operating System Support

MS-DOS 5.x, 6.x, and above are supported using dri ver s that are included in the Disk Array Software Kit. Many other popular operating systems are supported using software drivers in the Disk Array Controller Software Kit that is included with the AcceleRAID controller (see the Disk Array Controller Software Kit Installation Guide and User Manual – P/N 771929)
Manual No. 775020 1-3

Standard Package Contents

Standard Package Contents
The following items are supplied with the standard shipping package:

Hardware

• AcceleRAID 150 Disk Array Controller with documentation

Software

• Disk Array Controller Configuration (RAID EzAssist™) utility with documentation on CD-ROM
• Disk Array Controller Software Kit with documentation on CD-ROM
• OS drivers (controller drivers) on diskette
• Global Array Manager (GAM client and GAM Server) with documentation on CD-ROM
AcceleRAID 150 Controller
Manuals
Software Utilities and Drivers
Drivers
Quick Installation Guide
Figure 1-2. S t an dard Package Contents
1-4 AcceleRAID 150 Installation Guide
Introduction

User-supplied Items

The following user-supplied items are required to perform this installation:
• Host system with a PCI slot, or
• Host system with a prewired SISL supported PCI slot in order to use the SISL feature
• SCSI cables to connect SCSI channels to disk drives
• Operating system sof t ware
• Static grounding strap or electrostatic discharge (ESD) safe work area
• Disk array enclosure (or equivalent) and SCSI disk drives
Note
The supported SCSI drive types include Ultra2 SCSI with LVD as well as the following single-ended SCSI types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra SCSI, and Wide Ultra SCSI.
Figure 1-3. AcceleRAID 150 External Connector (0.8mm UHD Centronics 68F):
68-Pin Very High Density Cable Interconnect (VHDCI)
Figure 1-4. AcceleRAID 150 Internal Connector (HD DB68F):
68-Pin High Density
Manual No. 775020 1-5
User-supplied Items
1-6 AcceleRAID 150 Installation Guide
Chapter 2
Installation

This chapter describes:

• Before you begin
• Connectors, Jumpers, and LED’s
• Safety considerations:
• Installing the AcceleRAID 150 board (controller)

AcceleRAID 150 with Standard PCI Bus

Note
If you will be installing the AcceleRAID 150 controller board with the SISL feature, please go to the section titled “AcceleRAID 150 with SISL (SCSI Interrupt Steering Logic)” on page 2-15.
m Caution
If an operating system or existing data resides on drives already installed on the system, a full backup should be performed on these drives prior to this installation.
Caution and Warning notes
Manual No. 775020 2-1

Before You Begin (Standard)

Before You Begin (Standard)
Installing a standard AcceleRAID 150 PCI to Ultra2 SCSI RAID controller board is no more difficult than installing any PCI adapter board. Follow these steps and then follow the installation procedures in this chapter. Occasionally, you may need to refer to the instructions that came with your computer system.
, WARNING
Power OFF the system and disconnect the power cord from the electrical wall outlet before opening the system cabinet. Working with the system covers off and power applied to the system can result in shock and serious injury.
, WARNING
This controller board is furnished with a nonvolatile RAM (NVRAM) chip that uses a sealed lithium battery/crystal module. Replace the module only with the same or equivalent type recommended by the manufacturer.
Dispose of the used battery/crystal module according to the manufacturer’s instructions. Never incinerate a battery as it could explode and cause serious injury.
2-2 AcceleRAID 150 Installation Guide
Installation
1. Power OFF the system and any enclosures, such as a tower, and disconnect the power cord and cables before starting the installation. Refer to the instructions provided in your system documentation. Do not disconnect cables or power cords while system power is ON.
2. Read all of the instructions in this chapter completely b efore pro c eed­ing. Follow the Notes, Cautions, and Warnings described in this manual and marked on the equipment.
3. Safety check the installation before powering ON the system:
• Make sure SCSI cables are properly connected.
• Make sure all SCSI conventions (cable type, cable length,
termination, and SCSI addresses) are followed. Examples of cable types are: flat, rounded, shielded, or non-shielded -- use like types together.
• For information about cable lengths and formats, please refer to
Table A-1 on page A-1.
Manual No. 775020 2-3

Standard Installation Checklist

Standard Installation Checklist

GET READY

Note
It is recommended that you wear a grounded wrist strap when working with hardware installation procedures.
1. ____ Decide which available standard PCI slot will be used.
2. ____ Remove the plate from the I/O access port to the PCI slot.
3. ____ Remove the AcceleRAID 150 controller board from the anti­static bag.
4. ____ Check Jumper 10 (JP10). If it is installed on the jumper pins, remove it according to Figure 2-6.

GET SET

5. ____ Plug the AcceleRAID 150 board into a standard PCI slot.
6. ____ Tighten the AcceleRAID 150 board into the mounting bracket.
7. ____ Connect the SCSI cable(s) drives and/or devices to the board.
8. ____ Check termination - Only internal or external devices.
9. ____ Check termination - Both internal and external devices.
10. ____ Remove or set termination jumpers to the disabled position on the disk drive.
11. ____ Set SCSI ID on the disk drive.
12. ____ Enable termination power on disk drives.
13. ____ Safety check the installation.
Note
Review Figure 2-1 and Table 2-1 to get familiar with the layout of the AcceleRAID 150 controller board and the Connectors, Jumpers, and LED descriptions.
GO
14. ____ Go to Chapter 3, Controller Board Start-up.
2-4 AcceleRAID 150 Installation Guide

Connectors, Jumpers, and LED’s ( Standard)

J
Figure 2-1 is a diagram of the AcceleRAID 150 Low Profile board.
1
Internal Connector
J2
External
Connector
(VHDCI)
(68-Pin High Density)
JP10
Note:
J1 and J2 are both on the same Channel.
Figure 2-1. AcceleRAID Connectors, Jumpers, a nd LED’s
Table 2-1. AcceleRAID Connectors, Jumpers, and LED Descriptions
Component Description
JP1 Two-pin header available for connection to a front panel LED
that indicates SCSI activity (user supplied). JP4 Reserved JP5 Not used / for maintenance only. JP10 OFF = Disable SISL ON = Enable SISL J1 Channel 0 Internal Ultra2 SCSI LVD Connector –
68-Pin High Density Cable J2 Channel 0 External Ultra2 SCSI LVD Connector –
68-Pin Very High Density Cable Interconnect (VHDCI) U1 LED, ON indicates the controller board failed internal diagnostics
during start-up. LVD (D3) LED, ON = default; the light is always on unless a single-ended
device is connected. The light will turn OFF when a single-ended
device is detected*. SE (D2) LED, ON indicates a single-ended drive is detected.
* The LVD and SE lights will not be ON or OFF at the same time.
JP1
U1
SE
LVD
JP4
JP5
Installation
Manual No. 775020 2-5

Controller Board Installation (Standard)

Controller Board Installation (Standard)
m Caution
Anti-static handling procedures are required. Leave the controller board in its anti-static bag until it is time to plug it into the PCI slot.
Wearing a grounded wrist strap (see Figure 2-2), having the power cord pluged into an electric-ground wall outlet, ha ving t he computer po wer turned off, and following other ESD protective measures are highly recommended. See warning below about unplug ing the power cord when the computer cover is removed.
Figure 2-2. Wear a grounded wrist strap.
WARNING
,
Disconnect the system from the electrical wall outlet before opening the system cabinet. Working with the system covers off and power applied to the system can result in shock and serious injury.
2-6 AcceleRAID 150 Installation Guide
Installation
Follow these installation steps:
1. Choose any available standard PCI slot as shown in Figure 2-3.

Figure 2-3. Choose an Available PCI Slot
2. Remove the metal cov er plate fro m the slot’s access port (usually at the back of the cabinet). Save the retaining screw as shown in Figure 2-4.
.
Metal Plate
Remove screw to remove metal plate. Save screw to tighten the controller board.
Figure 2-4. Remove the Metal Plate
Manual No. 775020 2-7
Controller Board Installation (Standard)
3. Remove the AcceleRAID 150 controller board from the anti-static bag as shown in Figure 2-5.
Figure 2-5. Remove the Anti-static Bag
4. If Jumper 10 (JP10) is installed, place it on only one peg to the OFF position, as shown in Figure 2-6, when using the standard AcceleRAID 150 configuration.
Figure 2-6. Jumper 10 (JP10) on one p e g, OFF position
2-8 AcceleRAID 150 Installation Guide
Installation
5. Plug the controller board firmly into the selected standard PCI slot as shown in Figure 2-7.
System Board
Plug Controller into any Available PCI Slot
Figure 2-7. Plug Controller Board into any Standard PCI Slot
6. Use the retaining screw (see Figure 2-4) to tighten the controller board by its mounting bracket. The controller board will go into the space created when you removed the metal plate.
Manual No. 775020 2-9
Controller Board Installation (Standard)
7. Connect the SCSI cables from the disk drives to a SCSI connector on the AcceleRAID 150 controller board, as shown in Figure 2-8. (The controller board is already connected to the system board.) If necessary, refer to Table A-1 on page A-1 for SCSI formats and bus lengths.
Note
In order to ensure an error free environment, the proper cable type designed for a certain SCSI speed must be used.
Note
Wide and narrow SCSI disk installed together (mixed) on any one channel, or the AcceleRAID controller board may not work properly. It is ok to mix wide and narrow connections for other devices, but
do not mix SCSI disk drives.
drives
must not be
T
T
Figure 2-8. Connecting Disk Drives to the AcceleRAID 150
Note
It is recommended that non-RAID SCSI devices be connected to a separate SCSI channel, either on the system board or furnished b y a SCSI hos t bus adapter board, such as a Mylex FlashPoint board.
See Appendix A for information on LVD mode and single-ended mode.
2-10 AcceleRAID 150 Installation Guide
Installation
8. Termination - Only Internal or External Devices (Standard)
Check that the drive channel is properly terminated according to drawings below. The AcceleRAID 150 is equipped with automatic SCSI termination circuitry which handles automatic enabling and disabling of on-board termination. For example, if the controller board is at the end of the SCSI bus, it automatically enables on-board termination.
If all the SCSI devices on a channel are connected either to the internal connector or to the external connector, the end of the SCSI bus farthest from the controller board must have a terminator installed; the controller board automatically enables on-board termination. See Figure 2-9 for an example of an internal drive configuration. See Figure 2-10 for an example of an external drive configuration.
T
T
AutoTermination
Enabled
Figure 2-9. Termination with Internal Drive Configuration
Auto Termination
T
Enabled
T
Figure 2-10. Termination with External Drive Configuration
Manual No. 775020 2-11
Internal Drive Configuration
External Drive Configuration
Controller Board Installation (Standard)
9. Te rmination - Both Internal and External Devices (Standard) Check that the drive channel is properly terminated according to drawing below. If the controller board is in the middle of the SCSI bus, it automatically disables on-board termination. If some SCSI devices on the channel are connected to the internal connector, and some are connected to the external connector, the two ends of the SCSI bus farthest from the controller board must each be terminated; this allows hot swap capability.
See Figure 2-11 for an example of a combined internal and external drive configuration. Notice that they are on the same channel.
Note
It is better to terminate the ends of the SCSI bus itself than it is to terminate the end devices o n the bus. This allows hot sw ap devices to be added or removed from the SCSI bus without affecting termination.
Note
The only devices controlled by the RAID configuration are the ones physically connected to the AcceleRAID 150 card.
T
Auto Termination
Disabled
T
Figure 2-11. Terminat i on wit h In t ernal and External Dri ve Conf ig ur ation
2-12 AcceleRAID 150 Installation Guide
Internal – External Drive Configuration
Installation
10. Remove or set disk drive termination jumpers to the disabled position (if needed). Refer to your system documentation furnished with your disk drives to determine if your termination jumpers need to be adjusted.
11. Set the SCSI ID on the disk drives: ID 7 is reserved for the controller board.
Note
Each drive must have a unique ID chosen from 0 through 6 or 8 through 15. Be careful not to duplicate a drive address on the same channel.
Remember:
therefore, it cannot be used as a disk drive ID. ID’s from 0 through 6 are usually for Narrow,
8-bit devices. Ho wever, the full range of SCSI ID addresses, 0 through 6 and 8 through 15 can be used for Wide, 16-bit devices.
See your device documentation for instructions on how to set your particular disk drive’s SCSI address.
ID 7 is reserved for the co ntroller boar d;
SCSI ID Numbers
7 is reserved for the controller
Figure 2-12. SCSI ID Numbers
Manual No. 775020 2-13
Controller Board Installation (Standard)
12. Enable termination power to all the disk drives (usually there is a jumper on the drive). See your device documentation for instructions on how to set your particular disk drive’s termination power and configuration options.
Note
The supported SCSI drive types include Ultra2 SCSI with LVD as well as the following single-ended SCSI types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra SCSI, Wide Ultra SCSI, and Wide Ultra2 SCSI.
13. Safety check the installation by checking Pin 1 locations and cable types. For more details, see step 3 in the section titled “Before You Begin (Standard)” on page 2-2.
14. Replace the cover and connect the power cord.
The standard AcceleRAID 150 installation is complete.
Proceed to the next chapter for controller board start-up procedures and other setup options.
2-14 AcceleRAID 150 Installation Guide

AcceleRAID 150 with SISL (SCSI Interrupt Steering Logic)

Note
If you will be installing the AcceleRAID 150 controller board as a standard unit without the SISL feature, please go to the section titled “AcceleRAID 150 with Standard PCI Bus” on page 2-1.
m Caution
If an operating system or existing data resides on drives connected to the system board’s resident SCSI channels, a full backup must be performed on these drives prior to this installation.
Installation
Manual No. 775020 2-15

Before You Begin (SISL)

Before You Begin (SISL)
Installing AcceleRAID PCI to Ultra2 SCSI RAID controller board is no more difficult than installing any PCI adapter board. Follow these steps and then follow the installation procedures in this chapter . Occasionally, you may need to refer to the instructions that came with your computer system.
, WARNING
Disconnect the system from the electrical wall outlet before opening the system cabinet. Working with the system covers off and power applied to the system can result in shock and serious injury.
, WARNING
This controller board is furnished with a nonvolatile RAM (NVRAM) chip that uses a sealed lithium battery/crystal module. Replace the module only with the same or equivalent type recommended by the manufacturer.
Dispose of the used battery/crystal module according to the manufacturer’s instructions. Never incinerate a battery as it could explode and cause serious injury.
1. Power OFF the system and any enclosures, then, disconnect the power cables before starting the installation. Refer to the instructions provided in your system documentation. Do not disconnect cables or power cords while system power is ON.
2. Read all of the instructions in this chapter completely b efore pro ceed­ing. Follow the Notes, Cautions, and Warnings described in this manual and marked on the equipment.
2-16 AcceleRAID 150 Installation Guide
3. Safety check the installation before powering ON the system.
• Make sure cables are properly oriented so that the colored stripe (Pin 1) on the edge of the ribbon cable aligns with Pin 1 on the connector (see Figure 2-13).
Pin 1
This is a connector on the system board, face up. Align the colored stripe on the edge of the ribbon SCSI cable to Pin 1 on the connector.
Note: the colored stripe is Pin 1 in the SCSI cable.
Figure 2-13. SCSI Cable Pin 1 Alignment to the Connector
• Make sure all SCSI conventions (cable type, cable length, termination, and SCSI addresses) are followed. Examples of cable types are: flat, rounded, shielded, or non-shielded -- use like types together.
• For information about cable lengths and formats, please refer to Table A-1 on page A-1.
Installation
Manual No. 775020 2-17

SISL Installation Checklist

SISL Installation Checklist

GET READY

Note
It is recommended that you wear a grounded wrist strap when working with hardware installation procedures.
1. ____ Locate the prewired SISL slot, see your system documentation.
2. ____ Remove the plate from the I/O access port to the SISL PCI slot.
3. ____ Remove the AcceleRAID 150 controller board from the anti­static bag.
4. ____ Check Jumper 10 (JP10). If it is not on the jumper pins, install it to the ON position as shown in Figure 2-19

GET SET

5. ____ Plug the AcceleRAID 150 board into the prewired SISL slot.
6. ____ Tighten the AcceleRAID 150 board into the mounting bracket.
7. ____ Connect the SCSI cable(s) drives and/or devices to the board.
8. ____ Check termination for both internal and external configuration.
9. ____ Check termination for embedded system board channels.
10. ____ Remove or set termination jumpers to the disabled position on the disk drive.
11. ____ Set SCSI ID on the disk drive.
12. ____ Enable termination power on th e disk drive.
13. ____ Safety check the installation.
.
Note
Review Figure 2-14 and T able 2-2 to get familiar with the layout of the AcceleRAID 150 board and the Connectors, Jumpers, and LED descriptions.
GO
14. ____ Go to Chapter 3, Controller Board Start-up.
2-18 AcceleRAID 150 Installation Guide
Installation
J

Connectors, Jumpers, and LED’s (SISL)

Figure 2-14 is a design example of the AcceleRAID 150 Low Profile board.
1
Internal Connector
J2
External
Connector
(VHDCI)
(68-Pin High Density)
JP10
Note: J1 and J2 are both on the same Channel.
Figure 2-14. AcceleRAID Connectors, Jumpers, and LED’s
Table 2-2. AcceleRAID Connectors, Jumpers, and LED Descriptions
Component Description
JP1 Two-pin header available for connection to a front panel LED
that indicates SCSI activity (user supplied). JP4 Reserved JP5 Not used / for maintenance only. JP10 OFF = Disable SISL ON = Enable SISL J1 Channel 0 Internal Ultra2 SCSI LVD Connector –
68-Pin High Density Cable J2 Channel 0 External Ultra2 SCSI LVD Connector –
68-Pin Very High Density Cable Interconnect (VHDCI) U1 LED, ON indicates the controller board failed internal diagnostics
during start-up. LVD (D3) LED, ON = default; the light is always on unless a single-ended
device is connected. The light will turn OFF when a single-ended
device is detected*. SE (D2) LED, ON indicates a single-ended drive is detected.
* The LVD and SE lights will not be ON or OFF at the same time.
JP1
U1
SE
LVD
JP4
JP5
Manual No. 775020 2-19

Controller Board Installation (SISL)

Controller Board Installation (SISL)
m Caution
Anti-static handling procedures are required. Leave the controller board in its anti-static bag until it is time to plug it into the PCI slot.
Wearing a grounded wrist strap (see Figure 2-15), having the power cord pluged into an electric-ground wall outlet, ha ving t he computer po wer turned off, and following other ESD protective measures are highly recommended. See warning below about unpluging the power cord when the computer cover is removed.
Figure 2-15. Wear a grounded wrist strap.
WARNING
,
Disconnect the system from the electrical wall outlet before opening the system cabinet. Working with the system covers off and power applied to the system can result in shock and serious injury.
2-20 AcceleRAID 150 Installation Guide
Installation
Follow these installation steps:
1. Choose the dedicated PCI slot that was prewired for SISL functionality, (see your system documentation to identify the position of the SISL slot on your system board) as shown in Figure 2-16.

Figure 2-16. Identify SISL PCI Slot
2. Remove the metal cov er plate fro m the slot’s access port (usually at the back of the cabinet) as shown in Figure 2-17. Save the retaining screw.
Metal Plate
Remove screw to remove metal plate. Save screw to tighten the controller board.
Figure 2-17. Remove the Metal Plate
Manual No. 775020 2-21
Controller Board Installation (SISL)
3. Remove the AcceleRAID 150 controller board from the anti-static bag as shown in Figure 2-18.
Figure 2-18. Remove Controller Board from the Anti-Static Bag
4. If Jumper 10 (JP10) is not in place, install it (ON position), as sh ow n in Figure 2-19, when using the AcceleRAID 150 with the SISL feature.
Figure 2-19. Install Jumper 10 (JP10) on two pegs, ON position
2-22 AcceleRAID 150 Installation Guide
Installation
5. Plug the AcceleRAID 150 controller board firmly into the dedicated, prewired SISL PCI slot as shown in Figure 2-20.
Channel 0
T
Plug Controllerinto the Specially Wired SISL PCI Slot
System Board
Wide SCSI Connector on System Board (Ch 1)
Narrow SCSI Connector on System Board (Ch 2)
T
Figure 2-20. AcceleRAID 150 in a Typical SISL Installation
6. Use the retaining screw (see Figure 2 -17) to secur e the controller boar d by its mounting bracket. The controller board will go into the space created when you removed the metal plate.
Manual No. 775020 2-23
Controller Board Installation (SISL)
7. Connect the SCSI cables from the disk drives to the drive channels, as required, according to the example shown in Figure 2-21. (The controller board is already connected to the system board.) If necessary, refer to Table A-1 on page A-1 for SCSI formats and bus lengths.
Note
In order to ensure an error free environment, the proper cable type designed for a certain SCSI speed must be used.
Note
Wide and narrow SCSI disk
drives
must not be installed together (mixed) on any one channel, or the AcceleRAID controller board may not work properly. It is ok to mix wide and narrow connections for other devices, but
do not mix SCSI disk drives.
Channel 0
T
Plug Controller into the Specially Wired SISL PCI Slot
Figure 2-21. AcceleRAID 150 Typical SISL Installation showing channels
Note
System Board
Wide SCSI Connector on System Board (Ch 1 )
Narrow SCSI Connector on System Board (Ch 2)
T
It is recommended that non-RAID SCSI devices be connected to a separate SCSI channel, either on the system board or furnished b y a SCSI hos t bus adapter board, such as a Mylex FlashPoint board.
See Appendix A for information on LVD mode and single-ended mode.
2-24 AcceleRAID 150 Installation Guide
Installation
8. AcceleRAID 150 Termination (SISL)
Check to confirm that all drive channels are properly terminated as shown in Figure 2-22. The AcceleRAID 150 is equipped with automatic SCSI termination circuitry for the SCSI channel that resides on the AcceleRAID board. If the controller board is at the end of the SCSI bus, it automatically enables on-board termination.
If all the SCSI devices on a channel are co nnected either to the in ternal connector or to the external connector, the end of the SCSI bus farthest from the controller board must have a terminator installed. In this case, the controller board automatically enables on-board termination.
If some SCSI devices on the channel are connected to the internal connector, and some are connected to the external connector, the two ends of the SCSI bus farthest from the controller board must each be terminated. In this case, the controller board automatically disables on-board termination. See Figure 2-22 for an example of an internal – external drive configuration. Notice the terminator “T” symbol indicating termination at the farthest bus ends. External drive cabinets usually have termination built into the end of the SCSI bus.
Note
The illustrated internal and external connectors are both on the same channel.
It is better to terminate the ends of the SCSI bus itself than it is to terminate the end devices o n the bus. This allows hot sw ap devices to be added or removed from the SCSI bus without affecting termination.
T
T
Figure 2-22. Termination with Internal - External Drive Configuration
Manual No. 775020 2-25
Controller Board Installation (SISL)
9. SCSI Termination for Embedded System Board Channels (SISL)
Correct termination is critical for the SCSI channels. Termination on the end of the bus conn ecti n g t he dis k dr ives (or other SCSI devices) is required.
SCSI termination for the SCSI channels that reside on the system board need to be properly controlled (notice the terminator “T” symbol) as shown in Figure 2-23. You may also want to refer to documentation that was provided with your system.
Note
It is better to terminate the end of the SCSI bus itself than it is to terminate the end device on the bus. This allows hot sw ap devices to be added or removed from the SCSI bus without affecting termination.
Channel 0
T
Plug Controller into the Specially Wired SISL PCI Slot
System Board
Wide SCSI Connector on System Board (Ch 1 )
Narrow SCSI Connector on System Board (Ch 2)
T
Figure 2-23. System Boar d SC SI Ter m ina tion
2-26 AcceleRAID 150 Installation Guide
Installation
10. Remove or set disk drive termination jumpers to the disabled position (if needed). Refer to your system documentation furnished with your disk drives to decide if your termination jumpers need to be adjusted.
11. Set the SCSI ID on the disk drives: ID 7 is reserved for the controller board, as shown in Figure 2-24 .
Note
Each drive must have a unique ID chosen from 0 through 6 or 8 through 15. Be careful not to duplicate a drive address on the same channel.
Remember:
therefore, it cannot be used as a disk drive ID. ID’s from 0 through 6 are usually for Narrow,
8-bit devices. Ho wever, the full range of SCSI ID addresses, 0 through 6 and 8 through 15 can be used for Wide, 16-bit devices.
See your device documentation for instructions on how to set your particular disk drive’s SCSI address.
ID 7 is reserved for the co ntroller boar d;
SCSI ID Numbers
7 is reserved for the controller
Figure 2-24. SCSI ID Numbers
Manual No. 775020 2-27
Controller Board Installation (SISL)
12. Enable termination power to all the disk drives (usually there is a jumper on the drive). See your device documentation for instructions on how to set your particular disk drive’s termination power and configuration options.
Note
The supported SCSI drive types include Ultra2 SCSI with LVD as well as the following single-ended SCSI types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra SCSI, Wide Ultra SCSI, and Wide Ultra2 SCSI.
m Caution
If wide drives are to be connected to an on-board narrow SCSI connector (by a 68-pin to 50-pin adapter), the 8-bit bus width parameter must be set first, using the RAID EzAssist Configuration Utility.
Instructions on how to force the 8-bit bus width are in the RAID EzAssist Configuration Utility User Reference Guide (P/N 775029) under “Advanced Parameters.”
13. Safety check the installation by checking Pin 1 locations and cable types. For more details, see step 3 in the section titled “Before You Begin (SISL)” on page 2-16.
14. Replace the cover and connect the power cord.
2-28 AcceleRAID 150 Installation Guide
Installation
m Caution
If the SCSI channels embedded on the system board are controlled by a Symbios Logic® chipset, the Symbios BIOS must be disabled in the system BIOS before proceeding with RAID configuration, or with operating system or driver installation. This is to allow the AcceleRAID 150 to take ov er co ntrol of the system board's embedded channels without any conflicts.
The Symbios BIOS can be disabled by ru nning the CMOS setup routine when powering on your system (see the documentation that is furnished with your system).
The SISL AcceleRAID 150 installation is complete. Proceed to the next chapter for controller board start-up procedures and
other setup options.
Manual No. 775020 2-29
Controller Board Installation (SISL)
2-30 AcceleRAID 150 Installation Guide
Chapter 3
Controller Board Start-up
This chapter describes:
• Start-up procedures
• BIOS options
• RAID EzAssist Configuration Utility
• Driver Installation
• What to check in case of problems
This chapter describes the AcceleRAID 150 controller start-up procedures and messages produced by the BIOS during start-up or reboot. This chapter also explains three BIOS options that are available for configuring the controller operation.

Procedural Overview

The steps covered in this chapter include:
1. Setting BIOS options
2. RAID EzAssist configuration utility– refer to the RAID EzAssist Configuration Utility User Reference Guide (P/N 775029) for configuration instructions and default control ler pa rameter definitions.
3. Loading the operating system and operating system drivers – refer to the Disk Array Controller Software Kit Installation Guide and User Manual (P/N 771929) for installation instructions for operating system drivers and the GAM server module.
4. Installing Global Array Manager – refer to the Global Array Manager Client Software Installation Guide and User Manual (P/N 771961) for installation instructions for the GAM client.
Manual No. 775020 3-1

Controller Board Start-up

Controller Board Start-up
The start-up procedure should be performed prior to any software configuration. There are two start-up sequences: the BIOS Options sequence and the BIOS Configuration Utility sequence. Either start-up sequence can be skipped by ignoring the computer is started up.
<ALT-M> and/or the <ALT-R> prompt when the

BIOS Options Sequence

After physically installing the controller and connecting the cabling, do the following if you need to change any BIOS option settings. (See “Setting BIOS Options” on page 3-3 for details.)
1. Before turning power on to the computer, power ON any external enclosures connected to the controller.
2. Power ON the computer.
3. Watch the messages on the screen for the following prompt to be displayed:
Press <ALT-M> for BIOS options
4. Press Alt–M to get into the BIOS Options menu.
5. The BIOS Options menu provides the following items to choose from:
6. To select any of the items in the menu, highlight the selection with the Up Arrow or Down Arrow. Press Enter to toggle any of the three items.
Note
BIOS must be enabled to toggle the CD-ROM boot and the Drive geometry parameters.
3-2 AcceleRAID 150 Installation Guide
Controller Board Start-up

Setting BIOS Options

The available BIOS options are:
• BIOS disabled / enabled
• CD-ROM boot disabled / enabled
• 2 GB / 8 GB drive geometry
BIOS Disable or Enable
This option must be enabled in order to toggle the CD-ROM boot and the drive geometry parameters shown in the BIOS Options menu. The CD-ROM BIOS must also be en abled in order t o b oot fro m an y de vi ce (e .g., C D-ROM, tape drive) or system drive configured on the controller, or to access any DOS partition on any drive configured on the controller.
When BIOS Disable or Enable is selected, the following message will be displayed. Pressing any key will restart the system.
CD-ROM Boot Disable or Enable
The default for this option is for the CD-ROM boot to be disabled (e.g., the system will boot from a hard drive, even if there is a bootable CD installed). If the CD-ROM boot option is enabled, and if a bootable CD is installed in the CD-ROM drive, the system will boot from the CD.
If the CD-ROM boot option is enabled, the CD-ROM will take priority over the disk drives. F or e x ample, u nder MS-DOS, the disk drive that is normally Drive C will become Drive D. All subsequent drive IDs will similarly be moved forward.
Manual No. 775020 3-3
BIOS Options Sequence
Enable 2 GByte or 8 GByte Drives
This setting affects how the BIOS reads the disk drives. Drive geometries can be toggled between 2 GB and 8 GB. The default is 2 GB. When the drive geometry setting is changed, the drive must be low level formatted.
m Caution
Changing this setting after da ta has been stored will make the data unreadable. If you have already configured your array and have stored data, you should not change this setting.
The default BIOS geometry of the controller is set to 2 GB. Th is means that the operating system through the BIOS can access only the first 2 GB of any drive that has been configured on the controller. This is adequate in most applications, since BIOS is u sed only to boot the op erating sy stem. Ho we ve r , it does mean the operating system must be instal led in the first 2 GB of the capacity of the configured drive. Some operating systems are limited to a 2 GB boot partition.
If this is not adequate, th e BIOS geomet ry can be cha nged to 8 GB, allowing the operating system through the BIOS to access the first 8 GB of capacity.
3-4 AcceleRAID 150 Installation Guide
Controller Board Start-up
As a rule of thumb, select 8 GB geometry if the following three cases apply:
1. You have a system (RAID) drive that is greater than 2.145 GB in capacity.
2. The DOS/Windows compatible partitions could be located in an area above the first 2.145 GB.
Otherwise the 2 GB option is fine.
Note
In the event that the RAID controller needs to be replaced, the current drive geometry will be restored from the configuration on disk (COD).
Manual No. 775020 3-5

RAID EzAssist Configuration Utility Sequence

RAID EzAssist Configuration Utility Sequence
After the BIOS options have been set as desired, do the following:
1. Power ON the computer (or allow the computer to restart normally after the BIOS options have been set).
2. Watch the messages on the screen for the following prompt to be displayed:
Press <ALT-M> for BIOS options
3. Wait approximately 5 seconds. Do not press any keys at this time.
4. Watch the messages on the screen for the following prompt to be displayed:
Press <ALT-R> for RAID Configuration options
5. Press Alt–R to get into the BIOS Configuration Utility.
Note
For detailed information on how to run the RAID EzAssist Configuration Utility, refer to the RAID
EzAssist Configuration Utility User Reference Guide
(P/N 775029).
3-6 AcceleRAID 150 Installation Guide
Controller Board Start-up

Operating System

If an operating system is not already installed on the system, it can be installed on a system disk on the controller. The operating system is installed along with the operating system device drivers.

Installing the AcceleRAID as the Primary Controller

Follow the procedures indicated in the appropriate operating system chapter of the Disk Array Controller Software Kit User’s Manual when installing AcceleRAID along with the operating system software.
• Do NOT install the driver for the on-board Symbios Logic SCSI adapter at any time during the operating system installation.

Installing the AcceleRAID into an Existing System with a SCSI Boot Device

, WARNING
If an existing operating system is running on a SCSI boot drive using the Symbios Logic SC SI adapter embedded on the system board, the AcceleRAID controller must be installed as the
primary (boot) controller. following BEFORE installing the AcceleRAID controller:
1
You must do the
Back up all data on all SCSI devices
1. are controlled by an on-board Symbios Logic 810 SCSI device driver.
2. Shut down or exit from the operating system and run the system BIOS setup utility when prompted by pressing F2.
3. Switch to Advanced Settings.
4. Open PCI Configuration.
5. Open PCI Device, Embedded SCSI Devices.
1. This warning does not apply if the operating system is installed on an IDE device.
Manual No. 775020 3-7
(including the boot device) that

Operating System Device Drivers

6. Change the Option ROM Scan to DISABLED. Enable Master should be set to ENABLED, and Latency Timer should be at least 0040h.
7. Save the settings and exit by pressing F10.
8. At the memory check, power down the server.
Install the AcceleRAID as the primary controller as documented:
1. Install the AcceleRAID controller hardware and disk drives, and cable and terminate properly as described in Chapter 2.
2. Run RAID EzAssist according to the instructions in “RAID EzAssist Configuration Utility Sequence” on page 3-6.
3. Use the configuration utility to set up one or more disk arrays and save the configuration (RAID EzAssist Configuration Utility User Reference Guide P/N 775029).
4. Install the DAC driver for your operating system at the same time you install the operating system itself onto the array, referring to the appropriate chapter of the Disk Array Controller Software Kit Installation Guide and User Manual (P/N 771929).
5. Reboot and restore your previously backed up data to the array.
Operating System Device Drivers
Device drivers that are compatible with the controller can be found in the Software Kit. For details on how to install and load drivers, refer to the Disk Array Controller Software Kit Installation Guide and User Manual (P/N 771929) and the AcceleRAID 150 Quick Installation Guide (P/N 775024) for Windows NT and NetWare operating systems.

Global Array Manager (GAM)

The controller can be configured using GAM. GAM can also be used from the server or a system client to monitor status and verify data integrity of disks connected to the controller while the system and disks are running.
For details on how to install and run GAM, refer to the Global Array Manager Client Softw are Installation Guide and User Manual (P/N 771961). This manual can be downloaded at no cost from the Mylex web site (www.mylex.com).
3-8 AcceleRAID 150 Installation Guide
Controller Board Start-up

In Case of Problems

If problems are encountered during start-up, check the following:
• Check SCSI cabling for loose connections, pin mismatches (make sure pin 1 on the cable matches pin 1 on the connector), bent pins, and damaged or crossed cables.
• Check cable length. This includes internal bus lengths in enclosures.
• Check termination.
• Check SCSI IDs on all drives.
• Remove the system cov er, power ON the system and observe the LEDs (see Figure 3-1).
• Be sure the U1 light goes out after system is booted.
• Be sure the SE or LVD is lighted appropriately, see the table e xcer pt
following Figure 3-1 on the next page.
Manual No. 775020 3-9
In Case of Problems
• Check the LED lights when controller is installed. (See the LED section of Table 2-1, “AcceleRAID Connectors, Jumpers, and LED Descriptions,” or see the excerpt below for details.)
LVD
JP5
J2
External
Connector
(VHDCI)
J1
Internal Connector
(68-Pin High Density)
U1 SE
U1
JP1SEJP1JP1
LVD
JP4
Figure 3-1. LED Descriptions
U1 LED, ON indicates the controller card failed internal
diagnostics during start-up.
LVD (D3) LED, ON = default; the light is always ON unless a single-
SE (D2) LED, ON indicates a single-ended drive is detected.
ended device is connected. The light will turn OFF when a single-ended device is detected*.
* The LVD and SE lights will not be ON or OFF at the same time.
3-10 AcceleRAID 150 Installation Guide
Appendix A
Installation Notes

Helpful AcceleRAID Installation Notes

The purpose of this appendix is to pr ovide add itional informatio n about y our AcceleRAID 150 installation of either the Standard or SISL configuration. There are cross references to direct you to the appropriate topic in the main installation section of this manual.

SCSI Formats and Bus Lengths

Table A-1. Supported SCSI Formats and Bus Lengths
Bus
Speed,
SCSI Drive Type*
SCSI-1 5 8 6 - 8 Fast SCSI 10 8 3 - 8 Fast Wide SCSI 20 16 3 - 16 Ultra SCSI 20 8 1.5 - 8 Ultra SCSI 20 8 3 - 4 Wide Ultra SCSI 40 16 - - 16 † Wide Ultra SCSI 40 16 1.5 - 8 Wide Ultra SCSI 40 16 3 - 4 Ultra2 SC SI 40 8 Not Defined 12 8 Wide Ultra2 SCSI 80 16 Not Defined 12 16
MB/Sec,
Max.
Bus
Width,
Bits
Max. Bus Length, Meters* Max. Device
Single-ended Low-Voltage
Differential
Support
(Including
Controller)
SCSI Trade Association (STA) Terms
*
† The maximum number of devices allowed on a Wide Ultra SCSI bus is 8 unless
bus extender technology is used
Note
In order to ensure an error free environment, the proper cable designed for a certain SCSI speed must be used.
Manual No. 775020 A-1

SCSI Cabling for AcceleRAID 150 (Standard and SISL)

SCSI Cabling for AcceleRAID 150 (Standard and SISL)
An Ultra SCSI or an Ultra2 SCSI channel supports up to 15 SCSI devices. Examples of SCSI devices include hard disk, tape, and CD-ROM.
m Caution
Wide and narrow SCSI cables must not be installed together on any one channel, or the AcceleRAID controller may not work properly.
LVD Mode
The controller supports Ultra2 SCSI with LVD. If all drives attached to a controller drive channel support Ultra2 SCSI with LVD, then that channel will operate at 80 MB/sec per bandwidth with Wide Ultra2 SCSI. This setup allows a maximum SCSI bus length of up to 12 meters. See the topic about connecting the SCSI cables, on page 2-10 and on page 2-25.
Note
The SCSI bus length can be extended to 25 meters if only the controller and one drive are on the bus.
Note
Definition: The SCS I bus le ngth is def ined as the total physical distance between the terminators, including space needed for cables, connectors, and devices. (See the illustrations under the termination sections and notice the placement of the terminator “ T ” symbol indicating termination at the farthest ends of the configuration.)
Single-ended Mode
If any device on the channel is not Ultra2 SCSI capable, the channel will revert to single-ended mode. The SCSI bus lengths will then be limited to the single-ended bus lengths shown in Table A-1
A-2 AcceleRAID 150 Installation Guide
Appendix B
AcceleRAID Specifications

General Hardware Specifications

AcceleRAID

Controller DAC960PRL
CPU Intel i960 RP® RISC 32-bit microprocessor, 33MHz
Memory EDO parity memory 60ns
4 MB or 16 MB
Cache Write: Selectable, Write Through or Write Back
Error Protection: Parity
Firmware ROM Type, Flash EEPROM, 512K x 8
PCI I/O
SCSI I/O
Manual No. 775020 B-1
Processor: Embedded in Intel i960 RP microprocessor Transfer
Rate: 132 MB/second (burst)
Processor:
Number of Controller Channels
Symbios 53C895 on AcceleRAID 150. AcceleRAID supports 53C875, 53C876, 53C895, and
53C896 on system board
DAC960PRL-1 – one Ultra2 LVD channel on controller

Environmental Specifications

Environmental Specifications
Controller DAC960PRL
Temperature Operating 0°C to +50°C (+32°F to 122°F)
Storage -20°C to +60°C (-4°F to +140°F)
Humidity Oper ating 10% to 90% relative humidity (non-condensing)
Storage 10% to 90% relative humidity (non-condensing)
Altitude Operating Up to 3,048m (10,000 ft )
Storage Up to 15,240m (50,000 ft)
Form Factor Length: 7.225 inches
Width: 4.2 inches Maximum.
Mean Time Between Failure
Component Height:
Board Width:
MTBF 350,000 hours at 55° C
0.105 inches solder side
0.570 component side. Not to exceed the width of one PCI slot
[was +55°C, 131°F]
[was +70°C, 158°F]
B-2 AcceleRAID 150 Installation Guide
AcceleRAID Specifications

DAC960PRL Block Diagram (Standard)

Figure B-1 (example of a system board block diagram) shows a standard configuration to use the Mylex AcceleRAID 150 Controller with any available PCI Bus Slot on a capable system board.
CPU
PCI Interface
Control
Logic
PCI Bus Slot
PCI Bus Slot
PCI Bus Slot
PCI Bus Slot
System Board
AcceleRAID 150
DAC960PRL
Controller
RAID FW NVRAM
I960RP
Protocol
PCI Bus Slot
Figure B-1. AcceleRAID Standard System Board
Cache Memory
SCSI
Chip
Term.
Manual No. 775020 B-3

DAC960PRL Block Diagram (SISL)

DAC960PRL Block Diagram (SISL)
Figure B-2 (exampl e of a system board block di agram ) sh ows the functional relationship between the Mylex AcceleRAID 150 Controller and the SCSI­capable system board. The SCSI chip interrupt lin e(s) are routed to a PCI b us slot (shaded to indicate SISL availability) specifically preconfigured to accept the controller.
The non-shaded PCI bus slots indicate an example of available SCSI connections that are not intended for SISL activity.
AcceleRAID 150
Cache Memory
DAC960PRL
Controller
RAID FW NVRAM
I960RP
CPU
PCI Interface
Control
Logic
PCI Bus Slot
PCI Bus Slot
PCI Bus Slot
System Board
PCI Bus Slot
Interrupt Logic
PCI Slot Pre-configured for AcceleRAID
SCSI Protocol
Chip
SCSI Protocol
Chip
SCSI
Protocol
Chip
Term.
Term.
Figure B-2. AcceleRAID and SCSI-Capable System Board (SISL)
Term.
SCSI Bus
SCSI Bus
B-4 AcceleRAID 150 Installation Guide
Appendix C
AcceleRAID Error Messages

Error Messages

Start-up: Error Messages

The BIOS looks for any initialization message posted by the firmware during the start-up sequence. If a message is found, one of the following errors displays on screen and the installation process aborts.
DAC960Pn fatal error--memory test failed
n
DAC960P DAC960P DAC960P

Drive Check: Error Messages

If the firmware finds a v alid controller configuration, b ut it doesn't match the SCSI drives currently installed, one or more of the following messages display:
Unidentified device found at channel x....
Device identified for chn SCSI device at chn
If any of the above messages are displayed, the firmware will not proceed any further in the initialization process, except to find other mismatches. Then, the BIOS prints out the following:
DAC960Pn Configuration Checksum error--run configuration utility
If the firmware detects that during the last po wer c ycle the system was tu rned off abruptly leaving some incomplete write operations, the following message appears:
Recovery from mirror race in progress
The following messages may also appear:
Adapter cannot recover from mirror race! Some system drives are inconsistent!
fatal error--command interface test failed
n
hardware error--run diagnostics to pinpoint error
n
firmware checksum error--reload firmware
x
, tgt y found at chn x', tgt y'
x
, tgt y not responding
Manual No. 775020 C-1

Aborted Installation

During the initialization, if the firmware fails to respond to the BIOS inquiry within two minutes, the following message displays:
DAC960Pn not responding--no drives installed.
The BIOS then inquires the firmware for its version number and other information, and prints out the following message:
DAC960Pn firmware version
x.xx
One or more of the following messages will be displayed if the firmware reports the following conditions:
Warning: X system drives are offline Warning: Warning: The following SCSI devices are dead--chn
, tgt y...
x
No system drives found: None installed
system drives installed
X
system drives are critical
X
The BIOS repeats the same process for additional RAID controllers present in the system. Then it proceeds to boot, if possible, from the first system drive on the first controller.
Aborted Installation
With Firmware 4.x, the installation aborted message is displayed when the BIOS finds that the configuration of the disk drives, as stored in the NVRAM and configuration on disk, is different from what it senses at boot time. When this happens, (and a brand new installation is not being attempted) the cause is often a faulty cable or drive, or a loose connection. Check all of the connectors, cables, drives, and try to boot. If the error persists, it most likely indicates a genuine failure and needs to be corrected. To correct it, run the RAID EzAssist (previously BIOS) Configuration Utility (see “RAID EzAssist Configuration Utility Sequence” on page 3-6). For more information, refer to the RAID EzAssist Configuration Utility User Reference Guide (P/N 775029).
C-2 AcceleRAID 150 Installation Guide
AcceleRAID Error Messages

NVRAM Error

With Firmware 4.x, if the BIOS displays a mismatch between the NVRAM and the COD, no drives will be installed. Normally this error will not be displayed. If it is, boot and run the RAID EzAssist (previously BIOS) Configuration Utility (see “RAID EzAssist Configuration Utility Sequence” on page 3-6) to recover from the error. For more information, refer to the RAID EzAssist Configuration Utility User Reference Guide (P/N 775029).

System Reboot or Power Down

Before you power-down or reboot the system, it is very important to ma ke sure that all data is written to the disk by waiting a minimum of 15 seconds before resetting or rebooting the system.
The AcceleRAID is a caching controller with write back capability. Data may still be in the cache waiting to be written to the disk drives when the system reports that a write command was completed.
Manual No. 775020 C-3
System Reboot or Power Down
C-4 AcceleRAID 150 Installation Guide
Appendix D
Enclosure Management

Introduction

Mylex’s AcceleRAID controllers support the industry standard enclosure management protocol SCSI Accessed Fault-Tolerant Enclosures (SAF-TE). This feature allows the host to monitor drive enclosures and detect certain faults or operating environment conditions. The host can make a decision to shut down the system or issue a warning based on the type of fault detected.

SAF-TE

The SAF-TE protocol follows a specification jointly worked out by nStor Corporation and Intel Corpor ation. Enclosures that are compliant with this protocol are known as SCSI Accessed Fault-Tolerant Enclosures (SAF-TE). The protocol is compatible with standard SCSI buses and cabling.
The SAF-TE interface standard’s objective is to provide a non-proprietary means of allowing third-party disks and controllers to be automatically integrated with peripheral enclosures that support:
• Status Signals (LEDs, audible alarms, LCDs, etc.)
• Hot swapping of drives
• Monitoring of fans, power supplies, and enclosure temperature
SCSI is the underlying transport mechanism for communicating enclosure information. All standard SCSI host adapters will work. There is no need to consider reserved signals or special cabling.
The SAF-TE interface can be implemented as a SCSI target that uses a SCSI port and an 8-bit micro controller.
All communication is initiated by the host. The SAF-TE processor acts only in target mode. The SAF-TE processor should be periodically polled by the host approximately every 2 to 10 seconds.
Manual No. 775020 D-1
SAF-TE
D-2 AcceleRAID 150 Installation Guide
Appendix E
Regulatory Information

Class B Compliance

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
All external connections should be made using shielded cables. This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection a gainst harmful interference in re sidential installations. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions , may cause harmful interferen ce to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipme nt do e s cause interferen ce to radio or televisio n eq uipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Move the equipment away from the receiver.
3. Plug the equipment into an outlet on a circuit different from that to which the receiver is powered.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.
m Caution
Only equipment certified to comply with Class B (computer input/output devices, terminals, printers, etc.) should be attached to this equipment.
Any changes or modif ications to the equipm ent by the user not expressly approved by the grantee or manufacturer could void the user’s authority to operate such equipment.
Manual No. 775020 E-1

Declaration of Conformity

Per FCC Part 2, Section 2.1077(a)
Manufacturer’s Name: Manufacturer’s Address:
Mylex Corporation 34551 Ardenwood Blvd. Fremont, CA 94555-3607 USA
Declares that the product: Product Name:
Model Number(s):
AcceleRAID 150 Ultra2 SCSI RAID Controller
DAC960PRL-1
Year of Manufacture: 1998 Conforms to the following Product Specification(s): FCC:
CFR 47 Part 15, Subpart B, Section 15.107(e) and Section 15.109(g) Class B Digital Device tested per ANSI C63.4–1992 procedures
Supplementary Information:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause und e sired operation.
E-2 AcceleRAID 150 Installation Guide

Declaration of Conformity

Per 89\336\EEC
Responsible Party Name: Mylex Corporation Address: 34551 Ardenwood Boulevard
Fremont, CA 94555-3607 USA
hereby declares that the product
Regulatory Information
Trade Name:
AcceleRAID 150 Ultra2 SCSI RAID Controller
Model Number: DAC960PRL-1
conforms to the following specifications
Standards: EN 50081-1:1992, EMI
EN 55022 Class B (Radiated), Class B (Conducted)
EN 50082-1:1992, Immunity
EN 61000-4-2:1995 Electrostatic Discharge EN 61000-4-3:1996 Radiated Susceptibility EN 61000-4-4:1995 Electrical Fast Transients/Burst
Manual No. 775020 E-3

Community of Europe

CE mark is rated for the AcceleRAID 150 Ultra2 SCSI RAID Controller as follows: CISPR 22 Radiated Emission EN55022, EN5082-1 Generic immunity standard for the following:
IEC 801-2 ESD, IEC 801-3 Radiated, and IEC 801-4 EFT/Burst Warning! This is a Class B product. In a residential environment this pro duc t may cause radio
interference, in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertk lasse B. In Wohnbereichen können bei
Betrieb dieses Gerät es Rundfunkstörungen aufreten, in welche n Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Avertissement! Cet appareil est un appareil de Classe B. Dans un environnement résidentiel cet
appareil peut provoquer des brouillages radi oélectriques. Dans ce cas, il peut être demandé à l’utilisateur de prendre des mésures appropriées.

Underwriters Laboratories

E-4 AcceleRAID 150 Installation Guide

Glossary

Cache

Controller memory used to speed up data transfer to and from a disk.

Cache Flush

Refers to an operation where all unwritten blocks in a Write-Back Cache are written to the target disk. This operation is necessary before powering down the system.

Cache Line Size

The Cache Line Size function is set in conjunction with stripe size and represents the size of the data “chunk” that will be read or written at one time.

Channel

Refers to one SCSI bus on a disk array controller. Each disk array controller provides at least one channel.

Consistency Check

Refers to a process where the integrity of redundant data is verified. For example, a consistency check of a mirr ored dri ve will make sure th at the data on both drives of the mirrored pair is exactly the same.

Disk Failure Detection

The controller automatically detects SCSI disk failures. A monitoring process running on the controller checks, among other things, elapsed time on all commands issued to disks. A time-out causes the disk to be “reset” and the command to be retried. If the command times out again, the disk could be “killed” (taken “offline”) by the controller (its state changed to “dead”). DAC960 controllers also monitor SCSI bus parity errors and other potential problems. Any disk with too many errors will also be ‘killed’.
Manual No. 775020 G-1

Disk Media Error Management

When a disk reports a media error during a read, the co ntroller reads the data from the mirror (RAID 1 or 0+1), or computes th e data from the other blocks (RAID 3, RAID 5), and writes the data back to the disk that encountered the error. If the write fails (media error on write), the controller issues a “reassign” command to the disk, and then writes the data to a new location. Since the problem has been resolved, no error is reported to the system.
When a disk reports a media error during a write, the controller issues a “reassign” command to the di sk, and wri tes th e data out to a ne w locat ion on the disk.

Drive Groups (or Drive Packs)

A group of individu al disk drives (preferab ly identical) that are logically tied to each other and are addressed as a single unit. In some cases this may be called a drive “pack ” when refer ring to just the p hysical devices. Up to eight (8) drives can be configured together as one drive group.
All the physical devices in a drive group should have the same size, otherwise each of the disks in the group will effectively have the capacity of the smallest member. The total size of the drive group will be the size of the smallest disk in the group multipli e d by the number of disks in the group. For example, i f yo u h ave five disks of 400MB plus one disk of 200 MB th ey are equal to six d isk of 20 0MB of total sto rage. W ith RAID 3 o r RAID 5, on e disk’s worth of storage is dedicated to parity. Therefore, the equivalent data capacity of the array would be five disks of 200MB or 1000MB (5*200).

Hot Replacement of Disks (Hot Swap)

The design of the DAC960 Series controllers allows for the replacement of failed hard disk drives without interruption of system service. In the event of a SCSI drive failure on a properly configured system (where the data redundancy features of the controller are used), system service continues without interruption.
G-2 AcceleRAID 150 Instal la ti on Gui de
Glossary
When a replacement drive becomes available, the system operator can remove the failed disk drive, install a new disk drive, and instruct the controller to “rebuild” the data on the new drive, all without interrupting system operations.
Once the rebuild is complete, the controller will be brought back into a fault tolerant state.

Logical Drive States

The state of a logical (system) drive can be either ONLINE, CRITICAL, or OFFLINE. Notice that the same term “online” is used for both physical and logical drives.

Online: A Logical Drive is in an “online” state if...

All of its participating SCSI drives are “online.”

Critical: A Logical Drive is in a “critical” state if...

It has been configured at RAID le vel 1, 3, 5, or 0+1; and One (and only one) of its SCSI drives is not “online.” A logical drive is considered “critical” because any failure of another of its
SCSI drives may result in a loss of data.
Note
I/O operation can only be performed with system drives that are online or critical.

Offline: A Logical Drive is in an “offline” state if...

No data can be read from it or written to it. System commands issued to offline logical drives are returned with an error
status: no operations can be performed on offline logical drives. A logical drive can be “offline” under one of two situations described below:
• It is configured with a redundant RAID level (1, 3, 5, or 0+1), and two or more of its SCSI drives are not “online”; or
• It is configured at RAID level 0, JBOD, or in a spanned set, and one or more of its SCSI drives are not “online.”
Manual No. 775020 G-3

Logical Drives

See “System Drives.”

LVD – Low Voltage Differential

Low Voltage Differential is a form of SCSI signalling that was introduced with Ultra2 SCSI. Low Voltage Differential allows cable lengths of up to 12 meters (approximately 39 feet) wi th up to 15 de vices. The devices need to be Ultra2 SCSI LVD devices in order to take advantage of the LVD signalling.
LVD uses data high and data low signal lines to increase transmission distances over those of single-ended (conventional SCSI signalling). LVD differs from con v entional dif ferential signalling. LVDs advantages are that it consumes less power and it can sense single-ended devices on the bus and revert to single-ended signalling.

Mirroring

Refers to the 100 percent duplication of data on one disk drive to another disk drive. Each disk will be the mirror image of the other.

Pack

See “Drive Groups (or Drive Packs).”

Parity

See “Rotated XOR Redundancy.”
PCI
Peripheral Component Interconnect – This is a hig h-perfor mance, b ackplane interface, expansion slot architecture that is found on PCs, Macintoshes, and UNIX workstations. PCI is a standardized architecture that provides a high­speed data path between peripherals and the CPU. PCI cards are portable across hardware platforms with the help of various software drivers.
G-4 AcceleRAID 150 Instal la ti on Gui de
Glossary

RAID

RAID stands for Redundant Array of Independent Disks. The DAC 960 controllers implement this technology to connect up to 15 SCSI devices per channel. Several different forms of RAID implementation have been defined. Each form is usually referred to as a “RAID level.” All the RAID levels supported by DAC960 Series controllers are shown below.
The appropriate RAID level for a system is selected by the system manager or integrator. This decision will be based on which of the following are to be emphasized:
Disk Capacity Data Availability (redundancy or fault tolerance) Disk Performance

RAID Levels

The disk array controllers monitored by this utility support four RAID Advisory Board-approved (RAID 0, RAID 1, RAID 3, RAID 5) and two special RAID levels (RAID 0+1, and JBOD).
Level 0.
Block “striping” across mul tip le drives is provided, yielding higher performance than is possible with individual drives. This level does not provide any redundancy.
Level 1.
Drives are paired and mirrored. All data is 100 percent duplicated on a drive of equivalent size.
Level 3.
Data is “striped” across several physical drives. Maintains parity information which can be used for data recovery.
Level 5.
Data is “striped” across several physical drives. For data redundancy, drives are encoded with rotated XOR redundancy.
Level 0+1.
Combines RAID 0 striping and RAID 1 mirroring. This level
provides redundancy through mirroring. (Mylex RAID 6)
JBOD.
Sometimes referred to as “Just a Bunch of Drives.” Each drive is operated independently like a normal disk controller, or drives may be spanned and seen as a single drive. This level does not provide data redundancy. (Mylex RAID 7)
Manual No. 775020 G-5
Level 10.
multiple drive groups (super drive group). This level provides redundancy through mirroring.
Combines RAID 0 stri ping and RAID 1 m irror in g spann ed acros s
Level 30.
Maintains parity information which can be used for data recovery.
Level 50.
For data redundancy, drives are encoded with rotated XOR redundancy.
Data is “striped” across multiple drive groups ( super dri ve group ).
Data is “striped” across multiple drive groups (super drive group).
Note
The host operating system drivers and software utilities remain unchanged regardless of the level of RAID installed. The controller makes the physical configuration and RAID level implementation.

Replacement Table

A replacement table contains information regarding which SCSI devices have been replaced by other SCSI devices through standby replacement.

Rotated XOR Redundancy

This term (also known as “parity”) refers to a method of providing complete data redundancy while requiring only a fraction of the storage capacity of mirroring. In a system configur ed under RAID 5 (which require at least three SCSI drives), all data and parity blocks are divided between the drives in such a way that if any single drive is removed (or fails), the data on it can be reconstructed using the data on the remaining drives. (XOR refers to the Boolean “Exclusive-OR” operator.) In any RAID 5 array, the capacity allocated to redundancy is the equivalent of one drive.

SCSI

SCSI is an acronym for “Small Computer Systems Interface,” although it is often used in large systems. The SCSI interface supports disk drives, tape drives, and CD-ROM drives. Narrow SCSI supports up to seven (7) devices on a channel, and Wide SCSI, Ultra SCSI, and Ultra2 SCSI support up to 15 devices on a channel.
G-6 AcceleRAID 150 Instal la ti on Gui de
Glossary

SCSI Drive

A disk drive equipped with a SCSI interface (sometimes referred to as a SCSI Disk). Each disk drive will be assigned a SCSI address (or SCSI ID), which is a number fro m 0 to 7 (0 to 15 u nder wi de or Ul t ra SC SI) . T he SC SI address uniquely identifies the drive on the SCSI bus or channel.

SCSI Drive States

Refers to a SCSI driv e’ s cu rrent operational statu s. At any gi ven time, a SCSI drive can be in one of f i ve states: READY , ONLINE, STANDBY, DEAD, or REBUILD.
The controller stores the state of the attached SCSI drives in its non-volatile memory. This information is retained even after power-off. Hence, if a SCSI disk is labeled DEAD in one session, it will stay in the DEAD state un til a change is made either by using a system level utility or after a rebuild. Each of the states is described below:

Ready: A SCSI disk drive is in a “ready” state if it...

Is powered on, and Is available to be configured during the current session but remains
unconfigured.

Online: A SCSI disk drive is in an “online” state if it...

Is powered on, and Has been defined as a member of a drive group, and Is operating pr operly.

Standby: A SCSI disk drive is in a “standby” state if it...

Is powered on, and Is able to operate properly, and Was NOT defined as part of any drive group.

Dead: A SCSI disk drive is in a “dead” state if it...

Is not present, or
Manual No. 775020 G-7
If it is present but not powered on, or If it failed to operate properly and was ‘killed’ by the controller. When the controller detects a failure on a disk, it “kills” that disk by
changing its state to “dead.” A SCSI drive in a dead state does not participate in any I/O activity. No commands are issued to dead drives.

Rebuild: A SCSI disk drive is in a “rebuild” state...

While it is in the process of being rebuilt. During this process, data is regenerated and written to the disk drive. This state is also referred to as ‘Write-Only’ (WRO).

SCSI Interrupt Steering Logic

This is the architecture that allows a RAID controller, such as AcceleRAID to implement RAID on a system board embedded SCSI bus or a set of SCSI busses.

Segment Size

See “Cache Line Size”.

Session

Refers to the period of time between any two consecutiv e system shutdowns. System shutdown may be either a power OFF/ON, or a hardware reset.

SISL

See “SCSI Interrupt Steering Logic.”

Standard Disk Drive

This term refers to a hard disk drive with SCSI, IDE, or other interface, that is attached to the host system through a standard disk controller.

Standby Replacement of Disks (“Hot Spare”)

The “Standby Replacement” (or “Hot Spare”) is one of the most important features the controller provides to achie ve automatic, n on-stop service with a
G-8 AcceleRAID 150 Instal la ti on Gui de
Glossary
high degree of fault-tolerance. The rebuild operation will be carried out by the controller automatically when a SCSI disk drive fails and both of the following condit ions are true:
• A “standby” SCSI disk drive of identical size is found attached to the same controller.
• All of the system drives that are dependent on the failed disk are redundant system drives, e.g., RAID 1, RAID 3, RAID 5, RAID 0+1.
Note
The standby rebuild will only happen on the SAME DAC960 controller, never across DAC960 controllers.
A Standby or Spare disk can be created by using RAID EzAssist or Global Array Manager Client software.
During the automatic rebuild process, system activity continues as normal. System performance may degrade slightly during the rebuild process.
To use the standby rebuild feature, you should always maintain a standby (spare) disk in your sy stem. When a disk fails, the standby disk will automatically replace the failed driv e and the d ata will be rebuilt. The system administrator can disconnect and remove the bad disk and replace it with a new disk. The administrator can then make this new disk a standby.

Stripe Order

The order in which SCSI di sk drives appear within a drive group. Thi s or der must be maintained, and is critical to the controller’s ability to ‘Rebuild’ failed dri ves.

Stripe Size

The stripe size is defined as the size, in kilob ytes (1 024 b ytes) of a single I/O operation. A stripe of data (data residing in actual physical disk sectors, which are logically ordered first to last) is divided over all disks in the drive group.

Stripe Width

The number of striped SCSI drives within a drive group.
Manual No. 775020 G-9

Striping

Refers to the storing of a sequential block of incoming data across multiple SCSI drives in a group. For example, if there are 3 SCSI drives in a group, the data will be separated into blocks and block 1 of the d ata will be stored on SCSI drive 1, block 2 on SCSI drive 2, block 3 on SCSI drive 3, block 4 on SCSI drive 1, block 5 on SCSI drive 2 and so on. This storage method increases the disk system throughput by ensuring a balanced load among all drives.

System Drives

A system drive is equi valent to a “log ical” driv e. System dri v es are presented to the operating system as available disk drives, each with a capacity specified by the DAC960 Series controller.

Target ID

A target ID is the SCSI ID of a device attached to a D A C960 controller. Each SCSI channel can have up to 15 attached SCSI devices (target ID from 0 to 6, and 8 to 15).

Ultra SCSI

Ultra SCSI, or Fast 20 SCSI is a high performance SCSI protocol that has a bus speed of 20 MegaBytes per second in the Narrow SCSI configuration and 40 MegaBytes in the Wide SCSI (Fast 20 Wide SCSI) configuration.

Ultra2 SCSI

Ultra2 SCSI, or Fast 40 SCSI is a higher performance SCSI protocol than Ultra SCSI. Ultra2 SCSI has a bus speed of 40 MegaBytes per second in the Narrow SCSI configuration and 80 MegaBytes in the Wide SCSI (Wide Ultra2 SCSI) confi guration.
G-10 Accel eR AID 150 Installation Guide
Glossary

Write-Back Cache

Refers to a caching strategy whereby write operations result in a completion signal being sent to the host operating system as soon as the cache (not the disk drive) receives the data to be written. The target SCSI driv e will receive the data at a more appropriate time, in order to increase controller performance.

Write Through Cache

Refers to a caching strategy whereby d ata is written to the SCSI d rive before a completion status is returned to the host operating system. This caching strategy is considered more secure, since a power f ailure will be less likely to cause loss of data. Howe ver, a write throu gh cache results in a slightly lower performance.
Manual No. 775020 G-11
G-12 Accel eR AID 150 Installation Guide
DAC960 Problem Report
Customer Identification DACPRL-1 DACPRL-1 Identification
Name:___________________________________ Date: Purchase Date: Company:________________________________ Model Address: _________________________________ Invoice Number:
________________ ___ __ _________________ __ Serial Number: ________________________________________ # Chnls: Cache:
Country: _________________________________ Firmware Ver: BIOS Ver:
Make/Model/Size/Type of Phone Number:____________________________ Drives: Fax Number:______________________________ Disk:
Non-Disk:
System Information
Motherboard: ____________ CPU Speed: BIOS Ver: Video Adapter: ___________ Network Card: MB Memory: Operating Sys: ___________ Other Disk Ctrl: Other Cards:
Pack Configuration System Drive Configuration
Indicate in matrix below 1, 2... for member of pack 1, pack 2... respective­ly. Indicate S, T, C, or O for Standby, Tape, CDROM and other drives.
Chan-
nel
0123456789101112131415 1 02 13 24
SCSI ID
Problem Description
_____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________
This DPR form has been inclu ded with your Mylex product as a co nvenience to both you and our Tec hnical Services Department. If filled out completely, this will greatly assist Mylex personnel in quickly resolving any technical problems or questions you may have. Use the Mylex fax number (510) 745-7715 to transm it this form to the Technical Services Department, or mail to Mylex Corporation, Technical Services Department, 34551 Ardenwood Blvd., Fremont, CA 945 55-3607
System
Drive
0
5 6 7
Size RAID
Level
Write Back/
Thru
772014-DAC960
Mylex Warranty - Customer Policy
Thank you for pu rchasing this Mylex product fo r your comput er system. I n addition to this high-qu ality produc t, your purchase entitl es you to the warranty coverage set forth herein. In order to provide this warranty coverage, and to indicate yo ur ac cept ance of this warr an ty, we must have the att ache d Warranty Registrat ion Ca rd com ple ted and returned to us within 15 days of your pu rchase . Also, in or der for us to provide you the hi ghest level of service, we must know where you purchased your MYLEX product.
Three Year Limited Warranty
If at any time during the thirty six month period immediately following the date of original purchase of the MYLEX product enclosed herewith (the “PRODUCT”) you discover one or more defects in the material or workma nship, MYLEX will repair, or at MYLEX’s sole option, replace the PRODUCT. If the PRODUCT fails to operate at any time within seven days after the date of its original purchase, it will be replaced by MYLEX. Such repair or replace­ment will be your sole remedy against MYLEX, and MYLEX’s only liabi li ty to you, for any failure or m al function of the PRODUCT. The warranty set forth in this paragraph will be void if:
1. The PRODUCT has been installed in an i mproper manner or in an impr oper operating environment.
2. The PRODUCT has been modified or repaire d by any party other than MYLEX or a MY LE X fac tory authorized service center.
3. The PRODUCT has been damaged.
Some MYLEX products will have a Warranty Expiration Date label affixed to the produ ct it self. Wh en pre sent, the warranty period will extend through the last day of the month indicated.
This warranty will not a ppl y t o, a nd MYLEX provides no warranty for, any BIOS, software, ROM-based firmware, or any other PRODUCT developed or manufactured by any third party, whether included with this PRODUCT or not. Such warranty o r warranties as are pr ovided by third parties, t o the extent permit ted thereby, shall be made available, and are hereby assigned, by MYLEX to the purchaser of this PRODUCT.
If MYLEX issues a revision to the BIOS, firmware or software included with this PRODUCT within 30 days of your purchase, MYLEX will replace such firmware at no charge except handling fees.
Out of Warranty Service
Mylex products which are inel igible for warranty service may be serviced by MYLEX according to our standard price list, as mod ified from time to time. A curr ent copy of the st andard pric e list is available from the Technical Support Department.
Limitation of MYLEX Liability
MYLEX’s liability arising from the sale, use and disposition of this PRODUCT shall in no event exceed the amount paid to MYLEX for this PRODUCT. MYLEX assumes no liability for damages aris ing from the use or failure of any MYLEX product. The WARRANY DESCRIBED ABOVE CONSTITUTES THE ONLY WARRANY MADE BY MYLEX. MYLEX EXPRESSLY DISCLAIMS ANY AND ALL OTHER WA RRANTIES OF ANY KIND WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANT­ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY EXCLUDED. IN NO EVENT WILL MYLEX BE LIABLE FOR INCIDENTAL, SPECIAL OR CONSEQUEN­TIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OF DATA, USE, OR INCOME), EVEN IF ADVISED OF SUCH DAMAGES IN ADVANCE. Your sole remedies shall be as provided herein.
P/N: 772058-03 6-98 Printed in U.S.A.
Returned Merchandise Procedures
If you suspect that there i s a de fect i n the mate rial or workma nship of this PRODUCT, you should contact the per­son or company from which you purc hased it. That person or company ma y be able to solve the problem and if not, will be able to contac t us for technical assistance or repair.
If it is determined that the PRODUCT must be returned to MYLEX for repair or replacement, contact MYLEX’s Technical Support Department at 510-608-2 400 before it is returned. Each retur ned item must have a separate Return Merchandise Authorization (RMA) number, provided by MYLEX.
The following rules apply to all returned items:
1. The PRODUCT must be returned eithe r in its origin al packagin g or in othe r packagi ng which is a ppropria te for the PRODUCT and the manner of shipment, and the RMA number must be displayed prominently on the outside of each such packag e.
2. If a PRODUCT is determined to be i neligi ble for warrant y serv ice, the cust omer wi ll be no tified before any fu r­ther action is taken with the PRODUCT.
3. MYLEX will not be responsible for any loss or damage to property shi ppe d with t he RMA PRODUCT not origi­nally sold by MYLEX (e.g., coprocessor chips, periphera l boards, memory modules, enclosures, power supplies, or any other accessories or attached items).
4. Any item returned to MYLEX without a valid RMA number will be retu rned to the shipper. Products shipped to MYLEX must be shipped or mailed at the shipper’s risk, freight prepaid, to the address bel ow.
Mylex Corporation 34551 Ardenwood Blvd.
Fremont, California U.S.A.
94555-3607
Mylex will pay for return freight via such carrier as MYLEX shall de em appropriate.
Technical Support
MYLEX’s Technical Support Depar tment, to assist yo u in resol ving probl ems with MY LEX p roducts, is available through the world wid e web. Contact the Technical Support web site throu gh the Mylex Internet home pa ge at www.mylex.com, or by e-mail at support@mylex.com . In the U.S.A., the Technical Support Department ca n be reached by telephone at (510) 608-2400 or by FAX at (510) 745-7715. Current hours of operation, which are subject to change, are from 6:00 a.m. to 6:00 p.m. Pacific Time, Mondays through Fridays, excluding U.S.A. national hol-
idays.
Included with the shi pment of most MYLEX products is a System Pro blem Report (SPR) form. When conta cting the Technical Support Department fo r assista nce with a n in stall ation or c omp atibi lity proble m, we recom men d that this form be complet ed and sent by facsimile or mail to MYLEX. Completion of t his form will allow our Technical Support Department to solve most technical problems exped it io usly.
Mylex will make reasonable e fforts to address compa tibility proble ms which ma y arise with respe ct to third pa rty products, but shall not be responsible for the compa tibi li ty of its products with the products of any third party. Cus­tomers are advised to verify each products compatibility with their installation before committing to any particular procurement plan.
CorporateOffices
Tel:510.796.6100 SalesFax:510.745.8016 www.mylex.com
EuropeanSales
Tel:44.1344.302200 Fax:44.1344.301100 www.mylex.com
34551 Ardenwood Blvd., Fremont, CA94555-3607, USA
●●
P.O. Box 513, Great Missenden, Bucks HP 16 OPG, United Kingdom
● ●
Loading...