Using the Boxed Intel® Xeon Processor and
Boxed Intel
®
Server Board SE7501CW2
Intel Server Board SE7501CW2 Installation and Integration Guide
Revision History
Date Revision Notes Product Code
9/25/03 1 First Draft
10/6/03 2 Second Draft
Disclaimers
The information contained in this document is provided for informational purposes only and represents the current
view of Intel Corporation (“Intel”) and its contributors (“Contributors”) as of the date of publication. Intel and the
Contributors make no commitment to update the information contained in this document, and Intel reserves the
right to make changes at any time, without notice.
DISCLAIMER
REPRESENTATIONS OF ANY KIND WITH RESPECT TO PRODUCTS REFERENCED HEREIN, WHETHER SUCH
PRODUCTS ARE THOSE OF INTEL, THE CONTRIBUTORS, OR THIRD PARTIES. INTEL, AND ITS CONTRIBUTORS
EXPRESSLY DISCLAIM ANY AND ALL WARRANTIES, IMPLIED OR EXPRESS, INCLUDING WITHOUT LIMITATION, ANY
WARRANTIES OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, NON-INFRINGEMENT, AND ANY
WARRANTY ARISING OUT OF THE INFORMATION CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION, ANY
PRODUCTS, SPECIFICATIONS, OR OTHER MATERIALS REFERENCED HEREIN. INTEL, AND ITS CONTRIBUTORS DO
NOT WARRANT THAT THIS DOCUMENT IS FREE FROM ERRORS, OR THAT ANY PRODUCTS OR OTHER TECHNOLOGY
DEVELOPED IN CONFORMANCE WITH THIS DOCUMENT WILL PERFORM IN THE INTENDED MANNER, OR WILL BE
FREE FROM INFRINGEMENT OF THIRD PARTY PROPRIETARY RIGHTS, AND INTEL, AND ITS CONTRIBUTORS
DISCLAIM ALL LIABILITY THEREFOR.
INTEL, AND ITS CONTRIBUTORS DO NOT WARRANT THAT ANY PRODUCT REFERENCED HEREIN OR ANY PRODUCT
OR TECHNOLOGY DEVELOPED IN RELIANCE UPON THIS DOCUMENT, IN WHOLE OR IN PART, WILL BE SUFFICIENT,
ACCURATE, RELIABLE, COMPLETE, FREE FROM DEFECTS OR SAFE FOR ITS INTENDED PURPOSE, AND HEREBY
DISCLAIM ALL LIABILITIES THEREFOR. ANY PERSON MAKING, USING OR SELLING SUCH PRODUCT OR
TECHNOLOGY DOES SO AT HIS OR HER OWN RISK.
Licenses may be required
trademarks, copyrights or other intellectual proprietary rights covering subject matter contained or described in
this document. No license, express, implied, by estoppels or otherwise, to any intellectual property rights of Intel
or any other party is granted herein. It is your responsibility to seek licenses for such intellectual property rights
from Intel and others where appropriate.
Limited License Grant
internal distribution only. You may not distribute this document externally, in whole or in part, to any other person
or entity.
LIMITED LIABILITY
OTHER THIRD PARTY, FOR ANY LOST PROFITS, LOST DATA, LOSS OF USE OR COSTS OF PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES, OR FOR ANY DIRECT, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES
ARISING OUT OF YOUR USE OF THIS DOCUMENT OR RELIANCE UPON THE INFORMATION CONTAINED HEREIN,
UNDER ANY CAUSE OF ACTION OR THEORY OF LIABILITY, AND IRRESPECTIVE OF WHETHER INTEL, OR ANY
CONTRIBUTOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. THESE LIMITATIONS SHALL
APPLY NOTWITHSTANDING THE FAILURE OF THE ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
Intel, Intel NetBurst, Intel Xeon, Intel i960, Intel Inside and the Intel logos are trademarks or registered trademarks of
Intel Corporation or its subsidiaries in the United States and other countries.
Installing the Intel SMaRT Tool ............................................................. 24
4
Intel Server Board SE7501CW2 Installation and Integration Guide
Introduction
Document Overview
This guide outlines the procedures for integrating an
®
Intel
Server Platform using an Intel Server Board
SE7501CW2 and Intel Xeon processors.
This guide consists of the most essential information
first-time server builders need to successfully
assemble an Intel server solution. Your particular
operating system’s installation guide will cover the
installation of the server’s operating system.
Target Audience
Intel channel program members who are expanding their expertise to include server
platforms and current channel program members looking for a refresher on servers
System integrators deploying servers based on the boxed Intel Server Board
SE7501CW2
Our intent is to better enable system integrators, particularly first-time server builders, to
meet the competitive challenges they face in the server market and to keep program
members up-to-date on emerging server technologies. By following the steps outlined in
this document, you will be able to integrate an Intel Server Board SE7501CW2 with an Intel
Server Chassis SC5200 in a timely and effective manner.
The Intel Server Chassis SC5200 is used as an example and is recommended for ease of
integration and compatibility; other reference chassis may be different. Expanded
installation instructions and complete product information are available in the IntelBoard SE7501CW2 Product Guide on the Resource CD. Unless otherwise noted, references
to the Intel Server Chassis SC5200 include both the base version and the base redundant
power version.
®
Server
Thank you
Thank you for buying Intel Server Products.
5
Intel Server Board SE7501CW2Installation and Integration Guide
Troubleshooting Guide
In the unlikely event you do encounter issues, the troubleshooting guide will help you
troubleshoot and identify possible areas of concern regarding the Intel Server Board
SE7501CW2. It will also assist you in collecting the data needed to help you work through
any concerns or issues that may arise The troubleshooting guide includes suggestions that
may help you and a list of information that we will need to assist you should you need to
call. The troubleshooting guide is available at:
If you are unable to resolve a problem using this guide, please follow these steps:
1. Visit http://support.intel.com/support/motherboards/server/SE7501CW2/index.htm
This Web site contains the latest information on known issues and their respective
solutions. If you are still unable to resolve the issue, go to the next step.
2. Send e-mail, including as much information on the issue as possible, to Intel customer
support, using the form available at this URL:
3. Channel customers can contact Intel customer support toll free at 1-866-655-6565.
Non-channel customers should use one of the numbers listed at
http://www.intel.com/support/9089.htm
.
Minimum Hardware Requirements
Your system must meet the following minimum requirements to avoid integration difficulties
and possible board damage:
•Processor: Minimum of one Intel Xeon processor 1.8 GHz with 512K cache support in
a 603-pin (400-MHz FSB) or 604-pin (533-MHz FSB) INT flip-chip micro pin-grid array
(INT-mPGA). For a list of tested processors, visit
•Power: Minimum of 450 W with 1.2A standby current which meets the SSI EPS 12V
specification. Intel provides a power budgeting tool to help you determine the power
needs of your server at
Additional resources and support for your server board, including tested chassis, qualified
chassis components, specifications, and software updates, can be found at
Intel Server Board SE7501CW2 Installation and Integration Guide
Hardware Integration
The following installation procedures enable you to prepare a
chassis for integration, add the needed components to your
server board, and install the server board. The procedures are
condensed from the more comprehensive and detailed Product
Guides for the Intel Server Board SE7501CW2 and Intel Server
Chassis SC5200. To access the most current and complete
Product Guides and for more information, visit Intel Support at:
2. Prepare a clean, static-controlled, level workstation.
3. Collect and organize all necessary hardware including the server board, memory,
processor(s), and peripherals (hard drives, floppy disk drive, CD/DVD).
4. Verify that the components chosen for installation are listed as validated for use with the
Intel Server Board SE7501CW2. This information is available from the Intel Support Web
site: http://support.intel.com/support/motherboards/server/SE7501CW2/compat.htm
.
7
Intel Server Board SE7501CW2Installation and Integration Guide
Important Safety Information
Safety Instructions and Information
To avoid personal injury or property damage, the following safety instructions apply
whenever working inside the chassis:
1. Turn off all peripheral devices connected to this product.
2. Turn off the system by pressing the power button on the front of the product.
3. Disconnect the AC power by unplugging all AC power cords from the system or wall
outlet.
4. Disconnect all cables and telecommunication lines that are connected to the system.
5. Retain all screws or other fasteners when removing access cover(s). When finished,
refasten the access cover with original screws or fasteners.
6. Do not access the inside of the power supply. There are no serviceable parts in the
power supply. If the power supply is malfunctioning, return it to the manufacturer for
servicing.
Electrostatic Discharge (ESD)
CAUTION
Perform the procedures in this product guide only at an electrostatic discharge (ESD)
workstation, because the server components are extremely sensitive to ESD. If no such
workstation is available, you can reduce the risk of electrostatic discharge damage by doing
the following:
• Wear an antistatic wrist strap, and attach it to a metal part of the server.
• Touch the metal on the server chassis before touching the server components.
• Keep part of your body in contact with the metal server chassis to dissipate the static
charge while handling the components.
• Avoid moving around unnecessarily.
• Hold the server components (especially boards) only by the edges.
• Place the server components on a grounded, static-free surface. Use a conductive foam
pad if available. Do not use the product packaging or wrapper as an antistatic surface.
•Do not slide the components over any surface.
8
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.