Intel® Storage System SSR316MJ2
Cable Kit (FMJCABLES2)
Installation Guide
Order Number: D27073-002
Disclaimer
Information in this document is provided in connection with Intel
otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions
of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating
to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability,
or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or
authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of
the Intel
product could create a situation where personal injury or death may occur. Intel may make changes to
specifications and product descriptions at any time, without notice.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
*
Other names and brands may be claimed as the property of others.
products. No license, express or implied, by estoppel or
Important Safety Instructions
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
See Intel Server Boards and Server Chassis Safety Information at
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine
der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu IntelServerplatinen und -Servergehäusen unter
Server Boards and Server Chassis Safety Information
服务器主板与服务器机箱安全信息》)。
(《Intel
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document
avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information rendez-vous sur le site
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en
Storage system power on/off: The push-button on/off power switch on the
front panel of the storage system does not turn off the AC power. To remove
AC power from the storage system, you must unplug the AC power cord
from either the power supply or wall outlet.
Hazardous conditions—power supply: Hazardous voltage, current, and
energy levels are present inside the power supply enclosure. There are no
user-serviceable parts inside the power supply; servicing should only be done
by technically qualified personnel.
Hazardous conditions—devices and cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the storage system and disconnect telecommunications systems,
networks, modems, and the power cord attached to the storage system before
opening it. Failure to do so can result in personal injury or equipment
damage.
Avoid injury: Lifting the storage system chassis and attaching it to the rack
is a two-person job. If needed, use an appropriate lifting device. A fully
loaded Intel® Storage System SSR316MJ2 weighs approximately 31.8 kg
(70 lbs.).
CAUTIONS
Temperature: The operating temperature of the storage system, when
installed in an equipment rack, must not go below 5° C (41° F) or rise above
35° C (95° F). Extreme fluctuations in temperature can cause a variety of
problems in the storage system.
Ventilation: The equipment rack must provide sufficient airflow to the front
of the storage system to maintain proper cooling. It must also include
ventilation sufficient to exhaust a maximum of 1900 BTUs per hour for a
fully loaded Intel® Storage System SSR316MJ2.
Intel® Storage System SSR316MJ2 Cable Kit iv
Contents
About the Cable Kit ............................................................................................. 9
Figure 30. Disconnecting Front Panel Cables....................................................................... 39
Figure 31. Removing System Fan Assembly Screws ........................................................... 40
Figure 32. Disconnecting System Fan Cables...................................................................... 41
Figure 33. Removing System Fan Assembly ........................................................................42
Figure 34. Disconnecting I
Figure 35. Connecting I
Figure 36. Installing System Fan Assembly .......................................................................... 45
Figure 37. Attaching System Fan Assembly ......................................................................... 46
Figure 38. Connecting System Fan Cables ..........................................................................47
Figure 39. Connecting Front Panel Board Cables ................................................................48
Figure 40. Installing the Chassis Cover ................................................................................49
2
C Cables....................................................................................... 16
2
C Cables ......................................................................................... 22
2
C Cables..................................................................................... 43
2
C Cables ......................................................................................... 44
Intel® Storage System SSR316MJ2 Cable Kit vii
Intel® Storage System SSR316MJ2 Cable Kit viii
About the Cable Kit
Enclosed is your new Intel® FMJCABLES2 Cable Kit. This document describes how to install the
cables included in this kit into the Intel
®
Storage System SSR316MJ2.
Kit Contents
The FMJCABLES2 Cable Kit consists of the following:
One bundle of four 21-inch SATA cables, type A
One bundle of four 25-inch SATA cables, type B
One bundle of four 28-inch SATA cables, type C
One bundle of four 32-inch SATA cables, type D
Two Intel® FMJCABLES2 IDE cables
One Intel® FMJCABLES2 Front Panel cable
Two Intel® FMJCABLES2 I
1. Review the safety information and warnings at the beginning of this guide.
2. Power down your Intel® Storage System Console. See letter “A” in
3. Remove both AC power cords from the AC power inputs at the rear of your storage system.
See letter “B” in
Figure 1.
4. Loosen the two thumb screws at the rear of the chassis cover. See letter “C” in
5. Facing the front of the chassis, push the top cover rearward, and then lift it up to remove it. See
letter “D” in
Figure 1.
Figure 1.
Figure 1.
B
C
D
C
A
®
Intel
Storage System SSR316MJ2 Cable Kit 10
Figure 1. Removing Chassis Cover
TP01797
SATA Cables Installation Procedures
Unseat Hard Disk Drive Carriers
CAUTION
The steps below do not require removing hard disk drive carriers from
the storage system. You need only disengage the carriers. If you choose
to remove the drive carriers from the storage system, first note the
location of each drive carrier. You must later reinstall each drive carrier
into the same location from which it was removed. See the IntelSystem SSR316MJ2 Quick Start User’s Guide for details.
1. Press down on the hard disk drive handle release mechanisms to unlatch the handle on the hard
disk drive carriers. See letter “A” in
Figure 2.
2. Rotate the hard disk drive and hard disk drive carrier handles downward. See letter “B” in
Figure 2.
3. Slide the hard disk drives and hard disk drive carriers at least halfway out of the hard disk drive
bays. See letter “C” in
Figure 2. It is not necessary to completely remove the hard disk drives
from the bays. See the caution message above.
®
Storage
A
B
C
TP01798
Figure 2. Unseating Hard Disk Carriers
®
Intel
Storage System SSR316MJ2 Cable Kit 11
SATA Cables Installation Procedures
Disconnect Front Panel Cables
1. Disconnect the front panel cable, labeled J1, from the front panel board. See letter “A” in
Figure 3.
2. Disconnect the secondary IDE cable, labeled J3, from the front panel board. See letter “B” in
Figure 3.
3. Disconnect the primary IDE cable, labeled J5, from the front panel board. See letter “C” in
Figure 3.
4. Disconnect the front panel power connector from the front panel board. See letter “D” in
Figure 3.
A
B
C
Figure 3. Disconnecting Front Panel Cables
D
TP01799
®
Intel
Storage System SSR316MJ2 Cable Kit 12
SATA Cables Installation Procedures
Remove Fan Assembly Screws
Use a Number 1 size Phillips* screwdriver to remove the screw on each side of the system. See
letter “A” in
screws will be re-installed later.
Figure 4. These screws hold the system fan assembly in place. See Figure 4. These
A
Figure 4. Removing System Fan Assembly Screws
TP01800
®
Intel
Storage System SSR316MJ2 Cable Kit 13
SATA Cables Installation Procedures
Disconnect Fan Cables
1. Disconnect the Fan 3 cable from the server board. See letter “A” in Figure 5.
2. Disconnect the Fan 4 cable from the server board. See letter “B” in
3. Disconnect the Fan 5 cable from the server board. See letter “C” in
B
A
C
A
Figure 5.
Figure 5.
B
C
Figure 5. Disconnecting System Fan Cables
TP01801
®
Intel
Storage System SSR316MJ2 Cable Kit 14
SATA Cables Installation Procedures
Remove Fan Assembly and Disconnect SATA Cables
1. Simultaneously pull up on both sides of the system fan assembly to remove the fan assembly
from the storage system. See letter “A” in
surface.
2. Remove the 16 SATA cable connectors from the two SATA Host Bus Adapter cards located
inside the chassis at the rear of the system. See letter “B” in Figure 6.
A
Figure 6. Set the system fan assembly on a static-free
B
A
TP01802
Figure 6. Removing System Fan Assembly and Disconnecting SATA Cables
®
Intel
Storage System SSR316MJ2 Cable Kit 15
Loading...
+ 34 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.