It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Refer to Model Description Chart to match the pump material options.
637397 for air section repair (see page 6).
637401-XX for fluid section repair (see page 4). NOTE:This kit also con-
tains several air motor seals which will need to be replaced.
637395-X major air valve assembly (see page 7).
PUMP DATA
Modelssee Model Description Chart for “-XXX”..............
Pump TypeMetallic Air Operated Double Diaphragm..........
Materialsee Model Description Chart..............
WeightPM10A
Maximum Air Inlet Pressure120 p.s.i.g. (8.3 bar).........
Maximum Material Inlet Pressure10 p.s.i.g. (0.69 bar).....
Maximum Outlet Pressure120 p.s.i.g. (8.3 bar)..........
Maximum Particle Size1/8” dia. (3.3 mm)............
Maximum Temperature Limits (diaphragm / ball / seal material)
E.P.R. / EPDM-60_ to 280_ F(-51_ to 138_ C).........
Polypropylene35_ to 175_ F(2_ to 79_
SantopreneR-40_ to 225_ F(-40_ to 107_ C)..........
PTFE40_ to 225_ F(4_ to 107_ C)...............
Dimensional Datasee page 8................
Mounting Dimension4”x 6.25”(101.6 mm x 158.8 mm)........
Noise Level @ 70 p.s.i., 60 c.p.m.80.6 db(A)
Thepump sound pressure levels published here have been updated to an Equivalent
Continuous Sound Level (L
ROP S5.1 using four microphone locations.
NOTICE: All possible options are shown in the chart, however, certain
combinations may not be recommended, consult a representative or the
factory if you have questions concerning availability.
-CSS-XXX-A0244.84 lbs (20.3 kgs)......
-CSS-XXX-A0238.2 lbs (17.3 kgs)...
PM10R
-CSS-XXX-A0251.64 lbs (23.4 kgs)...
PM10S
(flooded inlet)52.2 g.p.m. (197.6 l.p.m.)....
Aeq
.........
{.....
) to meet the intent of ANSI S1.13-1971, CAGI-PNEU-
C)
Center Section Material
A - Aluminum
R - Polypropylene
S - Stainless Steel
Fluid Connection
C - 1-1/2” Tri-Clamp
Fluid Caps & Manifold Material
S - Stainless Steel
Hardware Material
S - Stainless Steel
Seat Material
A - Santoprene
S - 316 Stainless Steel
Ball Material
A - Santoprene
T - PTFE
Diaphragm Material
A - Santoprene
M - Medical Grade Santoprene
T - PTFE / Santoprene
FLUID SECTION SERVICE KIT SELECTION
EXAMPLE: Model # PM10A-CSS-AAA-A02
Fluid Section Service Kit # 637401-AA
PM10X-X-X-A02
RELEASED:2-28-05
REVISED:5-19-10
(REV. 06)
07)
MODEL DESCRIPTION CHART
PM10 X -C S S -X X X -A02
PM10X - CSS - X X X -A02
637401 - X X
DiaphragmBall
11-11-10
Figure 1
INGERSOLL RAND COMPANY LTD
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 43506-0151
(800) 276-4658 D FAX (800) 266-7016
fluids.ingersollrand.com
E2008CCN 15207673
OPERATING AND SAFETY PRECAUTIONS
S
S
R
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE
STATIC SPARK
WARNING
al injury, pump damage or property damage.
EXCESSIVE AIR PRESSURE. Can cause person-
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
S Do not exceed the maximum inlet air pressure as stated on the
pump model plate.
S Be sure material hoses and other components are able to with -
stand fluid pressures developed bythis pump. Check all hoses
for damage or wear. Be certain dispensing device is clean and
in proper working condition.
WARNING
severe injury or death. Ground pump and pumping system.
Sparks can ignite flammable material and vapors.
The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or spraying flammable materials such as paints, solvents, lacquers,
etc. or used in a location where surrounding atmosphere is
conducive to spontaneous combustion. Ground the dispensing valve or device, containers, hoses and anyobject to which
material is being pumped.
STATIC SPARK. Can cause explosion resulting in
S Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.
S Consult local building codes and electrical codes for specific
grounding requirements.
S Aftergrounding, periodicallyverify continuity of electrical path
to ground. Test with an ohmmeter from each component (e.g.,
hoses, pump, clamps, container, spray gun, etc.) to ground to
insure continuity. O hmmeter should show 0.1 ohms or less.
S Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid freestreaming
of material being dispensed.)
S Use hoses incorporating a static wire.
S Use proper ventilation.
S Keep inflammables away from heat, open flames and sparks.
S Keep containers closed when not in use.
S In the event of a diaphragm rupture, material can be forced out
of the air exhaust muffler.
S Pipe the exhaust to a safe remote locationwhen pumping haz-
ardous or inflammable materials.
S Use a grounded 3/8” minimum i.d. hose between the pump and
the muffler.
WARNING
injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.
HAZARDOUS PRESSURE. Can result in serious
S Disconnect air supply line and relieve pressure from the sys-
tem by opening dispensing valve or device and / or carefully
and slowly loosening and removing outlet hose or piping from
pump.
WARNING
jury or property damage.Do not attempt to return apump to the
factory or service center that contains hazardous material.
Safe handling practices must comply with local and national
HAZARDOUSMATERIALS.Can cause serious in-
laws and safety code requirements.
S Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.
WARNING
num parts cannot be used with 1,1,1-trichloroethane, methylene chloride or other halogenated hydrocarbon solvents
which may react and explode.
EXPLOSION HAZARD. Models containing alumi-
S Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using withsolvents
of this type.
WARNING
containing aluminum wetted parts with food products for human consumption. Plated parts can contain trace amounts of
lead.
CAUTION
wetted parts and the substance being pumped, flushed or recirculated. Chemical compatibility may change with temperature and concentration of the chemical(s) within the
substances being pumped, flushed or circulated. For specific
fluid compatibility, consult the chemical manufacturer.
CAUTION
cal stress only. Certain chemicals will significantly reduce
maximum safe operating temperature. Consult the chemical
manufacturer for chemical compatibility and temperature limits.RefertoPUMPDATAonpage1ofthismanual.
CAUTION
been trained for safe working practices, understand it’s limitations, and wear safety goggles / equipment when required.
CAUTION
the piping system. Be certain the system components are
properly supported to prevent stress on the pump parts.
MISAPPLICATION HAZARD. Do not use models
Verify the chemical compatibility of the pump
Maximum temperatures are based on mechani-
Be certain all operators of this equipment have
Do not use the pump for the structural support of
S Suction and discharge connections should be flexible connec-
tions (such as hose), not rigid piped, andshould be compatible
with the substance being pumped.
CAUTION
not allow pump to operate whenout ofmaterial forlong periods
of time.
Prevent unnecessary damage to the pump. Do
S Disconnect air line from pump when system sits idle for long
periods of time.
CAUTION
assure compatible pressure rating and longest service life.
NOTICE
TION. Creep of housing and gasket materials may cause fasteners to loosen. Re -torque all fasteners to insure against fluid
or air leakage
WARNING
CAUTION
NOTICE
Use only genuine ARO
RE-TORQUEALL FASTENERSBEFORE OPERA-
= Hazards or unsafe practices which could
result in severe personal injury, death or
substantial property damage.
= Hazards or unsafe practices which could
result in minor personal injury, product
or property damage.
= Important installation, operation or
maintenance information.
replacement parts to
PM10X-XXX-XXX-A02 (en)Page 2 of 8
GENERAL DESCRIPTION
OPERATING INSTRUCTIONS
The ARO diaphragm pump offers high volume delivery even at low air
pressure and a broad range of material compatibility options available.
Refer to the model and option chart. ARO pumps feature stall resistant
design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differential in
the air chambers to alternately create suction and positive fluid pressure
in the fluid chambers, ball checks insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to
pump and keep up with the demand. It will build and maintain line pressure and will stop cycling once maximum line pressure is reached (dispensing device closed) and will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING
damage, personal injury or property damage.
EXCESSIVE AIR PRESSURE. Can cause pump
S A filter capable of filtering out particleslarger than 50 microns should
be used on the air supply.There is no lubrication required other than
the “O” ring lubricant which is applied during assembly or repair.
S If lubricated air is present, makesure thatit is compatible with the“O”
rings and seals in the air motor section of the pump.
INSTALLATION
S
Verify correct model / configuration prior to installation.
S Retorque all external fasteners per specifications prior to start up.
S Pumps are tested in water at assembly. Flush pump with compatible
fluid prior to installation.
S When the diaphragm pump is used in a forced-feed (flooded inlet)
situation, it is recommended that a “Check Valve” be installed at the
air inlet.
S Material supply tubing should be at least the same diameter as the
pump inlet manifold connection.
S Material supply hose must be reinforced, non-collapsible type com-
patible with the material being pumped.
S Piping must be adequately supported. Do not use the pump to sup-
port the piping.
S Use flexible connections (such as hose) at the suction and dis-
charge. These connections should not be rigid piped and must be
compatible with the material being pumped.
S Secure the diaphragm pump legs to a suitable surface (level and
flat) to insure against damage by vibration.
S Pumps that need to be submersed must have both wet and non-wet
components compatible with the material being pumped.
S Submersed pumps must have exhaust pipe above liquid level. Ex-
haust hose must be conductive and grounded.
S Flooded suction inlet pressure must not exceed 10 p.s.i.g. (0.69
bar).
S
Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to “setting up”
when not in use for a period of time.
S Disconnect the air supply from the pump if it is to be inactive for a few
hours.
PARTS AND SERVICE KITS
Refer to the part viewsand descriptions as provided on page 4through 7
for parts identification and Service Kit information.
S Certain ARO “Smart Parts” areindicated which should be available
for fast repair and reduction of down time.
S Service kits are divided to service two separate diaphragm pump
functions:1.AIRSECTION,2.FLUIDSECTION.TheFLUIDSECTION is divided further to match typical part MATERIAL OPTIONS.
MAINTENANCE
S
Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service
disassembly and reassembly.
S Keep good records of service activity and include pump in preven-
tive maintenance program.
S Before disassembling, empty captured material in the outlet man-
ifold by turning the pump upside down to drain material from the
pump.
2. Remove (22) balls, (19 and 33) “O” rings (if applicable) and (21)
seats.
3. Remove (15) fluid caps.
NOTE: Only PTFE diaphragm models use a primary diaphragm (7) and
a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section
illustration.
4. Remove the (14) screw, (6) diaphragm washer, (7) or (7 / 8) diaphragms, and (5) backup washer.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.
FLUID SECTION REASSEMBLY
S
Reassemble in reverse order. Refer to the torque requirements on
page 5.
S Clean and inspect all parts. Replace worn or damaged parts with
new parts as required.
S Lubricate (1) diaphragm rod and (144) “U” cup with LubriplateR
FML-2 grease (94276 grease packet is included in service kit).
S For modelswith PTFE diaphragms: Item(8) Santoprene diaphragm
is installed with the side marked “AIR SIDE”towards the pump center body. Install the PTFE diaphragm (7) with the side marked
“FLUID SIDE” towards the (15) fluid cap.
S Re-check torque settings after pump hasbeen re-startedand runa
while.
S SantopreneR is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P., S LubriplateR is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) S
S LoctiteR and 242R are registered trademarks of Henkel Loctite Corporation S AROR is a registered trademark of Ingersoll-Rand Company S
S 271t is a trademark of Henkel Loctite Corporation S
Page 3 of 8PM10X-XXX-XXX-A02 (en)
Loading...
+ 5 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.