Ingersoll-Rand PF20R-X-B User Manual

OPERATOR’S MANUAL
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
2” DIAPHRAGM PUMP
1:1 RATIO FLAP VALVE (METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Refer to Model Description Chart to match the pump material options. 637369 for air section repair (see page 6). 637310-XX for fluid section repair (see page 3). 637374 major air valve assembly (see page 7).
PUMP DATA
Models see Model Description Chart for “-XXX”... Pump Type Metallic, Air Operated, Double Diaphragm, Flap Valve Material see Model Description Chart... Weight PF20X-XC
PF20X-XS
Maximum Air Inlet Pressure 120 p.s.i.g. (8.3 bar).........
Maximum Material Inlet Pressure 10 p.s.i.g. (0.69 bar).....
Maximum Outlet Pressure 120 p.s.i.g. (8.3 bar)..........
Maximum Flow Rate 172 g.p.m. (651 l.p.m.)..............
Displacement / Cycle @ 100 p.s.i.g. 1.4 gal. (5.3 lit.)...
Maximum Particle Size 2” dia. (51 mm) semi-solids............
Maximum Temperature Limits (diaphragm / flap / bumper material)
E.P.R. / EPDM -60_ to 280_ F(-51_ to 138_ C)...........
Nitrile 10_ to 180_ F(-12_ to 82_ C).................
Polyurethane 10_ to 150_ F(-12_ to 66_ C)............
SantopreneR -40_ to 225_ F(-40_ to 107_ C)...........
PTFE 40_ to 225_ F(4_ to 107_ C).................
VitonR -40_ to 350_ F(-40_ to 177_ C)................
Dimensional Data see page 8................
Mounting Dimension 9-1/16” x 10-1/16” (230 mm x 256 mm).....
Noise Level @ 70 p.s.i., 60 c.p.m.
{ Tested with 67263 muffler assembly installed.
The pump sound pressure levels published here have been updated to an Equivalent Continuous
|
Sound Level (L crophone locations.
) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four mi-
Aeq
X-SXX-B 178.7 lbs (81.1 kgs)... .....
X-SXX-B 180.6 lbs (81.9 kgs).....
{ 85.0 db(A)|....
AIR MOTOR / AIR CAP MATERIAL
R - Polypropylene / Stainless Steel Y - Polypropylene / Cast Iron
THREAD
A - N.P.T.F. B - BSP
FLUID CAPS & MANIFOLD MATERIAL
C-CastIron S - Stainless Steel
HARDWARE MATERIAL
P - Plated Steel S - Stainless Steel
PF20R-X-B
RELEASED: 12-14-04 REVISED: 5-5-10 (REV. 03)
Figure 1
MODEL DESCRIPTION CHART
PF20 X -X X X -S X X -B
INGERSOLL RAND COMPANY
209 NORTH MAIN STREET  BRYAN, OHIO 43506
(800) 276-4658 D FAX (800) 266-7016
www.ingersollrandproducts.com
E2010 CCN 15227671
SEAT MATERIAL
S - Stainless Steel
FLAP MATERIAL
A - E.P.R. U - Polyurethane G - Nitrile V - Viton
DIAPHRAGM MATERIAL
A - Santoprene T - PTFE / Santoprene G - Nitrile V - Viton
FLUID SECTION SERVICE KIT SELECTION
EXAMPLE: MODEL # PF20R-ACP-SAA-B FLUID SECTION SERVICE KIT # 637310-AA
PF20X - XXX - S X X -B
637310 - X X
DiaphragmFlap
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE STATIC SPARK
WARNING
al injury, pump damage or property damage.
EXCESSIVE AIR PRESSURE. Can cause person-
HAZARDOUS MATERIALS HAZARDOUS PRESSURE
S Do not exceed the maximum inlet air pressure as stated on the
pump model plate.
S Be sure material hoses and other components are able to with-
stand fluid pressures developed by this pump. Check all hoses for damage or wear. Be certain dispensing device is clean and in proper working condition.
WARNING
severe injury or death. Ground pump and pumping system.
STATIC SPARK. Can cause explosion resulting in
S Use the pump grounding screw terminal provided. Use ARO
part no. 66885-1 ground kit or connect a suitable ground wire (12 ga. min.) to a good earth ground source.
S Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.
S Consult local building codes and electrical codes for specific
grounding requirements.
S Aftergrounding, periodicallyverify continuity of electrical path
to ground. Test with an ohmmeter from each component (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity. O hmmeter should show 0.1 ohms or less.
S Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid free streaming of material being dispensed.)
S Use hoses incorporating a static wire. S Use proper ventilation. S Keep inflammables away from heat, open flames and sparks. S Keep containers closed when not in use.
WARNING
causesevere injury.Pipe exhaust away fromwork areaand per­sonnel.
Pump exhaust may contain contaminants. Can
S In the event of a diaphragm rupture, material can be forced out
of the air exhaust muffler.
S Pipe the exhaust to a safe remote locationwhen pumping haz-
ardous or inflammable materials.
S Use a grounded 1” minimum i.d. hose between the pump and
the muffler.
WARNING
injury or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized.
HAZARDOUS PRESSURE. Can result in serious
S Disconnect air supply line and relieve pressure from the sys-
tem by opening dispensing valve or device and / or carefully and slowly loosening and removing outlet hose or piping from pump.
WARNING
jury or property damage.Do not attempt to return apump to the factory or service center that contains hazardous material. Safe handling practices must comply with local and national laws and safety code requirements.
HAZARDOUSMATERIALS.Can cause serious in-
S Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.
WARNING
num wetted parts cannot be used with III.-Trichloroethane,Me­thylene Chloride or other Halogenated Hydrocarbon solvents which may react and explode.
EXPLOSION HAZARD. Models containing alumi-
S Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using withsolvents of this type.
WARNING
containing aluminum wetted parts with food products for hu­man consumption. Plated parts can contain trace amounts of lead.
CAUTION
wetted parts and the substance being pumped, flushed or re­circulated. Chemical compatibility may change with tempera­ture and concentration of the chemical(s) within the substances being pumped, flushed or circulated. For specific fluid compatibility, consult the chemical manufacturer.
CAUTION
cal stress only. Certain chemicals will significantly reduce maximum safe operating temperature. Consult the chemical manufacturer for chemical compatibility and temperature lim­its.RefertoPUMPDATAonpage1ofthismanual.
CAUTION
been trained for safe working practices, understand it’s limita­tions, and wear safety goggles / equipment when required.
CAUTION
the piping system. Be certain the system components are properly supported to prevent stress on the pump parts.
MISAPPLICATION HAZARD. Do not use models
Verify the chemical compatibility of the pump
Maximum temperatures are based on mechani-
Be certain all operators of this equipment have
Do not use the pump for the structural support of
S Suction and discharge connections should be flexible connec-
tions (such as hose), not rigid piped, andshould be compatible with the substance being pumped.
CAUTION
not allow pump to operate whenout ofmaterial forlong periods of time.
Prevent unnecessary damage to the pump. Do
S Disconnect air line from pump when system sits idle for long
periods of time.
CAUTION
sure compatible pressure rating and longest service life.
NOTICE
request: “Static Spark & Diaphragm Rupture” pn \ 94080.
WARNING
CAUTION
NOTICE
Use only genuine ARO replacement parts to as-
Replacement warning labels are available upon
= Hazards or unsafe practices which could
result in severe personal injury, death or substantial property damage.
= Hazards or unsafe practices which could
result in minor personal injury, product or property damage.
= Important installation, operation or main-
tenance information.
PF20R-X-BPage 2 of 8
GENERAL DESCRIPTION
MAINTENANCE
The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections. Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and positive fluid pressure in the fluid chambers, flap checks insure a positive flow of fluid. Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres­sure and will stop cycling once maximum line pressure is reached (dis­pensing device closed) and will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING
damage, personal injury or property damage.
EXCESSIVE AIR PRESSURE. Can cause pump
S A filter capable of filtering out particleslarger than 50 microns should
be used on the air supply.There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
S If lubricated air is present, make sure that it is compatible with the
Nitrile “O” rings in the air motor section of the pump.
OPERATING INSTRUCTIONS
S Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
S Disconnect the air supply fromthe pump if it is to be inactive for a few
hours.
S The outlet material volume is governed not only by the air supply but
also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
S When the diaphragm pump is used in a forced-feed (flooded inlet)
situation, it is recommended that a “Check Valve” be installed at the air inlet.
S Secure the diaphragm pump legs to a suitable surface to insure
against damage by vibration.
S Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service disassembly and reassembly.
S Keep good records of service activity and include pump in preven-
tive maintenance program.
S Before disassembling, empty captured material in the outlet man-
ifold by turning the pump upside down to drain material from the pump.
FLUID SECTION DISASSEMBLY
1. Remove (61) top manifold, (60) bottom manifold and (53) manifold elbow.
2. Remove the flap valve cartridge / seat assemblies.
3. Remove (15) fluid caps.
NOTE: Only PTFE diaphragm models use a primary diaphragm (7) and a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section illustration.
4. Remove the (6) diaphragm washer, (7) diaphragm and (5) backup washer.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.
FLUID SECTION REASSEMBLY
S Reassemble in reverse order. Refer to the torque requirements on
page 5.
S Clean and inspect all parts. Replace worn or damaged parts with
new parts as required.
S Lubricate (1) diaphragm rod and (144) “U” cup with LubriplateR
FML-2 grease (94276 grease packet is included in service kit).
S For modelswith PTFE diaphragms: Item (8) Santoprene diaphragm
is installed with the side marked “AIRSIDE” towards the pumpcen­ter body. Install the PTFE diaphragm (7) with the side marked “FLUID SIDE” towards the (15) fluid cap.
S Re-check torque settings after pump hasbeen re-startedand runa
while.
PARTS AND SERVICE KITS
Refer to the part viewsand descriptions as provided on page 4 through 7 for parts identification and Service Kit information.
S Certain ARO “Smart Parts” areindicated which should be available
for fast repair and reduction of down time.
S Service kits are divided to service two separate diaphragm pump
functions:1.AIRSECTION,2.FLUIDSECTION.TheFLUIDSEC­TION is divided further to match typical part MATERIAL OPTIONS.
SantopreneR is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. S LubriplateR is a registered trademark of Lubriplate Division (Fiske Brothers)
VitonR is trademark of the DuPont Company, S KynarR is a registered trademark of Penwalt Corp.
Page 3 of 8PF20R-X-B