OPERATOR’S MANUAL PD07X-X-X
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
3/4" DIAPHRAGM PUMP
1:1 RATIO (METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Refer to Model Description Chart to match the pump mate-
rial options.
637427-XX for uid section repair (see page 4).
637428 for air section repair (see page 6).
PUMP DATA
Models . . . . . . . . . . . . . see Model Description Chart for “-XXX”
Pump Type . . . . . . . . . Air Operated Double Diaphragm
Material . . . . . . . . . . . . see Model Description Chart
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.74 lbs (3.96 kgs)
Maximum Air Inlet Pressure . . . . . . . . 100 p.s.i.g. (6.9 bar)
Maximum Material Inlet Pressure . . . 10 p.s.i.g. (0.69 bar)
Maximum Outlet Pressure . . . . . . . . . . 100 p.s.i.g. (6.9 bar)
Air Consumption @ 40 p.s.i. . . . . . . . 1 c.f.m. / gallon (approx.)
Maximum Flow Rate
( ooded inlet)
. . . 13.6 g.p.m. (51.5 l.p.m.)
Displacement / Cycle @ 100 p.s.i.g. . 0.030 gal. (0.11 lit.)
Maximum Particle Size . . . . . . . . . . . . . 3/32” dia. (2.4 mm)
Maximum Temperature Limits (diaphragm / ball / seat
material)
Hytrel® . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Polypropylene . . . . . . . . . . . . 35° to 175° F (2° to 79° C)
Santoprene® . . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)
PTFE . . . . . . . . . . . . . . . . . . . . . 40° to 225° F (4° to 107° C)
Dimensional Data . . . . . . . . . . . . . . . . . . . see page 8
Noise Level @ 70 p.s.i., 60 c.p.m. . . . . . . 75.0 db(A)
c
MODEL DESCRIPTION CHART
Center Section Material
R - Polypropylene
Fluid Connection
A - 3/4 - 14 N.P.T.F. - 2
B - Rp 3/4 (3/4 - 14 BSP, parallel)
RELEASED: 2-20-07
REVISED: 5-21-10
(REV. 04)
Figure 1
PD07R - X A S - X X X
The pump sound pressure levels published here have been updated to
c
an Equivalent Continuous Sound Level (L
S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.
NOTICE: All possible options are shown in the chart, however, certain
combinations may not be recommended, consult a representative or
the factory if you have questions concerning availability.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET -- BRYAN, OHIO 43506
(800) 495-0276 y FAX (800) 892-6276
www.ingersollrandproducts.com
) to meet the intent of ANSI
Aeq
© 2010 CCN 15275290
Fluid Cap & Manifold Material
A - Aluminum
Hardware Material
S - Stainless Steel
Seat Material
F - Aluminum
P - Polypropylene
Ball Material
A - Santoprene
C - Hytrel
T - PTFE
Diaphragm Material
A - Santoprene
C - Hytrel
T - PTFE / Santoprene
Fluid Section Service Kit Selection
EXAMPLE: Model #PD07R-AAS-PCC
Fluid Section Service Kit # 637427-CC
PD07R - XAS - X X X
637427 - X X
Ball Diaphragm
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE
STATIC SPARK
WARNING
EXCESSIVE AIR PRESSURE. Can cause personal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as
y
stated on the pump model plate.
Be sure material hoses and other components are
y
able to withstand fluid pressures developed by this
pump. Check all hoses for damage or wear. Be certain
dispensing device is clean and in proper working condition.
WARNING
STATIC SPARK. Can cause explosion resulting in severe injury or death. Ground pump and
pumping system.
Use the pump ground lug provided. Connect to a 12
y
ga. (minimum) wire (kit is included) to a good earth
ground source.
Sparks can ignite ammable material and vapors.
y
The pumping system and object being sprayed must
y
be grounded when it is pumping, ushing, recirculating or spraying flammable materials such as paints,
solvents, lacquers, etc. or used in a location where
surrounding atmosphere is conducive to spontaneous
combustion. Ground the dispensing valve or device,
containers, hoses and any object to which material is
being pumped.
Secure pump, connections and all contact points to
y
avoid vibration and generation of contact or static
spark.
Consult local building codes and electrical codes for
y
speci c grounding requirements.
After grounding, periodically verify continuity of
y
electrical path to ground. Test with an ohmmeter
from each component (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity.
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or
y
device in the material being dispensed if possible.
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
y
Use proper ventilation.
y
Keep in ammables away from heat, open ames and
y
sparks.
Keep containers closed when not in use.
y
WARNING
Pump exhaust may contain contaminants.
Can cause severe injury. Pipe exhaust away from work
area and personnel.
In the event of a diaphragm rupture, material can be
y
forced out of the air exhaust mu er.
Pipe the exhaust to a safe remote location when
y
pumping hazardous or in ammable materials.
Use a grounded 3/8” minimum i.d. hose between the
y
pump and the mu er.
WARNING
HAZARDOUS PRESSURE. Can result in serious injury or property damage. Do not service or
clean pump, hoses or dispensing valve while the system is pressurized.
Disconnect air supply line and relieve pressure from
y
the system by opening dispensing valve or device and
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
/ or carefully and slowly loosening and removing outlet hose or piping from pump.
WARNING
HAZARDOUS MATERIALS. Can cause serious
injury or property damage. Do not attempt to return
a pump to the factory or service center that contains
hazardous material. Safe handling practices must
comply with local and national laws and safety code
requirements.
Obtain Material Safety Data Sheets on all materials
y
from the supplier for proper handling instructions.
WARNING
EXPLOSION HAZARD. Models containing
aluminum wetted parts cannot be used with 1,1,1-trichloroethane, methylene chloride or other halogenated hydrocarbon solvents which may react and
explode.
Check pump motor section, uid caps, manifolds and
y
all wetted parts to assure compatibility before using
with solvents of this type.
CAUTION
Verify the chemical compatibility of the
pump wetted parts and the substance being pumped,
flushed or recirculated. Chemical compatibility may
change with temperature and concentration of the
chemical(s) within the substances being pumped,
ushed or circulated. For speci c uid compatibility,
consult the chemical manufacturer.
CAUTION
Maximum temperatures are based on
mechanical stress only. Certain chemicals will signi cantly reduce maximum safe operating temperature.
Consult the chemical manufacturer for chemical compatibility and temperature limits. Refer to PUMP DATA
on page 1 of this manual.
CAUTION
Be certain all operators of this equipment
have been trained for safe working practices, understand it’s limitations, and wear safety goggles / equipment when required.
CAUTION
Do not use the pump for the structural support of the piping system. Be certain the system components are properly supported to prevent stress on
the pump parts.
Suction and discharge connections should be flex-
y
ible connections (such as hose), not rigid piped,
and should be compatible with the substance being
pumped.
CAUTION
Prevent unnecessary damage to the pump.
Do not allow pump to operate when out of material
for long periods of time.
Disconnect air line from pump when system sits idle
y
for long periods of time.
CAUTION
Use only genuine ARO® replacement parts
to assure compatible pressure rating and longest service life.
NOTICE
Install the pump in the vertical position.
The pump may not prime properly if the balls do not
check by gravity upon start-up.
NOTICE
Re-torque all fasteners before operation.
Creep of housing and gasket materials may cause
fasteners to loosen. Re-torque all fasteners to insure
against uid or air leakage.
NOTICE
Replacement warning labels are available
upon request: “Static Spark” pn \ 93616-1, Diaphragm
Rupture” pn \ 93122.
Page 2 of 8 PD07X-X-X (en)
WARNING
= Hazards or unsafe practices which
could result in severe personal injury,
death or substantial property damage.
CAUTION
= Hazards or unsafe practices which
could result in minor personal injury,
product or property damage.
NOTICE
= Important installation, operation or
maintenance information.
GENERAL DESCRIPTION
The ARO diaphragm pump o ers high volume delivery even
at low air pressure and a broad range of material compatibility options are available. Refer to the model and option chart.
ARO pumps feature stall resistant design, modular air motor
/ uid sections.
Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and
a positive fluid pressure in the fluid chambers, ball checks
insure a positive ow of uid.
Pump cycling will begin as air pressure is applied and it will
continue to pump and keep up with the demand. It will build
and maintain line pressure and will stop cycling once maximum line pressure is reached (dispensing device closed) and
will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING
damage, personal injury or property damage.
A filter capable of filtering out particles larger than 50
y
microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which
is applied during assembly or repair.
If lubricated air is present, make sure that it is compatible
y
with the “O” rings and seals in the air motor section of the
pump.
EXCESSIVE AIR PRESSURE. Can cause pump
OPERATING INSTRUCTIONS
Always flush the pump with a solvent compatible with
y
the material being pumped if the material being pumped
is subject to “setting up” when not in use for a period of
time.
Disconnect the air supply from the pump if it is to be in-
y
active for a few hours.
The outlet material volume is governed not only by the
y
air supply, but also by the material supply available at the
inlet. The material supply tubing should not be too small
or restrictive. Be sure not to use hose which might collapse.
When the diaphragm pump is used in a forced-feed
y
( ooded inlet) situation, it is recommended that a “check
valve” be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to
y
insure against damage by vibration.
MAINTENANCE
Certain ARO “Smart Parts” are indicated which should be
y
available for fast repair and reduction of down time.
Provide a clean work surface to protect sensitive internal
y
moving parts from contamination from dirt and foreign
matter during service disassembly and reassembly.
Keep good records of service activity and include the
y
pump in preventive maintenance program.
Service kits are available to service two separate dia-
y
phragm pump functions: 1. AIR SECTION, 2. FLUID SECTION. The Fluid Section is divided further to match typical
active Material Options.
Before disassembling, empty captured material in the
y
outlet manifold by turning the pump upside down to
drain material from the pump.
Hytrel® is registered trademarks of the DuPont Company y Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.
y
PD07X-X-X (en) Page 3 of 8
Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Re ning Company) y ARO® is a registered trademark of Ingersoll-Rand Company
y
y
y