Ingersoll-Rand AF06XX-01, AF10XX-01, AF12XX-01, AF04XX-01, AF08XX-01 User Manual

OPERATOR’S MANUAL 67442
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
SELF-RELEIVING BALL VALVE REGULATOR
THIS ACCESSORY IS USED WITH THE FOLLOWING AIR MOTORS
AF04XX-01 AF06XX-01 AF08XX-01 AF10XX-01 AF12XX-01
READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
RELEASED: 4-13-10 (REV. 01)
GENERAL DESCRIPTION
ARO regulators provide controlled, consistent air pressure required for the operation of a pneumatic actuated motor and any coupled system. The integrated ball valve enables the op­erator to easily throttle the motor/system from an o position to the preset desired regulator pressure. In turn the operator can also throttle from a full run position to an off condition and control the positioning of the motor/system. The ball valve also enables the operator to safely depressurize the mo­tor/system without disconnecting the supply air line
.
REGULATOR DATA
Model. . . . . . . . . . . . . . 67442
Air Inlet Port . . . . . . . 1/2 - 14 NPT
Maximum Air Inlet Pressure . . . . . . . . Refer to Air Inlet
PMAX found on model plate of pump/ air motor
Operating Temprature Range. .
Maximum Air Flow . . . . . . . . . . . . . . . . .
23 F to 175 F (-5 C to 79 C)
215 SCFM (101 dm3/s)
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276 FAX(800) 892-6276
www.ingersollrandproducts.com
© 2010 CCN 15335425
OPERATING AND SAFETY PRECAUTIONS
CAUTION
disconnect air supply and relieve material pressure before attempting to service.
High pressure equipment – Always
INSTALLATION
Install the 67442 self- relieving ball valve regulator us-
1. ing the three (11) bolts passing through the (1) regulator housing. Be certain that the (26) O-ring is in the recess groove on the mounting side of the (1) regulator hous­ing to establish the pneumatic seal. Tighten all (11) bolts evenly to 50-60 in-lbs (13.6-20.3 Nm)
2.
The (39) adjustment knob should be turned counter­clockwise until compression is released from the pressure control spring. This prevents over pressurizing the air op­erated equipment when the air supply is turned on .
3.
The (8) ball valve control handle should be turned clock­wise until it stops. This will be in the de-pressurize / vent position of the control handle. The (8) handle position is adjustabe to eight di erent locations and can be adjust­ed by removing the (10) button head screw, (9) washer, and (8) control handle and oriented as desired. The (7) key should not be removed. The (7) key establishes the on/ o /vent orientation of the ball valve.
4.
Connect piping to Air inlet port using pipe thread seal­ant on male threads only. Do not allow sealant to enter interior of regulator.
5
Air line piping should be the same size as regulator
.
ports.
.
OPERATION
Regulator
Pull (39) knob to adjust air pressure.
1.
2. Turn clockwise to increase air pressure.
3. Turn counterclockwise to decrease air pressure.
4. Push (39) knob to lock.
Ball Valve
Move the (8) control handle counterclockwise to pres-
1. surize the system. A 90 degree movement would be the “o ” position. A 90 – 180 degree movement would allow the system to be throttled to full regulated line pressure (180 degree counterclockwise position being the “on” position) .
2. Move the (8) control handle clockwise to either stop the system or to de-pressurize the system. A 90 degree movement would return to the “off” position. A 90 – 180 degree movement would allow the system to be de-pressurized and vent the residual system pressure through the (6) vent nut and dump to atmosphere (180 degree clockwise position being “vent” position).
PARTS AND MAINTENANCE
When the life of the product has expired, it is recommended that the product be disassembled, degreased and parts separated by material so that they can be recycled. The original language of this manual is English. Refer all communications to the nearest Ingersoll Rand O ce or Distributor.
Page 2 of 4 67442
Loading...
+ 2 hidden pages