Ingersoll-Rand 66M2X0-XXX-C User Manual

OPERATOR’S MANUAL 66M2X0-XXX-C
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
2" DIAPHRAGM PUMP
1:1 RATIO (METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Refer to Model Description Chart to match the pump material op-
tions. 637434 for air section repair (see page 6). 637468-XX for  uid section repair (see page 4).

PUMP DATA

Models . . . . . . . . . . . . . . . . . see Model Description Chart for “-XXX”
Pump Type . . . . . . . . . . . . . Metallic Air Operated Double Diaphragm
Material . . . . . . . . . . . . . . . . see Model Description Chart
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74.15 lbs (33.63 kgs)
Maximum Air Inlet Pressure . . . . . . . . . . . 120 p.s.i.g. (8.3 bar)
Maximum Material Inlet Pressure . . . . . . 10 p.s.i.g. (0.69 bar)
Maximum Outlet Pressure . . . . . . . . . . . . . 120 p.s.i.g. (8.3 bar)
Maximum Flow Rate ( ooded inlet) . . . 156 g.p.m. (590.5 l.p.m.)
Displacement / Cycle @ 100 p.s.i.g. . . . . 1.02 gal. (3.86 lit.)
Maximum Particle Size . . . . . . . . . . . . . . . . 3/4” dia. (19.1 mm)
Maximum Temperature Limits (diaphragm / ball / seal material)
E.P.R. / EPDM . . . . . . . . . . . . . . . . . . . -60° to 280° F (-51° to 138° C)
Hytrel® . . . . . . . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Nitrile . . . . . . . . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)
Santoprene® . . . . . . . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)
Viton® . . . . . . . . . . . . . . . . . . . . . . . . . . -40° to 350° F (-40° to 177° C)
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . see page 8
Noise Level @ 70 p.s.i., 60 c.p.m.c . . . . . . 85.3 db(A)
Noise Level @ 70 p.s.i., 60 c.p.m.e . . . . . . 105.3 db(A)
Tested with 94810 mu er assembly installed.
c
The pump sound pressure levels published here have been updated to
d
an Equivalent Continuous Sound Level (L S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.
Tested with 97116 housing and 97110-2 ball installed. Hearing protec-
e
tion is recommended when operating this product.
NOTICE: All possible options are shown in the chart, however, certain combinations may not be recommended, consult a representative or the factory if you have questions concerning availability.
The original language of this manual is English.
d
d
) to meet the intent of ANSI
Aeq
Center Body Material / Fluid Connection
5 - Aluminum / 2 - 11-1/2 NPTF - 2 7 - Aluminum / Rp 2 (2 - 11 BSP parallel)
Fluid Cap & Manifold Material / Hardware
0 - Aluminum / Carbon steel
Seat Material
1 - Aluminum
Ball Material
2 - Nitrile C - Hytrel E - Santoprene
Diaphragm Material
2 - Nitrile 9 - Hytrel B - Santoprene
Fluid Section Service Kit Selection
Example: Model #66M250-1EB-C Fluid Section Service Kit # 637468-EB

MODEL DESCRIPTION CHART

RELEASED: 10-22-08 REVISED: 2-16-09 (REV. 03)
Figure 1
66M2 X 0 - X X X - C
66M2X0 - X X X - C
637468 - X X
Ball Diaphragm
INGERSOLL RAND COMPANY LTD
P.O. BOX 151 y ONE ARO CENTER y BRYAN, OHIO 43506-0151
(800) 276-4658 y FAX (800) 266-7016
 uids.ingersollrand.com

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE STATIC SPARK
WARNING
injury, pump damage or property damage. Do not exceed the maximum inlet air pressure as stated on
y
the pump model plate. Be sure material hoses and other components are able to
y
withstand  uid pressures developed by this pump. Check all hoses for damage or wear. Be certain dispensing device is clean and in proper working condition.
WARNING
severe injury or death. Ground pump and pumping system. Sparks can ignite  ammable material and vapors.
y
The pumping system and object being sprayed must be
y
grounded when it is pumping,  ushing, recirculating or spray­ing flammable materials such as paints, solvents, lacquers, etc. or used in a location where surrounding atmosphere is conducive to spontaneous combustion. Ground the dispens­ing valve or device, containers, hoses and any object to which material is being pumped. Use the pump grounding screw terminal provided. Use ARO®
y
part no. 66885-1 ground kit or connect a suitable ground wire (12 ga. minimum) to a good earth ground source. Secure pump, connections and all contact points to avoid
y
vibration and generation of contact or static spark. Consult local building codes and electrical codes for spe-
y
ci c grounding requirements. After grounding, periodically verify continuity of electrical
y
path to ground. Test with an ohmmeter from each compo­nent (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity. Ohmmeter should show 0.1 ohms or less. Submerse the outlet hose end, dispensing valve or device
y
in the material being dispensed if possible. (Avoid free streaming of material being dispensed.) Use hoses incorporating a static wire.
y
Use proper ventilation.
y
Keep inflammables away from heat, open flames and
y
sparks. Keep containers closed when not in use.
y
WARNING
cause severe injury. Pipe exhaust away from work area and personnel. In the event of a diaphragm rupture, material can be forced
y
out of the air exhaust mu er. Pipe the exhaust to a safe remote location when pumping
y
hazardous or in ammable materials. Use a grounded 3/4” minimum i.d. hose between the pump
y
and the mu er.
WARNING
injury or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized. Disconnect air supply line and relieve pressure from the
y
system by opening dispensing valve or device and / or carefully and slowly loosening and removing outlet hose or piping from pump.
WARNING
EXCESSIVE AIR PRESSURE. Can cause personal
STATIC SPARK. Can cause explosion resulting in
Pump exhaust may contain contaminants. Can
HAZARDOUS PRESSURE. Can result in serious
HAZARDOUS MATERIALS. Can cause serious in-
HAZARDOUS MATERIALS HAZARDOUS PRESSURE
jury or property damage. Do not attempt to return a pump to the factory or service center that contains hazardous material. Safe handling practices must comply with local and national laws and safety code requirements. Obtain Material Safety Data Sheets on all materials from
y
the supplier for proper handling instructions.
WARNING
minum parts cannot be used with 1,1,1-trichloroethane, methylene chloride or other halogenated hydrocarbon solvents which may react and explode. Check pump motor section, fluid caps, manifolds and all
y
wetted parts to assure compatibility before using with sol­vents of this type.
WARNING
containing aluminum wetted parts with food products for human consumption. Plated parts can contain trace amounts of lead.
CAUTION
wetted parts and the substance being pumped,  ushed or recirculated. Chemical compatibility may change with tem­perature and concentration of the chemical(s) within the substances being pumped, flushed or circulated. For spe­ci c  uid compatibility, consult the chemical manufacturer.
CAUTION
stress only. Certain chemicals will signi cantly reduce max­imum safe operating temperature. Consult the chemical manufacturer for chemical compatibility and temperature limits. Refer to PUMP DATA on page 1 of this manual.
CAUTION
been trained for safe working practices, understand it’s limitations, and wear safety goggles / equipment when re­quired.
CAUTION
the piping system. Be certain the system components are properly supported to prevent stress on the pump parts. Suction and discharge connections should be  exible con-
y
nections (such as hose), not rigid piped, and should be compatible with the substance being pumped.
CAUTION
not allow pump to operate when out of material for long periods of time. Disconnect air line from pump when system sits idle for
y
long periods of time.
CAUTION
sure compatible pressure rating and longest service life.
NOTICE
request: “Static Spark (93616-1) & Diaphragm Rupture” (93122).
WARNING
EXPLOSION HAZARD. Models containing alu-
MISAPPLICATION HAZARD. Do not use models
Verify the chemical compatibility of the pump
Maximum temperatures are based on mechanical
Be certain all operators of this equipment have
Do not use the pump for the structural support of
Prevent unnecessary damage to the pump. Do
Use only genuine ARO replacement parts to as-
Replacement warning labels are available upon
= Hazards or unsafe practices which
could result in severe personal injury, death or substantial property damage.
CAUTION
= Hazards or unsafe practices which
could result in minor personal injury, product or property damage.
NOTICE
= Important installation, operation or
maintenance information.
Page 2 of 8 66M2X0-XXX-C (en)

GENERAL DESCRIPTION

MAINTENANCE

The ARO diaphragm pump o ers high volume delivery even at low air pressure and a broad range of material compatibility options are available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor /  uid sections. Air operated double diaphragm pumps utilize a pressure di eren­tial in the air chambers to alternately create suction and a positive  uid pressure in the  uid chambers, valve checks insure a positive  ow of  uid. Pump cycling will begin as air pressure is applied and will continue to pump and keep up with the demand. It will build and maintain line pressure and will stop cycling once maximum line pressure is reached (dispensing device closed) and will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING
age, personal injury or property damage.
A  lter capable of  ltering out particles larger than 50 microns
y
should be used on the air supply. There is no lubrication re-
quired other than the “O” ring lubricant which is applied during
assembly or repair.
If lubricated air is present, make sure that it is compatible with
y
the “O” rings and seals in the air motor section of the pump.
EXCESSIVE AIR PRESSURE. Can cause pump dam-

OPERATING INSTRUCTIONS

Always  ush the pump with a solvent compatible with the ma-
y
terial being pumped if the material being pumped is subject to
“setting up” when not in use for a period of time.
Disconnect the air supply from the pump if it is to be inactive
y
for a few hours.
The outlet material volume is governed not only by the air sup-
y
ply, but also by the material supply available at the inlet. The
material supply tubing should not be too small or restrictive.
Be sure not to use hose which might collapse.
When the diaphragm pump is used in a forced-feed ( ooded
y
inlet) situation, it is recommended that a “check valve” be in-
stalled at the air inlet.
Secure the diaphragm pump legs to a suitable surface to insure
y
against damage by vibration.
Refer to the part views and descriptions as provided on pages 4 through 7 for parts identi cation and service kit information.
Certain ARO “Smart Parts” are indicated which should be avail-
y
able for fast repair and reduction of down time. Service kits are divided to service two separate diaphragm
y
pump functions: 1. AIR SECTION, 2. FLUID SECTION. The Fluid Section is divided further to match typical part Material Op­tions. Provide a clean work surface to protect sensitive internal mov-
y
ing parts from contamination from dirt and foreign matter dur­ing service disassembly and reassembly. Keep good records of service activity and include the pump in
y
preventive maintenance program. Before disassembling, empty captured material in the outlet
y
manifold by turning the pump upside down to drain material from the pump.

FLUID SECTION DISASSEMBLY

Remove top manifold(s).
1. Remove (22) balls, (19) “O” rings and (21) seats.
2. Remove (15)  uid caps.
3.
4. Remove the (14) screw, (6) washer, (7) diaphragm and (5) wash­er.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.

FLUID SECTION REASSEMBLY

Reassemble in reverse order.
y
Clean and inspect all parts. Replace worn or damaged parts
y
with new parts as required. Lubricate (1) diaphragm rod and (2) “O” ring with Key-Lube “O”
y
ring lube. Use ARO pn / 98931-T bullet (installation tool) to aid in installa-
y
tion of (2) “O” ring on (1) diaphragm rod. Be certain (7) diaphragms align properly with (15)  uid caps be-
y
fore making  nal torque adjustments on bolt and nuts to avoid twisting the diaphragms. Re-check torque settings after the pump has been re-started
y
and run a while.
Hytrel® and Viton® are registered trademarks of the DuPont Company y Loctite® is a registered trademark of Henkel Loctite Corporation
Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. y ARO® is a registered trademark of Ingersoll-Rand Company
y
66M2X0-XXX-C (en) Page 3 of 8
y
262™, 271™ and 572™ are trademarks of Henkel Loctite Corporation
y
y
y
y
Loading...
+ 5 hidden pages