Ingersoll-Rand 662420-B User Manual

OPERATOR’S MANUAL 662420-B
INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING.
INCLUDE MANUALS: 6544X-X Air Motor (pn 97999-64) & S-632 General Information Manual (pn 97999-624).
RELEASED: 6-30-70 REVISED: 3-12-09 (REV. N)
4-1/4” AIR MOTOR 9:1 RATIO 4” STROKE
662420-B
Basic Oil Pump
READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
The original language of this manual is English.

PUMP DATAPUMP DATASERVICE KITS

Use only genuine ARO® replacement parts to assure compat-
ible pressure rating and longest service life. 61053 for repair of air motor and lower pump end.
61268 for repair of 65441-B air motor.
65823 packing kit assembly.

SPECIFICATIONS

Model Series
Pump Type . . . . . . . . . . . . . . . . . . . . . . . . . Air Operated, Two-Ball Pump
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:1
Air Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65441-B
Motor Repair Kit . . . . . . . . . . . . . . . . . . . . . . . 61268
Motor Diameter . . . . . . . . . . . . . . . . . . . . . . . 4-1/4” (10.8 cm)
Stroke (double acting) . . . . . . . . . . . . . . . . . 4” (10.2 cm)
Air Inlet (female) . . . . . . . . . . . . . . . . . . . . . . . 1/2 - 14 NPTF - 1
Air Exhaust (female). . . . . . . . . . . . . . . . . . . . 1-1/4 - 11-1/2 NPTF - 1
Material Outlet (female) . . . . . . . . . . . . . . . 3/4 - 14 NPTF
Lower Pump End . . . . . . . . . . . . . . . . . . . . . . . . . 60873
Material Inlet (female) . . . . . . . . . . . . . . . . . 2 - 11-1/2 NPT
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . see  gure 1
(refer to option chart)
. . . . . . . . . . . 662420-B
“A”
“B”
MODELS 662420-B
Air Exhaust (female)
1-1/4 - 11-1/2 NPTF - 1
Air Inlet (female)
1/2 - 14 NPTF - 1
65441-B Air Motor
(see manual 6544X-X)
Material Outlet (female)
3/4 - 14 NPTF
PUMP PERFORMANCE
Air Inlet Pressure Range . . . . . . . . . . . 0 - 150 p.s.i.g. (0 - 10.3 bar)
Fluid Pressure Range . . . . . . . . . . . . . . 0 - 1350 p.s.i.g. (0 - 93.1 bar)
Maximum Rec'd Cycles / Minute . . . . . . . . . 75
Displacement In. Per Cycle . . . . . . . . . . . . . . 12.0
Volume / Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.65 oz. (196.8 ml)
Cycles Per Gallon . . . . . . . . . . . . . . . . . . . . . . . . 19.2
Maximum Working Flow Rate . . . . . . . . . . . . 3.9 g.p.m. (14.8 l.p.m.)
Noise Level @ 60 p.s.i. - 40 c.p.m.
Tested with 91790 silencer installed.
The pump sound pressure level has been updated to an Equivalent Continuous
Sound Level (LAeq) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.
. . . . . . 81.8 db(A)

GENERAL DESCRIPTION

The 9:1 ratio is an expression of the relationship between the e ec­tive air motor area and the e ective lower pump area. When 150 p.s.i. (10.3 bar) of air pressure is supplied to the air motor, the lower pump end will develop a maximum 1350 p.s.i. (93.1 bar) of fluid pressure (at no  ow). As the  uid control is opened, the  ow rate will increase as the air motor cycle rate increases to keep up with demand.
INGERSOLL RAND COMPANY LTD
P.O. BOX 151  ONE ARO CENTER  BRYAN, OHIO 43506-0151
(800) 276-4658  FAX (800) 266-7016
 uids.ingersollrand.com
Figure 1
Material Inlet (female)
2 - 11-1/2 NPT
NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only.
Model “A”
662420-B 29”
(mm)
“B”
(736.4)
15-1/8"
(mm)
(383.9)
IMPORTANT
This is one of three documents which support the pump. Re­placement copies of these forms are available upon request.
662420-B Model Operator’s Manual (pn 97999-108)
S-632 General Information - Air / Hydraulic Operated Piston
Pumps (pn 97999-624)
6544X-X Air Motor Operator’s Manual (pn 97999-64)

PARTS LIST

Item Description
1 Air Motor (1) 65441-B
 
2 Spacer (1) 96624 [Br]
 
3 Seal (1) 96625 [U]
 
5 Spring (1) 90120 [C]
 
6 Washer (1) 90125 [Co]
 
7 “O” Ring
8 Nut
9 Piston Rod (1) 76507 [C] 10 Cup Follower (1) 75678 [C] 11 Ball
 
12 Cup (1) 92867-1 [UH]
 
13 Washer (1) 75682 [C]
14 Inner Check Seat (1) 75681 [C]
(size)
(1/16” x 2-1/8” o.d.)
(1/2” - 20)
(1.0000” diameter)
Qty Part No. Mtl
(1) Y325-33 [B] (2) Y11-108-C [C]
(1) Y16-232 [C]

OPERATING AND SAFETY PRECAUTIONS

WARNING
mum operating pressure of 1350 p.s.i. (93.1 bar) at 150 p.s.i. (10.3 bar) inlet air pressure.
Pump Ratio X = Maximum Pump Inlet Pressure to Pump Motor Fluid Pressure
Pump ratio is an expression of the relationship between the pump motor area and the lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied to the motor of a 4:1 ratio pump, it will develop a maximum of 600 p.s.i. (41.4 bar)  uid pressure (at no  ow) - as the  uid control is opened, the  ow rate will increase as the motor cycle rate increases to keep up with the demand.
WARNING
safety precautions and important information.
The two-ball pumps are primarily designed for the pumping of
medium viscosity fluids. The two-ball design provides better priming of the lower foot valve. The double acting feature is standard in all ARO industrial pumps. Material is delivered to
the pump discharge outlet on both the up and down stroke. NOTICE: Thermal expansion can occur when the  uid in the mate­rial lines is exposed to elevated temperatures. Example: Material lines located in a non-insulated roof area can warm due to sunlight. Install a pressure relief valve in the pumping system.
Replacement warning label (pn 92325) is available upon re­quest.
HAZARDOUS PRESSURE. Do not exceed maxi-
Refer to general information sheet for additional

LOWER PUMP END DISASSEMBLY

NOTE: All threads are right hand.
While holding pump securely with a strap wrench, unthread
1.
and remove (15) tube.
Loosen (8) nut against motor rod and unthread (9) piston rod
2.
from motor rod.
Unthread and remove (14) inner check seat, releasing (13)
3.
washer, (12) cup and (11) ball.
Loosen (8) nut to unthread and remove (10) cup follower from
4.
(9) piston rod.
While holding (15) tube securely, unthread and remove (19)
5.
foot valve seat and components.
Remove (16) ball stop pin, releasing (18) ball.
6.

LOWER PUMP END ASSEMBLY

NOTE: Thoroughly clean and lubricate all seals. Replace all soft parts with new ones included in the repair kit. Note: Refer to the
illustration ( gure 2, page 3) for packing lip direction.
Assemble (17) “O” ring, (18) ball and (16) ball stop pin to (19)
1.
Item Description
15 Tube (1) 76506 [C] 16 Ball Stop Pin
 
17 “O” Ring
18 Ball 19 Foot Valve Seat (1) 77006 [C] 20 Reducer
Lower Pump Assembly
7 - 20)
Items included in repair kit (1) 61053
Items included in packing kit (1) 65823
(size)
(3/16” o.d. x 1-13/16”)
(1/8” x 1-7/8” o.d.)
(1.2500” diameter)
(1-1/2 11-1/2 NPT x 2 - 11-1/2 NPT)
(includes items
Qty Part No. Mtl
(1) 83009 [C] (1) Y325-223 [B] (1) Y16-240 [C]
(1) Y202-12 [I]
(1) 60873
foot valve seat. Assemble (19) foot valve seat and components to (15) tube.
2. NOTE: Tighten (19) foot valve seat to 125 - 150 ft lbs (169.5 -
203.4 Nm). Assemble (9) piston rod and (8) nut to (10) cup follower. NOTE:
3. Apply Loctite 242 to threads of (9) piston rod before assembly. NOTE: Tighten (8) nut to 50 - 60 ft lbs (67.8 - 81.3 Nm). Assemble (12) cup, (13) washer and (11) ball to (10) cup fol-
4. lower, securing with (14) inner check seat. NOTE: Tighten (14) inner check seat to 65 - 70 ft lbs (88.1 - 94.9 Nm). Assemble (3) seal, (2) spacer, (5) spring and (6) washer into cav-
5. ity in bottom of motor. NOTE: Refer to  gure 2, page 3 for pack­ing lip direction. Assemble (8) nut and (9) piston rod and components to motor
6. rod, tightening (8) nut against motor rod. NOTE: Apply Loctite 242 to threads of (9) piston rod before assembly. NOTE: Tighten (8) nut to 60 - 70 ft lbs (81.3 - 94.9 Nm). Assemble (7) “O” ring to (15) tube and assemble (15) tube over
7. (10) cup follower and components and into air motor base. NOTE: Tighten (15) tube to 90 - 100 ft lbs (122.0 - 135.6 Nm).

TROUBLE SHOOTING

Pump problems can occur in either the air motor section or the lower pump end section. Use these basic guidelines to help deter­mine which section is a ected.
Pump will not cycle.
Be certain to first check for non-pump problems including
kinked, restrictive or plugged inlet / outlet hose or dispensing device. Depressurize the pump system and clean out any ob­structions in the inlet / outlet material lines. Refer to the motor manual for trouble shooting if the pump
does not cycle and / or air leaks from the air motor. Inadequate air supply. Increase air pressure to the pump.
Obstructed material line. Remove obstruction.
Damaged motor. Service the motor.
Material on one stroke only (fast downstroke).
Ball (18) is not seating. Remove the ball from the foot valve,
clean and inspect the ball and foot valve seat area. If the ball or foot valve is damaged, replace.
Material on one stroke only (fast upstroke).
Cup (12) is worn. Replace.
Loctite® and 242® are registered trademarks of Henkel Loctite Corporation
ARO® is a registered trademark of Ingersoll-Rand
Page 2 of 4 662420-B (en)