Indesit CA55KUK, CA55UK, CAA55UK, CA55SUK, CAA55KUK Service Information

...
Indesit Company UK Ltd
© 2011 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Service Information
INDESIT
FREESTANDING
FRIDGE
Models Comm. Covered Code
CA55UK 69937 CA55KUK 74471 CA55SUK 75733
Energy Band A+ Models CAA55UK 77736 CAA55KUK 77739 CAA55SUK 77740 NCAA55UK 77735
5407586 Issue 3 May 2012
2 of 13
Service Manual UK
Indesit
Company
English
HEALTH AND SAFETY
For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published.
Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
1. Only engineers who have been trained on the safe handling of Isobutane R600a refrigerant are authorised to transport, store or carry out system repairs.
2. This manual is not intended as a comprehensive repair/maintenance guide to the appliance.
3. Must only be used by suitably qualified persons having technical competence, applicable product knowledge, suitable tools and test equipment.
4. Servicing of electrical appliances must be undertaken with the appliance disconnected (unplugged from the electrical supply).
5. Servicing must be preceded by earth continuity and insulation checks, plus refrigerant leak detection.
6. Personal safety precautions must be taken to protect against accidents caused by sharp edges on metal and plastic parts.
7. After servicing, the appliance must be rechecked for electrical safety.
8. Smoking, naked flames, or operating gas and/or electrical equipment (including cordless power tools) are forbidden within the storage area, working area and vehicles used to transport Isobutane.
9. The carrying case for the scales and refrigerant must display a red flammability label Part Number 8100063 that should be visible and readable at all times.
10. The vehicle and storage area must be ventilated as far as is reasonably practicable and the aluminium case kept out of direct sunlight. The storage temperature of Isobutane should not exceed 50°C.
11. The vehicle transporting Isobutane (R600a) refrigerant must display a Red Flammable Gas warning sticker (Part No. C00247960 [(8100063)].
12. Engineers should not wear clothes that are liable to cause static discharge ('electrostatic sparking').
13. Avoid working in small rooms.
14. Do not work in cellars.
15. Whenever possible move the appliance into a larger open area away from possible ignition sources.
16. Request the customer to turn off all other electrical and gas appliances in the near vicinity of the repair and note that it is done. Customers should be advised to restrict activity within the near vicinity for a short time.
17. Isobutane refrigerant must be vented to atmosphere, (outside of the premises e.g. via open window through the clear plastic hose supplied).
18. Isobutane is heavier than air and must not be vented within 3 metres of the following: sewer cover, cellar, drain or any similar construction lower than ground level, boiler air inlet/outlet, or near any possible source of ignition.
continued...
3 of 13
Service Manual UK
Indesit
Company
English
HEALTH AND SAFETY
19. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system.
20. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a).
21. All equipment used for this activity must be checked regularly and maintained in a safe working condition; parts must be replaced as required.
Information Regarding Isobutane Canisters
1. The maximum quantity of Isobutane an engineer should hold or store at any one time is two 1kg net aluminium canisters, supplied individually as Part No. C00218421 (2602600).
2. Canisters must be stored inside the aluminium case with the weighing scales for protection from possible damage and heat. The aluminium case must NEVER be placed next to a heat source or in direct sunlight.
3. Isobutane must only be dispensed to the appliance from the 1kg net aluminium canister placed in an upright position on the weighing scales provided.
4. All used canisters must be a returned as scrap and therefore, left out for the driver to collect and return for disposal.
5. Canisters must not be punctured or the internal valve damaged.
6. Before storing the canister it must have the extraction tap valve removed and the internal valve of the canister checked for leakage using leak detector (Leak Detector: Part No. C00222861 (5700043).
7. All used canisters and those found to be leaking should be exhausted to atmosphere to ensure they are emptied completely. Refer to the following paragraph.
8. Refit the extraction tap if necessary, open the tap and then invert the canister. This must be done outside in open air away from buildings and ignition sources and complying with Item 18 on previous page.
SAFETY PRECAUTION - Console Panel Removal
Be aware that removal of the Console Panel / Facia above the fridge door will also release the hinge pivot securing the door.
All food, drink and furniture must be removed from the door before proceeding.
4 of 13
Service Manual UK
Indesit
Company
English
INDEX
Health and Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 3
Index & Serial Number / Industrial Code Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 7
Detailed View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Component Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Servicing & Dismantling Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Door Reversal Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Door Seal Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Theoretical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
SERIAL NUMBER / INDUSTRIAL CODE FORMAT
Mod. - - - - - -
TI
Cod.
93139180000 S/N 704211801
220 - 240 V- 50 Hz 150 W
W
Fuse
A
Max 15 w
Total
Gross Bruto Brut
Compr.
Kompr.
Syst.
R 134 a
kg 0,090
Gross Bruto Brut
340
Net Util Utile
Gross Bruto Brut
Freez. Capac
Poder de Cong
75
Made in - - - - 13918
Test
P.S-I.
Pressure HIGH-235
LOW 140
kg/24 h
4,0
Class
Clase
N
Classe
1
2
Example
1 Industrial Code:
93 13918 0000
0000 original production
Commercial Code*
Factory of origin
2 Serial Number:
704 1801
Build number that day, e.g. 1801th built
Day of manufacture, e.g. 21
st
of month
Month of manufacture, e.g. April
21
Year of manufacture, e.g. 2007
*Vital for correct model information and system identification
Other numbers denote major production changes