IKA RO 10, RO 15, RO 5, RT 5, RT 10 User Manual

...
Page 1
20000004954
RO/RT_072017
IKA® RT 5/10/15
IKA® RO 5/10/15
Page 2
Contents
Page
Control panel and display 02 Contents 09 Declaration of conformity 09 Warranty 09 Explication of warning symbols 09 Safety instructions 10 Unpacking 11 Correct use 11 Commissioning 11 Safe temperature limit 11
Setting the safe temperature limit 11 Stirring function 11 Eco mode 12 Operating modes 12 Direction of rotation reversal 12 Function heating 12 Maintenance and cleaning 12 Error codes (RT 5/10/15) 13 Accessories 13 Technical data 14
EN
Declaration of conformity
Warranty
In accordance with IKA® warranty conditions, the warranty period is 24 months. For claims under the warranty please contact your local dealer. You may also send the machine direct to our factory, enclosing the delivery invoice and giving reasons for the claim. You will be liable for freight costs. The warranty does not cover worn out parts, nor does it apply to faults resulting from improper use, insucient care or maintenance not carried out in accordance with the instructions in this operating manual.
Explication of warning symbols
General hazard.
DANGER
WARNING
CAUTION
This symbol identifies informaton that is of absolute importance to ensure health and safety. Failure to observe this information may be detrimental to health or may result in injuries.
This symbol indicates information witch is important for ensuring that the appliance functions without any technical problems. Failure to observe this information could damage the appliance.
This symbol indicates information which is important for proper use of the appliance and / or
ensuring that the appliance functions correctly.
Failure to observe this information can lead to inaccurate results.
ATTENTION
DANGER
ATTENTION - Risk of damage due to magnetism.
DANGER - Reference to the endangerment by a hot surface
9
Page 3
Safety instructions
For your protection
Read the operating instructions in full before starting
up and follow the safety instructions.
• Keep the operating instructions in a place where they can be accessed by everyone.
• Ensure that only trained staff work with the appliance.
• Follow the safety instructions, guidlines, occupational health and safety and and accident prevention regulations.
• Socket must be earthed (protective ground contact). Attention - Magnetism!
ATTENTION
Effects of the magneticfield have to be into account (e.g. data storage media, cardiac pacemakers ...). RT
DANGER
Risk of burns! Exercise caution when touching the
housing parts and the heating plate. The heating plate can reach temperatures in excess of 125 °C. Pay attention to the residual heat after switching off. RT
WARNING
Ensure that the mains power supply cable does not touch the heating base plate.
• Wear your personal protective equipment in accordance with the hazard category of the media to be processed. Otherwise there is a risk from:
- splashing and evaporati on of liquids
- ejection of parts
- release of toxic or combustable gases.
• Set up the appliance in a spacious area on an even, stable, clean, non-slip, dry and fireproof surface.
• The feet of the appliance must be clean and undamaged.
• Check the appliance and accessories beforehand for damage each time you use them. Do not use damaged components.
• Gradually increase the speed.
• Reduce the speed if
- the medium splashes out of the vessel because the speed is too high
- the appliance is not running smoothly
- the container moves on the base plate.
RT
WARNING
Caution! Only process and heat up any media that has a flash point higher than 180 °C. The safe temperatue limit must always be set to at least 25 °C lower than the fire point of the media used. Beware of hazards due to:
WARNING
- flammable materials
- combustibles media with a low boiling temperature
- glass breakage
- inkorrect container size
- overfilling of media
- unsafe condition of container.
• The appliance may heat up when in use.
• The base plate can heat up due to the action of the drive mag­ nets at high motor speeds, even if the heater is not operational.
• Process pathogenic materials only in closed vessels under a suitable extractor hood. Please contact IKA questions. Do not operate the appliance in explo-
DANGER
sive atmospheres, with hazardous substances or under water. Only process media that will not react
DANGER
dangerously to the extra energy produ­ ced through processing. This also ap­ plies to any extra energy produced in other ways, e.g. through light irridiation.
• Please observe the operating instructions for any accessories used.
• Safe operation is only guaranteed with the accessories descri­ bed in the „Accessories“ chapter.
• Accessories must be securely attached to the device and cannot com off by themselves. The centre of gravity of the assembly must lie within the surface on which it is set up.
• Always disconnect the plug before fitting accessories.
• The appliance can only be disconnected from the mains supply by pulling out the mains plug or the connector plug.
• The socket for the mains cord must be easily accessible.
• It may be possible for wear debris from rotating accessory parts to reach the material being processed.
• When using PTFE-coated magnetic bars, the following has to be noted: Chemical reactions of PTFE occur in contact with molten or
solute alkali metals and alkaline earth metals, as well as with fine powders of metals in groups 2 and 3 of the periodic sys­ tem at temperatures above 300 °C - 400 °C. Only elementary fluorine, chlorotrifluoride and alkalimetals attack it; halogena­ ted hydrocarbons have a reversible swelling effect.
For protection of the equipment
• The appliance may only be opened by experts.
• The voltage stated on the type plate must correspond to the mains voltage.
• Do not cover the device, even partially e.g. with metallic plates or film. This results in overheating.
• Protect the appliance and accessories from bumps and impacts.
• Ensure that the base plate is kept clean.
• Observe the minimum distances between the devices, between device and wall and minimum distances (min. 800 mm) above the assembly, see Fig. 2.
(Source: Römpps Chemie-Lexikon and „Ullmann“ Volume 19)
>100 mm
>100 mm
>100 mm
®
if you have any
Fig. 2
10
Page 4
Unpacking
•Unpacking
- Please unpack the device carefully
- In the case of any damage a detailed report must be sent immediately (post, rail or forwarder)
Correct use
• Use
- For mixing and / or haeting liquids
• Range of use (inside only)
- Laboratories - Schools
- Pharmacies - Universities
The device is suitable for use in all areas except:
Commissioning
RO/RT
Observe the ambient conditions (temperature, humidity, etc.) listed under Technical Data.
The device is switched on and off via the switch (A) located on the right-hand side of the device. On the front panel a small arrow labelled Power above the display (B) indicates the location of the switch.
• Delivery scope
RO RT
- Magnetic stirrer - Heating magnetic­ RO 5/10 or 15 stirrer RT 5/10 or 15
- power supply unit - mains cable
- operating instruction - operating instruction
- Residential areas
- Areas that are connected directly to a low-voltage supply net­ work that also supplies residential areas.
The safety of the user cannot be guaranteed if the appliance is operated with accessories that are not supplied or recommended by the manufacturer or if the appliance is opreated improperly contrary to the manufacturer‘s specifications or if the appliance or the printed circuit board are modified parties.
After the device is switched on a display self-test is performed. The display cycles through the following information:
• All segments light up
• The software version and the selected mode are displayed
• The selected “Eco Mode” is displayed (E when ECO mode is active)
• If the drive has not been started the display reads „OFF“. If the drive has been started the selected speed is displayed.
Safe temperature limit
RT
The max. attainable heating plate temperature is restricted to 130 °C by a permanently set safety temperature limit. Once this limit has been attained, the device switches off the heating.
Setting the safe temperature limit
RT
The safety temperature is set as follows: Switch the device on using the On/Off switch on the right side of the device. As soon as the display shows SAFE, press and hold down the Temp membrane key and use
Stirring function
RO/RT
The stirring function is started and stopped by pressing the „Start/ Stop“ button (C). Pressing the +/- buttons (E or D) increases or reduces the speed.
The safe temperature limit must all-
WARNING
ways be set at least 25 °C lower than the fire point of the media to be processed!
the +/- membrane keys (H or I) to set the desired safety temperature.
The set safety temperature is displayed.
Once the Temp membrane key is released, the safety temperature is saved.
11
Page 5
ECO mode
RO/RT
The heat generated in the device can be reduced by lowering the power of the input coils. Pressing the “ECO Mode“ (F) key to reduce the current power setting. ECO mode is indicated by an “E” preceding the speed. When the power is set to ECO mode, the speed is limited to 600 rpm.
Operating modes
RO/RT
To toggle between modes, press the Start/Stop key (C) when switching on.
Operating Mode “A” All the parameter settings are retained when the device is switched off or disconnected from the mains. The “Start/Stop” (C) key starts the device with the set parameters.
Operating Mode “B“ All parameter settings, including “Start/Stop”, are saved when the device is switched off.
Direction of rotation reversal
To make the stirring power more independent from the speed range, press the “ECO Mode“ membrane key (F) and then select one of the following setting options.
P50 (Stirring power 50% independent of the speed range) P75 (Stirring power 75% independent of the speed range) P100 (Stirring power 100% independent of the speed range)
---- (Standard stirring performance with the stirring power regulated by the speed)
Operating Mode “D“ In the D mode the device operates as per the A mode but with the following exception:
- Switch on and then press the “Temp” membrane key to confirm the safety temperature.
- The value flashes until it is confirmed.
Factory setting: mode A
RO/RT
The (G) key activates the “Reverse Rotation” function. When the „Reverse Rotation“ function is switched on, a decimal point (K) appears in the LCD display.
The running time (30, 60, 90 or 120sec) is set by pressing the (G) key followed by the +/- keys.
After the preset running time, the drive is switched off and restarted at minimum speed in the opposite direction after a pause specific to the speed.
Function Heating
RT
The heating function is started and stopped by pressing the „Temp“ button (J).
Maintenance and cleaning
The equipment is maintenance-free. It is only subject to the natu­ral wear and tear of components and their statistical failure rate.
Cleaning
For cleaning disconnect the main plug..
Use only cleansing agents which have been approved by IKA clean devices.
®
to
In this way the magnetic rod is captured and any liquid still rotating is gradually slowed down. Then the drive accelerates to the target speed.
Note: If the “Reverse Rotation” key (G) is pressed again, the drive will keep rotating in the same direction.
When the device is started up again, the drive will rotate in the direction last set.
Pressing the +/- buttons (H or I) increases or reduces the temperature.
Use to remove:
Dyes Isopropyl alcohol Construction materials water containing ten side / isopropyl alcohol Cosmetics water containing ten side / isopropyl alcohol Foodstuffs water containing tenside Fuels water containing tenside
- Do not allow moisture to get into the appliance when cleaning.
- Wear protective gloves when cleaning the devices.
- Please consult with IKA
®
before using any cleaning or deconta
mination methods, other than those recommended here.
12
Page 6
Ordering spare parts
When ordering spare parts, please give:
- Device type
- Manufacturing number, see type plate
- Software version
- Item number and designation of the spare part, see www.ika.com.
Repair
Please send instrument in for repair only after it has been cleaned and is free from any materials which may consti­tute a health hazard. For this you should request the “Decontamination Clearance Certificate” from IKA
®
the IKA Return the instrument in its original packaging. Storage packaging is not sucient. Also, please use suitable shipping package mate­rials.
website www.ika.com.
®
, or use the download printout of it from
Error Codes (RT 5/10/15)
Error- Cause Effect Solution code
Er 3 Temperature inside device too high Heating off - Switch off device and allow to cool down Er 6 Break in safety circuit Heating off - Plug in contact plug
- Plug in contact thermometer or PT 1000 temperature sensor
- Replace faulty connection cable, plug, or contact thermometer Er21 Safety relay doesn‘t open during test Heating off - Switch off device
- Warning! Only to be carried out by authorised service personnel: Check PCB Er22 Safety temperature is too low during test Heating off - Switch off device
- Warning! Only to be carried out by authorised service personnel: Check PCB and safety temperature sensor Er25 Heating and switching element monitoring Heating off - Check the external temperature controller
- Switch off device
- Warning! Only to be carried out by authorised service personnel:
Carry out an internal test on the device to check the plug-in connector for the heating element, the safety temperature sensor or the PCB
Er26 Difference between temperature of safety Heating off - Switch off device sensor and temperature of control sensor - Warning! Only to be carried out by authorised service personnel:
control temperature > (safety tempe- Carry out an internal test on the device to check the plug-in connector rature + 40 K) for the temperature sensor
Er31 Triac error detection doesn‘t work Heating off - Switch off device
- Warning! Only to be carried out by authorised service personnel: Check PCB Er46 Difference between temperature of safety Heating off - Switch off device sensor and temperature of control sensor - Warning! Only to be carried out by authorised service personnel: control temperature > (control tempe- Carry out an internal test on the device to check the plug-in connector rature + 40 K) for the temperature sensor
If the actions described fail to resolve the fault or another error code is displayed then take one of the following steps:
- Please contact the service department; Send the device for repair, including a short description of the fault.
-
Accessories
• Stirring bar: ø 8 mm; lenght 30 mm
RSE Stirring bar remover
13
Page 7
Technical data
RO
Power supply unit Input V 100 - 240
A 1,67
Output Vdc 24; 40 W.LPS; (limited power source)
Hz 50/60
Protection class 2 (double insulated)
Operating voltage Vdc 24
RO 5 RO 10 RO 15
A 0,5
ower consumption (max.) W 12 24 36
P Power consumption, standby operation W 2 Power output W 17 Speed r
anges P50, P70, P100, ---- rpm
O-Mode rpm 0 - 600 in 10 rpm-steps adjustable
EC
Set-up surface mm 120 x 450 180 x 450 270 x 450 Dimension: mm 120 x 570 x 60 190 x 570 x 60 280 x 570 x 60 Weight: kg 3,0 4,0 7,0
RT
Unit Oper
ating voltage Vac 230 ± 10%
Frequency Hz 50 / 60
anges P50, P70, P100, ---- rpm
Speed r
EC
O-Mode rpm 0 - 600 in 10 rpm-steps adjustable
Power consumption (max.) W 185 395 600 Set-up surface mm 110 x 495 180 x 495 270 x 495 Dimension: mm 120 x 610 x 60 190 x 610 x 60 280 x 610 x 60 Weight: kg 4,0 6,5 9,4
Adjustment and display resolution K 1 Surface temperature °C 120*
0 - 1200 in 10 rpm-steps adjustable
RO 5 RO 10 RO 15
Vac 115 ± 10%
0 - 1000 in 10 rpm-steps adjustable
RT 5 RT 10 RT 15
1,0 1,5
Safety temperature limit (adjustable) °C 50 - 150
RO/RT 5 RO/RT 10 RO/RT 15
use: 230 V A
F
100 V / 115 V
RO/RT
Setting resolution rpm ±5 Deviation between the stirrer points % 0 Permissible duration of operation % 100 Permissible ambient temperature °C +5 to +40 Permissible relative humidity % 80 EN 60529 protection class IP 40 Operation at a terrestrial altitude m max. 2000
Stirred quantity max. (water) 400 ml per stirrer point in the 600 ml beaker glass
in other vessels ltr 2 4 6 Stirrer points 5 10 15 Distance from stirrer point to stirrer point mm 90 90 x 90 90 x 90
*Caution! The specified maximum hotplate temperature r
ithout a load, the (setup) plate temperature can reach 130 °C (+10 °C / -5 °C).
W Load to determine the specified values: 250 ml Erlenmeyer flask filled with 200 ml water.
T 2 (5x20) T 4 (5x20) T 6,3 (5x20)
A T 4 (5x20) T 6,3 (5x20) T 10 (5x20)
RO/RT 5 RO/RT 10 RO/RT 15
efers to instruments with a full load.
14