IKA MICROSTAR control, MICROSTAR 30 control, MICROSTAR 15 control, MICROSTAR 7.5 control User Manual

MICROSTAR control
Device setup
/// MICROSTAR control
7
6
1
2
5
4
3
/// What you should watch out for
1 Operator panel and display
2 Chuck
4 Temperature sensor socket
5 Power socket
6 USB interface
7 Stirring shaft cap
Attention! ( )
Device setup 98 Device setup
Safety instructions
/// Explication of warning symbols
/// General information
Read the operating instructions in full before
starting up and follow the safety instructions.
› Keep the operating instructions in a place where it
can be accessed by everyone. › Ensure that only trained staff work with the device. › Follow the safety instructions, guidelines, occupational
health and safety and accident prevention regulations.
Indicates an (extremly) hazardous situation, which, if not avoided, will result in death, serious injury.
Indicates a hazardous situation, which, if not avoded,
can result in death, serious injury.
Indicates a potentially hazardous situation, which, if not avoided, can result in injury.
Indicates practices which, if not avoided,
!
can result in equipment damage.
Danger! (
Please pay attention to the dangerous parts of the equipment in device setup. Beware of the risk of:
› flammable materials › glass breakage as a result of mechanical stirring power
Caution! (
Wear your personal protective equipment in accordance with the hazard category of the medium to be processed, there is a risk of:
› splashing of liquids › projectile parts › body parts, hair, clothing and jewelry getting caught
The device must only be used in a technically perfect condition.
)
)
Safety instructions 1110 Safety instructions
/// Device setup
/// Working with the device
Danger! ( )
Users must make sure that the OFF switch of the IKA device can be accessed immediately, directly and without risk at any time. If installation or positioning cannot ensure this access at all times, an additional EMERGENCY STOP switch that can be easily accessed must be installed in the work area.
Warning! (
Ensure stable assembly. The vessel used for stirring must be secured. Use stirring shaft protective equipment!
› Set up the stand in a spacious area on an even, stable,
clean, non-slip, dry and fireproof surface.
› Remove the chuck key from the chuck before turning
on the device.
› Place the power supply outside the working area of the device. › Avoid knocking and impacting on the lower end of the shaft and
the chuck gear teeth. Even minor, invisible damage can lead to
imbalance and uneven shaft action. › All screw connections must be properly tightened. › The high torque developed by the device requires particular care
in the choice of stand, cross sleeve and anti-rotation element for
the agitating vessel.
)
Danger! ( )
Do not operate the device in explosive atmospheres, with hazardous substances or under water. The device is not explosion – proof it does not meet any Class / Division or Zone explosion protection standards.
› The device is not suitable for hand-held operation. › Do not touch rotating parts during operation!
Warning! (
Pathogenic materials must only be processed in closed vessels under a suitable fume hood. If you have any questions, please contact IKA application support.
The operation of a free rotating shaft end is prohibited. Therefore, for safety reason, only insert through the stirring tool over the upper edge of housing at standstill.
Caution! (
Make certain that the unit is set at the lowest speed before commissioning; otherwise, the unit will begin running at the speed set in last operation. Gradually increase the speed. Please observe the max. permitted speed for the stirring element. Never set higher speed.
Covers or parts that can be removed from the device without tools must later be refitted to ensure safe operation. This will prevent the infiltration of foreign objects, liquids and other contaminants.
)
)
Safety instructions 1312 Safety instructions
/// Accessories
› Imbalance of the output shaft, the chuck and in particular the stirring
tools can lead to uncontrolled resonant vibrational behavior of the device
and the whole assembly. Glass apparatus and stirrer containers can be
damaged or shattered by this. It can cause injury to the operator, also can
damage the rotating stirring tool. In this case exchange the stirring tool
for one without imbalance or remedy the cause of the imbalance. If there
is still imbalance, return it to the dealer or the manufacturer along with a
description of the fault.
› There may be electrostatic activity between the medium and the output
shaft which could cause a direct danger.
› Never operate the device with the stirrer tools rotating freely. Ensure that
parts of the body, hair, jewelry or items of clothing cannot be trapped by
the rotating parts.
› Pay attention when setting the speed to any imbalance of the stirrer tools
and possible spraying of the medium to be stirred.
› Ensure that the stand does not start to move. › Only process media that will not react dangerously to the extra energy
produced through processing. This also applies to any extra energy
produced in other ways, e.g. through light irradiation.
Reduce the speed if:
› the medium splashes out of the vessel because the speed is too high, › the device is not running smoothly, › the device begins to move around because of dynamic forces, › an error occurs.
› Protect the device and accessories from bumping and impacting. › Check the device and accessories beforehand for damage each time
when you use them. Do not use damaged components.
› Safe operation is only guaranteed with the accessories described
in the ”Accessories” section.
› Must disconnect the power before changing stirring element and
fitting allowed accessories.
/// Switch on / off the device
If the device is operated too long in overload or if the ambient teperature is too high, the device switches off permanently.
› Disconnecting the device from the power outlet only works by removing
the main cord from the socket. › The device must only be operated with the original power supply unit. › The power supply comes with interchangeable plug adapters for different
countries so make sure the appropriate adapter is used. › The outlet for the power supply must be easily accessible. › After an interruption in the power supply during a stirring process,
the device does not restart automatically. › The device must only be opened by trained technicians, even during repair.
The device must be unplugged from the power supply before opening. Live
parts inside the device may still be live for some time after
unplugging from the power supply.
/// Disposal
The device must be disposed of in accordance with national regulations.
Safety instructions 1514 Safety instructions
Correct use
/// Basics
Unpacking
/// Scope of Delivery
Use
› For mixing / stirring liquids from low to medium viscosities
with various stirring tools.
› Stand device (chuck points down)
Range of use (indoor use only)
› Laboratories › Pharmacies › Universities › Schools
The safety of the user cannot be guaranteed:
› if the device is operated with accessories that are not supplied or
recommended by the manufacturer.
› if the device is operated improperly or contrary to
the manufacture’s specifications.
› if the device or the printed circuit board are modified by third parties.
Unpack the device carefully. Any damage should be notified immediately to
the shipping agent (post oce, railway network or logistics company).
Scope of Delivery
› MICROSTAR overhead stirrer › power supply (with exchangeable adapters) › extension arm › hexagonal socket screw › hexagon socket offset screw key › shaft protector R 300 (with 2 fasten screws) › chuck key › USB cable › H 67.60 temperature sensor › user guide › warranty card
++
+
++
MICROSTAR control
Unpacking 1716 Correct use
+
+
+
Warranty