THE SETTING SCREEN OF THE UC-FR5000
*This illustration
is described with the UT-105.
NOTE: Internet Explorer 6.0 or later is required to correctly open the setting screen of the controller. The following instructions are based on using Internet Explorer
7.0. JavaScript must be installed to open the side menu and help window of the Setting screen.
D Accessing the setting screen
NOTE: You must wait to launch the web browser until the
controller system software startup is completed.It typically takes 2 ~ 3 minutes for the controller to startup the application.
1. Connect a CAT-5 straight cable between the
controller’s [LAN] connector and a PC (p. 3) and then
turn ON the repeater.
2. Before accessing the Setting screen, change the IP
address of the PC to 192.168.0.XXX* (A subnet mask
should be 255.255.255.0) in the Control Panel.
*
Replace XX X with any number between 1 and 254 (except 11).
L Refer to the Operating System’s manual for details.
3.
Open your web browser, enter “http:// 192.168.0.11/”
(default IP address of the UC-FR5000) into the address
bar, and then push [Enter].
The Login Authentication screen is displayed.
L Ask your system administrator for details.
Enter
4.
Enter “cbadmin” (default user name) and “ucfr5000” (default password) in their respective input field in the
Login Authentication screen, and then click <OK>.
If you want the screen to remember not only the
user name but also the password, check the box, “Remember my password”.
The Opening screen is displayed.
Enter
Check
Click
D Opening the help window
The Setting screen of the controller has a help window to describe functions and settings. If you don’t understand the meaning of an item, or how to
congure the controller, click a question mark icon on the
screen to open the help window.
Click to open the help window for “General Settings,” for example.
D Initialization
You can reset all set contents, including the network settings of the controller, to the factory default from the PC.
1. Connect the controller to the PC, and then turn ON the repeater.
2. Open your web browser, enter the initialize address into
the address bar, and then push [Enter].
• The initialize screen is displayed.
L Initialize address: http://(IP address):8080/init.html L When the IP address of the controller is 192.168.0.11*, enter
“http://192.168.0.11:8080/init.html” as the initialize address.
* The IP address is an example only. Check the IP address
of the controller.
Enter
3. After checking the box “Yes, I agree,” click <RESET> to initialize the settings.
TIP: If you use the UC-FR5000 #03, you can select whether or not to reset the Network settings as well as other settings. Refer to the help window for details.
INSTRUCTIONS
TRUNKING/NETWORK CONTROLLER
UC-FR5000
PRECAUTIONS
R WARNING! Turn OFF the repeater before installing the
controller. Otherwise a re, electric shock may occur, or the
repeater could malfunction. CAUTION: NEVER expose the repeater or controller to rain, snow or any liquids. CAUTION: NEVER let metal, wire or other objects touch any internal part of the controller.
CAUTION: Install the controller in only the specied repeater. BE CAREFUL! When you install the controller, wear gloves
to avoid cutting your hand on the sharp edges of the repeater.
CONFIGURATIONS
The controller enables the repeater to be used for the
following modes, depending on the congurations. (This
table is shown in controllers whose revision number is 3.5 or later. Ask your dealer for details.)
Single Site Multi Site
Conventional Trunking Conventional Trunking
UC-FR5000#01
*
1
*
UC-FR5000#02
( CF-FR5000MC is
supplied)
*
UC-FR5000#03
( CF-FR5000MT is
supplied)
UC-FR5000#04
*1 When the optional RS-FS10 remote communicator is used, ei-
ther the CF- FR5000MC or CF-FR5000MT is required. *2 Either the optional CF- FR5000MC or CF-FR5000MT is required. *3 The optional CF-FR5000MT is required.
1
*
*
ABOUT THE CF CARD
The supplied or optional CF card must be inserted to enable the Multi Site Conventional or Trunking mode use. Before inserting a CF card to the controller’s card slot, carefully read the card’s instructions.
DISPOSAL
2
2
*
*
3
3
3
Thank you for choosing this Icom product. The controller is designed to be installed into the IC­FR5000/IC-FR6000 series
vhf /uhf fm repeaters and
enables the on-line control and digital trunking operation on the repeater. READ ALL INSTRUCTIONS carefully and completely before using this product.
DISASSEMBLING THE UNITS
1. Unscrew the seven screws from the top, and the two screws on both sides of the repeater, then slide the top cover off in the direction of the arrow.
Top cover
Repeater
2. Disconnect the control cable from the channel module. Then, unscrew the seven screws that affix the channel module to the repeater chassis, and then remove it.
Channel module
Control cable
P
0
P
1
P
2
P
3
P
4
Front panel*
* The front panel is removed in this illustration so the details are
easier to see. However, you can remove the channel module without removing the front panel of the repeater.
3. Unscrew the eight screws from the top, the nine screws from bottom, and the three screws from rear of the channel module. Then remove each cover from it.
Repeater
TIP: You can change the user name and password in the Setting screen. Refer the help window of the Setting screen for details.
Check
L This screen slightly differs, depending on the Operating
System version.
- 4 -
Click
The crossed-out wheeled-bin symbol on your product, literature, or packaging reminds you that in the European Union, all electrical and electronic products, batteries, and accumulators
(rechargeable batteries) must be taken to
designated collection locations at the end of their working life. Do not dispose of these products as unsorted municipal waste. Dispose of them according to the laws in your area.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
Channel module
- 1 -
A-6691H-1EX-u Printed in Japan
© 2008–2016 Icom Inc.
)
Rear panel Rear panel
INSTALLATION
q
w
BUS-1 BUS-2LAN
PC
P
0
P
1
P
2
P
3
P
4
ASSEMBLING THE UNIT CONNECTION
D Installing the UC-FR5000
Install the controller into the channel module using six of the seven supplied 3 × 8 mm screws.
NOTE: BE SURE to match the holes in the controller to the projections on the channel module’s chassis.
Controller
Holes
Projections
Channel module
D Connecting the at cable
NOTE: BE SURE to insert the at cable with the metal
strips facing the edge of the Printed Circuit Board (PCB),
and not the opposite way.
1. Turn the channel module upside down.
Insert one end of the at cable into J8 on the PCB of
the channel module. Then, carefully pass the at cable
through the opening of the channel module’s chassis to the top side.
Bottom
Front
Flat cable
Rear
Top
2. Turn over the channel module.
Carefully pull out the other end of the at cable from the
opening, and then insert it into J1 on the controller.
Top
Front
Rear
Bottom
Flat cable
J8
Opening
J1
D Attaching the rear panel
1. Reattach the top and bottom covers of the channel module, and then tighten all the screws.
1. Attach the supplied rear panel to the rear panel holder using one of the seven supplied 3 × 8 mm screws.
2. Attach the rear panel and holder set to the channel module using the three supplied 3 × 8 mm screws.
Channel module
Rear panel
q
w
Channel module
Rear panel holder
2.
TIP: If you have installed a channel extension module
(optional UR-FR5000/UR-FR6000 series), an additional
controller in it enables you to control each channel
Reinstall the channel module and the screws to their original positions, and then connect the control cable of the repeater’s front panel to the channel module.
module from a PC in the Conventional/Trunking operation mode.
Channel module
SUPPLIED ACCESSORIES
Control cable
holder
Flat cable
Dust protectors
Screws
(
3 × 8 mm
CF card*
)
Screws
(
3 × 12 mm
Connector caps
Repeater
Front panel
3. Reattach the top cover of the repeater, and then tighten the seven screws for the top and the two screws on
*Not supplied, depending on the controller’s version.
both sides of the repeater.
Top cover
OPTION
CF-FR5000MC cf card
Upgrades the UC-FR5000 #01 to enable Multi Site Conventional mode operation. Same as that supplied with UC-FR5000 #02.
CF-FR5000MT
cf card
Upgrades the UC-FR5000 #01 to enable Multi Site Conventional/Trunking mode operation. Same as that supplied with UC-FR5000 #03.
Icom is not responsible for the destruction or damage to the
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom
Incorporated (Japan) in Japan, the United States, the United Kingdom,
Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries. JavaScript is a registered trademark of Sun Microsystems, Inc. All other products or brands are registered trademarks or trademarks of their respective holders.
Icom transceiver, if the malfunction is because of:
• Force majeure, including, but not limited to, res, earthquakes, storms, oods, lightning, other natural disasters, disturbances,
riots, war, or radioactive contamination.
• The use of Icom transceivers with any equipment that is not
manufactured or approved by Icom.
- 2 - - 3 -
P
0
P
1
P
2
P
3
P
4
Repeater
NOTE:
• CAT-5 straight cables are required for connection. (User supplied)
BE SURE to cover each connected cable with a supplied dust protector. Even if the cable has its own cover, replace it with the supplied dust protector.
KEEP the supplied connector caps attached when the connectors are not in use, to avoid getting bad contacts from dust and moisture.
Each controller has a LAN connector and two BUS connectors.
q [LAN] connector
For an Ethernet connection. Connect the controller to an
Ethernet (LAN) port of a PC.
In the Trunking mode, the controller at one end of the
chain must be connected. You can control the controller and all others in the chain from the PC.
w [BUS] connectors (BUS-1, BUS-2)
For data communication between the controllers in the
Trunking mode, either BUS-1 or BUS-2 can be used. They enable the controllers to be “daisy-chained” together, and form a network that allows trunking and other data to pass among them.
L The illustration below describes one example of a connection
for the Trunking mode.
Connector cap
Repeater
Channel extension module
Up to 30 channel modules with controllers can be daisy-chained.
Dust protector