ibm thinkpad 600x Schematics

Symptom-to-FRU error messages
Symptom-to-FRU error messages
This chapter describes the Symptom-to-FRU error messages.
How to use error messages
Use the error codes displayed on the screen to diagnose failures.
If two or more error codes are displayed, begin the diagnosis with the first one. Whatever caused the first error code can cause false error codes to be displayed.
If no error code is displayed, see if the error symptom is listed in the “Symptom-to-FRU index.”
How to diagnose multiple FRUs
When an adapter or a device has more than one FRU, the error code could be caused by any of them. Before replacing multiple FRUs, try removing or exchanging each FRU, one by one in the specified sequence, to see if the symptoms change.
Symptom-to-FRU index
The symptom-to-FRU index lists the symptoms and errors and their possible causes. The most likely cause is listed first.
Note: Do the FRU replacements or other actions in the
sequence shown in the “FRU/Action in Sequence” column. If a FRU replacement does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.
A numeric error code is displayed for each error detected in POST or system operation. In the displays, X can be any number.
If no numeric codes is presented, use the narrative descriptions of symptoms.
If a symptom is not listed, go to “Undetermined problems” on page 31.
Note
For an IBM device not supported by diagnostic codes in the ThinkPad notebook computers, see the manual for that device.
17
Symptom-to-FRU error messages
Numeric error codes
Symptom or error FRU or action, in
10X
101: Interrupt failure. 102: Timer failure. 103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not accepted. 107: NMI test failure. 108: Timer bus test failure.
109: Low meg-chip
select test.
110
System board parity.
111
I/O parity.
11XX
1101: Serial_A test failure.
12XX
1201: Serial_B test failure.
158
No hard disk password has been set even though the supervisor password is set.
159
The hard disk password is not set the same as the supervisor password.
sequence
1. System board
1. Go to “Testing the
computer” on page 7.
2. DIMM card.
3. If the expansion unit is attached to the computer, detach it.
4. System board.
1. Go to “Testing the
computer” on page 7.
2. Expansion unit or port replicator.
3. System board.
1. Go to “Testing the
computer” on page 7.
2. Serial device.
3. Communication cable.
4. System board.
1. Go to “Testing the
computer” on page 7.
2. System board (infrared).
Set the password for the hard disk drive.
Set the correct password for the hard disk drive.
18 ThinkPad 600X Hardware Maintenance Manual
Loading...
+ 4 hidden pages