IBM ThinkPad 600E Service Manual

IBM Mobile Systems
ThinkPad 600/600E (2645) Hardware Maintenance Manual
June 1999
S10L-9619-03
Note
Fourth Edition (June 1999)
The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT ANY WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE LIMITED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer or express or implied warranties in certain transactions; therefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements or changes to the products or the programs described in this publication at any time.
It is possible that this publication may contain references to, or information about, IBM products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that IBM intends to announce such IBM products, programming, or services in your country.
Requests for technical information about IBM products should be made to your IBM authorized dealer or your IBM marketing representative.
Copyright International Business Machines Corporation 1998, 1999. All rights reserved. Note to
U.S. Government Users – Documentation related to restricted rights – Use, duplication, or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp.
Related Publications
The following product publications are available through IBM or your IBM Authorized Dealer.
Publication Part, Form Number
Mobile Systems HMM Volume 1: Laptop, Notebook, Portable, and ThinkPad Computers (Models L40, CL57, N45, N51, P70/P75, ThinkPad 300, 350, 500, 510, 710T, Expansion Unit, Dock I, Dock II)
Mobile Systems HMM Volume 2: ThinkPad Computers (Models 340, 355, 360, 370, 700, 701, 720, 750, 755)
Mobile Systems HMM Volume 3: ThinkPad Computers (Models 365, 380, 385, 560, 760, SelectaDock)
Mobile Systems HMM Volume 4: ThinkPad Computers (Models 380, 385, 560, 760, 765)
30H2356, S82G-1501-01
30H2357, S82G-1502-03
84H8099, S82G-1503-05
05L1271, S05L-1270-01
Related Diskettes
The following diskettes are available through IBM or your IBM Authorized Dealer.
iii
Diskette Part, Form Number
ThinkPad 300 (2615) Advanced Diagnostics Diskette
ThinkPad 350, 350C, 425, 425C (2618) Advanced Diagnostics Diskette
ThinkPad 365 (2625) Advanced Diagnostics Diskette
ThinkPad 380/385 (2635) Maintenance Diskette
ThinkPad 390/i Series 1700 (2626, 2627) Diagnostic and Utilities Diskettes
ThinkPad 500 (2603) Advanced Diagnostics Diskette
ThinkPad 510 (2604) Advanced Diagnostics Diskette
ThinkPad 700 (9552) Reference Diskette
ThinkPad 700C (9552) Reference Diskette
ThinkPad 720/720C (9552) Reference Diskette
ThinkPad Hardware Maintenance Diskette (for all Models 355, 360, 560, 750, 755, 760)
ThinkPad Dock I (3545) 71G4140, S71G-4140 Docking Station (3550) 42G2428, S42G-2428 Data/Fax Modem 61G1556, S61G-1556 FaxConcentrator/A 84F8540, S84F-8540
33G9361, S33G-9361
A211000, GA21-1000
76H7578, S30H-2498
06J0333, S06J-0333
10L9942, S10L-9942
71G3702, S71G-3702
83G8095, S83G-8095
42G2017, S42G-2017
42G2023, S42G-2023
61G1194, S61G-1194
78H5384, S78H-5384
iv
Contents
General Descriptions . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . 1
Important Service Information .......... 1
Drive and Diskette Compatibility Matrix ..... 3
Safety Notices (Multi-lingual Translations) .... 3
Safety Information . . . . . . . . . . . . . . . 10
Laser Compliance Statement ........... 14
Read This First .................. 17
FRU Replacement Notices ............ 19
LCD Replacement Notice ........... 19
Screw Notices . . . . . . . . . . . . . . . . . 19
System Board Replacement Notice ....... 20
CPU Card Replacement Notice (600E and 770X
Only) . . . . . . . . . . . . . . . . . . . . 22
DC-DC Card Replacement Notice (770X Only) . 22
Related Service Information ............ 23
How to Use Error Messages .......... 23
How to Diagnose Multiple FRUs ........ 23
Reset Switch . . . . . . . . . . . . . . . . . 23
Running a Low-Level Format .......... 23
Service Web Site ............... 24
Passwords . . . . . . . . . . . . . . . . . . 24
Power Management Features ......... 25
Fn Key Combinations ............. 29
Checkout Guide . . . . . . . . . . . . . . . . . 30
Audio Checkout . . . . . . . . . . . . . . . . 31
Diskette Drive Checkout ............ 31
Fan Checkout . . . . . . . . . . . . . . . . . 32
Indicator LED Checkout ............ 32
Indicator Panel Check Out ........... 32
Keyboard or Auxiliary Input Device Checkout . . 32
Memory Checkout . . . . . . . . . . . . . . . 33
Modem (DSP) Checkout ............ 34
Port Replicator Checkout ............ 35
Power Systems Checkout ........... 35
System Board and CPU Card Checkout ..... 38
TrackPoint Checkout . . . . . . . . . . . . . . 39
Running the Diagnostics .............. 39
PC Card Slots Test .............. 41
Universal Serial Bus (USB) Test ........ 41
Displaying the Error Log ............ 42
Checking the Installed Devices List ....... 42
Diagnostic Error Codes ............ 42
ThinkPad 600 . . . . . . . . . . . . . . . . . . 47
Model-Unique Functions . . . . . . . . . . . . . . 49
Product Overview . . . . . . . . . . . . . . . 49
Status Indicators . . . . . . . . . . . . . . . . 51
Symptom-to-FRU Index . . . . . . . . . . . . . . 52
Numeric Error Codes .............. 52
Copyright IBM Corp. 1999 v
Beep Symptoms . . . . . . . . . . . . . . . . 57
Audio-Related Symptoms . . . . . . . . . . . 58
CD-ROM-Related Symptoms . . . . . . . . . . 58
Function-Related Symptoms . . . . . . . . . . 60
Indicator-Related Symptoms . . . . . . . . . . 60
Infrared-Related Symptoms . . . . . . . . . . . 61
Keyboard- or TrackPoint-Related Symptoms . . . 61
LCD-Related Symptoms . . . . . . . . . . . . 62
Modem (DSP)-Related Symptoms ....... 62
PC Card-Related Symptoms .......... 63
Peripheral-Device-Related Symptoms . . . . . . 63
Power-Related Symptoms . . . . . . . . . . . 64
Other Symptoms . . . . . . . . . . . . . . . . 64
Intermittent Problems . . . . . . . . . . . . . 64
Undetermined Problems . . . . . . . . . . . . 64
FRU Removals and Replacements ......... 66
1010 Backup Battery . . . . . . . . . . . . . 67
1020 DIMM . . . . . . . . . . . . . . . . . . 68
1030 Battery Pack . . . . . . . . . . . . . . 69
1040 Hard Disk Drive ............. 70
1050 UltraslimBay Device . . . . . . . . . . . 71
1060 Keyboard Assembly . . . . . . . . . . . 72
1070 Keyboard . . . . . . . . . . . . . . . . 74
1080 Speakers . . . . . . . . . . . . . . . . 75
1085 Speaker Cable . . . . . . . . . . . . . 77
1090 LCD Assembly . . . . . . . . . . . . . 78
1100 PC Card (PCMCIA) Slot Assembly .... 79
1110 Modem Card . . . . . . . . . . . . . . 80
1115 System Kit for RFID ........... 81
1120 Sub Card . . . . . . . . . . . . . . . . 81
1130 CPU Card and Fan ........... 83
1140 Guide Rail, Mic. Cable, or TV Out Card . . 85
1150 System Board . . . . . . . . . . . . . . 87
2010 LCD Front Cover ............ 88
2020 LCD Hinges and Cables ......... 91
2030 Inverter Card . . . . . . . . . . . . . . 96
Locations . . . . . . . . . . . . . . . . . . . . . 99
Front View . . . . . . . . . . . . . . . . . . 99
Bottom View . . . . . . . . . . . . . . . . . 100
Password Pads . . . . . . . . . . . . . . . 100
Rear View . . . . . . . . . . . . . . . . . . 101
Parts List . . . . . . . . . . . . . . . . . . . . 102
Model 600 . . . . . . . . . . . . . . . . . . 102
LCD FRU (TFT) ............... 105
Model 600E . . . . . . . . . . . . . . . . . 108
LCD FRU (TFT) ............... 111
Keyboard . . . . . . . . . . . . . . . . . . 112
Miscellaneous Parts . . . . . . . . . . . . . 112
Modem Kit . . . . . . . . . . . . . . . . . 114
Common Parts List ............. 115
Notices . . . . . . . . . . . . . . . . . . . . . 117
Trademarks . . . . . . . . . . . . . . . . . 117
vi

Introduction

General Descriptions

This chapter includes the descriptions for all ThinkPad models. Some descriptions might not apply to the particular computer.
Introduction Important Service Information
Important
Diskette fixes are customer installable. The diskette fixes are located on the PC Company Bulletin Board Service (BBS). The direct phone line for modem connection is 919-557-0001 or tieline 255-0001.
Advise customers to contact the PC Company HelpCenter at 800-772-2227 if they need assistance in obtaining or installing any diskette fixes.
Customers in Canada should call IBM HelpPC at 800-565-3344 for assistance or down-load information. The Canadian BBS phone numbers are:
Montreal 514-938-3022 Toronto 905-316-4255 Vancouver 604-664-6464 Winnipeg 204-934-2735
FRU Replacement Strategy
Before Replacing Parts
Ensure that all diskette fixes are installed prior to replacing any FRUs listed in this manual.
Use the following strategy to prevent unnecessary FRU replacement and service expense:
If you are instructed to replace a FRU and that
does not correct the problem, reinstall the original FRU before you continue.
Some computers have both a processor board and a
system board. If you are instructed to replace either the processor board or the system board, and the first board that you replaced does not correct the problem, reinstall the original board, then replace the other (processor or system) board.
If an adapter or device consists of more than one
FRU, an error code may be caused by any of the FRUs. Before replacing the adapter or device, remove the FRUs, one by one, to see if the symptoms change. Replace only the FRU that changed the symptoms.
Copyright IBM Corp. 1999 1
Introduction
Attention
A customized setup configuration (other than default settings) may exist on the computer you are servicing. Running Automatic Configuration may alter those settings. Note the current configuration settings (using the View Configuration option) and verify that the settings are in place when service is complete.
Hard Disk Drive Replacement Strategy:
Always try to run a low-level format before replacing a hard disk drive.
Attention
The drive startup sequence in the computer you are servicing might have been changed. Be extremely careful during write operations such as copying, saving, or formatting. Data or programs can be overwritten if you select an incorrect drive.
How to Use Error Messages: Use the error
codes displayed on the screen to diagnose failures. If more than one error code is displayed, begin the diagnosis with the first error code. The cause of the first error code can result in false error codes being displayed. If no error code is displayed, see if the error symptom is listed in the Symptom-to-FRU Index for the computer you are servicing.
How to Read POST Error Messages: POST
error messages are displayed on the screen as three, four, five, or eight digits. The error messages that can be displayed as shorter POST messages are highlighted in this index. Some digits will represent different information for SCSI errors versus non-SCSI errors.
The following example shows which digits display the shorter POST error messages and also defines the SCSI information in an eight-digit error message.
Shorter POST Messages
"""""""""""""""""""""
" " " " " """"""""""""""""""""""""""""""""""""""""" " ð" ð" ð" ð" ð" ð" ð" ð" """""""""""""""""""""""""""""""""""""""""
" " " " " " " "
Reserved """"""Size (SCSI)
""""""""""" " " Slot Number (SCSI)
ID (SCSI)
All SCSI devices are set to a different SCSI ID. Duplicate SCSI ID settings can generate a false error message. Use the SCSI ID to determine whether the error message is coming from an internal or an external device.
2
Device Code " Logical Unit Number (SCSI)
Introduction

Drive and Diskette Compatibility Matrix

The following table provides identification information for
3.5-inch drives.
Diskette Drive Identifying Mark
3.5-Inch - 1.44MB 1.44 on the eject button
3.5-Inch - 2.88MB 2.88 on the eject button
The following table provides compatibility information for
3.5-inch diskettes and 3.5-inch diskette drives.
Diskette Capacity
1.0MB Read/Write Read/Write
2.0MB Read/Write Read/Write
4.0MB Not Compatible Read/Write
1.44MB Drive 2.88MB Drive
The following table provides identification information for
5.25-inch diskette drives.
Diskette Drive Identifying Mark
5.25-Inch - 360KB (External) Asterisk on bezel
5.25-Inch - 1.2MB (Internal) 1.2 on the eject button
The following table provides compatibility information for
5.25-inch diskettes and 5.25-inch diskette drives.
Diskette Capacity
360KB Read/Write Read/Write
1.2MB Not Compatible Read/Write
360KB Drive 1.2MB Drive
Note
A 360KB diskette written to or formatted on a 1.2MB drive can be read reliably only on a 1.2MB drive.

Safety Notices (Multi-lingual Translations)

In this manual, safety notices appear in English with a page number reference to the appropriate multi-lingual, translated safety notice found in this section.
The following safety notices are provided in English, French, German, Italian, and Spanish languages.
General Descriptions
3
Introduction
Safety Notice 1
Before the computer is powered-on after FRU replacement, make sure all screws, springs, or other small parts are in place and are not left loose inside the computer. Verify this by shaking the computer and listening for rattling sounds. Metallic parts or metal flakes can cause electrical shorts.
Avant de remettre l'ordinateur sous tension après remplacement d'une unité en clientèle, vérifiez que tous les ressorts, vis et autres pièces sont bien en place et bien fixées. Pour ce faire, secouez l'unité et assurez-vous qu'aucun bruit suspect ne se produit. Des pièces métalliques ou des copeaux de métal pourraient causer un court-circuit.
Bevor nach einem FRU-Austausch der Computer wieder angeschlossen wird, muß sichergestellt werden, daß keine Schrauben, Federn oder andere Kleinteile fehlen oder im Gehäuse vergessen wurden. Der Computer muß geschüttelt und auf Klappergeräusche geprüft werden. Metallteile oder
-splitter können Kurzschlüsse erzeugen. Prima di accendere l'elaboratore dopo che é stata
effettuata la sostituzione di una FRU, accertarsi che tutte le viti, le molle e tutte le altri parti di piccole dimensioni siano nella corretta posizione e non siano sparse all'interno dell'elaboratore. Verificare ciÞ scuotendo l'elaboratore e prestando attenzione ad eventuali rumori; eventuali parti o pezzetti metallici possono provocare cortocircuiti pericolosi.
Antes de encender el sistema despues de sustituir una FRU, compruebe que todos los tornillos, muelles y demás piezas pequeñas se encuentran en su sitio y no se encuentran sueltas dentro del sistema. Compruébelo agitando el sistema y escuchando los posibles ruidos que provocarían. Las piezas metálicas pueden causar cortocircuitos eléctricos.
4
Introduction
Safety Notice 2
Some standby batteries contain a small amount of nickel and cadmium. Do not disassemble it, recharge it, throw it into fire or water, or short-circuit it. Dispose of the battery as required by local ordinances or regulations. Use only the battery in the appropriate parts listing. Use of an incorrect battery can result in ignition or explosion of the battery.
Certaines batteries de secours contiennent du nickel et du cadmium. Ne les démontez pas, ne les rechargez pas, ne les exposez ni au feu ni à l'eau. Ne les mettez pas en court-circuit. Pour les mettre au rebut, conformez-vous à la réglementation en vigueur. Lorsque vous remplacez la pile de sauvegarde ou celle de l'horloge temps réel, veillez à n'utiliser que les modèles cités dans la liste de pièces détachées adéquate. Une batterie ou une pile inappropriée risque de prendre feu ou d'exploser.
Die Bereitschaftsbatterie, die sich unter dem Diskettenlaufwerk befindet, kann geringe Mengen Nickel und Cadmium enthalten. Sie darf nur durch die Verkaufsstelle oder den IBM Kundendienst ausgetauscht werden. Sie darf nicht zerlegt, wiederaufgeladen, kurzgeschlossen, oder Feuer oder Wasser ausgesetzt werden. Die Batterie kann schwere Verbrennungen oder Verätzungen verursachen. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Bereitschafts- oder Systembatterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
Alcune batterie di riserva contengono una piccola quantità di nichel e cadmio. Non smontarle, ricaricarle, gettarle nel fuoco o nell'acqua né cortocircuitarle. Smaltirle secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). Quando si sostituisce la batteria dell'RTC (real time clock) o la batteria di supporto, utilizzare soltanto i tipi inseriti nell'appropriato Catalogo parti. L'impiego di una batteria non adatta potrebbe determinare l'incendio o l'esplosione della batteria stessa.
Algunas baterías de reserva contienen una pequeña cantidad de níquel y cadmio. No las desmonte, ni recargue, ni las eche al fuego o al agua ni las cortocircuite. Deséchelas tal como dispone la normativa local. Utilice sólo baterías que se encuentren en la lista de piezas. La utilización de una batería no apropiada puede provocar la ignición o explosión de la misma.
General Descriptions 5
Introduction
Safety Notice 3
The battery pack contains small amounts of nickel. Do not disassemble it, throw it into fire or water, or short-circuit it. Dispose of the battery pack as required by local ordinances or regulations. Use only the battery in the appropriate parts listing when replacing the battery pack. Use of an incorrect battery can result in ignition or explosion of the battery.
La batterie contient du nickel. Ne la démontez pas, ne l'exposez ni au feu ni à l'eau. Ne la mettez pas en court-circuit. Pour la mettre au rebut, conformez-vous à la réglementation en vigueur. Lorsque vous remplacez la batterie, veillez à n'utiliser que les modèles cités dans la liste de pièces détachées adéquate. En effet, une batterie inappropriée risque de prendre feu ou d'exploser.
Akkus enthalten geringe Mengen von Nickel. Sie dürfen nicht zerlegt, wiederaufgeladen, kurzgeschlossen, oder Feuer oder Wasser ausgesetzt werden. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Batterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
La batteria contiene piccole quantità di nichel. Non smontarla, gettarla nel fuoco o nell'acqua né cortocircuitarla. Smaltirla secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). Quando si sostituisce la batteria, utilizzare soltanto i tipi inseriti nell'appropriato Catalogo parti. L'impiego di una batteria non adatta potrebbe determinare l'incendio o l'esplosione della batteria stessa.
Las baterías contienen pequeñas cantidades de níquel. No las desmonte, ni recargue, ni las eche al fuego o al agua ni las cortocircuite. Deséchelas tal como dispone la normativa local. Utilice sólo baterías que se encuentren en la lista de piezas al sustituir la batería. La utilización de una batería no apropiada puede provocar la ignición o explosión de la misma.
6
Introduction
Safety Notice 4
The lithium battery can cause a fire, explosion, or severe burn. Do not recharge it, remove its polarized connector, disassemble it, heat it above 100°C (212°F), incinerate it, or expose its cell contents to water. Dispose of the battery as required by local ordinances or regulations. Use only the battery in the appropriate parts listing. Use of an incorrect battery can result in ignition or explosion of the battery.
La pile de sauvegarde contient du lithium. Elle présente des risques d'incendie, d'explosion ou de brûlures graves. Ne la rechargez pas, ne retirez pas son connecteur polarisé et ne la démontez pas. Ne l'exposez pas à une temperature supérieure à 100°C, ne la faites pas brûler et n'en exposez pas le contenu à l'eau. Mettez la pile au rebut conformément à la réglementation en vigueur. Une pile inappropriée risque de prendre feu ou d'exploser.
Die Systembatterie ist eine Lithiumbatterie. Sie kann sich entzünden, explodieren oder schwere Verbrennungen hervorrufen. Batterien dieses Typs dürfen nicht aufgeladen, zerlegt, über 100 C erhitzt oder verbrannt werden. Auch darf ihr Inhalt nicht mit Wasser in Verbindung gebracht oder der zur richtigen Polung angebrachte Verbindungsstecker entfernt werden. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Batterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
La batteria di supporto e una batteria al litio e puo incendiarsi, esplodere o procurare gravi ustioni. Evitare di ricaricarla, smontarne il connettore polarizzato, smontarla, riscaldarla ad una temperatura superiore ai 100 gradi centigradi, incendiarla o gettarla in acqua. Smaltirla secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). L'impiego di una batteria non adatta potrebbe determinare l'incendio o l'esplosione della batteria stessa.
La bateria de repuesto es una bateria de litio y puede provocar incendios, explosiones o quemaduras graves. No la recargue, ni quite el conector polarizado, ni la desmonte, ni caliente por encima de los 100°C (212°F), ni la incinere ni exponga el contenido de sus celdas al agua. Deséchela tal como dispone la normativa local.
General Descriptions 7
Introduction
Safety Notice 5
If the LCD breaks and the fluid from inside the LCD gets into your eyes or on your hands, immediately wash the affected areas with water for at least 15 minutes. Seek medical care if any symptoms from the fluid are present after washing.
Si le panneau d'affichage à cristaux liquides se brise et que vous recevez dans les yeux ou sur les mains une partie du fluide, rincez-les abondamment pendant au moins quinze minutes. Consultez un médecin si des symptômes persistent après le lavage.
Die Leuchtstoffröhre im LCD-Bildschirm enthält Quecksilber. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Der LCD-Bildschirm besteht aus Glas und kann zerbrechen, wenn er unsachgemäß behandelt wird oder der Computer auf den Boden fällt. Wenn der Bildschirm beschädigt ist und die darin befindliche Flüssigkeit in Kontakt mit Haut und Augen gerät, sollten die betroffenen Stellen mindestens 15 Minuten mit Wasser abgespült und bei Beschwerden anschließend ein Arzt aufgesucht werden.
Nel caso che caso l'LCD si dovesse rompere ed il liquido in esso contenuto entrasse in contatto con gli occhi o le mani, lavare immediatamente le parti interessate con acqua corrente per almeno 15 minuti; poi consultare un medico se i sintomi dovessero permanere.
Si la LCD se rompe y el fluido de su interior entra en contacto con sus ojos o sus manos, lave inmediatamente las áreas afectadas con agua durante 15 minutos como mínimo. Obtenga atención medica si se presenta algún síntoma del fluido despues de lavarse.
8
Introduction
Safety Notice 6
To avoid shock, do not remove the plastic cover that surrounds the lower portion of the inverter card.
Afin d'éviter tout risque de choc électrique, ne retirez pas le cache en plastique protégeant la partie inférieure de la carte d'alimentation.
Aus Sicherheitsgründen die Kunststoffabdeckung, die den unteren Teil der Spannungswandlerplatine umgibt, nicht entfernen.
Per evitare scosse elettriche, non rimuovere la copertura in plastica che avvolge la parte inferiore della scheda invertitore.
Para evitar descargas, no quite la cubierta de plástico que rodea la parte baja de la tarjeta invertida.
Safety Notice 7
Though main batteries have low voltage, a shorted or grounded battery can produce enough current to burn combustible materials or personnel.
Bien que le voltage des batteries principales soit peu élevé, le court-circuit ou la mise à la masse d'une batterie peut produire suffisamment de courant pour brûler des matériaux combustibles ou causer des brûlures corporelles graves.
Obwohl Hauptbatterien eine niedrige Spannung haben, können sie doch bei Kurzschluß oder Erdung genug Strom abgeben, um brennbare Materialien zu entzünden oder Verletzungen bei Personen hervorzurufen.
Sebbene le batterie di alimentazione siano a basso voltaggio, una batteria in corto circuito o a massa può fornire corrente sufficiente da bruciare materiali combustibili o provocare ustioni ai tecnici di manutenzione.
Aunque las baterías principales tienen un voltaje bajo, una batería cortocircuitada o con contacto a tierra puede producir la corriente suficiente como para quemar material combustible o provocar quemaduras en el personal.
General Descriptions 9
Introduction
Safety Notice 8
Before removing any FRU, power-off the computer, unplug all power cords from electrical outlets, remove the battery pack, then disconnect any interconnecting cables.
Avant de retirer une unité remplaçable en clientèle, mettez le système hors tension, débranchez tous les cordons d'alimentation des socles de prise de courant, retirez la batterie et déconnectez tous les cordons d'interface.
Die Stromzufuhr muß abgeschaltet, alle Stromkabel aus der Steckdose gezogen, der Akku entfernt und alle Verbindungskabel abgenommen sein, bevor eine FRU entfernt wird.
Prima di rimuovere qualsiasi FRU, spegnere il sistema, scollegare dalle prese elettriche tutti i cavi di alimentazione, rimuovere la batteria e poi scollegare i cavi di interconnessione.
Antes de quitar una FRU, apague el sistema, desenchufe todos los cables de las tomas de corriente eléctrica, quite la batería y, a continuación, desconecte cualquier cable de conexión entre dispositivos.

Safety Information

The following section contains the safety information that you need to be familiar with before servicing an IBM mobile computer.
General Safety: Follow these rules to ensure
general safety:
Observe good housekeeping in the area of the
machines during and after maintenance.
When lifting any heavy object:
1. Ensure you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly or twist when you attempt to lift.
4. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the muscles in your back.
objects that weigh more than 16 kg (35 lb) or objects that you think are too heavy for you.
Do not perform any action that causes hazards to the
customer, or that makes the equipment unsafe.
Before you start the machine, ensure that other
service representatives and the customer's personnel are not in a hazardous position.
10
Do not attempt to lift any
Introduction
Place removed covers and other parts in a safe
place, away from all personnel, while you are servicing the machine.
Keep your tool case away from walk areas so that
other people will not trip over it.
Do not wear loose clothing that can be trapped in the
moving parts of a machine. Ensure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it.
Insert the ends of your necktie or scarf inside clothing
or fasten it with a nonconductive clip, approximately 8 centimeters (3 inches) from the end.
Do not wear jewelry, chains, metal-frame eyeglasses,
or metal fasteners for your clothing. Attention: Metal objects are good electrical
conductors.
Wear safety glasses when you are: hammering,
drilling soldering, cutting wire, attaching springs, using solvents, or working in any other conditions that might be hazardous to your eyes.
After service, reinstall all safety shields, guards,
labels, and ground wires. Replace any safety device that is worn or defective.
Reinstall all covers correctly before returning the
machine to the customer.
Electrical Safety: Observe the following rules when
working on electrical equipment.
Important
Use only approved tools and test equipment. Some hand tools have handles covered with a soft material that does not insulate you when working with live electrical currents.
Many customers have, near their equipment, rubber floor mats that contain small conductive fibers to decrease electrostatic discharges. Do not use this type of mat to protect yourself from electrical shock.
Find the room emergency power-off (EPO) switch,
disconnecting switch, or electrical outlet. If an electrical accident occurs, you can then operate the switch or unplug the power cord quickly.
Do not work alone under hazardous conditions or
near equipment that has hazardous voltages.
Disconnect all power before:
– Performing a mechanical inspection – Working near power supplies – Removing or installing main units
Before you start to work on the machine, unplug the
power cord. If you cannot unplug it, ask the customer to power-off the wall box that supplies power to the machine and to lock the wall box in the off position.
General Descriptions
11
Introduction
If you need to work on a machine that has
electrical circuits, observe the following precautions:
– Ensure that another person, familiar with the
power-off controls, is near you. Attention: Another person must be there to
switch off the power, if necessary.
– Use only one hand when working with
powered-on electrical equipment; keep the other hand in your pocket or behind your back.
Attention: There must be a complete circuit to cause electrical shock. By observing the above rule, you may prevent a current from passing through your body.
– When using testers, set the controls correctly
and use the approved probe leads and accessories for that tester.
– Stand on suitable rubber mats (obtained locally,
if necessary) to insulate you from grounds such as metal floor strips and machine frames.
Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages.
Regularly inspect and maintain your electrical hand
tools for safe operational condition.
Do not use worn or broken tools and testers.
Never assume
from a circuit. First, powered-off.
Always look carefully for possible hazards in your
work area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds.
Do not touch live electrical circuits with the reflective
surface of a plastic dental mirror. The surface is conductive; such touching can cause personal injury and machine damage.
Do not service the following parts
when they are removed from their normal operating places in a machine:
– Power supply units
– Pumps
– Blowers and fans
– Motor generators and similar units. (This practice ensures correct
grounding of the units.)
If an electrical accident occurs:
Use caution; do not become a victim
yourself.
– Switch off power. – Send another person to get medical aid.
that power has been disconnected
check
that it has been
with the power on
exposed
12
Introduction
Safety Inspection Guide: The intent of this
inspection guide is to assist you in identifying potentially unsafe conditions on these products. Each machine, as it was designed and built, had required safety items installed to protect users and service personnel from injury. This guide addresses only those items. However, good judgment should be used to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide.
If any unsafe conditions are present, you must determine how serious the apparent hazard could be and whether you can continue without first correcting the problem.
Consider these conditions and the safety hazards they present:
Electrical hazards, especially primary power (primary
voltage on the frame can cause serious or fatal electrical shock).
Explosive hazards, such as a damaged CRT face or
bulging capacitor
Mechanical hazards, such as loose or missing
hardware
The guide consists of a series of steps presented in a checklist. Begin the checks with the power off, and the power cord disconnected.
Checklist:
1. Check exterior covers for damage (loose, broken, or sharp edges).
2. Power-off the computer. Disconnect the power cord.
3. Check the power cord for:
a. A third-wire ground connector in good condition.
Use a meter to measure third-wire ground continuity for 0.1 ohm or less between the external ground pin and frame ground.
b. The power cord should be the appropriate type
as specified in the parts listings.
c. Insulation must not be frayed or worn.
4. Remove the cover.
5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations.
6. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage.
7. Check for worn, frayed, or pinched cables.
8. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with.
Handling Electrostatic Discharge-Sensitive Devices: Any computer part containing transistors or
integrated circuits (ICs) should be considered sensitive to electrostatic discharge (ESD). ESD damage can occur when there is a difference in charge between objects.
General Descriptions
13
Introduction
Protect against ESD damage by equalizing the charge so that the machine, the part, the work mat, and the person handling the part are all at the same charge.
Notes
1. Use product-specific ESD procedures when they exceed the requirements noted here.
2. Make sure that the ESD protective devices you use have been certified (ISO 9000) as fully effective.
When handling ESD-sensitive parts:
Keep the parts in protective packages until they are
inserted into the product.
Avoid contact with other people.Wear a grounded wrist strap against your skin to
eliminate static on your body.
Prevent the part from touching your clothing. Most
clothing is insulative and retains a charge even when you are wearing a wrist strap.
Use the black side of a grounded work mat to provide
a static-free work surface. The mat is especially useful when handling ESD-sensitive devices.
Select a grounding system, such as those listed
below, to provide protection that meets the specific service requirement.
Note
The use of a grounding system is desirable but not required to protect against ESD damage.
– Attach the ESD ground clip to any frame ground,
ground braid, or green-wire ground.
– Use an ESD common ground or reference point
when working on a double-insulated or battery-operated system. You can use coax or connector-outside shells on these systems.
– Use the round ground-prong of the AC plug on
AC-operated computers.
Grounding Requirements: Electrical grounding of
the computer is required for operator safety and correct system function. Proper grounding of the electrical outlet can be verified by a certified electrician.

Laser Compliance Statement

Some IBM Personal Computer models are equipped from the factory with a CD-ROM drive. CD-ROM drives are also sold separately as options. The CD-ROM drive is a laser product. The CD-ROM drive is certified in the U.S. to conform to the requirements of the Department of Health and Human Services 21 Code of Federal Regulations (DHHS 21 CFR) Subchapter J for Class 1 laser products.
14
Introduction
Elsewhere, the drive is certified to conform to the requirements of the International Electrotechnical Commission (IEC) 825 and CENELEC EN 60 825 for Class 1 laser products.
When a CD-ROM drive is installed, note the following.
CAUTION:
Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.
O uso de controles, ajustes ou desempenho de procedimentos diferentes daqueles aqui especificados pode resultar em perigosa exposição à radiação.
Pour éviter tout risque d'exposition au rayon laser, respectez les consignes de réglage et d'utilisation des commandes, ainsi que les procédures décrites.
Werden Steuer- und Einstellelemente anders als hier festgesetzt verwendet, kann gefährliche Laserstrahlung auftreten.
L'utilizzo di controlli, regolazioni o l'esecuzione di procedure diverse da quelle specificate possono provocare l'esposizione a
El uso de controles o ajustes o la ejecución de procedimientos distintos de los aquí especificados puede provocar la exposición a radiaciones peligrosas.
Opening the CD-ROM drive could result in exposure to hazardous laser radiation. There are no serviceable parts inside the CD-ROM drive. Do not open.
General Descriptions 15
Introduction
Some CD-ROM drives contain an embedded Class 3A or Class 3B laser diode. Note the following.
DANGER:
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Radiação por raio laser ao abrir. Não olhe fixo no feixe de luz, não olhe diretamente por meio de instrumentos óticos e evite exposição direta com o feixe de luz.
Rayonnement laser si carter ouvert. Évitez de fixer le faisceau, de le regarder directement avec des instruments optiques, ou de vous exposer au rayon.
Laserstrahlung bei geöffnetem Gerät. Nicht direkt oder über optische Instrumente in den Laserstrahl sehen und den Strahlungsbereich meiden.
Kinyitáskor lézersugár ! Ne nézzen bele se szabad szemmel, se optikai eszközökkel. Kerülje a sugárnyalábbal való érintkezést !
Aprendo l'unità vengono emesse radiazioni laser. Non fissare il fascio, non guardarlo direttamente con strumenti ottici e evitare l'esposizione diretta al fascio.
Radiación láser al abrir. No mire fijamente ni examine con instrumental óptico el haz de luz. Evite la exposición directa al haz.
16

Read This First

Read This First
Before you go to the checkout guide, be sure to read this section.
Important Notes
Only certified trained personnel should
service the computer.
Read the entire FRU removal and replacement
page before replacing any FRU.
Use new nylon-coated screws when you
replace FRUs.
Be extremely careful during such write
operations as copying, saving, or formatting.
Drives in the computer that you are servicing might have been rearranged, or the drive startup sequence might have been altered. If you select an incorrect drive, data or programs might be overwritten.
Replace FRUs only for the correct model.
When you replace a FRU, make sure the model of the machine and FRU part number are correct by referring to the FRU parts list.
A FRU should not be replaced because of a
single, unreproducible failure. Single failures
can occur from a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists. If this is suspected, clear the error log and run the test again. Do not replace any FRUs if log errors do not reappear.
Be careful not to replace a nondefective FRU.
What to Do First: The servicer must include the
following in the parts exchange form or parts return form that is attached to the returned FRU:
1. Name and phone number of servicer
2. Date of service
3. Date that the machine failed
4. Date of purchase
5. Failure symptoms, error codes appearing on the
display, and beep symptoms
6. Procedure index and page number in which the
failing FRU was detected
7. Failing FRU name and part number
8. Machine type, model number, and serial number
9. Customer's name and address
General Descriptions
17
Read This First
Before checking problems with the computer, determine whether the damage is covered under the warranty by referring to the following:
Note
During the warranty period, the customer may be responsible for repair costs if the computer damage was caused by misuse, accident, modification, unsuitable physical or operating environment, or improper maintenance by the customer. The following list provides some common items that are not covered under warranty and some symptoms that may indicate that the system was subjected to stress beyond normal use.
The following is not covered under warranty:
LCD panel cracked from the application of
excessive force or from being dropped.
Scratched (cosmetic) parts.Cracked or broken plastic parts, broken latches,
broken pins, or broken connectors caused by excessive force.
Damage caused by liquid spilled into the system.Damage caused by the improper insertion of a
PC Card or the installation of an incompatible card.
Damage caused by foreign material in the FDD.Diskette drive damage caused by the diskette
drive cover being pressed or by the insertion of a diskette with multiple labels.
Damaged or bent diskette eject button.Fuses blown by attachment of a nonsupported
device.
Forgotten computer password (making the
computer unusable).
The following symptoms might indicate damage caused by nonwarranted activities:
Missing parts might be a symptom of
unauthorized service or modification.
HDD spindles can become noisy from being
subjected to excessive force or from being dropped.
I9990303 errors can be caused by exposure to
strong magnetic fields.
18

FRU Replacement Notices

FRU Replacement Notices
This section contains notices for removal and replacement. Read this section carefully before replacing any FRU.

LCD Replacement Notice

The TFT LCD for the computer contains over 2,359,296 thin-film transistors (TFTs). A small number of missing, discolored, or lighted dots (on all the time) is characteristic of TFT LCD technology, but excessive pixel problems can cause viewing concerns. The LCD should be replaced if the number of missing, discolored, or lighted dots in any background is 5 or more.

Screw Notices

This computer uses special nylon-coated screws with the following characteristics:
They maintain tight connections.They do not easily come loose, even with shock or
vibration.
They need additional force to tighten.They should be used only once.
Do the following when you service this machine:
Keep the screw kit (P/N 05K4841) in your tool bag.Always use new screws if you are instructed.Use a torque screwdriver if you have one.
Loose screws can cause a reliability problem. The IBM ThinkPad computer addresses this problem with nylon-coated screws. Tighten screws as follows:
Plastic to plastic
Turn an additional 90 degrees after the screw head touches the surface of the plastic part:
Logic card to plastic
Turn an additional 180 degrees after the screw head touches the surface of the logic card:
General Descriptions
19
FRU Replacement Notices
Torque driver
If you have a torque driver, refer to the “Torque” column with each step.
Make sure you use the correct screw, and tighten all
screws firmly to the torque shown in the table if you have a torque screwdriver. Never use a screw that
you removed. Use a new one. Make sure the screws are tightened firmly

System Board Replacement Notice

Notice for 770E and 600: Restoring the System
Unit Serial Number: The EEPROM on the system board
contains vital product data (VPD), such as the system unit serial number and the system board serial number. You must restore the system unit serial number to its original number when the system board is replaced.
To restore the system unit serial number, do the following:
1. Press and hold F1 and power on the computer.
2. Hold down F1 until the Easy-Setup menu appears.
3. Click on Config.
4. Press Ctrl + N. The System Unit Serial Number menu appears.
5. Follow the instructions on the menu.
Notes:
1. Do not power-off the computer during the restoration process.
2. The serial number label is attached to the bottom of the computer.
Notice for 770X and 600E
Serial Numbers:
manufactured, the EEFROM on the system board was loaded with the serial numbers of the system and all major components. The EEPROM contains the following serial numbers:
System board serial numberSystem unit serial numberCPU Card serial numberDC-DC Card serial number
20
When the computer was
FRU Replacement Notices
You must restore each of those serial numbers except the system board serial number to its original number when replacing the system board.
To save the original serial numbers, do the following:
1. Boot from DOS, or open an MS-DOS prompt.
2. Insert the ThinkPad Hardware Maintenance Diskette Version 1.05 into the diskette drive.
3. Enter A:\SERUPDT.EXE at the DOS prompt. The usage of this tool is displayed. Note: SERUPDT.EXE is in the ThinkPad Hardware
Maintenance Diskette Version 1.05 or a later version.
4. Enter SERUPDT R Each serial numbers is displayed with its device type.
Write down all numbers except the system board serial number. The device type designations for the each serial number are as follows:
08: CPU card serial number 20: System unit serial number 38: DC-DC card serial number 40: System board serial number 78–7F: Hard disk drive serial number
Note: You can disregard the hard disk drive serial
number.
To restore the serial numbers, do the following:
1. Boot from DOS, or open a MS-DOS prompt.
2. Enter SERUPDT.EXE at the DOS prompt. The usage of this tool is displayed.
3. Enter SERUPDT W nn SSSSSSS for each serial number you saved.
Notes:
a. nn is the device type, and SSSSSSS is the serial
number.
b. The system unit serial number is written in the
label attached on the bottom of the computer.
UUID:
128-bit number uniquely assigned to your computer at production and stored in the EEPROM of your system board. The algorithm that generates the unique number is designed to provide unique IDs until the year A.D. 3400. Consequently, no two computers in the world have the same number.
When you replace the system board, you must set the UUID on the new system board as follows:
General Descriptions
The Universally Unique IDentifier (UUID) is a
1. Press and hold F1 and power on the computer.
2. Hold down F1 until the Easy-Setup menu appears.
3. Click on Config.
21
FRU Replacement Notices
4. Press Ctrl + G. The UUID menu appears.
5. Press F5 to generate a new UUID, and press Enter to overwrite it to EEPROM.
CPU Card Replacement Notice (600E and 770X Only)
You must restore the CPU card serial number to its original number, when the CPU card is replaced. To save and restore the CPU card serial number, follow the instruction in “Serial Numbers” on page 20.

DC-DC Card Replacement Notice (770X Only)

You must restore the DC-DC card serial number to its original number, when the DC-DC card is replaced. To save and restore the DC-DC card serial number, follow the instruction in “Serial Numbers” on page 20.
22

Related Service Information

Related Service Information
This section provides information about the following:
“How to Use Error Messages”“How to Diagnose Multiple FRUs”
“Reset Switch”
“Running a Low-Level Format”“Service Web Site” on page 24“Passwords” on page 24“Power Management Features” on page 25“Fn Key Combinations” on page 29

How to Use Error Messages

Use the error codes displayed on the screen to diagnose failures. If more than one error code is displayed, begin the diagnosis with the first error code. Whatever caused the first error code can result in false error codes being displayed. If no error code is displayed, see if the error symptom is listed in the “Symptom-to FRU Index” section.

How to Diagnose Multiple FRUs

When the adapter or device has more than one FRU, the error code could be caused by any of them. Before replacing multiple FRUs, try removing or exchanging each FRU, one by one in the designated sequence, to see if the symptoms change.

Reset Switch

The Reset switch resets the system (regardless of the microcode status) and forces the power off. Use this push button to power off when power is not completely off or the microcode is in a hung state. See the “Locations” section of each model for Reset switch location.

Running a Low-Level Format

Do the following to format the hard disk. Attention: Make sure the drive address to be formatted is correct. This procedure erases all information on the disk.
1. Power off the computer.
2. Hold F1 until the Easy-Setup menu appears.
3. Click on the Test icon. The Basic Diagnostics menu appears.
4. Press Ctrl+A to enter advanced diagnostic mode. The ThinkPad FRU Connections window appears.
5. Click on Exit. The Keyboard Test menu appears.
6. Click on Exit again.
7. Press Ctrl+L. The Low-Level Format menu appears.
8. Follow the instructions on the screen
If you are prompted to use the Maintenance Diskette, do the following:
General Descriptions
23
Related Service Information
1. Insert the ThinkPad Hardware Maintenance Diskette Version 1.05 or a later version into the diskette drive and power on the computer.
2. Select Format the hard disk from the main menu.
3. Select the drive from the menu.
4. Follow the instructions on the screen.

Service Web Site

When the latest maintenance diskette and the system program service diskette are available, they will be posted on:
Maintenance diskette:
http://www.pc.ibm.com/files/searchfiles.html
(search for either MAINTENANCE or MAINT150)
System program service diskette:
http://pccbbs.raleigh.ibm.com/

Passwords

When the power-on password (POP), hard disk password (HDP), and supervisor password (PAP) are used, the following situations may occur:
If the POP is the same as the HDP
prompt appears, but the HDP prompt does not appear.
If the POP is not the same as the HDP
prompts appear.
The PAP and the HDP:
If the PAP is used, the HDP is enabled automatically, but no HDP prompt appears. The HDP is set the same as the PAP.
The ThinkPad computer that has the bay can support more than two HDPs.
POP
If the
or HDP-2), a POP prompt appears. The passwords are different.
If the
(HDP-1 or HDP-2):, both prompts appear.
If the
automatically enabled, but the HDP prompt does not appear. The HDP-1 and HDP-2 are then set to the same password as the PAP.
is the same as one of the
POP
is not the same as either of the
PAP
is used, the
HDP-1
or the
, the POP
, both
HDPs
(HDP-1
HDPs
HDP-2
is
Supervisor and Hard Disk Passwords: The
supervisor password and the hard disk password (HDP) are security features that are used to protect the system and the hard disk data from unauthorized access. No overriding capability is provided. If only a hard disk password is set, obtaining permission from the password owner to unlock the password is a prerequisite for running diagnostic tests and performing service. If both supervisor password and hard disk password are set, you can enter Easy-Setup by pressing the Enter key or by entering the
24
Related Service Information
power-on password at the supervisor password prompt. In this case, the Password, Start up, Network, and Initialize or Asset ID (for some models) icons cannot be selected.
Note: The supervisor password and hard disk password
cannot be replaced if they are forgotten. If the customer forgets the supervisor password, the system board must be replaced. If the customer forgets the hard disk password, the hard disk drive must be replaced.
How to Remove the Power-On Passwords:
If only the power-on password is set, do the following to remove the power-on password.
1. Power off the computer
2. Remove the DIMM cover on the bottom side of the computer.
3. Short-circuit the two password pads or put the jumper.
For the location of the password pads or jumper, see the “Locations” section for each model.
4. Under the short-circuit condition, power on the computer and wait until the POST ends.
After the POST ends, the password prompt does not appear. The power-on password is removed.
5. Reinstall the DIMM cover.
If both the power-on password and the supervisor password are set, do the following to remove the passwords:
1. Power on the computer by pressing and holding F1.
2. Enter the supervisor password. The Easy-Setup menu appears.
3. Click on the Password icon.
4. Click on the Power on icon.
5. Enter the supervisor password and press the Space bar.
6. Press Enter twice.
7. Click on Exit; then click on Restart. The power-on password has been removed.

Power Management Features

Three power management modes are provided by the computer to reduce power consumption and prolong battery power.
General Descriptions
25
Related Service Information
Standby Mode: In standby mode, the following
occurs:
The LCD backlight turns off.The hard disk drive motor stops.The speaker is muted.
Note: Standby mode in Windows 98 is called
mode
in Windows 95.
The computer enters standby mode when the Fn + F3 keys are pressed.
The computer exits standby and resumes normal operation when any key is pressed.
suspend
Suspend Mode: The following events occur in
addition to what occurs in standby mode when the computer enters suspend mode:
The LCD is powered off.The hard disk drive is powered off.The CPU stops.
Note: Suspend mode in Windows 95 is called
mode
in Windows 98.
The following events cause the computer to enter suspend mode:
The Fn + F4 keys are pressed.The LCD cover is closed. If you add a check mark to
the Will not suspend even if LCD is closed box in the Power Management Properties window, the computer will not enter suspend mode even if the LCD is closed. The LCD only turns off.
The Suspend button is selected in the Fuel-Gauge
program.
The specified time has elapsed from the last
operation with the keyboard, the TrackPoint, the hard disk drive, the parallel connector, or the diskette drive; or the AC Adapter is plugged in.
In Windows 95, the timer is set by the Suspend Timer selection in the Power Properties window. In Windows 98, the timer is set by the System standby timer selection in the Power Management Properties window.
The battery indicator blinks orange indicating that the
battery power is low. If you add a check mark to the Hibernate when battery becomes low box in the Power Management Properties window, the computer enters hibernation mode under this condition.
Note: Even if you don't set the low-battery alarm, the
charge indicator will let you know that the battery is low, and then the ThinkPad will automatically enter the power-saving mode. This default low-battery behavior is
standby
26
Related Service Information
independent of the operating system, so the computer might behave differently from your setting if you set the low-battery alarm. The computer chooses appropriately between your setting and the default setting.
Note: The computer cannot enter suspend mode if it is
attached to a docking station.
The following events cause the computer to resume operation from suspend mode:
The Fn key is pressed.The LCD cover is opened.The ring indicator (RI) is signaled by a serial device
or PC Card device.
The power switch is turned on.The resume timer is set. In Windows 95, you can set
the time with the Resume on timer selection in the Power Management Properties window. In Windows 98, the Scheduled Tasks setting has priority over the Resume on timer selection in the Power Management Properties window.
Note: The computer does not accept any event
immediately after it enters suspend mode. Therefore, wait a few seconds before taking any action to reenter operation mode.
Hibernation Mode
For the Windows NT User
A Windows NT user cannot create a hibernation file in a Windows NT system that uses the NTFS format system, the Windows NT default format. If you want to use hibernation mode, you should reinstall Windows NT with a FAT format system.
In hibernation mode, the following occurs:
The system status, RAM, VRAM, and setup data are
stored on the hard disk.
The system is powered off.
Notes:
1. In the ThinkPad Configuration program, the computer can be set to suspend/hibernate
while docked.
2. The computer cannot enter hibernation mode when:
It is powered with ac power and a
communication PC Card is used.
General Descriptions 27
Related Service Information
The following events cause the computer to enter hibernation mode:
The Fn + F12 keys are pressed.The Hibernation button is selected in the Fuel-Gauge
program.
The power switch is turned off when hibernation
mode is set to Hibernate by Power Switch in the Windows 98 Power Management Properties window.
The timer conditions are satisfied in suspend mode
(for operating systems other than Windows 98).
A critically low battery condition occurs and
hibernation mode is set to Hibernate when battery becomes low.
The computer exits hibernation mode and resumes operation when the Power switch is pressed. When power is turned on, the hibernation file in the boot record on the hard disk drive is read and system status is restored from the hard disk drive.
28
Related Service Information

Fn Key Combinations

The following table shows the Fn key and function key combinations and their corresponding functions.
The Fn key works independently from the operating system. The operating system obtains the status through the system management interface to control the system.
Fn + Description F1 Reserved. F2 Turn Fuel-Gauge display on or off. F3 Turn standby mode on. F4 Turn suspend mode on. F5 Reserved. F6 Reserved. F7 Switch between the LCD and an external
F8 Turn screen expansion on or off. (no symbol
F9 Reserved. F10 Reserved. F11 Switch the power management mode
F12 Turn hibernation mode on. Model depending functions Pg Up Increase the sound volume or un-mute. Pg Dn Decrease the sound volume or un-mute. Back
space
monitor.
on the key)
(High Performance, Automatic, and Customized)
Note: In Windows 98, only the CPU speed
is changed.
Mute.
General Descriptions 29

Checkout Guide

Checkout Guide
Use the following procedure as a guide for computer problems.
Note: The diagnostic tests are intended to test only IBM
products. Non-IBM products, prototype cards, or modified options can give false errors and invalid system responses.
1. Obtain the failing symptoms in as much detail as possible.
2. Verify the symptoms by attempting to re-create the failure by running the diagnostic test or by repeating the same operation.
Note: To run the diagnostics, refer to “Running the
Diagnostics” on page 39.
3. Use the following table with the verified symptom to determine which page to go to. Search the “Symptoms (Verified)” column, and find the description that best matches your symptom; then go to the page shown in the “Go To” column.
Symptoms (Verified) Go To
Power failure. (The power indicator does not go on or stay on.)
POST does not complete. No beep or error codes are indicated.
POST beeps, but no error codes are displayed.
POST detected an error and displayed numeric error codes.
The diagnostic test detected an error and displayed a FRU code.
The configuration is not the same as the installed devices.
Other symptoms (such as LCD display problems).
“Power Systems Checkout” on page 35.
“Symptom-to-FRU Index” section, and then use the No Beep Symptoms table.
“Symptom-to-FRU Index” section, and then use the Beep Symptoms table.
“Symptom-to-FRU Index” section, and then use the Numeric Error Codes table.
“FRU Codes” on page 44.
“Checking the Installed Devices List” on page 42.
“Symptom-to-FRU Index” section, and then use the Other
Symptoms table.
30
Checkout Guide
Symptoms (Verified) Go To
Symptoms cannot be re-created (intermittent problems).
Use the customer-reported symptoms and go to “Symptom-to-FRU Index” section.

Audio Checkout

ISA Audio Check Out
1. Go to the diagnostic menu by selecting Test in the Easy-Setup menu.
2. Select Audio and run the diagnostic tests.
3. If the test detects a audio problem, replace the system board.
PCI Audio Check Out
1. Power off the computer.
2. Insert the ThinkPad Hardware Maintenance Diskette Version 1.05 or later version into the diskette drive.
3. Power on the computer.
4. Select Test the audio feature from the main menu.
5. If FAIL is displayed on the screen, replace the system board.

Diskette Drive Checkout

Do the following to isolate the problem to a controller, drive, or diskette. A blank, formatted, write-enabled, nondefective 2HD diskette is required.
FDD-1
represents the diskette drive in the bay.
represents an external diskette drive. Note: Some ThinkPad 600E computers support only one
FDD at a time. The icon of the diskette drive for such models is FDD instead of FDD-1 or FDD-2.
Attention: Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause damage to the drive or cause the drive to fail.
Do the following to select the test device. See “Running the Diagnostics” on page 39 for details.
1. Start Easy-Setup.
2. Click on Test.
3. Press Ctrl+A to enter the advanced diagnostic mode. The ThinkPad FRU Connections window appears.
4. Click on Exit. The keyboard layout window appears.
5. Click on Exit.
6. Click on FDD-1 (or FDD-2) to start the test.
FDD-2
General Descriptions
31
Checkout Guide
7. Insert the blank diskette when instructed and follow the instructions on the screen.
8. If the controller test detects an error, FRU code 10 appears. Replace the system board.
9. If the controller test runs without errors, the drive read/write tests start automatically. If a drive test detects an error, FRU code 50 for FDD-1 or 51 for FDD-2 appears. If the diskette itself is known to be good, replace the drive.

Fan Checkout

To check the fan, do the following:
1. Start Easy-Setup.
2. Click on Test. The fan will start so you can check the air turbulence at the louver near the power switch.
3. Press Ctrl+A to enter the advanced diagnostic mode. The ThinkPad FRU Connections window appears. If the fan connector is not connected, Fan not connected message appears.
4. Click on Exit. The keyboard layout window appears.
5. Click on Exit.
6. Click on System Board and press Enter to run the test. Follow the description on the window. If the test detects the fan problem, replace it.

Indicator LED Checkout

If an indicator LED problem occurs, do the following:
1. Power off the computer.
2. Power on the computer. All the LEDs should turn on for a moment after the computer is powered on.
3. Verify that all LEDs turned on. If some of the LEDs do not turn on, replace the card that the LEDs are on. If the problem persists, replace the system board.

Indicator Panel Check Out

If an indicator panel problem occurs, do the following:
1. Power off the computer.
2. Power on the computer. All the icons should turn on for a moment after the computer is powered on.
3. Verify that all icons appear correctly. If some of the icons do not appear, replace the card that the indicator panel is connected to. If the problem persists, replace the DC-DC card.

Keyboard or Auxiliary Input Device Checkout

Remove the external keyboard if the internal keyboard is to be tested.
If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable extending from the keyboard is correctly seated in the connector. If the keyboard cable connection is correct, run
32
Checkout Guide
the keyboard test. See “Running the Diagnostics” on page 39 for details.
Note: When the Fn key is pressed, a black square briefly
appears.
If the tests detect a keyboard problem, do the following one at a time to correct the problem. Do not replace a nondefective FRU:
1. Reseat the keyboard cable.
2. Replace the keyboard.
3. Replace the card that the keyboard is connected to.
4. Replace the system board.
The following auxiliary input devices are supported for this computer:
Numeric keypad
Mouse (PS/2 compatible)External keyboard (with keyboard/mouse cable)
If any of these devices do not work, reseat the cable connector and repeat the failing operation.
If the problem does not recur, recheck the connector. If the problem is not corrected, replace the device and then the card that the devices are directly connected to.

Memory Checkout

DIMM cards are available for increasing memory capacity. The memory size is displayed in kilobites. 576 KB is
reserved by the system, so you calculate the memory size by the following equation: [total memory size (MB)] × 1024 576 (KB)
For example, if the total memory size is 64 MB, it is displayed as 64960 KB.
Memory errors might stop system operations, show error messages on the screen, or hang the system.
Use the following procedure to isolate memory problems:
1. Power off the computer and remove any installed DIMM from its slot.
Note: If the computer has a base memory slot and
option memory slots, remove any DIMMs installed in the option memory slots.
2. Press and hold the F1 key; then power on the computer. Hold the F1 key down until the Easy-Setup menu appears.
3. Select Test and press Enter.
4. Select Memory and press Enter to run the memory test on base memory.
See “Running the Diagnostics” on page 39 for details.
General Descriptions
33
Checkout Guide
If an error appears:
If the computer don't have the base memory slot,
replace the system board.
If the computer has the base memory slot,
remove the DIMM installed in the base memory slot and go to step 2 on page 33. Then if an error appears, replace the system board.
If an error does not appear, continue the following procedures.
5. Power off the computer and reinstall the DIMM one by one; then power on the computer. Verify the memory size; then test the memory. If an error appears, replace the DIMM.
Note: Make sure that the DIMM is fully installed into
the connector. A loose connection can cause an error.
6. If the problem does not corrected, replace the following FRU. a. System board b. CPU card
If memory problems occur intermittently, use the loop option to repeat the test. When the test detects an error, an error log is printed on the printer connected to the parallel port. See “Displaying the Error Log” on page 42 for more information.
System Programs in Flash Memory: System
setup programs and diagnostic tests are stored in the Flash memory.
Flash Memory Update: The Flash memory update
is required for the following conditions:
New versions of system programsNew features or options
To update the Flash memory, do the following:
1. Get the appropriate diskette containing the update.
2. Insert the System Program Service Diskette into drive A and power on the computer.
3. Select Update system programs from the menu.

Modem (DSP) Checkout

Note: This section is for the built-in modem model.
Do the following:
1. Go to the diagnostic menu by selecting Test in the Easy-Setup menu.
2. Select DSP and run the diagnostic tests.
3. If the test detects a DSP problem, replace the modem card.
34
Checkout Guide

Port Replicator Checkout

Use the following procedure to isolate a port replicator problem. The port replicator attaches to the system expansion connector at the rear of the computer:
1. Power off the computer.
2. Remove the failing devices from the port replicator.
3. Unplug the AC Adapter from the port replicator, if attached.
4. Remove the port replicator from the computer.
5. Reconnect the failing device directly to the computer. (If another device is already connected to the computer, remove it first.)
6. Go to the “Running the Diagnostics” on page 39 and run the diagnostics.
7. If the advanced diagnostic device test did not find an error, suspect a problem with the port replicator.
8. Power off the computer and reconnect the port replicator.
9. Power on the computer and run the following advanced diagnostic tests:
Serial port test with the wrap plug installed on
the port replicator
Universal serial bus test with the USB parallel
test cable
Parallel port test with the wrap plug installed on
the port replicator
FDD-2 device test on the failing device with a
scratch diskette
10. If diagnostic errors appear, replace the port replicator or the diskette drive. If the problem remains after the replacement, replace the system board.
11. If power problems appear only when the port replicator is used, replace the port replicator.
Port Replicator Power Overload: If power
shutdown occurs intermittently when PC Card devices are used through a port replicator with PC Card slots, suspect an over-current problem. Some PC Card devices use more power; if the maximum usage of each device occurs simultaneously, the total current will exceed the limit, thereby causing a power shutdown. Isolate this problem by removing one of the devices, use the computer under the same condition, and see whether a power shutdown occurs. Do this procedure for all devices to determine the cause.
Power Systems Checkout
To verify the symptom of the problem, power on the computer using each of the following power sources:
1. Remove the battery pack.
2. Connect the AC Adapter and check that power is supplied.
General Descriptions
35
Checkout Guide
3. Disconnect the AC Adapter and install the charged battery pack; then check that power is supplied by the battery pack.
If you suspect a power problem, see the appropriate power supply checkout in the following list:
“Checking the AC Adapter”“Checking Operational Charging”“Checking the Battery Pack” on page 37“Checking the Backup Battery” on page 38
Checking the AC Adapter: You are here
because the computer fails only when the AC Adapter is used:
If the power problem occurs only when the port
replicator is used, replace the port replicator.
If the power-on indicator does not turn on, check the
power cord of the AC Adapter for correct continuity and installation.
If the operational charge does not work, go to
Checking Operational Charging.
1. Unplug the AC Adapter cable from the computer and measure the output voltage at the plug of the AC Adapter cable. See the following figure:
(16 - 10 V)
Pin Voltage (V dc)
1 +15.5 to +17.0 2 Ground
If the voltage is not correct, replace the AC Adapter. If the voltage is within the range, do the following:
Replace the system board.If the problem is not corrected, go to
“Undetermined Problems” section of each model.
Note: An audible noise from the AC Adapter does not
always indicate a defect.
Checking Operational Charging: To check
operational charging, use a discharged battery pack or a battery pack that has less than 50% of the total power remaining when installed in the computer.
Perform operational charging. If the battery status indicator or icon does not turn on, remove the battery pack and let it return to room temperature. Reinstall the battery
36
Checkout Guide
pack. If the charge indicator or icon still does not turn on, replace the battery pack.
If the charge indicator still does not turn on, replace either the system board or DC-DC card that the battery is connected to. Then reinstall the battery pack. If the reinstalled battery pack is not charged, go to the next section.
Checking the Battery Pack: Battery charging will
not start until the Fuel-Gauge shows that less than 95% of the total power remains; with this condition the battery pack can charge to 100% of its capacity. This protects the battery pack from being overcharged or having a shortened life.
Do the following:
1. Power off the computer.
2. Remove the battery pack and measure the voltage between battery terminals 1 (+) and 4 (). See the following figure:
Terminal Voltage (V dc) 1 + 0 to + 12.6 4 Ground ()
3. If the voltage is less than +11.0 V dc, the battery pack has been discharged. Recharge the battery pack.
Note: In this case, the battery pack is
over-discharged. It takes at least 3 hours to recharge the battery pack even if the indicator does not turn on.
If the voltage is still less than +11.0 V dc after recharging, replace the battery.
4. If the voltage is more than +11.0 V dc, measure the resistance between battery terminals 3 and 4. The resistance must be 4 to 30 K ohm.
If the resistance is not correct, replace the battery pack. If the resistance is correct, replace the system board.
General Descriptions 37
Checkout Guide
Checking the Backup Battery: Do the following:
1. Power off the computer and unplug the AC Adapter from the computer.
2. Turn the computer upside down.
3. Remove the backup battery (see “Removal and Replacement” section of each model).
4. Measure the voltage of the backup battery. See the following figure.
Note: Be careful not to measure the wrong side of
the backup battery.
Wire Voltage (V dc)
Red +2.5 to +3.2 Black Ground
If the voltage is correct, replace the system board.If the voltage is not correct, replace the backup
battery.
If the backup battery discharges quickly after
replacement, replace the system board.

System Board and CPU Card Checkout

The processing functions are performed by both the system board and the CPU card. Processor problems can be caused by either FRU. However, the CPU card generally has a lower probability of failure. If a numeric code indicates the system board or the CPU card as a failing FRU, or the CPU card is indicated by a diagnostic test by showing FRU code 11, use the following procedure to isolate the problem:
1. Run the system board test to verify the symptom. This test verifies both the system board and the CPU card. If no error is detected, return to “Checkout Guide” on page 30.
Note: Don't touch the keyboard and pointing device
when the system board test is running. This might cause an unexpected error.
38

Running the Diagnostics

2. If FRU code 10 appears, replace the system board but do not replace the CPU card. Remove the CPU card from the old system board and install it to the new system board.
3. If FRU code 11 appears, reseat the CPU card.
4. Rerun the test to verify the fix.
5. If FRU code 11 remains, replace the CPU card.
If this procedure does not correct the problem, go to the “Undetermined Problems” section for each model.

TrackPoint Checkout

If the TrackPoint does not work, check the configuration in the ThinkPad Configuration program. If the configuration of the TrackPoint is disabled, select Enable to enable it.
If this does not correct the TrackPoint problem, continue with the following. After you use the TrackPoint, the pointer drifts on the screen for a short time. This self-acting pointer movement can occur when a slight, steady pressure is applied to the TrackPoint pointer. This symptom is not a hardware problem. No service actions are necessary if the pointer movement stops in a short period of time.
If a click button problem or the pointing stick problem occurs, do the following:
1. Go to the Easy-Setup menu.
2. Select an item with the pointing stick.
3. Press any one of the click buttons.
4. Verify that the item is selected.
5. Move to another item with the pointing stick.
6. Press the pointing stick (press-to-select), and verify that the item is selected.
Note: This step is only for the model that has the
press-to-select function.
7. Verify that all buttons work correctly.
If either the pointing stick or the click button do not work, do the following actions one at a time to correct the problem. Do not replace a nondefective FRU.
1. Reseat the keyboard cables.
2. Replace the keyboard.
3. Reseat the card that the TrackPoint cable is directly connected to.
4. Replace the system board.
Running the Diagnostics
The following table lists the special tools needed for the diagnostics:
General Descriptions 39
Running the Diagnostics
Tool Name Part Number
PC test card 35G4703 Tri-connector wrap plug 72X8546 USB parallel test cable 05K2580
Use either the TrackPoint or the cursor-moving keys to interact with the tests. The Enter key works the same as selecting the OK icon to reply OK.
1. Press and hold F1; then power on the computer. Hold F1 down until the Easy-Setup menu appears.
2. Click on Test. The basic diagnostic menu appears.
3. Click on a device to run the test. The test progress screen appears; then OK appears under the tested device icon when the test ends without any errors.
4. Start the Advanced Diagnostic test by pressing Ctrl+A on the basic diagnostic menu. The ThinkPad FRU connections window appears.
5. Click on Exit or press the Esc key. The keyboard test window appears.
6. When you press a key, a mark appears or disappears on the corresponding key position on the screen. Repeat this step for any keys that need to be tested. You can run the keyboard test if you press Ctrl+K in the advanced diagnostic test mode.
7. To exit the keyboard test, click on Exit or press Ctrl+Break. The advanced diagnostics window appears.
8. Click on a device to test it, or click on Test All to test all devices.
Click on Looptest to run the tests in a repeated loop. The loop option menu appears. Click on a device; the mark appears beside the selected device. Repeat this step to select multiple devices. Click on OK to start the diagnostic loop. If no device is selected, all devices tests are looped.
9. To exit the loop, keep pressing Ctrl+Pause until the test exits. A beep sounds to notify that the exit interrupt is sensed by the test program. Press Esc to exit from the loop test.
40
Running the Diagnostics

PC Card Slots Test

The green LED on the PC test card turns on when the PC Card slot test is running. If the LED does not turn on, check that the card is installed correctly by reseating it. If the LED still does not turn on after the card is reseated, try using another slot for the test. If the LED still does not turn on and the test fails, replace the FRU shown by the diagnostic error code.

Universal Serial Bus (USB) Test

At the advanced diagnostic window, do the following:
1. Connect the USB parallel test cable to the parallel connector of the computer.
2. Connect Connector 1 of the cable to the USB connector of the computer.
Note: The illustration shows a ThinkPad 770
computer, but the procedure is the same for the other model.
3. Click on USB-1 to run the test. Follow the instructions on the screen. OK appears if
the test passed, but three lines of error codes appear if the test failed. The defective FRU must be the system board.
If you want to test the USB port on the port replicator, connect the USB parallel test cable to a port replicator and click on USB-2.
If you want to test the USB ports on a docking station, connect the USB parallel test cable to the
General Descriptions
41
Running the Diagnostics
USB ports of the docking station and click on USB-3 and USB-4.

Displaying the Error Log

Diagnostic errors are printed on a printer attached to the parallel port when the error is detected. The error is also logged in the system memory.
Use the following procedure to display the errors:
1. Enter the advanced diagnostic test.
2. Press Ctrl+E.
3. The error log appears.
4. To exit the screen, click on Exit or press Esc.
The error log is not saved when system power is turned off.

Checking the Installed Devices List

If a device is installed but the icon appears in a gray shade rather than a dark shade on the basic diagnostics menu, the device is defective. If necessary, adjust the contrast control to clearly distinguish the shades of the icon. Reseat the device connectors. If the symptom remains, replace the device or the system board.
If a device that is not installed appears in a dark shade (for
no
example, FDD-2 appears in a dark shade when FDD is installed), do the following:
Note: Some ThinkPad 600E computers support only one
FDD at a time. The icon of the diskette drive for such models is FDD instead of FDD-1 or FDD-2.
1. Replace the first device in the configuration, such as an FDD-1.
2. If the problem persists, replace the card that the device is connected to.
The Parallel, and Serial icons are always displayed in a dark shade, because the icons represent subsystems of the system board and not the attachment of devices.
The FDD-1 icon represents a device in the computer. The FDD-2 icon represents another device, such as:
An external diskette drive attached to the computerAn external diskette drive attached to a port replicatorA diskette drive in a docking station
second

Diagnostic Error Codes

If an error is detected, the following appears:
Large X on the left side of the device icon.Device ID (three digits).Error code (two digits).FRU code (four digits).
42
Running the Diagnostics
The device ID and error code indicate the detailed portion of the FRU that caused the error. If replacing a FRU does not correct the problem, see the device ID or error code from the previous failure. If they have changed, the cause might be that the new FRU is defective or that the FRU was incorrectly installed.
Device ID: If an error is detected by the diagnostic
tests, a three-digit device ID is displayed, indicating the suspected device.
Icon Device ID Suspected Device SystemBoard 001 System board
003 Keyboard 007 Math coprocessor 086 Pointing device
Memory 002 Memory FDD-1 or
*
FDD FDD-2 or
*
FDD Parallel 009 Parallel port Serial 011 Serial port HDD-1 017 Hard disk drive HDD-2 151 First (external) hard disk
HDD-3 067 Second (external) hard
HDD-4 152 Third (external) hard disk
Display 050 Display
PCMCIA-1 080 1. Connection of the
PCMCIA-2 088 External PC Card Infrared 103 IR DSP 113 DSP Audio (ISA) 153 ISA audio
006 Diskette drive in the
computer
066 External diskette drive
or FDD connector
drive
disk drive
drive
052 053 054
PC Card slot
2. PC Card
General Descriptions 43
Running the Diagnostics
Icon Device ID Suspected Device USB-1 154 USB USB-2 155 External USB USB-3 156 External USB USB-4 157 External USB Audio (PCI) 158 PCI audio CDROM-1 215 CD-ROM CDROM-2 216 External CD-ROM DVD-1 217 DVD drive DVD-2 218 External DVD drive Note:
* Some ThinkPad 600E computers support only one FDD at
a time. The icon of the diskette drive for such models is FDD instead of FDD-1 or FDD-2.
FRU Codes: If an error is detected by the diagnostic
tests, a four-digit FRU code is displayed. The FRU code indicates two suspected FRUs. Replace the FRU that is indicated by the FRU that indicated by the is assigned to code 00. If only one FRU is suspected, the other FRU code is 00. See the reference page before replacing the FRU.
FRU Code FRU
10 System board 11 CPU card 12 DC-DC card 15 Audio card 16 Modem card 20 Memory 30 Reserved 32 External keyboard 33 External mouse 34 AC Adapter 35 Stereo Speaker 36 Battery pack 37 Secondary battery pack 38 Fan 39 Box speaker 40 LCD assembly 41 DVD or DVD and enhanced video adapter 42 Video card or system board (video) 45 External monitor
two leftmost digits
two rightmost digits.
first; then replace the
No FRU
44
Running the Diagnostics
FRU Code FRU
50 1. Reseat the diskette drive (FDD-1)
51 1. Reseat the diskette drive (FDD-2)
60 1. Reseat the hard disk drive (HDD-1)
61 1. Reseat the hard disk drive in the
62 1. Reseat the hard disk drive in the
63 1. Reseat the hard disk drive in the
70 PC Card (at the port replicator) 72 PC Card slot assembly 73 Port replicator 74 Main board in the docking station 75 USB card in the docking station 90 CD-ROM drive 91 External CD-ROM drive 92 DVD drive 93 External DVD drive
2. Diskette drive (FDD-1)
2. Diskette drive (FDD-2)
2. Hard disk drive (HDD-1)
docking station (HDD-3)
2. Hard disk drive in the docking station (HDD-3)
docking station (HDD-2)
2. Hard disk drive in the docking station (HDD-2)
docking station (HDD-4)
2. Hard disk drive in the docking station (HDD-4)
If the problem persists after replacement of the FRUs, go to the “Undetermined Problems” section for each model.
General Descriptions 45
Running the Diagnostics
46
Running the Diagnostics
ThinkPad 600
This chapter includes the descriptions for the ThinkPad 600 series computer.
Model-Unique Functions . . . . . . . . . . . . . . 49
Product Overview . . . . . . . . . . . . . . . 49
Status Indicators . . . . . . . . . . . . . . . . 51
Symptom-to-FRU Index . . . . . . . . . . . . . . 52
Numeric Error Codes .............. 52
Beep Symptoms . . . . . . . . . . . . . . . . 57
Audio-Related Symptoms . . . . . . . . . . . 58
CD-ROM-Related Symptoms . . . . . . . . . . 58
Function-Related Symptoms . . . . . . . . . . 60
Indicator-Related Symptoms . . . . . . . . . . 60
Infrared-Related Symptoms . . . . . . . . . . . 61
Keyboard- or TrackPoint-Related Symptoms . . . 61
LCD-Related Symptoms . . . . . . . . . . . . 62
Modem (DSP)-Related Symptoms ....... 62
PC Card-Related Symptoms .......... 63
Peripheral-Device-Related Symptoms . . . . . . 63
Power-Related Symptoms . . . . . . . . . . . 64
Other Symptoms . . . . . . . . . . . . . . . . 64
Intermittent Problems . . . . . . . . . . . . . 64
Undetermined Problems . . . . . . . . . . . . 64
FRU Removals and Replacements ......... 66
1010 Backup Battery . . . . . . . . . . . . . 67
1020 DIMM . . . . . . . . . . . . . . . . . . 68
1030 Battery Pack . . . . . . . . . . . . . . 69
1040 Hard Disk Drive ............. 70
1050 UltraslimBay Device . . . . . . . . . . . 71
1060 Keyboard Assembly . . . . . . . . . . . 72
1070 Keyboard . . . . . . . . . . . . . . . . 74
1080 Speakers . . . . . . . . . . . . . . . . 75
1085 Speaker Cable . . . . . . . . . . . . . 77
1090 LCD Assembly . . . . . . . . . . . . . 78
1100 PC Card (PCMCIA) Slot Assembly .... 79
1110 Modem Card . . . . . . . . . . . . . . 80
1115 System Kit for RFID ........... 81
1120 Sub Card . . . . . . . . . . . . . . . . 81
1130 CPU Card and Fan ........... 83
1140 Guide Rail, Mic. Cable, or TV Out Card . . 85
1150 System Board . . . . . . . . . . . . . . 87
2010 LCD Front Cover ............ 88
2020 LCD Hinges and Cables ......... 91
2030 Inverter Card . . . . . . . . . . . . . . 96
Locations . . . . . . . . . . . . . . . . . . . . . 99
Front View . . . . . . . . . . . . . . . . . . 99
Bottom View . . . . . . . . . . . . . . . . . 100
Password Pads . . . . . . . . . . . . . . . 100
Rear View . . . . . . . . . . . . . . . . . . 101
Parts List . . . . . . . . . . . . . . . . . . . . 102
Copyright IBM Corp. 1999 47
Running the Diagnostics
Model 600 . . . . . . . . . . . . . . . . . . 102
LCD FRU (TFT) ............... 105
Model 600E . . . . . . . . . . . . . . . . . 108
LCD FRU (TFT) ............... 111
Keyboard . . . . . . . . . . . . . . . . . . 112
Miscellaneous Parts . . . . . . . . . . . . . 112
Modem Kit . . . . . . . . . . . . . . . . . 114
Common Parts List ............. 115
48

Model-Unique Functions

Model-Unique Functions Product Overview
The following table is an overview of the system features of the ThinkPad 600 series:
Feature Description Processor For 600:
Intel Pentium MMX 233 MHz,
L2 cache
Intel Pentium II 233 MHz, L2
cache
Intel Pentium II 266 MHz, L2
cache
Intel Pentium II 300 MHz, L2
cache
For 600E:
Intel Pentium II 300 MHz, L2
cache with AGP
Intel Mobile Pentium II 300PE
MHz, L2 cache with AGP
Intel Mobile Pentium II 366 MHz,
L2 cache with AGP
Intel Mobile Pentium II 400 MHz,
L2 cache with AGP
Bus Architecture For 600:
PCI Bus
For 600E:
PCI Bus, AGP Bus
Memory (Standard)
Memory (Option) For 600:
CMOS RAM 114 bytes +4 Kbytes
For 600:
32 MB (on the system board)32 MB (on the system board) and
32 MB in the DIMM slot
For 600E:
32 MB (on the system board)32 MB (on the system board) and
32 MB in the DIMM slot
16 MB, 32 MB, 64 MB, or 128 MB
DIMM card (maximum of 288 MB)
For 600E:
32 MB, 64 MB, or 128 MB DIMM
card (maximum of 288 MB)
ThinkPad 600 49
Model-Unique Functions
Feature Description Video For 600:
13.0-inch, 64K colors 1024×768
pixel HPA color LCD
12.1-inch, 64K colors, 800×600
pixel TFT color LCD
13.3-inch, 64K colors, 1024×768
pixel TFT color LCD
For 600E:
13.3-inch, 16M colors 1024×768
pixel TFT color LCD
Diskette Drive (External)
Hard Disk Drive For 600:
CD-ROM/DVD Drive
I/O Port External monitor
Internal Modem For 600:
Audio 16-bit audio
Infrared Transfer IrDA 1.1 PCMCIA One Type-III or two Type-II AC Adapter 56-Watt type
1.44 MB (3-mode), 3.5-inch
3.2 GB, 2.5-inch, IDE interface4.0 GB, 2.5-inch, IDE interface
For 600E:
4.0 GB, 2.5-inch, IDE interface6.4 GB, 2.5-inch, IDE interface10.0 GB, 2.5-inch, IDE interface
For 600:
24 x CD-ROM drive (some models
have no CD-ROM)
For 600E:
24 x CD-ROM driveDVD drive (2 x DVD)
Headphone Microphone Mouse Parallel Port replicator Serial USB
Video output port (for 600E only)
56.6 Kbps (some models have no
internal modem.)
For 600E:
56.6 Kbps
Internal stereo speaker
Internal microphone
Software control volume
50
Model-Unique Functions

Status Indicators

The system status indicators show the current computer status in different colors (green and orange):
Symbol Color Meaning
.1/Battery Green The battery is fully charged.
Orange The battery is charging. Blinking
orange
.2/Suspend Mode
.3/Hard Disk In Use
.4/Numeric Lock
.5/Caps Lock
.6/Scroll Lock
.7/Power On Green Power on
Green Suspend mode Blinking
green Orange Data is read from or written
Green The numeric keypad on the
Green Caps Lock mode is enabled.
Green Arrow keys can be used as
The battery needs charging.
Entering suspend mode
to the hard disk drive.
keyboard is enabled.
screen-scroll function keys.
ThinkPad 600 51

Symptom-to-FRU Index

Symptom-to-FRU Index
The symptom-to-FRU index lists the symptoms and errors and their possible causes. The most likely cause is listed first.
Note: Perform the FRU replacement or actions in the
sequence shown in the “FRU/Action in Sequence” column. If a FRU replacement did not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.
This index can also help you determine the next possible FRUs to be replaced when servicing a computer.
Numeric error codes show the errors detected in POST or system operation. In the following error codes, X can be any number.
If no codes are available, use narrative symptoms. If the symptom is not listed, go to “Undetermined
Problems” on page 64.
Note: For IBM devices not supported by diagnostic
codes in the ThinkPad notebook computers, see the manual for that device.

Numeric Error Codes

Symptom / Error FRU / Action in Sequence 10X
101: Interrupt failure. 102: Timer failure. 103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not accepted. 107: NMI test failure. 108: Timer bus test failure.
109: Low meg-chip
select test.
110
(Planar parity.)
52
1. System board
1. Go to “Memory
Checkout” on page 33.
2. DIMM card
3. Detach the expansion unit if it is attached to the computer.
4. System board
Symptom-to-FRU Index
Symptom / Error FRU / Action in Sequence 111
(I/O parity.)
11XX
1101: Serial_A test failure.
12XX
1201: Serial_B test failure.
158
(The hard disk password was not set even though the supervisor password is set.)
159
(The hard disk password is not set the same as the supervisor password.)
161
(Dead battery.)
163
(Time and date were not set.)
173
(Configuration data was lost.)
174
(Configuration error: Perform“Checking the Installed Devices List” on page 42 before changing any FRUs.)
175, 177, 178
175: EEPROM CRC
#1 error.
177: Supervisor
password check sum error. 178: EEPROM is not functional.
17XX
1701: Hard disk
controller failure.
1780, 1790: Hard disk
0 error.
1781, 1791: Hard disk
1 error.
1. Go to “Memory
Checkout” on page 33.
2. Expansion unit or port replicator.
3. System board
1. Serial device
2. Communication cable
3. System board
1. System board
(infrared)
Set the password for the hard disk drive.
Set the correct password for the hard disk drive.
1. Go to “Checking the Backup Battery” on page 38.
2. Backup battery
3. System board
1. Set time and date.
2. System board
1. Select OK in the error
screen; then set the time and date.
2. Backup battery
3. System board
1. Check device
configuration.
2. Hard disk drive assembly
3. System board
1. System board
1. Hard disk drive
2. System board
ThinkPad 600 53
Symptom-to-FRU Index
Symptom / Error FRU / Action in Sequence 183
(Incorrect password entered at the supervisor password prompt.)
184
(Power-on password check sum error.)
185
(The startup sequence is not valid. Suspect that power was off when the startup sequence was being updated.)
186 1. System board 188, 189
(BAD EEPROM CRC #1. An incorrect checksum of the EEPROM is received.)
190
(A depleted battery pack was installed when the power was on.)
191XX
(PM initialization error.)
192
(Fan error.)
193
(RF Antenna has been removed.)
194
(The computer is carried through the portal gate.)
195
(The configuration read from the hibernation area does not match the actual configuration.)
196
(A read error occurred in the hibernation area of the hard disk drive.)
199XX
(Resume error.)
Have the user examine the password.
Reset the power-on password in Easy-Setup.
Reset the startup sequence in Easy-Setup.
1. System board
Go to “Checking the Battery Pack” on page 37.
1. System board
1. Measure the voltage
of the backup battery. If the voltage is not correct, replace the backup battery.
2. Fan
3. System board
1. Type the correct
Supervisor Password at the password prompt.
2. Reseat the RF Antenna to the HDD cover.
1. Type the correct
Supervisor Password at the password prompt.
Check if the configuration was changed.
For example, check if the DIMM card is added.
1. Run the hard disk
drive test.
2. Hard disk drive
1. System board
54
Symptom-to-FRU Index
Symptom / Error FRU / Action in Sequence 1XX 1. System board 2XX
201: Memory data
error. 202: Memory line error 00–15. 203: Memory line error 16–23.
205: Memory test
failure on on-board memory. 221: ROM to RAM remap error.
225
(Unsupported memory module.)
301, 303, 304, 305, 3XX
(301: Keyboard error.)
601, 6XX
(601: Diskette drive or controller error.)
602
(Diskette read error.)
604
(Unacceptable ID was read from the diskette drive.)
2402 1. TV Out Card 24XX
(2401: System board video error.)
1. Go to “Memory
Checkout” on page 33.
2. DIMM card
3. System board
1. Check if the
supported DIMM is installed.
2. DIMM card
3. System board
1. Go to “Keyboard or
Auxiliary Input Device Checkout” on page 32.
2. Keyboard
3. External numeric keypad
4. External keyboard
5. Keyboard/mouse cable
6. System board
1. Go to “Diskette Drive
Checkout” on page 31.
2. Diskette drive assembly
3. Diskette
4. System board
1. Go to “Diskette Drive
Checkout” on page 31.
2. Diskette
3. Diskette drive assembly
1. Go to “Diskette Drive
Checkout” on page 31.
2. Diskette drive assembly
3. System board
1. System board
ThinkPad 600 55
Symptom-to-FRU Index
Symptom / Error FRU / Action in Sequence 808X
8081: PCMCIA
presence test failure. (PCMCIA revision number also checked.)
8082: PCMCIA register
test failure.
860X
(Pointing device error when TrackPoint is disabled.)
8601: System bus
error–8042 mouse interface.
8602: External mouse
error.
8603: System bus
error or mouse error.
861X
(Pointing device error when TrackPoint is enabled.)
8611: System bus
error–I/F between 8042 and IPDC.
8612: TrackPoint error.
8613: System board or TrackPoint error.
I9990301 I9990302 I9990305
I9990301: Hard disk
error.
I9990302: Invalid hard
disk boot record.
I9990305: No bootable
device.
I9990303
(Bank–2 flash ROM check sum error.)
Other codes not listed above.
1. PC Card slot
assembly
2. PCMCIA device
3. System board
1. External mouse
2. External keyboard
3. System board
1. Reseat the keyboard
cable on the sub card.
2. Keyboard
3. External mouse
4. Sub card
5. System board
1. Check that the
operating system is installed in the hard disk drive. If not, install the operating system.
2. Reseat the boot device.
3. Check the startup sequence for the correct boot device.
4. Check that the operating system has no failure and is installed correctly.
1. System board
Go to “Undetermined Problems” on page 64.
56
Symptom-to-FRU Index

Beep Symptoms

Symptom / Error FRU / Action in Sequence
Continuous beeps. 1. System board One beep and a blank,
unreadable, or flashing LCD.
One beep, and the message “Unable to access boot source.”
One long and two short beeps, and a blank or unreadable LCD.
One long beep followed by four short beeps each time the power switch is operated. (System cannot power on due to low battery voltage.)
One beep every second. (System is shutting down due to low battery voltage.)
Two short beeps with error codes.
Two short beeps with blank screen.
1. Reseat the LCD
connector
2. LCD assembly
3. System board
1. Boot device
2. System board
1. System board
2. LCD assembly
Connect the AC Adapter or install a fully charged battery.
Connect the AC Adapter or install a fully charged battery. (Allow the system to completely shut down before changing the battery.)
POST error. See “Numeric Error Codes” on page 52.
1. System board

No Beep Symptoms

Symptom / Error FRU / Action in Sequence
No beep, power-on indicator not on, and a blank LCD during POST.
No beep, power-on indicator on, and a blank LCD during POST.
No beep, power-on indicator on, and a blinking cursor only during POST.
No beep during POST but system runs correctly.
ThinkPad 600 57
1. Go to “Power
Systems Checkout” on page 35.
2. System board
3. Check the power outlet
1. System board
1. System board
1. Turn the volume up and check the speaker.
2. Speaker
3. Sub card
4. System board
Symptom-to-FRU Index

Audio-Related Symptoms

Symptom / Error FRU / Action in Sequence
In OS/2, DOS, or Windows multimedia programs, no sound comes from the computer. (Only system beeps are heard at power-on.)
Check that the device driver is installed correctly.

CD-ROM-Related Symptoms

Symptom / Error FRU / Action in Sequence
You hear a noise from the CD-ROM drive when the CD-ROM is spinning.
The CD-ROM tray does not open even if you press the CD-ROM eject button.
The compact disc cannot be read.
1. CD-ROM drive
2. System board
Insert a pin into the CD-ROM emergency eject hole and eject the CD-ROM tray.
Make sure that:
The compact disc is
not dirty. If it is, clean it with a CD-ROM cleaner kit.
The compact disc is
not defective. If it is, try another compact disc.
The compact disc is
placed in the tray with the label side up.
The compact disc
format conforms with one of the following: – Music CD – CD-ROM or
CD-ROM XA
– Multisession
photo CD
– Video CD and
CD-i movie (Windows 95 does not support CD-i movies)
1. CD-ROM drive
2. System board
58
Symptom-to-FRU Index
Symptom / Error FRU / Action in Sequence
The CD-ROM does not work.
Make sure that:
The computer power is
turned on and a compact disc is in the CD-ROM drive.
The CD-ROM drive
connector is firmly connected to the computer.
The CD-ROM drive
tray is firmly closed.
The device drivers are
correctly installed.
If the CD-ROM drive in the docking station does not work, do the following:
1. Click on Start.
2. Move the cursor to
Programs and ThinkPad; then click on ThinkPad Configuration.
3. Click on Docking Station.
4. Make sure that you checked Enable IDE
device in the docking station.
Note: Do not use IRQ
11 and 15 for the PCI device setting.
5. Click on OK. If the problem remains, replace the following FRUs in order.
1. CD-ROM drive
2. System board
ThinkPad 600 59
Symptom-to-FRU Index

Function-Related Symptoms

Symptom / Error FRU / Action in Sequence
The system does not suspend or resume when the LCD is closed or opened.
The battery Fuel-Gauge does not go higher than 90%.
The memory count (size) appears different from the actual size.
The system configuration does not match the installed devices.
The system hangs intermittently.
1. Go to “Suspend
Mode” on page 26, and check that the computer can enter suspend mode.
2. Boot an operating system and press Fn+F4. If the computer enters suspend mode, suspect that the application program is not working properly.
3. LCD assembly
4. System board
Go to “Checking the Battery Pack” on page 37 and see the note.
Go to “Memory Checkout” on page 33.
Go to “Checking the Installed Devices List” on page 42.
Go to “Intermittent Problems” on page 64.

Indicator-Related Symptoms

Symptom / Error FRU / Action in Sequence
The indicator incorrectly remains off or on, but system runs correctly.
The battery power status indicator blinks from green, yellow, to orange.
The battery indicator does not turn on when the battery is installed.
60
1. Sub card
2. System board
1. Check that a correct
battery is installed.
2. Battery pack
3. System board
1. Battery pack
2. System board
Symptom-to-FRU Index

Infrared-Related Symptoms

Symptom / Error FRU / Action in Sequence
Unable to communicate using the Infrared (IR) Port.
1. Make sure the setup
for the IR is correct.
Use the ThinkPad Configurations utility.
2. Make sure there are no fluorescent lights near the computer. The computer may receive optical noise from the fluorescent light.
3. Run the advanced diagnostic test. If an error occurs and a FRU code is displayed, replace the parts shown by the FRU code.

Keyboard- or TrackPoint-Related Symptoms

Symptom / Error FRU / Action in Sequence
The keyboard (one or more keys) does not work.
The TrackPoint does not work.
The pointer moves automatically or does not work correctly.
1. Reseat the keyboard
cable on the sub card.
2. Keyboard
3. System board
1. Reseat the keyboard
cable on the system board.
2. Go to “TrackPoint Checkout” on page 39.
3. Keyboard
4. System board
See “TrackPoint Checkout” on page 39.
ThinkPad 600 61
Symptom-to-FRU Index

LCD-Related Symptoms

Important
The TFT LCD for the notebook computer contains over 2,359,296 thin-film transistors (TFTs). A small number of missing, discolored, or lighted dots (on all the time) is characteristic of TFT LCD technology, but excessive pixel problems can cause viewing concerns. The LCD should be replaced if the number of missing, discolored, or lighted dots in any background is 21 or
more.
Symptom / Error FRU / Action in Sequence
No beep, power-on indicator on, and a blank LCD during POST.
LCD backlight not
working.
LCD too dark.LCD brightness cannot
be adjusted.
LCD contrast cannot
be adjusted.
LCD screen
unreadable.
Characters missing
pels.
Screen abnormal.
Wrong color displayed.
LCD has extra horizontal or vertical lines displayed.
1. System board
1. Reseat the LCD
connectors.
2. LCD assembly
3. System board
1. See important note
for “LCD-Related Symptoms.”
2. Reseat all LCD connectors.
3. LCD assembly
4. System board
1. LCD assembly

Modem (DSP)-Related Symptoms

Symptom / Error FRU / Action in Sequence
In OS/2, DOS, or Windows multimedia programs, no sound comes from the computer. (Only system beeps are heard at power-on.)
In OS/2, DOS, or Windows, the modem does not work.
62
Check that the device driver is installed correctly.
Check that the DSP Modem is active.
OS/2 and Windows:
Click on the DSP Modem icon in the ThinkPad Configuration program.
DOS:
Run the MWMODEM ON command.
Symptom-to-FRU Index

PC Card-Related Symptoms

Symptom / Error FRU / Action in Sequence
PC Card does not work in either the upper slot or the lower slot.
Diagnostic error code: DEV 080
ERR 33 FRU 7210
PCMCIA slot pin is damaged.
PC Card does not work. 1. Reseat the PC Card
1. Reseat the PCMCIA slot assembly.
2. PCMCIA slot assembly
3. System board
PCMCIA slot assembly
2. Check that the PC Card is enabled in the ThinkPad Configuration program
3. Reseat the PCMCIA slot assembly.
4. PCMCIA slot assembly
5. System board

Peripheral-Device-Related Symptoms

Symptom / Error FRU / Action in Sequence
The external monitor does not work correctly.
Printer problems. 1. Run printer self-test.
Serial or parallel port device problems.
Connect the external monitor to another PC. If the monitor works fine, replace the system board. If not, replace the external monitor.
2. Run parallel port wrap test.
3. System board
4. Printer cable
1. Run serial/parallel port wrap test.
2. Device
3. System board
4. Device cable
ThinkPad 600 63
Symptom-to-FRU Index

Power-Related Symptoms

Symptom / Error FRU / Action in Sequence
Power shuts down during operation.
The system does not power off. (See “Reset Switch” on page 23.)
1. Go to “Power
Systems Checkout” on page 35.
2. Battery pack
3. Remove the battery pack and let it cool for 2 hours.
4. System board
5. Check the power outlet.
1. Press the power
shutdown switch.
2. System board

Other Symptoms

Symptom / Error FRU / Action in Sequence
Errors occur only when the port replicator is used.
PC Card slot pin is damaged.
Note
If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined Problems”
See “Port Replicator Checkout” on page 35.
1. PC Card slots assembly

Intermittent Problems

Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1. Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by the FRU code. Rerun the test to verify that no more errors exist.

Undetermined Problems

You are here because the diagnostic tests did not identify which adapter or device failed, installed devices are incorrect, a short circuit is suspected, or the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate nondefective FRUs).
64
Symptom-to-FRU Index
Verify that all attached devices are supported by the computer.
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power Systems Checkout” on page 35):
1. Power off the computer.
2. Visually check them for damage. If any problems are found, replace the FRU.
3. Remove or disconnect all of the following devices: a. Non-IBM devices
b. Devices attached to the port replicator
c. Printer, mouse, and other external devices
d. Battery pack
e. Hard disk drive
f. External diskette drive
g. DIMM
h. CD-ROM and diskette drive in the UltraslimBay
i. PC Cards
4. Power on the computer.
5. Determine if the problem has changed.
6. If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7. If the problem remains, replace the following FRUs one at a time. Do not replace a nondefective FRU: a. System board b. LCD assembly c. CPU card
ThinkPad 600 65

FRU Removals and Replacements

FRU Removals and Replacements
This section contains information about removals and replacements:
Do not damage any part. Only certified and trained
personnel should service the computer.
The arrows in the “Removals and Replacements”
section show the direction of movement to remove a FRU, or to turn a screw to release the FRU. The arrows are marked in numeric order, in square callouts, to show the correct sequence of removal.
If other FRUs must be removed before the failing
FRU is removed, they are listed at the top of the page.
To replace a FRU, reverse the removal procedure
and follow any notes that pertain to replacement. See “Locations” for internal cable connections and arrangement information.
When replacing a FRU, use the correct screw as
shown in the procedures.
Reviews “FRU Replacement Notices” on page 19 before replacing any FRU.
Caution
Before removing any FRU, power off the computer, unplug all power cords from electrical outlets, remove the battery pack, and then disconnect any interconnecting cables.
Caution
The battery pack contains small amounts of nickel. Do not disassemble it, throw it into fire or water, or short-circuit it. Dispose of the battery pack as required by local ordinances or regulations.
Attention
Before the computer is powered on after FRU replacement, make sure all screws, springs, or other small parts are in place and are not left loose inside the computer. Verify this by shaking the computer and listening for rattling sounds. Metallic parts or metal flakes can cause electrical short circuits.
Attention
The system board is sensitive to, and can be damaged by, electrostatic discharge. Establish personal grounding by touching a ground point with one hand before touching these units.
An electrostatic discharge (ESD) strap (P/N 6405959) must be used to establish personal grounding.
66
FRU Removals and Replacements

1010 Backup Battery

Caution
The backup battery is a lithium battery and can cause a fire, an explosion, or severe burns. Do not recharge it, remove its polarized connector, disassemble it, heat it above 100°C (212°F), incinerate it, or expose its cell contents to water. Dispose of the battery as required by local ordinances or regulations. Use of an incorrect battery can result in ignition or explosion of the battery.
Note
Loosen (but not remove) the screw .1/.
1
2
3
1
ThinkPad 600 67
2
FRU Removals and Replacements
Top View
1
1

1020 DIMM

2
68
FRU Removals and Replacements

1030 Battery Pack

Unlock
Lock
1
2
ThinkPad 600 69
FRU Removals and Replacements

1040 Hard Disk Drive

Attention
Do not drop or apply any shock to the hard disk drive. The hard disk drive is sensitive to physical
shock. Incorrect handling can cause damage and permanent loss of data on the drive.
Before removing the drive, have the user make a backup copy of all the information on the drive if possible.
Never remove the drive while the system is operating or is in suspend mode.
1
3
2
Step Screw (Quantity) Color Torque
.1/ Coin screw
—Or— Security screw
Note: Use a 2.5-mm allen wrench to remove the security screw.
Note
Make sure that the HDD connector is firmly connected.
Black
70
FRU Removals and Replacements

1050 UltraslimBay Device

The artwork shows the FDD in the UltraslimBay, one of the CD-ROM drive, DVD Drive, battery pack, or HDD with adapter is available in the UltraslimBay.
1
2
When the security screw is installed
In step .1/, use a 2.5-mm allen wrench to remove the security screw.
ThinkPad 600 71
FRU Removals and Replacements

1060 Keyboard Assembly

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)
1
2
3
5
4
Turn the computer right side up.
Step Screw (Quantity) Color Torque
.1/ M2.5 × 19.5 mm,
nylon-coated (3)
.2/ M2.5 × 16 mm,
nylon-coated (2)
.3/ M2.5 × 4.8 mm,
nylon-coated (1)
Black 4 kgcm
Black 4 kgcm
Black 4 kgcm
72
FRU Removals and Replacements
Step Screw (Quantity) Color Torque
.4/ M2.5 × 3 mm,
nylon-coated (4)
.5/ M2.5 × 4.8 mm,
nylon-coated (1)
Yellow 4 kgcm
Black 4 kgcm
6
Latch
7
8
ThinkPad 600 73
FRU Removals and Replacements

1070 Keyboard

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Note
When you tear off the insulator in step .1/, do it gently for it is reused.
2
3
4
1
2
Bottom view
4
Step Screw (Quantity) Color Torque
.2/ M2.5 × 3 mm,
nylon-coated (6)
Yellow 4 kgcm
74
FRU Removals and Replacements

1080 Speakers

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Note
In step .1/, remove the insulator on the left speaker.
2
3
2
4
1
4
Bottom view
Step Screw (Quantity) Color Torque
.2/ M2.5 × 3 mm,
nylon-coated (6)
ThinkPad 600 75
Yellow 4 kgcm
FRU Removals and Replacements
Note
When replacing the right speaker, see the following artwork for its cable routing.
76
FRU Removals and Replacements

1085 Speaker Cable

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Note
In step .1/, remove the insulator on the left speaker.
2
4
1
3
Bottom view
Step Screw (Quantity) Color Torque
.2/ M2.5 × 3 mm,
nylon-coated (1)
Yellow 4 kgcm
ThinkPad 600 77
FRU Removals and Replacements

1090 LCD Assembly

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Note
For the LCD FRU removals and replacement, go to “2010 LCD Front Cover” on page 88.
1
4
3
2
3
5
6
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (4)
.3/ M2.5 × 4.8 mm,
nylon-coated (4)
.4/ M2.5 × 4.8 mm,
nylon-coated (1)
Black 4 kgcm
Black 4 kgcm
Black 4 kgcm
7
78
FRU Removals and Replacements

1100 PC Card (PCMCIA) Slot Assembly

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
2
Connector
Step Screw (Quantity) Color Torque
.1/ M2.0 × 9.5 mm,
nylon-coated (4)
Black 2.5 kgcm
1
3
ThinkPad 600 79
FRU Removals and Replacements

1110 Modem Card

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
1
Connector
3
2
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (2)
Black 4 kgcm
80
FRU Removals and Replacements

1115 System Kit for RFID

Note
This FRU is only for 600E (2645-AAU) only.
Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)Modem Card (1110)

1120 Sub Card

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)LCD Assembly (1090)
ThinkPad 600
81
FRU Removals and Replacements
2
3
1
Step Screw (Quantity) Color Torque
.2/ M2.5 × 4.8 mm,
nylon-coated (2)
Black 4 kgcm
82
FRU Removals and Replacements

1130 CPU Card and Fan

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Step Screw (Quantity) Color Torque
.1/ M2.0 × 9.5 mm,
nylon-coated (1)
.3/ M2.0 × 9.5 mm,
nylon-coated (4)
Black 2.5 kgcm
Black 2.5 kgcm
ThinkPad 600 83
FRU Removals and Replacements
5
Fan
6
CPU card
Step Screw (Quantity) Color Torque
.5/ M2.0 × 4.0 mm,
nylon-coated (2)
Note
When you replace the CPU card, press only on the places indicated in the figure. Press both sides at
the same time. Do not press only one side or any other part of the card..
Black 2.5 kgcm
84
FRU Removals and Replacements

1140 Guide Rail, Mic. Cable, or TV Out Card

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)
Note
TV out card is available for 600E model only.
For 600
Step Screw (Quantity) Color Torque
.4/ M2.0 × 9.5 mm,
nylon-coated (1)
.5/ M2.5 × 4.8 mm,
nylon-coated (3)
ThinkPad 600 85
Black 2.5 kgcm
Black 4 kgcm
FRU Removals and Replacements
For 600E
Step Screw (Quantity) Color Torque
.4/ M2.0 × 9.5 mm,
nylon-coated (1)
.5/ M2.5 × 4.8 mm,
nylon-coated (2)
.7/ M2.5 × 7 mm,
nylon-coated (2)
Black 2.5 kgcm
Black 4 kgcm
Yellow 4 kgcm
Note
Make sure the connector on the TV out card is firmly connected.
86
FRU Removals and Replacements

1150 System Board

Backup Battery (1010)
DIMM (1020)
Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)LCD Assembly (1090)PC Card (PCMCIA) Slot Assembly (1100)Modem Card (1110)Sub Card (1120)CPU Card and Fan (1130)TV Out Card (1140)
2
3
4
1
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (3)
.2/ M2.5 × 4.8 mm,
nylon-coated (1)
ThinkPad 600 87
Black 4 kgcm
Black 4 kgcm
FRU Removals and Replacements

2010 LCD Front Cover

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)LCD Assembly (1090)
Important
The TFT LCD for the notebook computer contains over 2,359,296 thin-film transistors. A small number of missing, discolored, or constantly lighted dots is characteristic of TFT LCD technology, but excessive pixel problems can cause viewing concerns. The LCD should be replaced if the number of missing, discolored, or lighted dots in any background is 21 or
more.
12.1-Inch TFT Panel (600 Only)
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (2)
Black 4 kgcm
88
FRU Removals and Replacements
13.3-Inch TFT Panel
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (2)
.1/ M2.5 × 4.8 mm,
nylon-coated (4)
Black 4 kgcm
Black 4 kgcm
ThinkPad 600 89
FRU Removals and Replacements
13.0-Inch HPA Panel (600 Only)
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coating (2)
.1/ M2.5 × 4.8 mm,
nylon-coating (4)
Black 4 kgcm
Black 4 kgcm
90
FRU Removals and Replacements

2020 LCD Hinges and Cables

Battery Pack (1030)Hard Disk Drive (1040)CD-ROM Drive or Diskette Drive (1050)Keyboard Assembly (1060)LCD Assembly (1090)LCD Front Cover (2010)
12.1-Inch TFT Panel (600 Only)
Step Screw (Quantity) Color Torque
.2/ M2 × 4.8 mm, (8) Black 4 kgcm
ThinkPad 600 91
FRU Removals and Replacements
13.3-Inch TFT Panel
Note
When you replace the cables, make sure the cables are not caught by the LCD panel.
92
FRU Removals and Replacements
Step Screw (Quantity) Color Torque
.1/ M2.5 × 4.8 mm,
nylon-coated (1)
Black 4 kgcm
ThinkPad 600 93
FRU Removals and Replacements
13.0-Inch HPA Panel (600 Only)
Note
When you replace the cables, make sure the cables are not caught by the LCD panel.
Step Screw (Quantity) Color Torque
.2/ M2.5 × 4.8 mm,
nylon-coated (6)
Black 4 kgcm
94