Hyundai W240S User Manual

NEXT
User’s Guide
Type No. L24C0F080
Model. W240S
Multi Function 2D/3D Wide Monitor
U.S.A.
NOTE : This equipment has been tested and found to comply with the limits for a
Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet of a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for assistance.
Changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Connecting of peripherals requires the use of grounded shielded signal cables.
WE HYUNDAI IT CORP.
Ami-ri Bubal-Eub Ichon-Si Kyungki-Do 467-860 KOREA
declare under our sole responsibility that the product:
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
following the provisions of the Low Voltage Directive 73/23/EEC, 93/68/EEC and the EMC Directive 89/336/EEC.
KOREA / May 6, 2008
Jong Won, Choi Ho Suk, Chon
(Place and date of issue) (Name and signature of
authorized person)
DECLARATION OF CONFORMITY
Kind of equipment : LCD MONITOR
Type-Designation : L24C0F080
Safety : EN60950-1:2002 EMC : EN 55022/1998+A1:2000+A2:2003
EN 55024 :1998+A1:2001+A2:2003 EN 61000-3-2:2000+ A2:2005+A2:2005 EN 61000-3-3:1995+A1:2001
Accredited testlaboratory:
TÜV Rheinland
Am Grauen Stein
51105 Köln
W240S Multi Function 2D/3D Wide Monitor
Contents
1. Introduction ...................................1/29
2. Safety Information ........................1/29
3. Cautions for Health &Safety ..........3/29
4. Handling InstructionsHow to use ..5/29
5. 3D Monitor SettingGuide...............6/29
6. Q&A for 3D Mod..............................6/29
7. 3D Mode Specification ...................8/29
8. Installing the monitor....................9/29
9. Adjusting the picture ..................19/29
10. Display power management ....25/29
11. Troubleshooting ........................26/29
12. Specifications ............................29/29
W240S Multi Function 2D/3D Wide Monitor
1. Introduction
2. Safety Information
1/29
This manual contains instructions for installing and operating HYUNDAI IT CORP. W240S.
HYUNDAI IT CORP. W240S is a highly ergonomic color display unit.
• 24” viewable WUXGA LCD
• High quality screen re-scaling capability
• 100-240V AC input voltage
• VESA DPMS (Display Power Management Signaling)
• VESA DDC1/2B compatibility
• Advanced digital On-Screen-Display controls
• Digital Signal Input by DVI-1.0 Compatability
• Fast and accurate auto adjustment
• Most advanced image scaling
• Supporting VESA Flat Panel Monitor Physical Mounting Interface
• 2D/3D Convertible
This Monitor has been engineered and manufactured to assure your safety. You can prevent serious electrical shock and other hazards by keeping in mind the following:
Do not place anything wet on the monitor or the power cord. Never cover the ventilation openings with any material and never touch them with metallic or inflammable materials.
W240S Multi Function 2D/3D Wide Monitor
2/29
Avoid operating the monitor in extreme heat, humidity or areas affected by dust. Temperature : 5~40°C Humidity : 30~80RH
Be sure to turn the monitor off before plugging the power cord into the socket. Make sure that the power cord and the other cords are securely and rightly connected.
Overloaded AC outlets and extension cords are dangerous, as are frayed power cords and broken plugs, which may cause electric shock or fire. Call your service technician for replacement.
Do not use sharp tools such as a pin or a pencil near the monitor, as they may scratch the LCD surface.
Do not use a solvent, such as benzene, to clean the monitor, as it will damage the LCD surface.
W240S Multi Function 2D/3D Wide Monitor
Cleaning and Maintenance
3. Cautions for Health & Safety (Before use)
- Warning
• To avoid to risk of electric shock, do not disassemble the Cabinet of display Unit. The Cabinet is not user-serviceable. Remember to unplug the display unit from the power outlet before cleaning.
• Do not use alcohol (methyl, ethyl or isopropyl) or any strong dissolvent. Do not use thinner or benzene, abrasive cleaners or compressed air.
• Do not wipe the screen with a cloth or sponge that could scratch the surface.
• To clean your antistatic screen, use water and a special microfiber screen cleaning tissue used in optical lens cleaning, or lightly dampen a soft, clean cloth with water or a mild detergent.
• If the instructions above do not help in removing stains, contact an authorized service agent.
• Viewing Time - Do not view the stereoscopic images continuously and take a
rest every 15 minutes.
• Please view the monitor screen within a distance of 60cm ~ 1M.
• If you have any of the following symptoms, consult with a doctor before use.
- Neck, ear, heart disorder
- Convulsion, photosensitivity
- High blood pressure
3/29
W240S Multi Function 2D/3D Wide Monitor
- Caution
• If you have any problems with your body such as convulsion, paralysis,
disorientation, fainting and confusion, etc. while using it, stop using it and go to your doctor.
• If you feel any problems as follows, stop using it and take a rest.
- Pain in the eyes, tears, dry eyes, heavy eyelids
- Nausea, vomiting, dizziness, stomach pain, perspiration
- Headache, heaviness in head or dizziness, dry mouth
- Sickness
If you don't feel better, go to your doctor.
• Intoxicated and/or medicated persons should not use this product.
• Persons with nearsightedness or farsightedness, difference in left and right
eyesight, or astigmatism should correct their visions adequately before using it. Using the polarized glasses over glasses or contact lens does not cause any problem.
4/29
!
W240S Multi Function 2D/3D Wide Monitor
- Fire / Accident Prevention
4. Handling Instructions
How to use
5/29
• Do not handle the LCD monitor with bare hands. It can cause you to get injured.
• Do not place a heavy object over LCD monitor, bend nor give it a shock. It can
break down or get damaged.
Do not disassemble or modify it. It can break down or cause a fire. If it breaks down or get damaged, unplug the power cord and have it repaired.
• When viewing stereoscopic images, please use the special polarized glasses.
Without this glasses, you can not enjoy stereoscopic images.
If you use some polarized glasses from other companies, you can not fully enjoy the stereoscopic images.
• Do no use the polarized glasses for other uses other than 3D viewing.
• Do not touch the surface of the monitor screen with bare hands.
• When the surface of the monitor screen gets dirty, wipe it clean softly with a
smooth cloth (cotton flannel). Using detergent, solvent, etc. can cause it to get damaged.
• If the stereoscopic images do not display correctly, read the 3D software “User's
Manual” first, and follow it as described in the manual. If they still display improperly, do not disassemble it and contact the Customer Support
• For how to operate LCD monitor, read "Handling Manual."
Please DO NOT disassemble the product.
!
W240S Multi Function 2D/3D Wide Monitor
5. 3D Monitor Setting Guide
6. Q&A for 3D Mod
• Optimal resolution for 3D viewing is 1920*1200/60Hz. If you run it on different resolutions, its 3D effects can decrease.
• Use signal input source at RGB under PC mode or DVI mode. DVI mode is recommended.
• For 3D viewing, go to 1:1 mode under Display Control of OSD MENU before viewing it (Monitor Manual: see 24 page). Viewing on a different mode may decrease 3D effects.
• On 1:1 mode, the screen size changes according to the input resolution. It doesn't mean that it has some problems with it. It just operates 1:1 mode without scaling the input signal.
1. There is something like oil stain on the monitor screen.
It is due to interferences of light waves within the air layers between the surface of LCD and the 3D filter. It is not defective.
2. 3D stereoscopic images are seen as two separate images.
When you don't wear 3D glasses enclosed Please use the 3D glasses. When you view it away from visual angle.
- To view 3D stereoscopic imaging optimally, you'd better keep the distance of 60 cm
6/29
Loading...
+ 23 hidden pages