Husqvarna AB has a policy of continuous
product development and therefore
reserves the right to modify the design and
appearance of products without prior
notice. Long--term exposure to noise can
result in permanent hearing impairment.
Always use approved hearing protection.
This operator’s manual describes in detail
how to use and service the blower and
how to carry out regular maintenance. It
also describes which measures should be
taken to achieve maximum safety while
operating the blower, how the safety devices work and how they should be serviced.
Note! The section of the manual that deals
with safety, must be read and understood
by all persons who come in contact with
the blower.
This operator’s manual has been written
for those who need guidance when it
comes to fault tracing, thorough servicing
and carrying out corrective maintenance of
the blower.
There are warning symbols on the blower.
Should any of the warning symbols on the
blower become disfigured or worn, new ones
should be ordered and fitted to the blower as
soon as possible. Note that some of the
warning symbols may be molded in certain
components of the blower.
The blower is used for blowing away
leaves and other debris on the ground.
When operating the blower, the operator
must stand with both feet firmly on the
ground.
WARNING: Under no circum-
stances may the design of the
machine be modified without the
permission of the manufacturer.
Always use genuine accessories.
Non--authorized modifications
and/or accessories can result
in serious personal injury or the
death of the operator or others.
Your warranty may not cover
damage or liability caused by the
use of non--authorized accessories or replacement parts.
545133423 Rev. 4 9/6/07
English---2
KEY TO SYMBOLS
Checks and/or maintenance shall be
carried out after
having switched off
the engine and disconnected the spark plug.
Cleaning at regular
intervals is required.
Approved protective
goggles or visor must
be worn.
Approved protective
goggles or visor, ear
protection, and face
mask in dusty envir o nments must be worn.
WARNING! The blower can be dangerous!
Careless or improper
use can cause serious, even fatal injury.
Read the operator’s
manual carefully and
make sure that you
understand the
contents before using
the blower.
WARNING! Make sure
that the inlet cover is
locked in the closed
position or that the
vacuum tube is mounted on the blower. Never
touch the impeller unlesstheunitisoff,the
impeller has stopped
moving and the spark
plug is disconnected.
Always wear approved,
protective gloves.
WARNING! The blower
may throw objects at
high velocity that can
ricochet and hit the
operator. This may
cause serious eye
damage.
X
X
X
XX
XX
XX
XX
XX
XX
The blower operator
must make sure that
no bystanders or
animals come nearer
than 15 meters.
Whenever several
operators are working
inthesameworkarea,
they should maintain a
safe distance of at
least 15 meters from
one another.
Choke
Refueling
Stop switch
Instructions on how to
open the inlet cover.
This product is in accordance with applicable EC directives.
Noise pressure level
measured at 7,5 metres
distance.
Noise emissio n to the
environment according
to the European
Community’s Directive.
The machine’s emission is specified in the
Technical data section
andonthe
label.
Other symbols/decals on the machine
refer to special certification requirements
for certain markets.
XX
X
X
X
X
XX
X
X
545133423 Rev. 4 9/6/07
English--- 3
SAFETY INSTRUCTIONS
Personal safety equipment
Persons who use the blower shall wear the
following safety equipment:
1. Approved ear protection.
2. Approved eye protection.
3. Approved protective gloves.
4. Boots or work shoes with a non--slip sole.
5. Face mask when operating the blower in
dusty environments.
Personal safety
The following instructions apply to persons
operating the blower:
S The operator shall have read and under-
stood the contents of this manual.
S Do not wear loose clothing, scarves or
neckchains or let long hair hang loose,
since these can be drawn into rotating
parts of the blower and cause injury.
S Do not operate the blower while under
the influence of alcohol, drugs or when
you are tired.
S Do not allow minors to operate the
blower.
S Always have a first aid kit nearby.
Fuel safety
WARNING: The fuel used to run
the blower has the following
dangerous characteristics:
1. Volatile liquid: its vapor and
exhaust fumes are poisonous.
2. Direct contact can cause skin
irritation.
3. It is extremely flammable.
Special safety instructions apply to the type
of fuel used for the blower. These instructions are specified under the Fuel handling
section.
545133423 Rev. 4 9/6/07
Muffler
The muffler is designed to give the lowest
possible noise level and to direct the engine’s exhaust fumes away from the operator. Mufflers fitted with catalytic converters
are also designed to reduce harmful exhaust components.
WARNING: The exhaust fumes
from the engine are hot and may
contain sparks which can start a fire.
Never start the machine indoors or
near flammable material!
WARNING: Mufflers fitted with
catalytic converters become extremely hot during use and after stopping.
This also applies at idling speeds.
Contact can result in burns to the
skin.Beawareoftheriskoffire!
Safety equipment
WARNING: The blower must
never be used if any of the safety
devices or guards are missing,
damaged or not in working order.
The blower is equipped with a number of
safety devices and guards for the prevention of accidents. These are described in
the general description of the blower.
The safety devices and guards also require
regular inspection and maintenance. These
measures and the interval at which they
should be carried out are specified in the
Maintenance section.
Safety while operating the
blower
S Do not allow bystanders or animals to be
in the work area, i.e. 15 meters from the
operator.
S The blower may throw objects at high
velocity that can ricochet and hit the operator. This may cause serious eye damage.
S Never point the blower nozzle toward
people or animals.
S Stop the engine before fitting or disman-
tling accessories or other components.
S Never operate the blower if any of the
guards are missing.
S Never operate the blower in poorly venti-
lated spaces where exhaust fumes might
otherwise be inhaled.
S Stop the engine before refueling. Move
the unit at least 3 meters from fueling site
before attempting to start.
S The catalytic muffler is extremely hot
while the blower is running and after it
has stopped. The same applies when the
blower is running at idling speed. Be
aware of the danger of fire, especially
while operating the blower near flammable materials and/or where flammable
fumes are present.
English--- 4
SAFETY INSTRUCTIONS
S Be careful, particularly ifleft hand opera-
tion is applied. Avoid any direct body contact with inlet cover area. Keep jewelry,
loose clothing, or clothing with loosely
hanging straps, ties, tassels, etc., away
from inlet cover area.
S Do not operate the blower while standing
on a ladder or a stand.
Other safety measures
S Operate the blower only at reasonable
hours, i.e. not early in the morning or late
at night when people might be disturbed.
Comply with times listed in local ordinances. Usual recommendations are 9:00
a.m. to 5:00 p.m., Monday through Saturday.
S Operate the blower at the lowest possible
throttle setting to do the job.
S Check the condition of the blower before
operation, especially the muffler, air intake
and air filter.
S Use a rake or a broom to loosen ground
debris before blowing.
S Under dusty conditions, slightly spray the
work area with a hose.
S Conserve water by using blowers instead
of hoses for many lawn and garden
applications, including areas such as roof
gutters, screens, patios and gardens etc.
S Watch out for children, pets, open windows
or vehicles, and blow debris safely away.
S Use the full nozzle extension so the air
stream can work close to the ground.
S After using the blower, clean up and
dispose of debris in trash receptacles.
545133423 Rev. 4 9/6/07
English--- 5
The blower
1
DESCRIPTION
3
4
2
23
9
17
21
20
22
10
19
16
18
15
14
24
10
1. Shoulder strap (125BV
2. Throttle trigger14. Standard nozzle
)13. Fan impeller
X--SERIES
3. STOP switch15. High velocity nozzle
4. Variable speed control(125B
5. Fan housing16. Blower tube
X- -SERIES
and 125BV
6. Fuel cap17. Tube clamp bolt
7. Air filter18. Tube clamp nut
8. Choke19. Muffler
9. Primer bulb20. Ground wire
10. Inlet cover21. Starter handle
11. Vacuum handle22. Starter device
(125B
12. Cutters (12 5B
125BV
X--SERIES
X--SERIES
and 125BV
and24. Operator’s manual
X--SERIES
)
)23. Carburetor adjustment screws
X- -SERIES
12
11
13
X- -SERIES
7
8
6
5
)
545133423 Rev. 4 9/6/07
English--- 6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.