Husky A05051 User Manual

Part No. A05051 Rev. 0 07/26/04
READ AND SAVE THESE INSTRUCTIONS
Air Compressor
Operator’s Manual
Model No. Y1010
ESP AÑOL . . . . . . . . . . . . . . . .21-39
FRANÇAIS . . . . . . . . . . . . .40-60
Questions? 1-800-888-2468
A05051
SAFETY GUIDELINES - DEFINITIONS
Indicates an
imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation
which, if not avoided, could
result in
death or serious injury
.
Indicates a potentially hazardous situation
which, if not avoided, may
result in
minor or moderate injury.
Used without the
safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in pr
operty damage.
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.
IMPORTANT SAFETY INSTRUCTIONS
Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to
cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools.
When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.
SAVE THESE INSTRUCTIONS
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
A05051
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
HAZARD
WARNING: Risk of explosion or fire
How To Prevent It
What Could Happen
It is normal for electrical contacts within the motor and pressure switch to spark.
If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.
Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.
Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
Always operate the compressor in a well ventilated area free of combustible
materials, gasoline, or solvent vapors.
If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose
may be required.
Store flammable materials in a secure location away from compressor.
Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that would
restrict the flow of fresh air to the ventilation openings.
Operate compressor in a clean, dry well ventilated area. Do not operate unit
indoors or in any confined area. Always remain in attendance with the
product when it is operating.
Always disconnect electrical power by placing the Off/Auto-On to the "Off" position and drain tank daily or after each use.
A05051
WARNING: Risk of Bursting
Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury.
How To Prevent It
What Could Happen
WARNING: Risk from Flying Objects
The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or
personal injury.
Always wear ANSI Z87.1 approved safety glasses with side shields when using the compressor.
Never point any nozzle or sprayer toward any part of the body or at other people or animals.
Always turn the compressor off and bleed pressure from the air hose and tank
before attempting maintenance, attaching tools or accessories.
HAZARD
HAZARD
Drain tank daily or after each use. If
tank develops a leak, replace it immediately with a new tank or replace the entire compressor.
Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
Modifications or attempted repairs to the tank.
Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure.
Never drill into, weld, or make any modifications to the tank or its
attachments.
Excessive vibration can weaken the air tank and cause rupture or explosion
The tank is designed to withstand specific operating pressures. Never make
adjustments or parts substitutions to alter the factory set operating pressures.
For essential control of air pressure, you must install a pressure regulator and pressure gauge to the air outlet (if not equipped) of your compressor. Follow the
equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments.
A
TTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air tools, spray guns, air operated
accessories, tires, and other inflatables can cause them to explode or fly apart, and could result in serious injury.
How To Prevent It
What Could Happen
A05051
WARNING: Risk to Breathing
WARNING: Risk of Electrical Shock
HAZARD
HAZARD
Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock.
Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution.
See grounding instructions.
Never operate the compressor outdoors when it is raining or in wet conditions.
Never operate compressor with protective covers removed or damaged.
Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes.
Make certain that the electrical circuit to which the compressor is connected
provides proper electrical grounding, correct voltage and adequate fuse protection.
The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon
monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants can cause serious injury or death.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides, weed killers, may contain harmful
vapors and poisons.
Air obtained directly from the compressor should never be used to supply air for human consumption. In order to use air
produced by this compressor for breathing, suitable filters and in-line
safety equipment must be properly installed. In-line filters and safety equipment used in conjunction with the compressor must be capable of treating air to all applicable local and federal codes prior to human consumption.
Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Use a NIOSH/ MSHA approved respirator designed for use with
your specific application.
How To Prevent It
What Could Happen
How To Prevent It
What Could Happen
A05051
WARNING: Risk of Burns
Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
WARNING: Risk from Moving Parts
Never operate the compressor with guards or covers which are damaged or removed.
Moving parts such as the pulley, flywheel,
and belt can cause serious injury if they come into contact with you or your clothing.
WARNING: Risk of Falling
A portable compressor can fall from a table, workbench, or roof causing
damage to the compressor and could result in serious injury or death to the operator.
Always operate compressor in a stable secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations.
HAZARD
HAZARD
HAZARD
Any repairs required on this product should be performed by authorized service center personnel.
Attempting to operate compressor with damaged or missing parts or attempting
to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious
injury.
How To Prevent It
What Could Happen
How To Prevent It
What Could Happen
How To Prevent It
What Could Happen
A05051
Review and understand all instructions and warnings in this manual.
Become familiar with the operation and controls of the air compressor.
Keep operating area clear of all persons,
pets, and obstacles. Keep children away from the air
compressor at all times.
Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this
product.
Equip area of operation with a fire extinguisher.
Do not operate machine with missing, broken, or unauthorized parts.
WARNING: Risk of Unsafe Operation
Unsafe operation of your air compressor could lead to serious injury or death to you or others.
HAZARD
SAVE THESE INSTRUCTIONS
How To Prevent It
What Could Happen
A05051
ASSEMBLY
Tools Required for Assembly
1 - 9/16" open end wrench or
adjustable wrench
1 - adjustable wrench
Contents of Carton
1 - Air Compressor 1 - Air Hose 1 - Blow Gun and Inflation Kit
(7 pieces)
1- Inflator/Deflator Kit (7 pieces)
GLOSSARY
DUTY CYCLE
This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75%
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per
minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory.
average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.
When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
Model No. Y1010
Bore 1.875" Stroke 1.25" Voltage/Hertz/Phase 120V/60/1 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay
Air Reserve (gallons) 1.75
SCFM @ 40 psig 3.0 SCFM @ 90 psig 2.0
SPECIFICATION CHART
Accessories for this unit are available at the store the unit was purchased.
ACCESSORIES
Assemble Inflator/Deflator Kit
The blow gun (c) and blow gun adapter (e) from the accessory kit is needed to use the inflator/deflator kit.
1. Attach the blow gun to hose.
2. Attach blow gun adapter to blow gun.
3. Attach the inflating needle (h), tapered nozzle (j), or high flow inflator/deflator body (k) to the blow gun adapter on the blow gun.
4. If using the inflator/deflator choose the nozzle needed and see the "How to use High Flow Inflator/Deflator Adapter Body" instructions in the Operation section for the correct procedure.
Assemble Accessories
The unit is supplied with an accessory kit and inflator/deflator kit, choose the accessory needed.
Assemble Accessory Kit
To Assemble Female Tire Chuck
1. Assemble female tire chuck (a) to hose (b) and tighten securely with wrenches.
To Assemble Accessories
1. Attach the blow gun (c) to hose (b).
Risk of unsafe
operation. If an accessory is not being used with the blow gun, the safety nozzle MUST be assembled.
A05051
Assemble Hose
1. Assemble hose to air outlet.
IMPORTANT: The hex fitting on the air outlet MUST be held in place with a wrench when tightening hose onto air outlet.
Unpacking
1. Remove unit from carton and
discard all packaging. NOTE: Save all parts bags.
Safety Nozzle
a
c
b
e
d
g
f
h
c
e
h j
k
2. Assemble the safety nozzle (d), tapered inflator (g), rubber blow gun tip (h), or blow gun adapter (e) to blow gun. NOTE: To use the inflating needle (f) the blow gun adapter has to be assembled to blow gun.
3. Attach the inflating needle (f) to the blow gun adapter on the blow gun.
10- ENG
A05051
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
2. Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
Risk of Electrical Shock. IMPROPER
GROUNDING CAN RESULT IN ELECTRICAL SHOCK. Do not modify the plug provided. If
it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified electrician.
Grounding Pin
Grounded Outlets
Plug
INSTALLATION
GROUNDING INSTRUCTIONS
Risk of Electrical
Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.
1. The cord set and plug with this
unit contains a grounding pin. This plug MUST be used with a grounded outlet.
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will restrict the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
11- ENG
A05051
Extension Cords
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has
a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product
in good condition
no longer than 50 feet
16 gauge (AWG) or larger. (Wire
size increases as gauge number decreases. 14, 12, 10, and 8 AWG may also be used.
Voltage and Circuit Protection
Refer to the specification chart for the voltage and minimum branch circuit requirements.
Risk of Unsafe
Operation. Certain air compressors can be operated on a 15 amp circuit if the following
conditions are met.
1. Voltage supply to circuit must comply with the National Electrical Code.
2. Circuit is not used to supply any other electrical needs.
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.
12- ENG
A05051
Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.
Description of Operation
Become familiar with these controls before operating the unit.
Off/Auto-On Switch: Turn this switch to "Auto-On" to provide automatic power to the pressure switch and "Off" to shut off the power.
Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
Safety Nozzle
Air Hose
Safety
Valve
Regulator
Outlet Pressure Gauge
Power
Cord
Off/Auto-On Switch
Blow Gun
Blow Gun Adapter
Inflating needle
Female Tire Chuck
Rubber Tip Nozzle
Tapered Inflator
Accessory Storage
High Flow Inflator/Deflator Adapter Body
Seal Ring
Nozzles to be used with the High Flow inflator/Deflator adapter body
Telescopic Handle
Tapered Inflator
Inflating needle
13- ENG
A05051
Regulator: Controls the air pressure shown on the outlet pressure gauge. Tur n knob clockwise to increase pressure and counterclockwise to decrease pressure.
Female Tire Chuck: Attaches to the hose end to be used to inflate tires. Note: To ensure correct tire pressure use a tire pressure gauge.
Blow Gun: Ideal for blowing, cleaning, and inflating. Depress lever on to release the air. Attaches to hose end.
Safety Nozzle: Prevents pressure build-up. Attaches to blow gun outlet.
Blow Gun Adapter: Attaches to the blow gun to allow the tapered Inflator, inflating needle, or high flow inflator/deflator adapter body to be used.
Inflating needles: Used to inflate sport balls. Requires blow gun adapter.
Tapered Inflator: Used to inflate toy inflatables/air mattresses. Brass tapered inflator attaches to blow gun outlet and plastic tapered inflator requires the blow gun adapter.
Rubber Tip Nozzle: Used to inflate toy inflatables/air mattresses. Attaches to blow gun outlet.
High Flow Inflator/Deflator Adapter Body: Used with inflator/deflator
nozzles it attaches directly to the universal valve adapter to inflate or deflate air mattresses, small boats, inflatable toys, and other inflatable items that use a large volume of low­pressure air. Requires blow gun adapter.
Inflator/Deflator Nozzles: Used with the high flow inflator/deflator adapter body.
Seal Ring: Used with inflator/deflator nozzles to prevent air from leaking out of inflatables with very large air inlets.
Drain Valve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
How to Use Your Unit
How to Stop:
1. Set the Off/Auto-On switch to "Off".
Before First Start-up
Break-in Procedure
Risk of Unsafe
Operation. Serious damage may result if the following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service.
1. Make sure the Off/Auto-On
switch is in the "Off" position.
2. Turn the regulator knob
counterclockwise until it stops.
3.
Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Check Valve (not shown): When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.
14- ENG
A05051
How to Start:
1. Turn the Off/Auto-On switch to "Auto-On" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.
2. Turn the regulator knob clockwise until desired pressure is reached. NOTE: To use the suggested pressure readings on the label, turn the regulator knob clockwise until the needle on the pressure gauge aligns with the desired suggested pressure reading number.
Before Each Start-Up:
1. Place Off/Auto-On switch to "Off" and close air regulator.
2. Turn the regulator knob counterclockwise until it stops.
3. Attach hose and accessories.
Risk of Bursting.
Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
How to Use Telescopic Handle and Wheels for Easy Mobility
1. Press the release button and slide handle out until it locks into place.
2. Pull or push unit as shown. IMPORTANT: This handle is for pushing or pulling the unit. DO NOT lift the unit by this handle.
3. To lower handle, press the release button and push handle until it snaps into place for storage.
3. The compressor is ready for use.
needle
4. Open the drain valve fully (counterclockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.
5. Move the Off/Auto-On switch to "Auto-On" position. The compressor will start.
6. Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.
7. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.
The compressor is now ready for use.
15- ENG
A05051
4. Insert nozzle into inflatable and then start inflator, see "How to Start" paragraph.
NOTE: If inflatable is not getting firm enough, place thumb over the "deflation" outlet to allow air to go directly into the inflatable.
Risk of Bursting.
DO NOT over­inflate. Keeping thumb over "Deflation" outlet could cause inflatable to over-inflate. Use caution when placing thumb over "Deflation" outlet.
How to use High Flow Inflat or/ De fla to r Adapter Body
1. Assemble the high flow inflator/deflator body as described in the Assembly section.
2. Choose nozzle to be used to inflate or deflate. NOTE: The seal ring may be used with any of the nozzles to prevent air from leaking out of inflatables with very large air inlets.
3. The high flow inflate/deflate adapter body attachment has an "inflation" outlet and "deflation" outlet. Attach the nozzle to the preferred outlet. NOTE: "Inflation" and "Deflation" are marked at outlets.
Nozzle attached to "deflation" outlet
Nozzle attached to "inflation" outlet
16- ENG
A05051
MAINTENANCE
Customer Responsibilities
Daily or after each use
Before each use
Check Safety Valve Drain Tank
NOTE: See "Operation" section for the location of controls.
Risk of Unsafe
Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
To Check Safety Valve
Risk of Bursting. If
the safety valve does not work properly, over­pressurization may occur, causing air tank rupture or an explosion.
1. Before starting compressor, pull
the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, contact a trained service technician.
To Drain Tank
NOTICE: Allow unit to cool before
draining tank, drain valve becomes hot during operation.
1. Set the Off/Auto-On switch to
"Off".
2. Turn the regulator knob counter-
clockwise to set the outlet pressure to zero.
3. Pull and hold ring on safety valve
allowing air to bleed from the tank until air pressure is minimized.
4. Place unit on blocks to lift unit off of ground.
5. Place suitable container under unit to catch water.
6. Slightly tilt unit and turn drain valve counter clockwise to open.
7. Place unit back onto blocks to drain water from air tank.
Risk of Bursting.
Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
8. After the water has been drained,
close the drain valve (clockwise). The air compressor can now be stored.
17- ENG
A05051
A05051
STORAGE
Before you store the air compressor, make sure you do the following:
1. Drain tank, see "To Drain Tank" paragraph in the "Maintenance" section of this manual for the correct procedure.
Risk of Bursting.
Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
2. Store accessories in the
accessory storage located on back of unit.
3. Wrap the electrical cord loosely, snap it into itself as shown for storage.
4. Hook blow gun as shown for storage.
5. Store the air compressor in a clean and dry location.
REPAIR PARTS
For Parts, Service, Warranty or other Assistance,
please call 1-800-888-2468.
18- ENG
A05051
It is normal for "some" pressure drop to occur.
If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section.
NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used).
Pressure reading on the regulated pressure gauge drops when an accessory is used.
TROUBLESHOOTING
Risk of Unsafe Operation. Performing repairs may expose
voltage sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.
PROBLEM
CAUSE
CORRECTION
Pressure switch does not shut off motor when compressor reaches "cut­out" pressure.
Pressure switch "cut-out" too high.
Move Off/Auto-On switch to the "Off" position, if the unit does not shut off contact a Trained Service Technician.
Contact a Trained Service Technician.
Excessive tank pressure - safety valve pops off.
Tube fittings are not tight enough.
Tighten fittings where air can be heard escaping. Check any exposed fittings with soapy water solution. Do Not
Overtighten.
Air leaks at fittings.
Possible defect in safety valve.
Operate safety valve manually by pulling on ring. If valve still leaks, Contact a Trained Service Technician.
Air leak from safety valve.
Possible defect in safety valve.
Knocking Noise.
Operate safety valve manually by pulling on ring. If valve still leaks, Contact a Trained Service Technician.
Apply sealant tape to threads of exposed fittings.
Loading...
+ 42 hidden pages