Huawei BTS3701B 2500M, BTS3701B-2500 Users Guide

BTS3701B V300R003 Installation Guide
Issue: 01 Date: 2010-03-20
HUAWEI TECHNOLOGIES CO., LTD.
Safety Precautions
Abide by All Safety Requirements
Abide by Local Laws and Regulations
When operating the equipment, abide by local laws and regulations.
Requirements for Personnel
The installation and maintenance personnel of Huawei equipment must be strictly trained. They are not allowed to install, operate, or maintain the equipment until they have mastered the correct operation method and got familiar with the safety requirements.
Symbol Descr iption
Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury.
Indicates a hazard with a medium or low level of risk, which if not avoided, could result in minor or moderate injury.
Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Indicates a tip that may help you solve a problem or save time. Provides additional information to emphasize or supplement important points of the
main text.
Personal Safety
• Directly contacting or indirectly contacting high voltage power supply through wet objects is lethally dangerous.
• Incorrect high voltage operations will cause incidents such as fire or a shock hazard.
• Never perform any high voltage AC operations or perform operations on a tower or a mast during a thunderstorm. It can be lethally dangerous.
• Any equipment must be grounded before it is connected to the power supply. Ungrounded equipment can be lethally dangerous.
• Never perform any hot-line operation.
• Strong RF signals are harmful to human health. Ensure that the transmit antennas are shut down before an antenna installation or maintenance operation on a tower or mast installed with multiple transmit antennas.
• During an operation involving optical cables, keep your eyes far away from optical output ports and do not directly look at the optical output ports with bare eyes.
• Take measures to prevent dusts from entering your respiratory tract or eyes when drilling holes.
• Before connecting cables to storage batteries, disconnect the storage batteries from the power supply. Otherwise, injuries may be incurred.
• When working aloft, take measures to prevent objects from falling.
Equipment Safety
• Before operating the equipment, check the electric continuity of the equipment that requires grounding to ensure that it is reliably grounded.
• The static electricity produced by human body may damage the static-sensitive components, such as LSI on boards. Take proper ESD prevention measures, for example, wear ESD wrist straps or gloves to prevent boards, modules, and electronic components from being destroyed by static of the human body.
• When operating storage batteries, prevent the battery short-circuiting and electrolyte overflow or leakage. The electrolyte corrodes metal objects and the boards, producing rust and causing board short-circuiting.
1
Copyright © Huawei Technologies Co., Ltd. 2010.
© All rights reserved.
Installation ProcessInstallation Tools
Measuring tape Marker Hammer drill Ladder
Vacuum cleaner Adjustable wrench Phillips screwdriver Rubber mallet
Diagonal pliers Level Wire stripper
z When an external antenna is used,
connect the antenna to the BTS3701B before installing the BTS3701B.
z When the BTS3701B is installed on a
wall, the integrated mode is recommended.
z The BTS3701B must be installed at least
0.5 m (1'-7 11/16'') away from the interference sources such as power supply and at least 2 m (6'-6 3/4'') away from the high frequency radiation sources.
The BTS3701B cannot be placed horizontally on a flat object, such as a table.
2
Space Requirements
Dimensions of the BTS3701B
a
230 mm (9 1/16'')
65 mm (2 9/16'')
165 mm (6 1/2'')
Minimum Space Requirements
b
250 mm (9 13/16'')
100 mm (3 15/16'')
300 mm (11 13/16'')
250 mm (9 13/16'')
170 mm (6 11/16'')
A minimum of 500 mm (1'-7 11/16'') should be reserved at the back of the BTS3701B only in the ceiling installation mode.
3
Installation Modes
Adapter
BTS3701B
Transitional
piece
Mounting bracket for the module
Installing the BTS3701B on a Wall (Separated Mode)
a
Ceiling mounting bracket
Mounting bracket for the adapter
Regular installation Reverse installation
Installing the BTS3701B on a Wall (Integrated Mode)
b
Regular installation Reverse installation
4
Installation Modes
The requirements for the installation carrier are as follows:
20 mm (13/16'') to 85 mm (3 3/8'')
20 mm
(13/16'') to 75
mm (2 15/16'')
20 mm (13/16'') to
65 mm (2 9/16'')
20 mm (13/16'') to
Pole
Installing the BTS3701B on a Pole (Separated Mode)
c
75 mm (2 15/16'')
Angle steel U-steel
20 mm (13/16'') to 65 mm (2 9/16'')
Regular installation Reverse installation
Installing the BTS3701B on a Pole (Integrated Mode)
d
Regular installation Reverse installation
5
Installation Modes
Installing the BTS3701B on a Ceiling
e
Regular installation Reverse installation
If the BTS3701B is installed on a ceiling, the ceiling must be made of concrete and can bear a weight of 323.6 N.m (2864.10 lbf.in.).
Installing the BTS3701B on a Wall
Determining Installation Positions of the
a
Mounting Brackets
88 mm (3 7/16'')
200 mm (7 7/8'')
88 mm (3 7/16'')
Drilling Holes and Installing Expansion Bolts
b
24 mm (15/16'') to 25 mm (1'')
For the integrated installation mode, determine only the installation position of the adapter.
6
Installing the BTS3701B on a Wall
Separated Mode
c
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
M3.5×20
Installation procedure
The procedures of regular installation and reverse installation are identical.
7
Installing the BTS3701B on a Wall
Integrated Mode
d
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
10 N.m
(88.51 lbf.in.)
The procedures of regular installation and reverse installation are identical.
8
Installing the BTS3701B on a Pole
Separated Mode
a
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
300 mm
(11 13/16'')
Integrated Mode
b
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
10 N.m
(88.51 lbf.in.)
The procedures of regular installation and reverse installation are identical.
9
Installing the BTS3701B on a Ceiling
Determining Installation Positions of
a
Bolts
Marking template
Installing the BTS3701B on a Ceiling
c
Drilling Holes and Installing
b
Expansion Bolts
24 mm (15/16'') to 25 mm (1'')
M3.5×20
Installation procedure
10 N.m
(88.51 lbf.in.)
The procedures of regular installation and reverse installation are identical.
10
Connecting Cables
Connected to...ConnectorCable
Straight­through
4-pin connector of the DC input power cable
If the delivered Ethernet cable [3 m (9'-10 1/8'')] does not meet the requirement, prepare one on site based on actual requirements.
cable
Power cable
DC input power cable
Powering On the BTS3701B
Connect the PA male connector to the AC power wiring bar to power on the BTS3701B.
RJ45 connector
RJ45 connector
4-pin connector
The other end is connected to the power adapter.
FE/GE port on the BTS3701B
Operator's transmission equipment
AC power wiring bar PA male connector Power adapterC7 female connector PWR port on the
BTS3701B
RUN/ALM
Red and green
Off
Blinking at 4 Hz (green) (on for 0.125s, off for
0.125s) On (red)
Blinking at 0.5 Hz (red) (on for 1s, off for 1s)
Blinking at 4 Hz (green) (on for 0.125s, off for
0.125s)
11
DescriptionStatus ColorIndicator
The power supply is normal. On GreenPower There is no power supply, or the
BTS3701B is faulty. The BTS3701B is running normally. Blinking at 0.5 Hz (green) (on for 1s, off for 1s) The BTS3701B is being loaded, or
the BTS3701B is not started. An alarm is generated, and the
BTS3701B needs to be replaced. An alarm is generated. Rectify the
fault based on the reported alarm. The FE port is securely connected. On GreenLINK Data is being transmitted and
received over the FE port. The FE port is insecurely connected. Off
Appendix: Cabling Routes for Different Installation Modes
Installing the BTS3701B on a Wall
a
Separated Mode Integrated Mode
Installing the BTS3701B on a Pole
b
Installing the BTS3701B
c
on a Ceiling
Separated Mode Integrated Mode
Straight-through cable DC input power cable Power cable
z When the BTS3701B is installed on a pole, fix the input power cable of the power adapter on the pole using a tie wrap.
z Before powering on the equipment, ensure that the antenna of the BTS3701B is vertical.
12
Installing the External Equipment
e
FE/GE POWER
OUT
N
e
t
e
q
u
ip
w
m
Powered device (PD)
IN
o
r
k
e
n
t
OUT
The distance between the PSE and the PD should be more than 1 m (3'-3 3/8''). The PSE cannot be installed on a ceiling.
Power sourcing equipment (PSE)
Appendix: Removing the Equipment
Spring pad
IN
13
Press the spring pad and rotate the BTS3701B clockwise to remove it.