1 Overview of Software Installation
1.1 Overview of Software Installation
BTS3601C software includes BTS operational software and terminal Operation &
Maintenance (O&M) software.
BTS operational software includes BOOT software, Central Processing Unit (CPU)
software, and Field Programmable Gate Array (FPGA) logic.
CPU software includes Micro-bts Base-band Processing Board (MBPB) software and
Micro-bts Transceiver Board (MTRB) software; while FPGA logic includes MBPB logic
and MTRB logic. The actual situation differs from one board type to another.
Terminal O&M software includes Local Maintenance Function (LMF) software (i.e.,
the local O&M software), and O&M Center (OMC) software (i.e., the remote O&M
software).
0
错误表格结果无效
LMF software comprises PC self-contained Telnet and File Transfer Protocol (FTP)
software, while OMC software is composed of BAM software and Client software.
1.1.1 BTS Operational Software
I. BOOT software
BOOT software serves to start the board. Before the delivery of the BTS3601C, the
BOOTROM in every board has already been installed with BOOT software. BOOT
software upgrade is usually realized by replacing the chip.
II. CPU software
CPU software is the core of system functions. It can be loaded in two ways:
lIf there is no old-version software on the board, it is necessary to load the board
(in the commissioning mode) with the software through the board network port.
lIf there is old-version software on the board, the software can be upgraded
through software loading by using local FTP software or remote O&M software.
III. FPGA logic
FPGA logic should be loaded to BTS3601C MBPB/MTRB. The loading mode is the
same as that of CPU software.
1-1
Installation Manual
iSiteC BTS3601C CDMA Base Station
&
Note:
The BTS operational software has been installed before delivery, so there is no need to install onsite.
However, the operational software needs to be upgraded or re-loaded upon version upgrade. For details,
please refer to Chapter 3 BTS Operation Software Installation.
1.1.2 Terminal O&M Software
I. Local O&M software
The local maintenance console is a portable computer installed with Windows9x
Operating System (OS), which contains the local O&M software. It includes FTP
Client (Ftp.exe) and Telnet Client (Telnet.exe).
The BTS3601C objects, including sites, cells, basebands, carriers, channels, etc.,
can be maintained with local maintenance commands.
Software Installation & System Commissioning
0
错误表格结果无效
Since the two programs (Ftp.exe and Telnet.exe) are provided by Windows9x OS,
there is no need for extra installation.
II. Remote O&M software
Remote O&M software (OMC) of the Base Station Subsystem (BSS) adopts the
Client/Server structure.
Through the Client, users can input operation commands, which are then processed
by the server (BAM) in a centralized way. After the processing, these commands are
transmitted to the foreground (including BSC and BTS), which will then return the
operation result (success, failure, timeout, exception, etc.). BAM will record the result
and transmit it in a certain report format to the Client.
With OMC, the user can perform remote maintenance and monitoring over all the
BTSs that are under his control.
The collected site information can also be used for network planning.
The installation of OMC software involves the installation of BAM server software and
the installation of the Client software.
The Client software is divided into three kinds: BSC Client, BTS3612 Client and
BTS3601C Client.
This manual describes the installation of BTS3601C Client software only. For the
installation of BAM server and other Client software, please refer to the
corresponding installation manual.
1-2
Installation Manual
iSiteC BTS3601C CDMA Base Station
2.3.3 Software Installation and Instructions ................................................................2-3
i
Installation Manual
iSiteC BTS3601C CDMA Base Station
2 Installing BTS Terminal O&M Software
2.1 Software Features
BTS3601C terminal O&M software (hereinafter referred to as "terminal O&M
software") is classified into two categories: the remote O&M and the local O&M.
These two categories differ in the way they are installed.
I. Local O&M software
Local O&M software includes FTP Client (Ftp.exe) and Telnet Client (Telnet.exe). The
two programs are both self-contained by Windows9x OS.
To realize the local maintenance, the maintenance console is connected through
crossover network cables to BTS via the Ethernet port that is in the Micro-bts
Base-band Processing Module (MBPM) maintenance window. The user thus can
issue O&M commands through the local maintenance console to maintain the
BTS3601C.
Software Installation & System Commissioning
0
错误表格结果无效
II. Remote O&M software
The remote O&M software comprises the software for the BAM server and the Client.
Among which, the Client software is composed of three parts: BSC Client, BTS3612
Client and BTS3601C Client. The remote O&M software described in this manual
refers to BTS3601C Client.
2.2 Installing Local O&M Software
2.2.1 Operational Environment
I. Hardware environment
Basic hardware configuration of the WS (desk-top computer):
l Pentium 100 CPU
l One 500Mbyte hard disk
l One 8Mbyte memory
l One integrated network card
2-1
Installation Manual
iSiteC BTS3601C CDMA Base Station
II. Software configuration
Windows 95 or Windows 98.
2.2.2 Conditions
For the normal operation of the local maintenance console, the following conditions
should be met:
1) The hardware environment are ready;
2) Windows9x OS can operate normally;
3) Windows9x installation files and network card driver (provided by the original
manufacturer) are furnished.
2.2.3 Network Configuration
This involves the installation and configuration of the network card and the TCP/IP.
The configuration is performed through the functional items of "Add new hardware"
and "Network" in turn on the "Control Panel" of the computer.
Software Installation & System Commissioning
0
错误表格结果无效
The IP address of the maintenance console should be in the same network segment
as that of BTS3601C MBPM network port. In addition, the address should be unique
in the IP addresses of the network equipment.
The connection sequence of network cables (crossover cable) at the network port is
shown in Figure 2-1.
Green
Green
Green and white
Yellow and white
Green and white
Yellow and white
Blue
Blue
RJ45
RJ45
Blue and white
Yellow
Blown and white
Blue and white
Yellow
Blown and white
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Blown
Blown
Yellow and white
Yellow
Green and white
Yellow and white
Yellow
Green and white
Blue
Blue
RJ45
RJ45
3
3
6
6
1
1
4
4
5
5
2
2
7
7
8
8
Blue and white
Green
Blown and white
Blue and white
Green
Blown and white
Blown
Blown
Figure 2-1 Connection sequence of crossover network cables
2-2
Installation Manual
iSiteC BTS3601C CDMA Base Station
2.2.4 Software Installation and Instructions
Since Local O&M software (Ftp.exe and Telnet.exe) is self-contained by Windows9x,
there is no need for extra installation.
To run Ftp/Telnet, click [Start/Run] in the system menu of the computer, and input "ftp
xxx.xxx.xxx.xxx"/"telnet xxx.xxx.xxx.xxx" into the dialogue box of [Run].
"xxx.xxx.xxx.xxx" is the IP address of MBPM network port. Ftp/Telnet is then started
for you to log in to the MBPM.
Software Installation & System Commissioning
0
错误表格结果无效
2.3 Installing Remote O&M Software
2.3.1 Operational Environment
The remote O&M software (referring to the BTS3601C Client software here) should
be installed to the same computer together with BSC Client and BTS3612 Client.
2.3.2 Conditions
1) Make sure the computer is installed with only the software necessary for the
system. Otherwise, there may be operational conflicts that may affect the normal
operation of the Client software. Moreover, make sure that a nice and stable
network hardware environment has been established.
2) Obtain from Huawei the complete set of installation files and read-me files, as
well as a legal product serial number.
3) BTS3601C Client software should be insta lled only after the corresponding BSC
Client and BTS3612 Client have been installed. Before installation, please make
sure that the versions of the three kinds of software are consistent.
2.3.3 Software Installation and Instructions
The BSC Client and BTS3612 Client (both are of the matching versions) should have
been installed first (for instructions, please refer to the corresponding parts in
BSC/BTS3612 installation manuals). After that, to install BTS3601C Client software,
the procedures include:
I. Starting SETUP.EXE
After inserting the installation disk into the disk drive, different alternatives are
provided for:
l If auto execution has been set for the system, the program will be started then.
l Or, you should click [Start/Run] in the system menu and key in "SETUP" and the
corresponding driver icon and path, and press <Enter>.
2-3
Installation Manual
iSiteC BTS3601C CDMA Base Station
l You can also click [SETUP.EXE] in the Resource Manager to run the program.
l You can copy the files in the installation disk to the hard disk and run them.
The initial installation interface as shown in Figure 2-2 will then pop up.
Software Installation & System Commissioning
0
错误表格结果无效
Figure 2-2 Initial installation interface
Click <Next> to continue (or click <Cancel> to exit the installation).
II. License agreement and installation instructions
The [Software License Agreement] will pop up as shown in Figure 2-3. After reading it
carefully, click <Yes> to accept it and continue (or <No> to exit the installation).
2-4
Installation Manual
iSiteC BTS3601C CDMA Base Station
Software Installation & System Commissioning
0
错误表格结果无效
Figure 2-3 Software license agreement interface
The installation wizard will guide you how to install the software step by step, as
shown in Figure 2-4. It may contain some latest installation information not given in
this manual. Read the information carefully, then click <Next> to continue.
Figure 2-4 Interface of system installation instructions
2-5
Installation Manual
iSiteC BTS3601C CDMA Base Station
III. Confirming the installation information
You are required to confirm the installation information as shown in Figure 2-5 before
copying files.
If you want to change the installation information, please click <Back> to return to the
previous step. Otherwise, click <Next> to continue.
Software Installation & System Commissioning
0
错误表格结果无效
Figure 2-5 Confirming the installation information
&
Note:
The default installation path for BTS3601C Client software is D:\AirBridge, the same as that of BSC
Client and BTS3612 Client. If the installation path of BSC/BTS3612 Client has been changed, the
installation program of BTS3601C Client will automatically find the new one.
IV. Completing the installation
After confirming the installation information, the installation program will start copying
files. In the process of file copying, the installation program will show such information
including overall progress, available disk space, available memory and progress of
individual file copying.
Upon the completion of the installation, the window [Setup Complete] as shown in
Figure 2-6 will pop up.
2-6