HPE P9R55A Getting Started Guide

QuickSpecs
HPE G2 Metered Power Distribution Units

Overview

Page 1
Setting new standards for reliable power distribution and metering
HPE Advanced Series G2 Metered PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate (billing grade accuracy) power distribution Standard, Advanced, and Enterprise racks (and compatible with other industry guarant t
A major concern for IT administrators and facility managers is their ability to quic in their IT racks
this problem by, first, offering a wide range of models and mounting options that promote flexible power configuration in efficiently utilize rack space while placing access to power where you need it most in the rack with features such as color power cables in the rear of the rack
HPE G2 Metered PDU features to maintain older switch solution configurations that provide up to 48 power outlets while minimizing physical cable solution for monitoring the environmental elements (temperature, humidity, and leakage)
HPE IEC Locking Power Cords are
provide secure cable retention to both the PDU and target device are not dislodged during a service ev issues that lead to power
Why
that promote efficient use of space in the rack and provide flexibility in how
and metering solution for your racks. Designed for use with HPE
-standard server racks), HPE G2 Metered PDUs
ee a compatible fit and reliable operation backed by a 3 year warranty. HPE G2 Metered PDUs are also rated for operating
emperatures up to 60°C, adding an increased level of operational reliability for power distribution in IT racks.
kly diagnose and service power related problems
. The HPE G2 PDU portfolio addresses
IT racks. Vertical, Horizontal, and True 0U mounting, give you the flexibility to
. Serviceability is further enhanced
-coded outlets and low-profile form factors, allowing for simple and quick access to IT equipment and .
are also directly focused on other pain points in the data center. 1Gb Ethernet alleviates the need
s that have been traditionally required for PDU network connectivity. High-density outlet
in a full-height vertical form factor allow for simple access to power in the rack
requirements. Support for up to eight sensors per PDU provides a cost-effective and exhaustive
in both the front and rear of the rack.
a new supported option available for most HPE G2 PDUs. The IEC Locking Power Cords
HPE Metered PDUs?
HPE Foundation Care services purchased for server and storage products, such as extended warranties and premium
support services, extend to our PDU products free of charge when purchased together.
HPE guarantees 100% compatibility between its Rack and Power Infrastructure products and its industry-standard
compute, storage, and networking solutions, backed with a 3-year warranty for all G2 Metered PDU models.
HPE offers multiple Metered PDU form factors
each PDU can be mounted and configured with cables.
-related downtime.
ent. HPE’s IEC Locking Power Cords provide a safe and secure solution against the common
, protecting against vibration during shipping and ensuring that cables
QuickSpecs
HPE G2 Metered Power Distribution Units

Models

Page 2
100-120V Input, Single Phase, North America/Japan
HPE G2 Metered 1.9 kVA/IEC C20 Detachable 16A/120V Outlets (8) 5-20R/1U Horizontal NA/JP PDU
P9R45A
HPE G2 Metered 1.9kVA/IEC C20 Detachable 16A/120V Outlets (16) 5-20R/Vertical NA/JP PDU
P9R46A
HPE G2 Metered 2.8kVA/L5-30P 24A/120V Outlets (24) 5-20R/Vertical NA/JP PDU
P9R48A
HPE G2 Metered 2.8kVA/L5-30P 24A/120V Outlets (16) 5-20R/2U Horizontal NA/JP PDU
P9R49A
NOTE: Models P9R45A and P9R46A include a C19 to NEMA 5-15 detachable input power cord.
100-240V Input, Single Phase, Worldwide
HPE G2 Metered 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (12) C13/1U Horizontal WW PDU
P9R50A
NOTE: Worldwide models do not include an input power cord. Please go to the Related Options section and select the appropriate input power cord for your geographic location.
200-208V Input, Single Phase, North America/Japan
HPE G2 Metered Modular 4.9kVA/L6-30P 24A/208V Outlets (6) IEC C19/1U Horizontal NA/JP PDU
P9R51A
HPE G2 Metered 4.9kVA/L6-30P 24A/208V Outlets (12) C13, (4) C19/2U Horizontal NA/JP PDU
P9R52A
HPE G2 Metered 4.9kVA/L6-30P 24A/208V Outlets (32) C13, (6) C19/Vertical NA/JP PDU
P9R53A
HPE G2 Metered 8.3kVA/CS8265C 40A/208V Outlets (30) C13, (6) C19/Vertical NA/JP PDU
P9R57A
HPE G2 Metered Modular 8.3kVA/CS8265C 40A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9R77A
200-208V Input, Three Phase, North America/Japan
HPE G2 Metered 3Ph 8.6kVA/L15-30P 24A/208V Outlets (18) C13, (6) C19/Vertical NA/JP PDU
P9R58A
HPE G2 Metered 3Ph 8.6kVA/L21-30P 24A/208V Outlets (30) C13, (6) C19, (2) 5-20R/Vertical NA/JP PDU
P9R59A
HPE G2 Metered Modular 3Ph 8.6kVA/L15-30P 24A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9R78A
HPE G2 Metered 3Ph 10kVA/CS8365C 35A/208V Outlets (30) C13, (6) C19/Vertical NA/JP PDU
P9R60A
HPE G2 Metered Modular 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9R80A
HPE G2 Metered 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (18) C13, (6) C19/Vertical NA/JP PDU
P9R82A
HPE G2 Metered 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (36) C13, (12) C19/Vertical NA/JP PDU
P9R83A
HPE G2 Metered 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (12) C13 (12) C19/Vertical NA/JP PDU
P9R86A
NOTE: Models P9R82A and P9R83A are high density models that have circuit breakers on the back side of the unit.
220-240V Input, Single Phase, International
HPE G2 Metered Modular 7.3kVA/60309 3-Wire 32A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9R54A
HPE G2 Metered 7.3kVA/60309 3-Wire 32A/230V Outlets (12) C13, (4) C19/2U Horizontal INTL PDU
P9R55A
HPE G2 Metered 7.3kVA/60309 3-Wire 32A/230V Outlets (32) C13, (6) C19/Vertical INTL PDU
P9R56A
220-240V Input, Three Phase, International
HPE G2 Metered 3Ph 11kVA/60309 5-Wire 16A/230V Outlets (36) C13, (6) C19/Vertical INTL PDU
P9R61A
HPE G2 Metered Modular 3Ph 11kVA/60309 5-Wire 16A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9R79A
HPE G2 Metered Modular 3Ph 22kVA/60309 5-Wire 32A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9R81A
HPE G2 Metered 3Ph 22kVA/60309 5-Wire 32A/230V Outlets (18) C13, (6) C19/Vertical INTL PDU
P9R84A
HPE G2 Metered 3Ph 22kVA/60309 5-Wire 32A/230V Outlets (36) C13, (12) C19/Vertical INTL PDU
P9R85A
HPE G2 Metered 3Ph 22kVA/60309 5-Wire 32A/230V Outlets (12) C13 (12) C19/Vertical INTL PDU
P9R87A
NOTE: Models P9R84A and P9R85A are high density models that have circuit breakers on the back side of the unit.
QuickSpecs
HPE G2 Metered Power Distribution Units
Models
Page 3
Horizontal Form Factors
1U Horizontal WW Model (P9R50A)
1U Horizontal 120V Model (P9R45A)
QuickSpecs
HPE G2 Metered Power Distribution Units
Models
Page 4
1U Three-Phase Horizontal Model (P9R80A)
Vertical Form Factors
Vertical 120V Model (P9R46A)
Vertical Single Phase Model with 100-240V Output (P9R59A)