HPE P9Q63A Getting Started Guide

QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)

Overview

Page 1
Basic, reliable power distribution for your HPE IT solutions
HPE Standard Series G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for racks)
G2 Basic PDUs can operate in temperatures up to 60°C over
extended periods of time
HPE offers a range of PDU models with mounting options that promote flexible power configuration in racks. Vertical, Horizon and True 0U mounting, giv most. Serviceability is further enhanced with features such as color and quick access to IT equipment and power cables in the rear of the rack.
HPE IEC Locking Power Cord secure cable retention to both the PDU and target device against vibration during shipping dislodged during a service event that lead to power
Why HPE Basic PDUs?
can support True 0U mounting (between the RETMA rails), minimizing the need to use valuable
or installation with outlets facing front, rear or center of
support services, extend to our Basic PDU products free of charge when purchased together.
use with HPE Standard, Advanced, and Enterprise racks (and compatible with other industry-standard server
. Built with high-temperature grade premium components, HPE
and provide reliable operation backed by a 5 year warranty.
ing you the flexibility to efficiently utilize rack space while placing access to power where you need it
-coded outlets and low-profile form factors allowing for simple
s are a new supported option available for HPE G2 PDUs. The IEC Locking Power Cords provide
and ensuring that cables are not
. HPE’s IEC Locking Power Cords provide a safe and secure solution against the common issues
-related downtime.
All HPE G2 Basic PDUs are rated for operating temperatures up to 60°C (or 140°F).
Low-profile PDU form factors providing enhanced IT serviceability in the back of the rack while adhering to the rack keep
out zone.
HPE G2 PDUs with IEC C19 and C13 receptacles have integrated cord retention.
HPE G2 PDUs have color-coded receptacles to easily distinguish between the different load segments/phases.
High-density vertical form factor providing 24 outlets in a half-height (22U) and 48 outlets in a full-height (42U).
HPE offers multiple PDU form factors that promote efficient use of space in the rack and provide flexibility in mounting
and configuration.
HPE 1U Horizontal PDUs
U space in racks for power distribution.
Vertical HPE G2 PDUs use a button mounting system that allows f
rack.
HPE guarantees 100% compatibility between its Rack and Power Infrastructure products and its industry-standard
compute, storage, and networking solutions, backed with a 5-year warranty for all HPE G2 Basic PDU models.
HPE Foundation Care services purchased for server and storage products, such as extended warranties and premium
tal,
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)

Models

Page 2
100-120V Input, Single Phase, North America/Japan
HPE G2 Basic 1.9kVA/IEC C20 Detachable 16A/120V Outlets (12) 5-20R/1U Horizontal NA/JP PDU
P9Q31A
HPE G2 Basic 1.9kVA/IEC C20 Detachable 16A/120V Outlets (16) 5-20R/Vertical NA/JP PDU
P9Q32A
HPE G2 Basic Modular 2.8kVA/L5-30P 24A/120V Outlets (6) IEC C19/1U Horizontal NA/JP PDU
P9Q33A
HPE G2 Basic 2.8kVA/L5-30P 24A/120V Outlets (22) 5-20R/Vertical NA/JP PDU
P9Q34A
HPE G2 Basic 2.8kVA/L5-30P 24A/120V Outlets (16) 5-20R/2U Horizontal NA/JP PDU
P9Q35A
NOTE: Models P9Q31A and P9Q32A include a C19 to NEMA 5-15 input power cord.
200-240V Input, Single Phase, Worldwide
HPE G2 Basic Modular 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (2) C19/1U Horizontal WW PDU
P9Q36A
HPE G2 Basic 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (12) C13/1U Horizontal WW PDU
P9Q37A
HPE G2 Basic 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (20) C13 (2) C19/Vertical WW PDU
P9Q38A
HPE G2 Basic 9.2kVA/50A Term Block 40A/208V Outlets (30) C13 (6) C19/Vertical WW PDU
P9Q49A
NOTE: Worldwide models do not include an input power cord. Please go to the Related Options section and select
the appropriate input power cord for your geographic location.
200-208V Input, Single Phase, North America/Japan
HPE G2 Basic Modular 4.9kVA/L6-30P 24A/208V Outlets (6) IEC C19/1U Horizontal NA/JP PDU
P9Q39A
HPE G2 Basic 4.9kVA/L6-30P 24A/208V Outlets (12) C13/1U Horizontal NA/JP PDU
P9Q40A
HPE G2 Basic 4.9kVA/L6-30P 24A/208V Outlets (20) C13/Vertical NA/JP PDU
P9Q41A
HPE G2 Basic 4.9kVA/L6-30P 24A/208V Outlets (36) C13 (6) C19/Vertical NA/JP PDU
P9Q42A
HPE G2 Basic Modular 8.3kVA/CS8265C 40A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9Q47A
HPE G2 Basic 8.3kVA/CS8265C 40A/208V Outlets (30) C13 (6) C19/Vertical NA/JP PDU
P9Q48A
200-208V Input, Three Phase, North America/Japan
HPE G2 Basic Modular 3Ph 8.6kVA/L15-30P 24A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9Q52A
HPE G2 Basic 3Ph 8.6kVA/L15-30P 24A/208V Outlets (18) C13/Vertical NA/JP PDU
P9Q54A
HPE G2 Basic 3Ph 8.6kVA/L21-30P 24A/208V Outlets (24) C13 (3) C19 (3) 5-20R/Vertical NA/JP PDU
P9Q55A
HPE G2 Basic 3Ph 8.6kVA/L15-30P 24A/208V Outlets (30) C13 (6) C19/Vertical NA/JP PDU
P9Q53A
HPE G2 Basic 3Ph 10kVA/CS8365C 28A/208V Outlets (36) C13 (6) C19/Vertical NA/JP PDU
P9Q56A
HPE G2 Basic Modular 3Ph 14.4kVA/CS8365C 40A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9Q59A
HPE G2 Basic Modular 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (6) C19/1U Horizontal NA/JP PDU
P9Q60A
HPE G2 Basic 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (18) C13 (6) C19/Vertical NA/JP PDU
P9Q61A
HPE G2 Basic 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (36) C13 (12) C19/Vertical NA/JP PDU
P9Q62A
NOTE: P9Q61A and P9Q62A are high density models with circuit breakers on the back side of the unit.
220-240V Input, Single Phase, International
HPE G2 Basic Modular 7.3kVA/60309 3-wire 32A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9Q43A
HPE G2 Basic 7.3kVA/60309 3-wire 32A/230V Outlets (12) C13/1U Horizontal INTL PDU
P9Q44A
HPE G2 Basic 7.3kVA/60309 3-wire 32A/230V Outlets (20) C13/Vertical INTL PDU
P9Q45A
HPE G2 Basic 7.3kVA/60309 3-wire 32A/230V Outlets (36) C13 (6) C19/Vertical INTL PDU
P9Q46A
HPE G2 Basic 11kVA/60309 63A 3-wire 48A/230V Outlets (30) C13 (6) C19/Vertical INTL PDU
P9Q50A
HPE G2 Basic Modular 14.4kVA/60309 63A 3-wire 48A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9Q51A
220-240V Input, Three Phase, International
HPE G2 Basic 3Ph 11kVA/60309 5-wire 16A/230V Outlets (36) C13 (6) C19/Vertical INTL PDU
P9Q58A
HPE G2 Basic Modular 3Ph 11kVA/60309 5-wire 16A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9Q57A
HPE G2 Basic Modular 3Ph 22kVA/60309 5-wire 32A/230V Outlets (6) C19/1U Horizontal INTL PDU
P9Q63A
HPE G2 Basic 3Ph 22kVA/60309 5-wire 32A/230V Outlets (18) C13 (6) C19/Vertical INTL PDU
P9Q64A
HPE G2 Basic 3Ph 22kVA/60309 5-wire 32A/230V Outlets (36) C13 (12) C19/Vertical INTL PDU
P9Q65A
NOTE: P9Q64A and P9Q65A are high density models with circuit breakers on the back side of the unit.
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Models
Page 3
Horizontal Form Factors
1U Horizontal– P9Q47A
Top view
Elevated view
2U Horizontal – P9Q35A
Top view
Elevated view
Vertical Form Factors
Quarter-Height – P9Q37A
Top view
Elevated view
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Models
Page 4
Half-Height – P9Q61A
Top view
Elevated view
Mid-Height – P9Q42A
Top view
Elevated view
Full-Height – P9Q65A
Top view
Elevated view
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)

Key Features

Page 5
Compatibility
Designed specifically for use with HPE rack enclosures and IT solutions but can work with most 3
rd
party IT racks
Reliability/Durability
5-year warranty with free service/support upgrades matching server purchase
Usability/Serviceability
Wide range of mounting options including vertical, 1U/2U horizontal, and True 0U
Multiple extension bar options that inexpensively expand outlet configurations
Safety/Security
Optional dual-locking power cords that secure both power connections
True 0U Mounting
All HPE Horizontal PDUs can be installed in any U position in your rack. However, HPE 1U Horizontal PDUs have a unique architecture designed specifically for data center customers who want to maximize space effic
These models can be installed in the 0U space between the RETMA rails on
HPE Advanced and Enterprise Series racks
Modular PDU
HPE Basic Modular PDUs combine True 0U and 1U Horizontal mounting support with the capability of adding extension bars to expand access to power in the back of the rack. Extension Bars mount directly
High reliability at elevated operating temperature levels (up to 60°C)
Modular PDU options supporting True 0U mounting between the RETMA rails of the rack High-density vertical power outlet configurations with up to 48 outlets on a single PDU Full range of single and three phase input and output power capabilities
1.9kVA to 22kVA power distribution to meet the needs of both small and large data centers Built-in three-sided button mounting system supporting flexible installations Low-profile PDU form factors providing enhanced IT serviceability in the back of the rack Color coded receptacles and circuit breaker banks to easily identify specific outlets
Support for integrated individual power cord retention
iencies in the rack.
(see diagram below)
QuickSpecs
HPE Standard Serie
s
G2 Basic Power Distribution Units (PDU)
Key Features
Page 6
Form Factor
to the frame of the rack in multiple locations allowing you the flexibility of placing access to power where it is needed most customize the outlet configurations you require.
HPE PDU Extension Bar Options
HPE PDU extension bar options help expand the availability of power in the rear of the rack. Each extension bar Locking Power Cords (for C13/C14 and C19/C20 to compatible with previous generation PDU models that offer C20 outlets (locking feature only supported on new G2 PDU models). See the Related Options section for more information on G2 Extension Bar models.
High-Density Vertical PDU Models
High-density vertical PDU models provide 24 outlets in a half-height (22U) form factor and 48 outlets in a full the PDU an
without significantly impacting the height
(profile) of the PDU. models.
IEC Locking Power Cords
HPE G2 PDU models support optional IEC Locking Power Cords with an integrated locking technology on both ends of the cable. Locking Power Cord connections IEC Locking Power Cord has been included with each PDU model that supports either a C13 and/or C19 outlet.
Color-Coded Outlets
All HPE G2 PDU models now include color-coded outlets. Highly visible from the rear of the rack, color­coding helps to easily and clearly identify outlets to simpl configuring and maintaining power for your IT equipment.
Rated for High Operating Temperatures
HPE G2 PDUs are rated for operating temperatures up to 60°C (or 140°F). HPE G2 PDUs are designed with high temperature rated premium components and construction that support increased reliability levels at elevated temperatures.
5-Year Warranty
HPE G2 Basic PDU models are supported with a 5-year warranty. The HPE Foundation Care Extension p servers, storage, and networking solutions
Additional information regarding worldwide limited warr
http://h17007.www1.hpe.com/us/en/enterprise/servers/warranty/index.aspx#.V-10xE3rvbq
(see diagram above). Multiple extension bar options are available to help you
includes a locking input power cord that connects to the PDU and supports HPE’s new IEC
connections). HPE PDU extension bars can be added
Horizontal and Vertical PDU models with available C20 outlets for additional outlets and are
-height (42U) form factor. This density is achieved by placing the power receptacles on one side of d access to the circuit breakers on the opposite side
See the Model Matrix section for more information on high-density Vertical PDU
s are available for both C13/14 and C19/20 power
, include multiple cable length options, and can be purchased in single or six-pack kits. One
ify cabling and power phase balancing when
rogram provides additional support and services for your PDU models when purchased with HPE
at no additional charge.
anty and technical support is available at:
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)

Related Options

Page 7
Related Options
Extension Bars
HPE G2 IEC C20 Input/(8) C13 Expansion Outlets/PDU Extension Bar Kit
P9Q66A
HPE G2 IEC C20 Input/(4) C13 (2) C19 Expansion Outlets/PDU Extension Bar Kit
P9Q67A
HPE G2 IEC C20 Input/(7) 5-20R Expansion Outlets/PDU Extension Bar Kit
P9Q68A
NOTE: All kits include 2 extension bars with a locking C19 input power cord (1.8m).
IEC Locking Power Cords
HPE C13 - C14 WW 250V 10Amp 0.7m Black Locking Power Cord
Q0P67A
HPE C13 - C14 WW 250V 10Amp 0.7m Black 6-pack Locking Power Cord
Q0Q02A
HPE C13 - C14 WW 250V 10Amp 1.4m Black Locking Power Cord
Q0P68A
HPE C13 - C14 WW 250V 10Amp 1.4m Black 6-pack Locking Power Cord
Q0Q03A
HPE C13 - C14 WW 250V 10Amp 2m Black Locking Power Cord
Q0P69A
HPE C13 - C14 WW 250V 10Amp 2m Black 6-pack Locking Power Cord
Q0Q04A
HPE C13 - C14 WW 250V 10Amp 3m Black Locking Power Cord
Q0P70A
HPE C13 - C14 WW 250V 10Amp 3m Black 6-pack Locking Power Cord
Q0Q05A
HPE C19 - C20 WW 250V 16Amp 0.7m Black Locking Power Cord
Q0R19A
HPE C19 - C20 WW 250V 16Amp 0.7m 6-pack Black Locking Power Cord
Q0R15A
HPE C19 - C20 WW 250V 16Amp 1.2m Black Locking Power Cord
Q0P71A
HPE C19 - C20 WW 250V 16Amp 1.2m 6-pack Black Locking Power Cord
Q0R16A
HPE C19 - C20 WW 250V 16Amp 2m Black Locking Power Cord
Q0P72A
HPE C19 - C20 WW 250V 16Amp 2m 6-pack Black Locking Power Cord
Q0R17A
HPE C19 - C20 WW 250V 16Amp 2.5m Black Locking Power Cord
Q0P73A
HPE C19 - C20 WW 250V 16Amp 2.5m 6-pack Black Locking Power Cord
Q0R18A
NOTE: HPE Locking Power Cords support HPE G2 Standard Series Basic PDUs with
C13/14 or C19/20 power receptacles.
IEC Standard Power Cords
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord
A0K03A
HP C13 - C14 WW 250V 10Amp 0.7m Jumper Cord
142257-B28
HP C13 - C14 WW 250V 10Amp 1.4m Jumper Cord
142257-006
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord
A0K04A
HP C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord
142257-007
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord
A0K02A
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord
AF573A
HP C13 - C14 WW 250V 10Amp 2.5m Jumper Cord
142257-002
HP C13 - C14 WW 250V 10Amp 3.0m Jumper Cord
142257-003
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord
A0K06A
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
AF590A
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord
AF575A
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord
AF574A
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord
295633-B22
HP 200-250V 10A C15 to C14 .76m Jumper Cable
E7807A
Country Power Cords
HP C13 - NEMA 5-15P US/CA 110V 10Amp 1.83m Power Cord
AF556A
HP C19 - NEMA L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord
AF593A
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord
AF592A
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord
AF584A
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord
AF582A
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord
AF583A
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord
AF577A
-Specific
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Related Options
Page 8
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord
AF581A
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord
AF576A
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord
AF580A
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord
AF579A
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord
359615-031
HP 240 VAC 4.5M Unterminated End NA Power Cord
E7806A
HPE Mounting Brackets
HPE Vertical PDU 10K G2 Mounting Kit
H6L32A
NOTE: This kit allows for HPE G2 Basic PDU vertical models to be mounted in HPE 10000 G2 series racks and in the HPE Standard Series rack.
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Model Matrix
– Form Factor/Mounting Options
Page 9
Mounting options for Horizontal 1U and 2U PDU models
Model
W x H x D
Unit Weight
U Height
Horizontal Mounting
True 0U Mounting
P9Q31A
17.461 x 1.633 x 2.087 in
2.2 lbs.
1U  
P9Q33A
17.461 x 1.713 x 7.772 in
9.3 lbs.
1U  
P9Q35A
17.461 x 3.425 x 1.713 in
10.2 lbs.
2U  n/a
P9Q36A
17.461 x 1.633 x 2.087 in
2.0 lbs.
1U  
P9Q37A
17.461 x 1.633 x 2.087 in
2.2 lbs.
1U
P9Q39A
9.7 lbs.
P9Q40A
17.461 x 1.713 x 7.772 in
10.2 lbs.
1U
P9Q43A
17.461 x 1.713 x 7.772 in
9.3 lbs.
1U
P9Q44A
17.461 x 1.713 x 7.772 in
8.7 lbs.
1U
17.461 x 1.713 x 7.772 in
12.1 lbs.
1U
P9Q51A
17.461 x 1.713 x 7.772 in
12.5 lbs.
1U  
P9Q52A
17.461 x 1.713 x 7.772 in
9.5 lbs.
1U  
P9Q57A
17.461 x 1.633 x 2.087 in
5.1 lbs.
1U  
P9Q59A
17.461 x 1.713 x 7.772 in
18.5 lbs.
1U  
P9Q60A
17.461 x 1.713 x 7.772 in
19.6 lbs.
1U  
P9Q63A
17.461 x 1.713 x 7.772 in
10.6 lbs.
1U
Mounting options for Vertical PDU models in HPE Advanced and Enterprise racks (1075mm depth)
Maximum PDUs Supported Per Side
22U
36U
42U
48U
P9Q31A
17.461 x 1.633 x 2.087 in
2.2 lbs.
Quarter-Height
2 2 6
6
P9Q32A
2.047 x 32.165 x 2.087 in
4.4 lbs.
Half-Height
2 2 4
4
P9Q34A
2.047 x 32.165 x 2.087 in
8.4 lbs.
Half-Height
2 2 4
4
P9Q36A
17.461 x 1.633 x 2.087 in
2.0 lbs.
Quarter-Height
2 2 6
6
P9Q37A
17.461 x 1.633 x 2.087 in
2.2 lbs.
Quarter-Height
2 2 6
6
P9Q38A
2.047 x 32.165 x 2.087 in
4.5 lbs.
Half-Height
2 2 4
4
P9Q41A
2.047 x 32.165 x 2.087 in
8.1 lbs.
Half-Height
2 2 4
4
P9Q42A
2.047 x 58.661 x 2.087 in
12.0 lbs.
Mid-Height
n/a 2 2
2
P9Q45A
2.047 x 32.165 x 2.087 in
7.4 lbs.
Half-Height
2 2 4
4
P9Q46A
2.047 x 58.661 x 2.087 in
11.1 lbs.
Mid-Height
n/a 2 2
2
P9Q48A
2.047 x 58.661 x 2.087 in
13.2 lbs.
Mid-Height
n/a 2 2
2
P9Q49A
2.047 x 58.661 x 2.087 in
10.0 lbs.
Mid-Height
n/a 2 2
2
P9Q50A
2.047 x 58.661 x 2.087 in
14.7 lbs.
Mid-Height
n/a 2 2
2
P9Q53A
2.047 x 58.661 x 2.087 in
13.5 lbs.
Mid-Height
n/a 2 2
2
P9Q54A
2.047 x 32.165 x 2.087 in
9.3 lbs.
Half-Height
n/a 2 4
4
P9Q55A
2.047 x 58.661 x 2.087 in
14.0 lbs.
Mid-Height
n/a 2 2
2
P9Q56A
2.047 x 68.898 x 2.087 in
17.4 lbs.
Full-Height
n/a
n/a 2 2
P9Q57A
17.461 x 1.633 x 2.087 in
5.1 lbs.
Quarter-Height
2 2 6
6
P9Q58A
2.047 x 58.661 x 2.087 in
9.9 lbs.
Mid-Height
n/a 2 2
2
P9Q61A*
2.047 x 36.024 x 4.409 in
21.3 lbs.
Half-Height
1 1 2
2
P9Q62A*
2.047 x 71.654 x 4.409 in
27.1 lbs.
Full-Height
n/a
n/a 1 1
P9Q64A*
2.047 x 36.024 x 4.409 in
12.3 lbs.
Half-Height
1 1 2
2
P9Q65A*
2.047 x 71.654 x 4.409 in
20.3 lbs.
Full-Height
n/a
n/a 1 1
* HPE high density model mounts on its side with outlets facing the back of the rack.
17.461 x 1.713 x 7.772 in
1U
P9Q47A
Model W x H x D Unit Weight Vertical Height
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Model Matrix
– Input Power
Page 10
NOTE: HPE G2 Advanced and Enterprise 1200mm deep racks include an extra set (2) of PDU trays in the rear of the rack enabling support of up to 2x the number of PDUs listed above for 1075mm deep racks.
Power
Phase
Input Voltage
Range
Input
Current
Circuit
Breakers
Input Plug
Type
Input Cord
Length
P9Q31A
NA/JP
Single
100 - 120V
16A
None
5-15P
12’ (Detachable)
P9Q32A
NA/JP
Single
100 - 120V
16A
None
5-15P
12’ (Detachable)
P9Q33A
NA/JP
Single
100 - 120V
24A
(2) 1-pole, 20A
L5-30P
12’
P9Q34A
NA/JP
Single
100 - 120V
24A
(2) 1-pole, 20A
L5-30P
10’
P9Q35A
NA/JP
Single
100 - 120V
24A
(2) 1-pole, 20A
L5-30P
12’
P9Q36A
WW
Single
100 - 240V
16A
None
C20 Inlet
Detachable
P9Q37A
WW
Single
100 - 240V
16A
None
C20 Inlet
Detachable
P9Q38A
WW
Single
100 - 240V
16A
None
C20 Inlet
Detachable
P9Q39A
NA/JP
Single
200 - 208V
24A
(2) 2-pole 20A
L6-30P
12’
P9Q40A
NA/JP
Single
200 - 208V
24A
(2) 2-pole 20A
L6-30P
12’
P9Q41A
NA/JP
Single
200 - 208V
24A
(2) 2-pole 20A
L6-30P
10’
P9Q42A
NA/JP
Single
200 - 208V
24A
(2) 2-pole 20A
L6-30P
10’
50A Terminal
Block
P9Q50A
INTL
Single
220 - 240V
48A
(3) 1-pole, 16A
IEC 63A, 1ph
10’
P9Q51A
INTL
Single
220 - 240V
63A
(6) 1-pole, 16A
IEC 63A, 1ph
12’
P9Q52A
NA/JP
Three
200 - 208V
24A
(3) 2-pole, 20A
L15-30P
12’
P9Q53A
NA/JP
Three
200 - 208V
24A
(3) 2-pole, 20A
L15-30P
10’
P9Q54A
NA/JP
Three
200 - 208V
24A
(3) 2-pole, 20A
L15-30P
10’
P9Q55A
NA/JP
Three
120/208V
24A
(3) 2-pole, 20A
L21-30P
10’
P9Q56A
NA/JP
Three
200 - 208V
28A
(3) 2-pole, 20A
CS8365C
10’
P9Q57A
INTL
Three
200 – 240V/346 – 415V
16A
None
IEC 16A, 3ph
12’
P9Q58A
INTL
Three
200 – 240V/346 – 415V
16A
None
IEC 16A, 3ph
10’
P9Q59A
NA/JP
Three
200 - 208V
40A
(6) 2-pole, 20A
CS8365C
12’
P9Q60A
NA/JP
Three
200 - 208V
48A
(6) 2-pole, 20A
IEC 60A, 3ph
12’
P9Q61A
NA/JP
Three
200 - 208V
48A
(6) 2-pole, 20A
IEC 60A, 3ph
10’
P9Q62A
NA/JP
Three
200 - 208V
48A
(6) 2-pole, 20A
IEC 60A, 3ph
10’
P9Q63A
INTL
Three
200 – 240V/346 – 415V
32A
(6) 1-pole, 16A
IEC 32A, 3ph
12’
P9Q64A
INTL
Three
200 – 240V/346 – 415V
32A
(6) 1-pole, 16A
IEC 32A, 3ph
10’
P9Q65A
INTL
Three
200 – 240V/346 – 415V
32A
(6) 1-pole, 16A
IEC 32A, 3ph
10’
NOTE: All Input Circuit Ratings for NA/JP models have been de-rated according to NEC requirements.
Nominal Input Voltage Ratings used for calculating output power are as follows:
220 – 240V: 230V
Model Region
P9Q43A INTL Single 220 - 240V 32A (2) 1-pole, 16A IEC 32A, 1ph 12’
P9Q44A INTL Single 220 - 240V 32A (2) 1-pole, 16A IEC 32A, 1ph 12’
P9Q45A INTL Single 220 - 240V 32A (2) 1-pole, 16A IEC 32A, 1ph 10’
P9Q46A INTL Single 220 - 240V 32A (2) 1-pole, 16A IEC 32A, 1ph 10’
P9Q47A NA/JP Single 200 - 208V 40A (3) 2-pole, 20A CS8265C 12’
P9Q48A NA/JP Single 200 - 208V 40A (3) 2-pole, 20A CS8265C 10’
P9Q49A WW Single 200 - 208V 40A (3) 2-pole, 20A
100 – 120V: 120V
200 – 208V: 208V
100 – 240V: 230V
Detachable
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Mo
del Matrix – Input Power
Page 11
200 – 240V/346 – 415V: 230V
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)
Model Matrix
– Output Power
Page 12
Nominal
(kVA)
Output
Range
Support Extension Bar
Support Locking
Cord Options
P9Q31A
NA/JP
1.9
100-125V
(12)5-20R
n/a
n/a
P9Q32A
NA/JP
1.9
100-125V
(16)5-20R
n/a
n/a
P9Q33A
NA/JP
2.8
100-125V
(6)C19
P9Q34A
NA/JP
2.8
100-125V
(22)5-20R
n/a
n/a
P9Q35A
NA/JP
2.8
100-125V
(16)5-20R
n/a
n/a
P9Q36A
WW
3.6
100-240V
(2)C19
P9Q37A
WW
3.6
100-240V
(12)C13
n/a
P9Q38A
WW
3.6
100-240V
(20)C12, (2)C19
P9Q39A
NA/JP
4.9
200-240V
(6)C19
P9Q40A
NA/JP
4.9
200-240V
(12)C13
n/a
P9Q41A
NA/JP
4.9
200-240V
(20)C13
n/a
P9Q42A
NA/JP
4.9
200-240V
(36)C13, (6)C19
P9Q43A
INTL
7.3
220-240V
(6)C19
P9Q44A
INTL
7.3
220-240V
(12)C13
n/a
P9Q45A
INTL
7.3
220-240V
(20)C13
n/a
P9Q46A
INTL
7.3
220-240V
(36)C13, (6)C19
P9Q47A
NA/JP
8.3
200-240V
(6)C19
P9Q48A
NA/JP
8.3
200-240V
(30)C13, (6)C19
P9Q49A
WW
9.2
200-240V
(30)C13, (6)C19
P9Q50A
INTL
11
220-240V
(30)C13, (6)C19
P9Q51A
INTL
14.4
220-240V
(6)C19
P9Q52A
(6)C19
P9Q53A
(30)C13, (6)C19
P9Q54A
(18)C13
n/a
(24)C13, (3)C19, (3)5-
20R
P9Q56A
NA/JP
10
200-240V
(36)C13, (6)C19
P9Q57A
INTL
11
220-240V
(6)C19
P9Q58A
INTL
11
220-240V
(36)C13, (6)C19
P9Q59A
NA/JP
14.4
200-240V
(6)C19
P9Q60A
NA/JP
17.3
200-240V
(6)C19
P9Q61A
NA/JP
17.3
200-240V
(18)C13, (6)C19
P9Q62A
NA/JP
17.3
200-240V
(36)C13, (12)C19
P9Q63A
(6)C19
P9Q64A
(18)C13, (6)C19
P9Q65A
INTL
22
220-240V
(36)C13, (12)C19
NOTE: For more information on Extension Bar and Power Cord options, please see the Related Options section.
Model Region
Power
Voltage
Output
Receptacles
Options
Power
NA/JP 8.6 200-240V NA/JP 8.6 200-240V NA/JP 8.6 200-240V
P9Q55A NA/JP 8.6 120/208V
INTL 22 220-240V INTL 22 220-240V
QuickSpecs
HPE Standard Series
G2 Basic Power Distribution Units (PDU)

PDU Plugs

Page 13
3
Voltage Amps # Wires Plug Name
15 A 3 NEMA 5-15P
100-125 V
Single Phase
30 A 3 NEMA L5-30P
20 A 3 IEC C20
30 A 3 NEMA L6-30P
200-240 V
32 A 3 IEC 309 32A
Single Phase
50 A
CS8265C
Sample Plug Image
(color may vary by manufacturer)
200 - 208 V
NA/JPN
Three Phase
200 – 240 V and
346 – 415 V
INTL
Three Phase
63 A 3 IEC 309 63A
30 A 5 NEMA L15-30P
30 A 5 NEMA L21-30P
50 A 4 CS8365C
60 A 4 IEC 309 60A
16 A 5 IEC 309 16 A
32 A 5 IEC 309 32 A
Loading...