Hp XL250A GEN9 User Manual

Page 1
HP ProLiant XL250a Gen9 Server

Abstract

This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous
Part Number: 752037-004 August 2015 Edition: 4
Maintenance and Service Guide
energy levels and are familiar with weight and stability precautions for rack installations.
Page 2
© Copyright 2014, 2015 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Links to third-party websites take you outside the HP website. HP has no control over and is not responsible for information outside HP.com.
Microsoft® and Windows® are trademarks of the Microsoft group of companies.
Intel® Xeon® is a trademark of Intel Corporation in the U.S. and other countries.
UNIX® is a registered trademark of The Open Group.
MicroSD is a trademark or registered trademark of SD-3C in the United States, other countries or both.
NVIDIA, the NVIDIA logo, and NVIDIA Tesla are trademarks and/or registered trademarks of NVIDIA Corporation in the U.S. and other countries.
Page 3

Contents

Customer self repair ...................................................................................................................... 5
Parts only warranty service ............................................................................................................................ 5
Illustrated parts catalog ............................................................................................................... 15
Server system components ........................................................................................................................... 15
I/O module components ............................................................................................................................. 21
Removal and replacement procedures ........................................................................................... 25
Required tools ............................................................................................................................................ 25
Safety considerations .................................................................................................................................. 25
Preventing electrostatic discharge ...................................................................................................... 25
Symbols on equipment ...................................................................................................................... 25
Server warnings and cautions ............................................................................................................ 26
Preparation procedures ............................................................................................................................... 26
Power down the server ..................................................................................................................... 27
Remove the server ............................................................................................................................ 27
Remove the accelerator cages ........................................................................................................... 28
Remove the upper server tray ............................................................................................................ 28
Remove the upper server tray support bracket ..................................................................................... 29
Install the upper server tray support bracket ........................................................................................ 30
Install the upper server tray ............................................................................................................... 30
Remove the I/O module .................................................................................................................... 32
Install the server ............................................................................................................................... 33
Drive blank ................................................................................................................................................ 35
Drive ......................................................................................................................................................... 35
PCIe/FlexibleLOM I/O module .................................................................................................................... 36
PCIe/FlexibleLOM I/O module PCIe options ................................................................................................. 36
PCIe/FlexibleLOM I/O module FlexibleLOM options ..................................................................................... 37
HP Ethernet Dual 1Gb 1-port 364i Adapter and I/O module .......................................................................... 38
Dual FlexibleLOM riser options .................................................................................................................... 39
Accelerator (front) ...................................................................................................................................... 40
Accelerator (rear) ....................................................................................................................................... 41
Power expander board ............................................................................................................................... 43
Processor air baffle ..................................................................................................................................... 44
DIMMs ...................................................................................................................................................... 45
Rear PCIe riser board ................................................................................................................................. 47
PCIe riser board assembly ........................................................................................................................... 48
PCIe expansion board options ..................................................................................................................... 49
Cache module ........................................................................................................................................... 51
HP Smart Storage Battery option .................................................................................................................. 52
Drive cage assembly 1 ............................................................................................................................... 53
Drive cage assembly 2 ............................................................................................................................... 55
Front panel LED board assembly .................................................................................................................. 56
System battery ........................................................................................................................................... 58
Heatsink .................................................................................................................................................... 59
Processor................................................................................................................................................... 63
System board ............................................................................................................................................ 69
Contents 3
Page 4
Re-entering the server serial number and product ID ............................................................................. 74
HP Trusted Platform Module......................................................................................................................... 74
Troubleshooting .......................................................................................................................... 75
Troubleshooting resources ........................................................................................................................... 75
Diagnostic tools .......................................................................................................................... 76
Product QuickSpecs .................................................................................................................................... 76
HP iLO ...................................................................................................................................................... 76
Active Health System ........................................................................................................................ 77
HP ProLiant Pre-boot Health Summary ................................................................................................. 77
Integrated Management Log .............................................................................................................. 78
HP UEFI System Utilities............................................................................................................................... 78
Using HP UEFI System Utilities ........................................................................................................... 78
Embedded Diagnostics option ........................................................................................................... 79
Re-entering the server serial number and product ID ............................................................................. 79
HP Insight Diagnostics ................................................................................................................................ 80
HP Insight Diagnostics survey functionality .......................................................................................... 80
HP Insight Remote Support .......................................................................................................................... 80
USB support .............................................................................................................................................. 80
External USB functionality ................................................................................................................. 81
Automatic Server Recovery .......................................................................................................................... 81
Component identification ............................................................................................................. 82
Front panel components .............................................................................................................................. 82
Hot-plug drive numbering .................................................................................................................. 83
Front panel LEDs and buttons ....................................................................................................................... 83
Front panel LED power fault codes ..................................................................................................... 84
Hot-plug drive LED definitions ............................................................................................................ 85
System board components .......................................................................................................................... 85
DIMM slot locations .......................................................................................................................... 86
System maintenance switch ............................................................................................................... 87
Accelerator numbering ............................................................................................................................... 87
Power expander board components ............................................................................................................. 88
Expansion slot definitions ............................................................................................................................ 88
I/O module bay numbering ........................................................................................................................ 89
I/O module slot definitions ................................................................................................................ 89
Cabling ..................................................................................................................................... 91
Internal server cabling ................................................................................................................................ 91
Front panel LED board assembly cabling ............................................................................................ 91
Drive cabling ................................................................................................................................... 91
HP Smart Storage Battery cabling ...................................................................................................... 93
Accelerator option cabling ................................................................................................................ 94
Intra-tray signal cable routing ............................................................................................................ 94
SUV cable connectors ................................................................................................................................. 94
Specifications
Environmental specifications ........................................................................................................................ 96
Server specifications ................................................................................................................................... 96
............................................................................................................................. 96
Acronyms and abbreviations ........................................................................................................ 97
Documentation feedback ............................................................................................................. 99
Index ....................................................................................................................................... 100
Contents 4
Page 5

Customer self repair

HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts,
you will be charged for the travel and labor costs of this service.
Optional—Parts for which customer self repair is optional. These parts are also designed for customer
self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider. For the North American program, refer to the HP website (http://www.hp.com/go/selfrepair).

Parts only warranty service

Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only warranty service, HP will provide replacement parts free of charge.
For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:
Customer self repair 5
Page 6
Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP (http://www.hp.com/go/selfrepair).
Service de garantie "pièces seules"
Votre garantie limitée HP peut inclure un service de garantie "pièces seules". Dans ce cas, les pièces de rechange fournies par HP ne sont pas facturées.
Dans le cadre de ce service, la réparation des pièces CSR par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.
Customer self repair 6
Page 7
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP (http://www.hp.com/go/selfrepair).
Servizio di garanzia per i soli componenti
La garanzia limitata HP può includere un servizio di garanzia per i soli componenti. Nei termini di garanzia del servizio per i soli componenti, HP fornirà gratuitamente le parti di ricambio.
Per il servizio di garanzia per i soli componenti è obbligatoria la formula CSR che prevede la riparazione da parte del cliente. Se il cliente invece richiede la sostituzione ad HP, dovrà sostenere le spese di spedizione e di manodopera per il servizio.
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet.
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das
Customer self repair 7
Page 8
defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kurier-/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter (http://www.hp.com/go/selfrepair).
Parts-only Warranty Service (Garantieservice ausschließlich für Teile)
Ihre HP Garantie umfasst möglicherweise einen Parts-only Warranty Service (Garantieservice ausschließlich für Teile). Gemäß den Bestimmungen des Parts-only Warranty Service stellt HP Ersatzteile kostenlos zur Verfügung.
Für den Parts-only Warranty Service ist das CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet.
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:
Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a
HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos
componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No" en el catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no
Customer self repair 8
Page 9
enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente (http://www.hp.com/go/selfrepair).
Servicio de garantía exclusivo de componentes
La garantía limitada de HP puede que incluya un servicio de garantía exclusivo de componentes. Según las condiciones de este servicio exclusivo de componentes, HP le facilitará los componentes de repuesto sin cargo adicional alguno.
Para este servicio de garantía exclusivo de componentes, es obligatoria la sustitución de componentes por parte del usuario (CSR). Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Customer self repair 9
Page 10
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair).
Garantieservice "Parts Only"
Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen van de Parts Only garantieservice zal HP kosteloos vervangende onderdelen ter beschikking stellen.
Voor de Parts Only garantieservice is vervanging door CSR-onderdelen verplicht. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente. Existem duas categorias de peças CSR:
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis. A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair).
Serviço de garantia apenas para peças
A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segundo os termos do serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar nenhuma taxa.
Customer self repair 10
Page 11
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Customer self repair 11
Page 12
Customer self repair 12
Page 13
Customer self repair 13
Page 14
Customer self repair 14
Page 15

Illustrated parts catalog

1
Processor air baffle
779140-001
Mandatory1
2
Drive blank
670033-001
Mandatory1
3
Server blank
774728-001
Mandatory1
4
Processor
a) 1.60 GHz Intel Xeon E5-2603 v3, 85W* **
762441-001
Optional2

Server system components

HP continually improves and changes product parts. For complete and current supported parts information, see the HP PartSurfer website (http://partsurfer.hp.com).
Item Description
Spare part number
Customer self repair (on page 5)
Illustrated parts catalog 15
Page 16
b) 1.90 GHz Intel Xeon E5-2609 v3, 85W* **
762443-001
Optional2
c) 2.40 GHz Intel Xeon E5-2620 v3, 85W* **
762445-001
Optional2
d) 1.80 GHz Intel Xeon E5-2630L v3, 50W* **
762459-001
Optional2
e) 2.40 GHz Intel Xeon E5-2630 v3, 85W* **
762446-001
Optional2
f) 3.50 GHz Intel Xeon E5-2637 v3, 135W* **
762455-001
Optional2
g) 2.60 GHz Intel Xeon E5-2640 v3, 90W* **
762447-001
Optional2
h) 3.40 GHz Intel Xeon E5-2643 v3, 90W* **
762456-001
Optional2
i) 1.80 GHz Intel Xeon E5-2650L v3, 65W* **
762461-001
Optional2
j) 2.30 GHz Intel Xeon E5-2650 v3, 105W* **
762448-001
Optional2
k) 2.60 GHz Intel Xeon E5-2660 v3, 105W* **
762449-001
Optional2
l) 2.30 GHz Intel Xeon E5-2670 v3, 120W* **
762450-001
Optional2
m) 2.50 GHz Intel Xeon E5-2680 v3, 120W* **
762451-001
Optional2
n) 2.00 GHz Intel Xeon E5-2683 v3, 120W* **
762453-001
Optional2
o) 2.60 GHz Intel Xeon E5-2690 v3, 135W* **
762452-001
Optional2
p) 2.30 GHz Intel Xeon E5-2695 v3, 120W* **
762454-001
Optional2
q) 2.30 GHz Intel Xeon E5-2698 v3, 135W* **
780760-001
Optional2 5
Heatsink
779142-001
Optional2
6
Drive cage assembly
a) Drive cage assembly with drive backplane, 4 SFF drives
794875-001
Mandatory1
b) Drive cage assembly with drive backplane, 2 SFF drives
794878-001
Optional2 7
PCIe riser board assembly, x16 and x8 riser board
794877-001
Optional2
8
Rear PCIe riser board, x16
794876-001
Mandatory1
9
Front panel/LED board assembly
779137-001
Optional2
10
System battery*
234556-001
Mandatory1
DIMMs
a) 8-GB, single-rank, PC4-2133R
774170-001
Mandatory1
b) 8-GB, dual-rank, PC4-2133R*
774171-001
Mandatory1
c) 16-GB, dual-rank, PC4-2133P*
812221-001
Mandatory1
d) 16-GB, dual-rank, PC4-2133L*
774173-001
Mandatory1
e) 32-GB, dual-rank, PC4-2133R*
774175-001
Mandatory1
f) 32-GB, quad-rank, PC4-2133L*
774174-001
Mandatory1 12
Power expander board
738764-001
Optional2
System board
786718-001
Optional2 14
SFF drives
a) 2.0-T SAS HDD, 12G, 7,200 rpm
765873-001
Mandatory1
Item Description
Spare part number
Customer self repair (on page 5)
11
13
Illustrated parts catalog 16
Page 17
b) 2.0-T SATA HDD, 6G, 7,200 rpm*
765869-001
Mandatory1
c) 1.8-T SAS HDD, 12G, 10,000 rpm*
791055-001
Mandatory1
d) 1.2-T SAS HDD, 12G, 10,000 rpm*
781578-001
Mandatory1
e) 1.0-T SAS HDD, 12G, 7,200 rpm*
653954-001
Mandatory1
f) 1.0-T SATA HDD, 6G, 7,200 rpm*
752672-001
Mandatory1
g) 1.0-T SAS HDD, 6G, 10,000 rpm*
765872-001
Mandatory1
h) 1.0-T SATA HDD, 6G, 7,200 rpm*
656108-001
Mandatory1
i) 1.0-T SATA HDD, 6G, 7,200 rpm*
765868-001
Mandatory1
j) 900-GB SAS HDD, 12G, 10,000 rpm*
785411-001
Mandatory1
k) 900-GB SAS HDD, 6G, 10,000 rpm*
653971-001
Mandatory1
l) 600-GB SAS HDD, 12G, 10,000 rpm*
781577-001
Mandatory1
m) 600-GB SAS HDD, 6G, 10,000 rpm*
653957-001
Mandatory1
n) 500-GB SAS HDD, 6G, 7,200 rpm*
752671-001
Mandatory1
o) 500-GB SAS HDD, 6G, 7,200 rpm*
653953-001
Mandatory1
q) 450-GB SAS HDD, 6G, 10,000 rpm*
653956-001
Mandatory1
r) 300-GB SAS HDD, 12G, 10,000 rpm*
785410-001
Mandatory1
s) 300-GB SAS HDD, 6G, 10,000 rpm*
653955-001
Mandatory1
t) 300-GB SAS HDD, 6G, 15,000 rpm*
653960-001
Mandatory1
u) 1.92-T SAS SSD, 12G, VE*
802911-001
Mandatory1
v) 1.6-T SAS SSD, 12G, MLC, VE*
780436-001
Mandatory1
w) 800-GB SAS SSD, 12G, MLC*
780434-001
Mandatory1
x) 800-GB SAS SSD, 12G, ME*
741228-001
Mandatory1
y) 800-GB SAS SSD, 12G HE*
802909-001
Mandatory1
z) 800-GB SAS SSD, 12G, HE*
741234-001
Mandatory1
aa) 800-GB SATA SSD, MLC*
692167-001
Mandatory1
bb) 600-GB SATA SSD, 6G, VE*
739959-001
Mandatory1
dd) 400-GB SAS SSD, 12G, ME*
741226-001
Mandatory1
ee) 400-GB SAS SSD, 12G, HE*
802907-001
Mandatory1
ff) 400-GB SAS SSD, 12G, HE*
741232-001
Mandatory1
gg) 400-GB SATA SSD, MLC*
692166-001
Mandatory1
hh) 300-GB SATA SSD, 6G, VE*
739954-001
Mandatory1
ii) 200-GB SATA SSD, 12G, MLC, VE*
780430-001
Mandatory1
Item Description
p) 500-GB SATA HDD, 7,200 rpm* 656107-001 Mandatory1
Spare part number
Customer self repair (on page 5)
cc) 400-GB SAS SSD, 12G, MLC* 780432-001 Mandatory1
Illustrated parts catalog 17
Page 18
jj) 200-GB SATA SSD, MLC*
692165-001
Mandatory1
kk) 200-GB SAS SSD, 12G, ME*
741224-001
Mandatory1
ll) 200-GB SAS SSD, 12G, HE*
741230-001
Mandatory1
mm) 200-GB SAS SSD, 12G, HE*
802905-001
Mandatory1
nn) 100-GB 2.5 SATA SC MLC*
692164-001
Mandatory1 15
PCIe expansion board options
a) HP H240 Smart Host Bus Adapter
779134-001
Optional2
b) HP Smart Array P440 Controller*
749797-001
Optional2
c) HP InfiniBand FDR 2-port 545FLR-QSFP Adapter*
705088-001
Optional2
d) 1.0-TB PCIe I/O accelerator, LE*
775677-001
No3 e) 1.3-TB PCIe I/O accelerator, MLC*
764125-001
No3 f) 1.6-TB PCIe I/O accelerator, MLC*
764126-001
No3
g) 2.6-TB PCIe I/O accelerator, LE*
775679-001
No3
h) 3.2-TB PCIe I/O accelerator, MLC*
764127-001
No3 16
Accelerators
a) Intel Xeon Phi Coprocessor 7120P
732636-001
Optional2
b) Intel Xeon Phi Coprocessor 5110P*
708360-001
Optional2
c) AMD FirePro S9150 GPU*
797639-001
Optional2
d) NVIDIA Tesla K40 GPU Accelerator*
747401-001
Optional2
e) NVIDIA Tesla K80 Dual-GPU Accelerator*
797637-001
Optional2
f) NVIDIA GRID K1 Quad GPU*
788358-001
Optional2 17
HP Smart Storage Battery with cable, 12W*
786762-001
Mandatory1
18
Trusted Platform Module*
505836-001
No3
19
Cables
a) HP c-Class Blade SUV cable*
416003-001
Mandatory1
c) Accelerator power cable, 60.96 cm (24.00 in), 300W*
635899-001
Mandatory1
d) Mini-SAS data cable, embedded controller*
799415-001
Mandatory1
e) Mini-SAS data cable, embedded controller or HP H240 Smart
799198-001
Mandatory1 f) Mini-SAS data cable, HP H240 Smart Host Bus Adapter*
799419-001
Mandatory1
g) Mini-SAS data cable, HP Smart Array P440 Controller*
799411-001
Mandatory1
h) Drive power cable, lower tray 12GB backplane*
799414-001
Mandatory1
i) Drive power cable, upper tray*
794881-001
Mandatory1
j) Drive power and data cable assembly, non-hot-plug*
815416-001
Mandatory1
Item Description
Spare part number
Customer self repair (on page 5)
b) Intra-tray signal cable* 794880-001 Mandatory1
Host Bus Adapter*
Illustrated parts catalog 18
Page 19
k) Drive power cable, 400 mm (15.75 in), 12-GB backplane with HP Smart Array P440 Controller*
792837-001
Mandatory1
l) Drive power cable, 300 mm (11.81 in), 12-GB backplane with HP Smart Array P440 Controller*
792836-001
Mandatory1
m) Intel Xeon Phi coprocessor 5110P power cable, 609.6mm (24 in), 300W*
571876-001
Mandatory1
n) Intel Xeon Phi coprocessor 7120P power cable, 609.6 mm (24 in), 300W*
571876-001
Mandatory1
o) AMD FirePro S9150 GPU power cable, 609.6mm (24 in), 300W
571876-001
Mandatory1
p) NVIDIA Tesla K40 GPU accelerator power cable, 609.6mm (24 in), 300W*
635901-001
Mandatory1
q) NVIDIA Tesla K80 Dual-GPU accelerator power cable, 609.6mm (24 in), 300W*
799422-001
Mandatory1
r) NVIDIA GRID K1 Quad-GPU accelerator power cable, 609.6mm (24 in), 150W*
635903-001
Mandatory1
Item Description
Spare part number
Customer self repair (on page 5)
* Not shown **All processors in this HP ProLiant server must have the same cache size, speed, number of cores, and rated maximum power consumption.
1
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be
charged for the travel and labor costs of this service.
2
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
3
No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.
1
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
2
Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
3
No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention “Non” dans le Catalogue illustré.
1
Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
2
Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
3
No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un “No” nel Catalogo illustrato dei componenti.
1
Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet.
2
Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.
Illustrated parts catalog 19
Page 20
3
No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
1
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
2
Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.
3
No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de componentes.
1
Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2
Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
3
No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
1
Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
2
Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
3
No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca “No” (Não), no catálogo de peças ilustrado.
Illustrated parts catalog 20
Page 21

I/O module components

HP continually improves and changes product parts. For complete and current supported parts information, see the HP PartSurfer website (http://partsurfer.hp.com).
Illustrated parts catalog 21
Page 22
5
1
HP Apollo 6000 2 Slot FlexibleLOM Riser and I/O module
774720-001
Optional2
I/O module adapter options
a) HP Flex Fabric 40-GB 2-port 544FLR Adapter
779132-001
Optional2
b) HP Flex Fabric 10-GB 2-port 544+ FLR Adapter*
764738-001
Optional2
c) HP Ethernet 1-GB 4-port 331FLR Adapter*
634025-001
Optional2
d) HP Ethernet 1-GB 4-port 366FLR Adapter*
669280-001
Optional2
e) HP Ethernet 10Gb 2-port 561FLR-T Adapter*
701525-001
Optional2
f) HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter*
701531-001
Optional2
g) HP FlexFabric 10Gb 2-port 533FLR-T Adapter*
701534-001
Optional2
h) HP FlexFabric 10Gb 2P 556FLR-SFP+ Adapter*
764460-001
Optional2
I) HP Ethernet 10Gb 2P 561FLR-T Adapter
701525-001
Optional2
m) HP Ethernet 10Gb 2-port 546FLR-SFP+ Adapter*
790315-001
Optional2
o) HP Ethernet 10Gb 2-port 560FLR Adapter*
669281-001
Optional2 3
HP Ethernet Dual 1Gb 1-port 364i Adapter and I/O module
774721-001
Optional2
4
5
PCIe/FlexibleLOM I/O module adapter options*
a) HP StoreFabric SN1100E 15Gb Dual Port Fibre Channel Host Bus Adapter*
719212-001
Mandatory1
b) HP StoreFabric SN1100E 15Gb Single Port Fibre Channel Host Bus Adapter*
719211-001
Mandatory1 6
Item Description
2
n) HP Ethernet 10Gb 2-port 546 SFP+ Adapter* 790314-001 Optional2
Spare part number
Customer self repair (on page
)
HP Apollo 6000 PCIe/FlexibleLOM Riser and I/O module* 815417-002 Optional2
* Not shown
1
charged for the travel and labor costs of this service.
2
however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
3
an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.
1
remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
2
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
3
que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention “Non” dans le Catalogue illustré.
1
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
I/O module blank* 774727-001 Mandatory1
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If,
No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de
Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également
No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour
Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
Illustrated parts catalog 22
Page 23
2
Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
3
No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un “No” nel Catalogo illustrato dei componenti.
1
Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet.
2
Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.
3
No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
1
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
2
Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.
3
No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de componentes.
1
Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2
Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
3
No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
1
Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
2
Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
3
No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca “No” (Não), no catálogo de peças ilustrado.
Illustrated parts catalog 23
Page 24
Illustrated parts catalog 24
Page 25

Removal and replacement procedures

Required tools

You need the following items for some procedures:
T-10 Torx screwdriver
T-15 Torx screwdriver
HP Insight Diagnostics (on page 80)

Safety considerations

Preventing electrostatic discharge

Before performing service procedures, review all the safety information.
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.

Symbols on equipment

The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions.
This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure.
Removal and replacement procedures 25
Page 26
ire, or damage to the equipment, do
To reduce the risk of injury from a hot component, allow the surface to cool
duce the risk of personal injury or damage to the equipment, observe
To reduce the risk of injury from electric shock, remove all power cords to
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, f
not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING:
before touching.
This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
WARNING: To re
local occupational health and safety requirements and guidelines for manual material handling.
13.61 kg
30.00 lb
These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.
WARNING:
completely disconnect power from the system.

Server warnings and cautions

Before installing a server, be sure that you understand the following warnings and cautions.
WARNING: To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.

Preparation procedures

To access some components and perform certain service procedures, you must perform one or more of the following procedures:
Power down the server (on page 27).
Remove the server (on page 27).
Removal and replacement procedures 26
Page 27
Remove the upper server tray (on page 28).
When the server is in standby mode, auxiliary power is still being provided to the
Remove the I/O module (on page 32).
Install the upper server tray (on page 30).
Install the server (on page 33).

Power down the server

Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs.
IMPORTANT:
To power down the server, use one of the following methods:
Press and release the Power On/Standby button.
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter
Use a virtual power button selection through iLO 4.
system.
This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.
standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS. If an application stops responding, you can use this method to force a shutdown.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.

Remove the server

CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
all bays are populated with a component or a blank.
Removal and replacement procedures 27
Page 28
3.
Remove the server.
4. Place the server on a flat, level work surface.

Remove the accelerator cages

Use the appropriate procedure for the accelerator cage procedure being performed.

Remove the upper server tray

1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
Removal and replacement procedures 28
Page 29
6.
Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
10. Remove the accelerator cages (on page 28).
11. Remove the upper server tray.

Remove the upper server tray support bracket

1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
IMPORTANT: If the foam blocks are dislodged when removing the support bracket, be sure to
install the foam blocks before installing the support bracket.
Removal and replacement procedures 29
Page 30
5.
Remove the upper server support bracket.

Install the upper server tray support bracket

IMPORTANT: If the foam blocks are dislodged when removing the support bracket, be sure to
1. Install the upper server tray support bracket.
install the foam blocks before installing the support bracket.
2. Install the server into the chassis ("Install the server" on page 33).
3. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

Install the upper server tray

Removal and replacement procedures 30
Page 31
CAUTION: To avoid damage to the drives, memory, and other system components, the air
baffle, and drive blanks must be installed when the server is powered up.
1. Connect the intra-tray signal cable to the system board on the lower server tray.
2. While aligning the upper server tray for installation, feed the the intra-tray signal cable and the drive
cable up through the space indicated for the cable routing. For information on routing the intra-tray signal cable, see "Intra-tray signal cable routing (on page 94)." For information on routing the drive cables, see "Drive cabling (on page 91)."
3. Install the upper server tray.
Removal and replacement procedures 31
Page 32
4.
Connect the intra-tray signal cable to the power expander board.
5. Remove the upper tray support bracket ("Remove the upper server tray support bracket" on page 29).
6. Connect and route all accelerator cables to the power expander board ("Accelerator option cabling"
on page 94).
7. Install the upper server tray support bracket (on page 30).
8. Install the accelerator cages ("Accelerator (front)" on page 40, "Accelerator (rear)" on page 41).
9. Connect and route all cables for drive cage assembly 2 ("Drive cabling" on page 91).
10. Install drive cage assembly 2 ("Drive cage assembly 2" on page 55).
11. Install all drives ("Drive" on page 35).
12. Install the server into the chassis ("Install the server" on page 33).
13. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

Remove the I/O module

1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
Removal and replacement procedures 32
Page 33
3.
If an I/O module blank is not installed in the associated even-numbered I/O module bay, install an I/O module blank in the associated even-numbered bay.
4. Remove the I/O module.

Install the server

CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless
all bays are populated with a component or a blank.
IMPORTANT: When installing an HP ProLiant XL250a Gen9 Server, be sure that only I/O
module blanks are installed in the even-numbered I/O module bays. Failure to do so may cause the I/O modules in the even-numbered bays to disengage or to be damaged.
Removal and replacement procedures 33
Page 34
1.
Prepare the server for installation.
2. Install the server. When seated properly, the server will be flush with the front of the chassis and the
release lever will close completely without resistance.
3. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.
Removal and replacement procedures 34
Page 35

Drive blank

To prevent improper cooling and thermal damage, do not operate the server unless
Remove the component as indicated.
To replace the blank, slide the blank into the bay until it locks into place.

Drive

To remove the component:
1. Determine the status of the drive from the drive LED definitions ("Hot-plug drive LED definitions" on page
2. Back up all data on the drive.
3. Remove the drive.
CAUTION:
all bays are populated with either a component or a blank.
85).
To replace the drive, slide the drive into the bay until it is fully seated, and then close the latch handle to lock the drive in the bay.
Removal and replacement procedures 35
Page 36

PCIe/FlexibleLOM I/O module

To remove the component:
1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
3. Remove the PCIe/FlexibleLOM I/O module.
To replace the component, reverse the removal procedure.

PCIe/FlexibleLOM I/O module PCIe options

To remove the component:
1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
3. Remove the PCIe/FlexibleLOM I/O module ("PCIe/FlexibleLOM I/O module" on page 36).
Removal and replacement procedures 36
Page 37
4.
Remove the cover from the PCIe/FlexibleLOM I/O module.
5. Remove the PCIe/FlexLOM I/O module expansion board.
To replace the component, reverse the removal procedure.

PCIe/FlexibleLOM I/O module FlexibleLOM options

To remove the component:
1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
3. Remove the PCIe/FlexibleLOM I/O module ("PCIe/FlexibleLOM I/O module" on page 36).
Removal and replacement procedures 37
Page 38
4.
Remove the cover from the PCIe/FlexibleLOM I/O module.
5. Remove the FlexibleLOM adapter from the FlexibleLOM slot on the PCIe/FlexibleLOM riser.
To replace the component, reverse the removal procedure.

HP Ethernet Dual 1Gb 1-port 364i Adapter and I/O module

I/O modules are specific to each server and are installed in the rear of the chassis. The chassis has ten I/O module bays located in the rear of the chassis. I/O module blanks are supported in all even-numbered bays and I/O modules are supported in all odd-numbered bays.
To remove the component:
1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
Removal and replacement procedures 38
Page 39
3.
If an I/O module blank is not installed in the associated even-numbered I/O module bay, install an I/O module blank in the associated even-numbered bay.
4. Remove the I/O module.
To replace the component, reverse the removal procedure.

Dual FlexibleLOM riser options

To remove the component:
1. Power down the server associated with the I/O module ("Power down the server" on page 27).
2. Remove the server associated with the I/O module ("Remove the server" on page 27).
3. Remove the I/O module (on page 32).
Removal and replacement procedures 39
Page 40
4.
Using a T-10 Torx screwdriver, remove the I/O module FlexibleLOM adapter.
To replace the component, reverse the removal procedure.

Accelerator (front)

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
6. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
7. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
8. Disconnect the accelerator cable from the power expander board ("Accelerator option cabling" on
page 94).
Removal and replacement procedures 40
Page 41
9.
Remove the front accelerator cage.
10. Remove the accelerator from the accelerator cage.
To replace the component, reverse the removal procedure.

Accelerator (rear)

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
Removal and replacement procedures 41
Page 42
6.
Disconnect the intra-tray signal cable from the power expander board.
7. Remove the rear accelerator cage.
Removal and replacement procedures 42
Page 43
8.
Remove the accelerator from the accelerator cage.
To replace the component, reverse the removal procedure.

Power expander board

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Remove the upper tray support bracket ("Remove the upper server tray support bracket" on page 29).
6. Disconnect the intra-tray signal cable from the power expander board.
Removal and replacement procedures 43
Page 44
7.
Disconnect the drive power cable and the accelerator cables from the power expander board. For more information, see "Cabling (on page 91)."
8. Remove the power expander board.
To replace the component, reverse the removal procedure.

Processor air baffle

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
Removal and replacement procedures 44
Page 45
6.
Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the processor air baffle.
To replace the component, reverse the removal procedure.

DIMMs

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
Removal and replacement procedures 45
Page 46
5.
Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the processor air baffle ("Processor air baffle" on page 44).
14. Remove the DIMM.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 46
Page 47

Rear PCIe riser board

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the processor air baffle ("Processor air baffle" on page 44).
Removal and replacement procedures 47
Page 48
14.
Remove the rear PCIe riser board.
To replace the component, reverse the removal procedure.

PCIe riser board assembly

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
Removal and replacement procedures 48
Page 49
8.
Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the PCIe riser board assembly.
14. Disconnect all cables connected to existing expansion boards.
To replace the component, reverse the removal procedure.

PCIe expansion board options

The server supports installation of options in the PCIe riser board assembly. For more information about supported options, see the product QuickSpecs on the HP website (http://www.hp.com/go/qs).
Some expansion board options may ship with a plastic baffle or scoop installed on the board. Always remove this baffle before attempting to install either option on this server.
IMPORTANT: Remove the baffle or scoop from the controller before installing the controller in the
To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
PCIe riser board assembly.
Removal and replacement procedures 49
Page 50
5.
Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
14. Disconnect all cables connected to existing expansion boards.
15. Using a T-15 Torx screwdriver, remove the PCIe expansion board option installed on the PCI riser board
assembly.
Removal and replacement procedures 50
Page 51
To replace the component, reverse the removal procedure.

Cache module

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
14. Remove the PCIe expansion board ("PCIe expansion board options" on page 49).
15. Disconnect the cable from the cache module.
Removal and replacement procedures 51
Page 52
16.
Remove the cache module from the controller.
To replace the component, reverse the removal procedure.

HP Smart Storage Battery option

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
Removal and replacement procedures 52
Page 53
10.
Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the front PCI riser board assembly ("PCIe riser board assembly" on page 48).
14. Disconnect the HP Smart Storage battery from the system board.
15. Remove the HP Smart Storage battery.
To replace the component, reverse the removal procedure.
To locate the HP Smart Storage battery on the system board, see "System board components (on page 85)."

Drive cage assembly 1

To remove the component:
1. Back up all server data on the drive.
2. Power down the server (on page 27).
3. Disconnect all peripheral cables from the server.
4. Remove the server (on page 27).
5. Place the server on a flat, level work surface.
Removal and replacement procedures 53
Page 54
6.
Disconnect the intra-tray signal cable from the power expander board.
7. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
8. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
9. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
10. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
11. Remove the front accelerator cage ("Accelerator (front)" on page 40).
12. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
13. Remove the upper server tray (on page 28).
14. Remove the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
15. Disconnect all cables from the drive cage backplane. Depending on the controller being used, your
server may look slightly different than what is shown.
Removal and replacement procedures 54
Page 55
16.
Disconnect the front panel LED board assembly cables.
17. Remove all drives ("Drive" on page 35).
18. Using a T-10 Torx screwdriver, remove the drive cage assembly.
To replace the component, reverse the removal procedure.

Drive cage assembly 2

To remove the component:
1. Back up all server data on the drive.
2. Power down the server (on page 27).
3. Disconnect all peripheral cables from the server.
4. Remove the server (on page 27).
5. Place the server on a flat, level work surface.
Removal and replacement procedures 55
Page 56
6.
Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Using a T-10 Torx screwdriver, remove the drive cage assembly.
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
To replace the component, reverse the removal procedure.

Front panel LED board assembly

To remove the component:
1. Back up all server data on the drive.
2. Power down the server (on page 27).
3. Disconnect all peripheral cables from the server.
4. Remove the server (on page 27).
5. Place the server on a flat, level work surface.
Removal and replacement procedures 56
Page 57
6.
Disconnect the intra-tray signal cable from the power expander board.
7. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
8. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
9. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
10. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
11. Remove the front accelerator cage ("Accelerator (front)" on page 40).
12. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
13. Remove the upper server tray (on page 28).
14. Remove the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
15. Disconnect the front panel LED board assembly cables.
Removal and replacement procedures 57
Page 58
16.
Remove the front panel LED board assembly.
To replace the component, reverse the removal procedure.

System battery

If the server no longer automatically displays the correct date and time, then replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Locate the battery on the system board ("System board components" on page 85).
Replace only with the spare designated for this product.
Removal and replacement procedures 58
Page 59
6.
Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Heatsink

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
IMPORTANT: Replacing the system board battery resets the system ROM to its default
configuration. After replacing the battery, reconfigure the system through RBSU.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
Removal and replacement procedures 59
Page 60
5.
Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the processor air baffle ("Processor air baffle" on page 44).
14. Remove the heatsink.
Removal and replacement procedures 60
Page 61
To replace the component:
1. Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to evaporate
before continuing.
2. Remove the thermal interface protective cover from the heatsink.
CAUTION: To avoid damage to the system board, processor socket, and screws, do not
overtighten the heatsink screws. Use the wrench supplied with the system to reduce the possibility
3. Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly.
of overtightening the screws.
4. Install the processor air baffle ("Processor air baffle" on page 44).
Removal and replacement procedures 61
Page 62
5.
Connect the intra-tray signal cable to the system board on the lower server tray.
6. While aligning the upper server tray for installation, feed the the intra-tray signal cable and the drive
cable up through the space indicated for the cable routing. For information on routing the intra-tray signal cable, see "Intra-tray signal cable routing (on page 94)." For information on routing the drive cables, see "Drive cabling (on page 91)."
7. Install the upper server tray (on page 30).
8. Connect the intra-tray signal cable to the power expander board.
9. Remove the upper tray support bracket ("Remove the upper server tray support bracket" on page 29).
10. Connect and route all accelerator cables to the power expander board ("Accelerator option cabling"
on page 94).
11. Install the upper server tray support bracket (on page 30).
12. Install the rear accelerator cage ("Accelerator (rear)" on page 41).
13. Install the front accelerator cage ("Accelerator (front)" on page 40).
14. Connect and route all cables for drive cage assembly 2 ("Drive cabling" on page 91).
Removal and replacement procedures 62
Page 63
, the
15.
Install drive cage assembly 2 ("Drive cage assembly 2" on page 55).
16. Install all drives ("Drive" on page 35).
17. Install the server into the chassis ("Install the server" on page 33).
18. Connect all peripheral cables to the server.
19. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

Processor

To remove the component:
1. Update the system ROM.
Locate and download the latest ROM version from the HP website (http://www.hp.com/support). Follow the instructions on the website to update the system ROM.
2. Power down the server (on page 27).
3. Disconnect all peripheral cables from the server.
4. Remove the server (on page 27).
5. Place the server on a flat, level work surface.
6. Disconnect the intra-tray signal cable from the power expander board.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent possible server overheating, always populate each processor socket with
a processor socket cover and a heatsink blank or a processor and a heatsink.
IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty
server does not power up.
7. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
Removal and replacement procedures 63
Page 64
8.
Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
9. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
10. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
11. Remove the front accelerator cage ("Accelerator (front)" on page 40).
12. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
13. Remove the upper server tray (on page 28).
14. Remove the processor air baffle ("Processor air baffle" on page 44).
15. Remove the heatsink ("Heatsink" on page 59).
16. Open each of the processor locking levers in the order indicated, and then open the processor retaining
bracket.
CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To
avoid damage to the system board, do not touch the processor or the processor socket contacts.
Removal and replacement procedures 64
Page 65
17.
Remove the processor from the processor retaining bracket.
To replace the component:
CAUTION: To avoid damage to the system board, processor socket, and screws, do not
overtighten the heatsink screws. Use the wrench supplied with the system to reduce the possibility of overtightening the screws.
Removal and replacement procedures 65
Page 66
1.
Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE
SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To
avoid damage to the system board, do not touch the processor or the processor socket contacts.
CAUTION: Do not press down on the processor. Pressing down on the processor may cause
damage to the processor socket and the system board. Press only in the area indicated on the
2. Close the processor retaining bracket. When the processor is installed properly inside the processor
processor retaining bracket.
retaining bracket, the processor retaining bracket clears the flange on the front of the socket.
Removal and replacement procedures 66
Page 67
3.
Press and hold the processor retaining bracket in place, and then close each processor locking lever. Press only in the area indicated on the processor retaining bracket.
4. Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly.
5. Install the processor air baffle ("Processor air baffle" on page 44).
Removal and replacement procedures 67
Page 68
6.
Connect the intra-tray signal cable to the system board on the lower server tray.
7. While aligning the upper server tray for installation, feed the the intra-tray signal cable and the drive
cable up through the space indicated for the cable routing. For information on routing the intra-tray signal cable, see "Intra-tray signal cable routing (on page 94)." For information on routing the drive cables, see "Drive cabling (on page 91)."
8. Install the upper server tray (on page 30).
9. Connect the intra-tray signal cable to the power expander board.
10. Remove the upper tray support bracket ("Remove the upper server tray support bracket" on page 29).
11. Connect and route all accelerator cables to the power expander board ("Accelerator option cabling"
on page 94).
12. Install the upper server tray support bracket (on page 30).
13. Install the rear accelerator cage ("Accelerator (rear)" on page 41).
14. Install the front accelerator cage ("Accelerator (front)" on page 40).
15. Connect and route all cables for drive cage assembly 2 ("Drive cabling" on page 91).
Removal and replacement procedures 68
Page 69
16.
Install drive cage assembly 2 ("Drive cage assembly 2" on page 55).
17. Install all drives ("Drive" on page 35).
18. Install the server into the chassis ("Install the server" on page 33).
19. Connect all peripheral cables to the server.
20. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

System board

To remove the component:
1. Power down the server (on page 27).
2. Disconnect all peripheral cables from the server.
3. Remove the server (on page 27).
4. Place the server on a flat, level work surface.
5. Disconnect the intra-tray signal cable from the power expander board.
6. Remove all drives from drive cage assembly 2 ("Drive" on page 35).
7. Remove drive cage assembly 2 ("Drive cage assembly 2" on page 55).
8. Disconnect and remove the drive cables connected to drive cage assembly 2 ("Drive cabling" on page
91).
9. Remove the rear accelerator cage ("Accelerator (rear)" on page 41).
10. Remove the front accelerator cage ("Accelerator (front)" on page 40).
11. Disconnect all accelerator cables from the power expander board ("Accelerator option cabling" on
page 94).
12. Remove the upper server tray (on page 28).
13. Remove the processor air baffle ("Processor air baffle" on page 44).
14. Remove the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
Removal and replacement procedures 69
Page 70
15.
Disconnect all cables from the drive cage backplane.
16. Disconnect the front panel LED board assembly cables.
Removal and replacement procedures 70
Page 71
17.
Disconnect the intra-tray signal cable from the system board.
18. Remove all DIMMs ("DIMMs" on page 45).
19. Remove all heatsinks ("Heatsink" on page 59).
20. Remove all processors ("Processor" on page 63).
21. Remove the failed system board.
Removal and replacement procedures 71
Page 72
To replace the system board:
1. Install the system board.
2. Connect all cables disconnected from the failed system board.
3. Connect cables to the drive backplane ("Drive cabling" on page 91).
4. Install all processors ("Processor" on page 63).
5. Install all heatsinks ("Heatsink" on page 59).
6. Install all DIMMs ("DIMMs" on page 45).
7. Install the processor air baffle ("Processor air baffle" on page 44).
8. Install the PCIe riser board assembly ("PCIe riser board assembly" on page 48).
Removal and replacement procedures 72
Page 73
9.
Connect the intra-tray signal cable to the system board on the lower server tray.
10. While aligning the upper server tray for installation, feed the the intra-tray signal cable and the drive
cable up through the space indicated for the cable routing. For information on routing the intra-tray signal cable, see "Intra-tray signal cable routing (on page 94)." For information on routing the drive cables, see "Drive cabling (on page 91)."
11. Install the upper server tray (on page 30).
12. Connect the intra-tray signal cable to the power expander board.
13. Remove the upper tray support bracket ("Remove the upper server tray support bracket" on page 29).
14. Connect and route all accelerator cables to the power expander board ("Accelerator option cabling"
on page 94).
15. Install the upper server tray support bracket (on page 30).
16. Install the rear accelerator cage ("Accelerator (rear)" on page 41).
17. Install the front accelerator cage ("Accelerator (front)" on page 40).
18. Connect and route all cables for drive cage assembly 2 ("Drive cabling" on page 91).
Removal and replacement procedures 73
Page 74
Any attempt to remove an installed TPM from the system board breaks or disfigures
19.
Install drive cage assembly 2 ("Drive cage assembly 2" on page 55).
20. Install all drives ("Drive" on page 35).
21. Install the server into the chassis ("Install the server" on page 33).
22. Connect all peripheral cables to the server.
23. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

Re-entering the server serial number and product ID

IMPORTANT: When re-entering the serial number, be sure to use the server serial number. This
number is located on the front panel serial number/iLO information pull tab ("Front panel
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Service Options.
4. Select Serial Number. The following warning appears:
5. Press the Enter key to clear the warning.
6. Enter the serial number and press the Enter key.
7. Select Product ID. The following warning appears:
8. Enter the product ID and press the Enter key.
components" on page 82). Do not use the chassis serial number.
Warning: The serial number should ONLY be modified by qualified service personnel. This value should always match the serial number located on the chassis.
Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always match the Product ID located on the chassis.
9. Press the Esc key to close the menu.
10. Press the Esc key to exit RBSU.
11. Press the F10 key to confirm exiting RBSU. The server automatically reboots.

HP Trusted Platform Module

The TPM is not a customer-removable part.
CAUTION:
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure
If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact an HP authorized service provider for a replacement system board and TPM board.
the integrity of the system data.
Removal and replacement procedures 74
Page 75

Troubleshooting

Troubleshooting resources

The HP ProLiant Gen9 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language:
English (http://www.hp.com/support/Gen9_TSG_en)
French (http://www.hp.com/support/Gen9_TSG_fr)
Spanish (http://www.hp.com/support/Gen9_TSG_es)
German (http://www.hp.com/support/Gen9_TSG_de)
Japanese (http://www.hp.com/support/Gen9_TSG_ja)
Simplified Chinese (http://www.hp.com/support/Gen9_TSG_zh_cn)
The HP ProLiant Gen9 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language:
English (http://www.hp.com/support/Gen9_EMG_en)
French (http://www.hp.com/support/Gen9_EMG_fr)
Spanish (http://www.hp.com/support/Gen9_EMG_es)
German (http://www.hp.com/support/Gen9_EMG_de)
Japanese (http://www.hp.com/support/Gen9_EMG_ja)
Simplified Chinese (http://www.hp.com/support/Gen9_EMG_zh_cn)
Troubleshooting 75
Page 76

Diagnostic tools

Product QuickSpecs

For more information about product features, specifications, options, configurations, and compatibility, see

HP iLO

the product QuickSpecs on the HP website (http://www.hp.com/go/qs).
The iLO 4 subsystem is a standard component of HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. The iLO 4 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 4 independent of the host server and its operating system.
iLO 4 enables and manages the Active Health System (on page 77) and also features Agentless Management. All key internal subsystems are monitored by iLO 4. If enabled, SNMP alerts are sent directly by iLO 4 regardless of the host operating system or even if no host operating system is installed.
Embedded remote support software is available on HP ProLiant Gen8 and later servers with iLO 4, regardless of the operating system software and without installing OS agents on the server.
Using iLO 4, you can do the following:
Access a high-performance and secure Integrated Remote Console to the server from anywhere in the
world if you have a network connection to the server.
Use the shared .NET Integrated Remote Console to collaborate with up to four server administrators.
Remotely mount high-performance Virtual Media devices to the server.
Securely and remotely control the power state of the managed server.
Implement true Agentless Management with SNMP alerts from HP iLO, regardless of the state of the host
server.
Download the Active Health System log.
Register for HP Insight Remote Support.
Use iLO Federation to manage multiple servers from one system running the iLO web interface.
Use Virtual Power and Virtual Media from the GUI, the CLI, or the iLO scripting toolkit for many tasks,
including the automation of deployment and provisioning.
Control iLO by using a remote management tool.
For more information about iLO 4 features, see the iLO 4 documentation on the HP website (http://www.hp.com/go/ilo/docs).
The HP iLO 4 hardware and firmware features and functionality, such as NAND size and embedded user partition, vary depending on the server model. For a complete list of supported features and functionality, see the HP iLO 4 QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/14276_div/14276_div.pdf).
Diagnostic tools 76
Page 77

Active Health System

HP Active Health System provides the following features:
Combined diagnostics tools/scanners
Always on, continuous monitoring for increased stability and shorter downtimes
Rich configuration history
Health and service alerts
Easy export and upload to Service and Support
The HP Active Health System monitors and records changes in the server hardware and system configuration. The Active Health System assists in diagnosing problems and delivering rapid resolution if server failures occur.
The Active Health System collects the following types of data:
Server model
Serial number
Processor model and speed
Storage capacity and speed
Memory capacity and speed
Firmware/BIOS
HP Active Health System does not collect information about Active Health System users' operations, finances, customers, employees, partners, or data center, such as IP addresses, host names, user names, and passwords. HP Active Health System does not parse or change operating system data from third-party error event log activities, such as content created or passed through by the operating system.
The data that is collected is managed according to the HP Data Privacy policy. For more information see the HP website (http://www.hp.com/go/privacy).
The Active Health System, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components.
The Agentless Management Service is available in the SPP, which can be downloaded from the HP website (http://www.hp.com/go/spp/download). The Active Health System log can be downloaded manually from iLO 4 or HP Intelligent Provisioning and sent to HP.
For more information, see the following documents:
HP iLO User Guide on the HP website (http://www.hp.com/go/ilo/docs)
HP Intelligent Provisioning User Guide on the HP website
(http://www.hp.com/go/intelligentprovisioning/docs)

HP ProLiant Pre-boot Health Summary

If the server will not start up, you can use iLO 4 to display diagnostic information on an external monitor. This feature is supported on servers that support external video and have a UID button or an SUV connector. When power is available to the server but the server is not powered on, iLO runs on auxiliary power and can take control of the server video adapter to display the HP ProLiant Pre-boot Health Summary.
Diagnostic tools 77
Page 78
For additional information, see the following documents:
Access System Utilities
F9 during server POST
HP iLO 4 User GuideSee the HP website (http://www.hp.com/go/ilo/docs).
HP ProLiant Gen9 Troubleshooting Guide, Volume I: Troubleshooting — See "Troubleshooting
Resources (on page 75)."

Integrated Management Log

The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.
You can view recorded events in the IML in several ways, including the following:
From within HP SIM
From within HP UEFI System Utilities (on page 78)
From within the Embedded UEFI shell
From within operating system-specific IML viewers:
o For Windows: IML Viewer
o For Linux: IML Viewer Application
From within the iLO 4 web interface
From within HP Insight Diagnostics (on page 80)

HP UEFI System Utilities

The HP UEFI System Utilities is embedded in the system ROM. The UEFI System Utilities enable you to perform a wide range of configuration activities, including:
Configuring system devices and installed options
Enabling and disabling system features
Displaying system information
Selecting the primary boot controller
Configuring memory options
Selecting a language
Launching other pre-boot environments such as the Embedded UEFI Shell and Intelligent Provisioning
For more information on the HP UEFI System Utilities, see the HP UEFI System Utilities User Guide for HP ProLiant Gen9 Servers on the HP website (http://www.hp.com/go/ProLiantUEFI/docs).
Scan the QR code located at the bottom of the screen to access mobile-ready online help for the UEFI System Utilities and UEFI Shell. For on-screen help, press F1.

Using HP UEFI System Utilities

To use the System Utilities, use the following keys.
Action Key
Diagnostic tools 78
Page 79
Action Key
Navigate menus
Up and Down arrows
Select items
Enter
Save selections
F10
option*
F1
Access Help for a highlighted configuration
*Scan the QR code on the screen to access online help for the UEFI System Utilities and UEFI Shell.
Default configuration settings are applied to the server at one of the following times:
Upon the first system power-up
After defaults have been restored
Default configuration settings are sufficient for typical server operations; however, you can modify configuration settings as needed. The system prompts you for access to the System Utilities each time the system is powered up.

Embedded Diagnostics option

The system BIOS in all HP ProLiant Gen9 servers includes an Embedded Diagnostics option in the ROM. The Embedded Diagnostics option can run comprehensive diagnostics of the server hardware, including processors, memory, drives, and other server components.
For more information on the Embedded Diagnostics option, see the HP UEFI System Utilities User Guide for HP ProLiant Gen9 Servers on the HP website (http://www.hp.com/go/ProLiantUEFI/docs).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access UEFI System Utilities.
2. Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options >
Advanced System ROM Options > Serial Number, and then press the Enter key.
3. Enter the serial number and press the Enter key. The following message appears:
The serial number should only be modified by qualified service personnel. This value should always match the serial number located on the chassis.
4. Press the Enter key to clear the warning.
5. Enter the serial number and press the Enter key.
6. Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always match the Product ID located on the chassis.
7. Enter the product ID and press the Enter key.
8. Press the F10 key to confirm exiting System Utilities. The server automatically reboots.
Diagnostic tools 79
Page 80

HP Insight Diagnostics

HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.
HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS is not running. To run this utility, boot the server using Intelligent Provisioning.
HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft Windows and Linux versions, the utility helps to ensure proper system operation.
For more information or to download the utility, see the HP website (http://www.hp.com/servers/diags). HP

HP Insight Diagnostics survey functionality

Insight Diagnostics Online Edition is also available in the SPP.
HP Insight Diagnostics (on page 80) provides survey functionality that gathers critical hardware and software information on ProLiant servers.
This functionality supports operating systems that are supported by the server. For operating systems supported by the server, see the HP website (http://www.hp.com/go/supportos).
If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.
Survey functionality is installed with every Intelligent Provisioning-assisted HP Insight Diagnostics installation, or it can be installed through the SPP.

HP Insight Remote Support

HP strongly recommends that you register your device for remote support to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or HP contractual support agreement. HP Insight Remote Support supplements your monitoring continuously to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level. Notifications can be sent to your authorized HP Channel Partner for onsite service, if configured and available in your country.
For more information, see HP Insight Remote Support and Insight Online Setup Guide for ProLiant Servers and BladeSystem c-Class Enclosures on the HP website (http://www.hp.com/go/insightremotesupport/docs). HP Insight Remote Support is available as part of HP Warranty, HP Care Pack Service, or HP contractual support agreement.

USB support

HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.
Legacy USB support provides USB functionality in environments where USB support is not available normally. Specifically, HP provides legacy USB functionality for the following:
Diagnostic tools 80
Page 81
POST (system boot)
UEFI System Utilities
Pre-boot UEFI shell
DOS
Operating environments which do not provide native USB support

External USB functionality

HP provides external USB support to enable local connection of USB devices for server administration, configuration, and diagnostic procedures.
For additional security, external USB functionality can be disabled through USB options in UEFI System Utilities.

Automatic Server Recovery

ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer, the ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.
ASR increases server availability by restarting the server within a specified time after a system hang. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the System Management Homepage or through RBSU.
Diagnostic tools 81
Page 82

Component identification

1
Drive bays (6)
2
Serial label pull tab
3
SUV connector
4
Server release latch
Server release lever 6
Server release lever thumbscrew

Front panel components

Item Description
5
Component identification 82
Page 83

Hot-plug drive numbering

1
Drive cage 1, drive bay 1
2
Drive cage 1, drive bay 2
3
Drive cage 1, drive bay 3
4
Drive cage 1, drive bay 4
5
Drive cage 2, drive bay 3
6
Drive cage 2, drive bay 4
Item Description

Front panel LEDs and buttons

Component identification 83
Page 84
UID button/LED*
Solid blue = Activated
Health LED*
Solid green = Normal
Power On/Standby button and system
Solid green = System on
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
controller/Smart SAS HBA controller
6 flashes System board PCIe slots
7 flashes
Power backplane or storage backplane
8 flashes
Power supply
9 flashes
Item Description Status
1
Flashing blue (1 Hz/cycle per sec) = Remote management or firmware upgrade in progress Off = Deactivated
2
NIC status LED* Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active Off = No network activity
3
Flashing green (1 Hz/cycle per sec) = iLO is rebooting Flashing amber = System degraded Flashing red (1 Hz/cycle per sec) = System critical
4
power LED*
Flashing green (1 Hz/cycle per sec) = Performing power on sequence Solid amber = System in standby Off = No power present**
*When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see "Front panel LED power fault codes (on page 84)." **Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the power button cable is disconnected.

Front panel LED power fault codes

The following table provides a list of power fault codes, and the subsystems that are affected. Not all power faults are used by all servers.
Subsystem Front panel LED behavior
Removable HP Flexible Smart Array
For more information, see "Front panel LEDs and buttons (on page 83)."
Component identification 84
Page 85

Hot-plug drive LED definitions

1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update. 2
Activity ring
Rotating green
Drive activity
Off
No drive activity
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of Off
Removing the drive does not cause a logical drive to fail. 4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, strip size Flashing
The drive is a member of one or more logical drives and predicts Flashing amber
The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
Item LED Status Definition
3
the logical drives to fail.
migration, capacity expansion, or logical drive extension, or is erasing.
amber/green
the drive will fail.

System board components

Component identification 85
Page 86
1
Front accelerator riser slot and PCIe riser board connector
2
TPM connector
3
System battery
4
Processor 2
5
Processor 2 DIMMs (4)
Processor 1 DIMMs (4)
Intra-tray signal cable connector 8
Processor 1
9
Rear I/O connector
10
Rear accelerator riser slot connector
11
Processor 1 DIMMs (4)
12
MicroSD card slot riser
13
Processor 2 DIMMs (4)
SATA connector 1
SATA connector 2 16
HP Smart Storage Battery cable connector
17
System maintenance switch
18
19
Front panel LED board cable connector
Item Description
6
7
14
15
Backplane power connector

DIMM slot locations

DIMM slots are numbered sequentially (1 through 8) for each processor. The supported AMP modes use the alpha assignments for population order, and the slot numbers designate the DIMM slot ID for spare replacement.
The arrow indicates the front of the server.
Component identification 86
Page 87
Off
Off = iLO security is enabled. S3
Off
Reserved
S4
Off
Reserved
Off
Off = Power-on password is enabled.
Off
Off = No function. On = ROM reads system configuration
Off
Off = Set default boot mode to UEFI. S8
Reserved
S9
Reserved
S10
Reserved
S11
Reserved
S12
Reserved
1
Rear accelerator (PCIe slot 1)
2
Front accelerator (PCIe slot 2)

System maintenance switch

Position Default Function
S1
S2
S5
S6
S7
Off Off = System configuration can be
On = iLO security is disabled.
changed. On = System configuration is locked.
On = Power-on password is disabled.
as invalid.
On = Set default boot mode to legacy.
To access the redundant ROM, set S1, S5, and S6 to on.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.

Accelerator numbering

Item Description
Component identification 87
Page 88

Power expander board components

1
Drive backplane power connector (drive cage 2)
2
Front accelerator power cable connector
3
Rear accelerator power cable connector
4
Intra-tray signal cable connector
PCIe slot 1
PCIe3 x16 (Rear accelerator)
PCIe slot 2
PCIe3 x16 (Front accelerator)
PCIe slot 3
PCIe3 x8 (PCIe riser board assembly lower slot)
FlexibleLOM 1
PCIe3 x16 (16, 8, 4, 2, 1)
FlexibleLOM 2
PCIe3 x8 (8, 4, 2, 1)
Item Description

Expansion slot definitions

Expansion slot Slot description
Component identification 88
Page 89
FlexibleLOM 1 — PCIe3 x16 (16,
FlexibleLOM — PCIe3 x8 (8, 4,
FlexibleLOM 2 — PCIe3 x8 (8, 4,
PCIe LP — PCIe3 x16 (16, 8, 4,

I/O module bay numbering

IMPORTANT: When installing an HP ProLiant XL250a Gen9 Server, be sure that only I/O
module blanks are installed in the even-numbered I/O module bays. Failure to do so may cause
I/O modules are specific to each server and are installed in the rear of the chassis.
The chassis has ten I/O module bays located in the rear of the chassis. I/O module blanks are supported in all even-numbered bays and I/O modules are supported in all odd-numbered bays.
For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the HP website (http://www.hp.com/go/qs).
the I/O modules in the even-numbered bays to disengage or to be damaged.

I/O module slot definitions

Item
1
2
Dual FlexibleLOM I/O module slot description
8, 4, 2, 1)
2, 1)
PCIe/FlexibleLOM I/O module slot description
2, 1)
2, 1)
Component identification 89
Page 90
Component identification 90
Page 91

Cabling

Internal server cabling

This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance.
CAUTION: When routing cables, always be sure that the cables are not in a position where they

Front panel LED board assembly cabling

can be pinched or crimped.

Drive cabling

Select the drive cable routing that is associated with the controller being used. All blue cables represent the drive power cables and the green cables are Mini-SAS data cables.
Cabling 91
Page 92
Embedded controller
HP Smart Array P440 Controller
Cabling 92
Page 93
HP Smart Array H240 Host Bus Adapter

HP Smart Storage Battery cabling

Cabling 93
Page 94

Accelerator option cabling

The accelerator cables connect to the power expander board in the rear of the upper tray. For more information, see "Power expander board components (on page 88)."

Intra-tray signal cable routing

SUV cable connectors

CAUTION: Before disconnecting the SUV cable from the connector, always squeeze the release
buttons on the sides of the connector. Failure to do so can result in damage to the equipment.
Cabling 94
Page 95
Serial
For trained personnel to connect a null modem serial cable 2
USB*
For connecting up to two USB devices
3
Video
For connecting a video monitor
Item Connector Description
1
*The USB connectors on the SUV cable do not support devices that require greater than a 500mA power source.
and perform advanced diagnostic procedures
Cabling 95
Page 96

Specifications

Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
(noncondensing)**
— Operating
10% to 90%
Nonoperating
5% to 95%
21.15 cm (8.33 in) Depth
70.79 cm (27.87 in)
Width
8.76 cm (3.49 in)
accelerators)
13.61 kg (30.00 lb)

Environmental specifications

Specification Value
Relative humidity
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048 m (10,000 ft) is applicable. No direct sunlight is allowed. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 kPa.

Server specifications

Specification Value
Height
Weight (maximum: two processors, six hard drives, two
Specifications 96
Page 97

Acronyms and abbreviations

ABEND
abnormal end
AMP
Advanced Memory Protection
ASR
Automatic Server Recovery
CSR
Customer Self Repair
HP SIM
HP Systems Insight Manager
iLO
Integrated Lights-Out
IML
Integrated Management Log
LOM
LAN on Motherboard
NVRAM
nonvolatile memory
PCI
peripheral component interconnect
PCIe
Peripheral Component Interconnect Express
POST
Power-On Self Test
Acronyms and abbreviations 97
Page 98
RBSU
ROM-Based Setup Utility
SAS
serial attached SCSI
SD
Secure Digital
SFF
small form factor
SIM
Systems Insight Manager
SPP
HP Service Pack for ProLiant
SUV
serial, USB, video
TPM
Trusted Platform Module
UEFI
Unified Extensible Firmware Interface
UID
unit identification
USB
universal serial bus
Acronyms and abbreviations 98
Page 99

Documentation feedback

HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.
Documentation feedback 99
Page 100

Index

A
accelerator 41, 42, 88 accelerator cage removal 29 accelerator option cabling 94 ASR (Automatic Server Recovery) 82 Automatic Server Recovery (ASR) 82
B
battery 53, 59 bay numbering, I/O module 89 button, UID 84 buttons 83 buttons, front panel 83, 84
C
cable routing diagrams 91 cable, routing 91, 94 cable, SUV 94 cables 91 cables, overview 91 cabling 91, 94 cabling, server 91, 94 cache module 52 cautions 26, 27 CMOS 88 components 16, 26, 83, 89 components, front panel 83 components, identification 16, 83 components, mechanical 16 components, server 16 components, system board 86 connectors 83 controller 50 controller components 83 CSR (customer self repair) 6 customer self repair (CSR) 6
D
diagnostics utility 81 dimensions and weight 96 DIMM numbering 87 DIMM slot locations 87 DIMMs 46, 87 documentation 99 documentation feedback 99 drive 36 drive air baffle 36 drive bays 83 drive blank 36 drive cable, data 91 drive cable, power 91 drive cabling 91 drive cage assembly 54 drive cage assembly, removal 54 drive, removing 36 drives 86 drives, determining status of 86 drives, hot-plug 36
E
electrical 26 electrostatic discharge 26 environmental requirements 96 environmental specifications 96 error messages 76 expansion board 50 external USB functionality 82
F
features 83 firmware upgrade utility, troubleshooting 76 front panel buttons 84 front panel components 83 front panel display cable 91 front panel LED board assembly 57 front panel LED board assembly cabling 91 front panel LEDs 84
definitions 86 diagnosing problems 76 diagnostic tools 77, 80, 81, 82
G
guidelines, troubleshooting 76
Index 100