This document includes feature, installation, and configuration information about HP Smart Array Controllers and is for the person who installs,
administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Microsoft®, Windows®, and Windows Server® are U.S. registered trademarks of Microsoft Corporation.
Controller features ................................................................................................................................... 10
Support and other resources ........................................................................................................ 34
Before you contact HP .............................................................................................................................. 34
HP contact information ............................................................................................................................. 34
Index ......................................................................................................................................... 45
Contents 4
Page 5
Component identification
Controller components
For cabling configuration and troubleshooting purposes, connector names are silk-screened on the controller.
For LED locations and status, see "Controller LEDs (on page 6)."
Item Description
1
2
3
*The 2 GiB cache module connects to a capacitor pack. The 4 GiB cache module connects to a battery pack.
Cache module
Battery or capacitor pack connector*
Internal SAS connector
Component identification 5
Page 6
Controller LEDs
Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a predetermined
pattern as part of the POST sequence. At all other times during server operation, the illumination pattern of
the runtime LEDs indicates the status of the controller.
P430 controller, 2 GB cache module
Item Color Name Interpretation
1
Green
2
3
4
5
P430 controller, 4 GB cache module
Amber Fault When an error occurs, this LED is on. During power up, this LED
Green Reserved —
Green Reserved —
Amber Debug On = Controller is in reset state.
Heartbeat
When the controller is in good health, this LED flashes at 1 Hz.
During power up, this LED is solid for up to 2 seconds.
is solid for up to 2 seconds.
Off = Controller is in an idle or runtime state.
Flashing 5 Hz = Controller and cache are performing a backup.
Item Color Name Interpretation
1
2
Green
Amber Fault When an error occurs, this LED is on. During power up, this LED
Heartbeat
When the controller is in good health, this LED flashes at 1 Hz.
During power up, this LED is solid for up to 2 seconds.
is solid for up to 2 seconds.
3
4
Green Crypto On = Encrypting
Off = Non=encrypting
Flashing = Undergoing retry
Green Reserved —
Component identification 6
Page 7
Item Color Name Interpretation
5
Amber Debug On = Controller is in reset state.
Cache module LEDs
The cache module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the
reverse side of the cache module to facilitate status viewing.
2 GiB cache module
Off = Controller is in an idle or runtime state.
Flashing 5 Hz = Controller and cache are performing a backup.
4 GiB cache module
1 - Amber 2 - Green 3 - Green Interpretation
Off
Off
Off
Off
Off
Off Off The cache module is not powered.
Flashing once
every 2 seconds
Flashing once
per second
Off Flashing once
Off On The cache module is idle, and the battery or capacitor
Flashing once
every 2 seconds
Flashing once
per second
per second
The cache microcontroller is executing from within its
boot loader and receiving new flash code from the host
controller.
The cache module is powering up, and the battery or
capacitor pack* is charging.
The cache module is idle, and the battery or capacitor
pack is charging.
pack is charged.
Component identification 7
Page 8
1 - Amber 2 - Green 3 - Green Interpretation
The cache module is idle, the battery or capacitor pack
On
Off
An overtemperature condition exists.
Off
Off
Off
Flashing once
per second
Flashing once
per second
Flashing once
per second
Flashing twice
per second
Flashing twice
per second
On
On
*The 2 GiB cache module connects to a capacitor pack. The 4 GiB cache module connects to a battery pack.
On On
is charged, and the cache contains data that has not yet
been written to the drives.
Flashing once
per second
Off A backup of the DDR content on the cache module is in
progress.
On Off The current backup is complete with no errors.
Flashing once
Off The current backup failed, and data has been lost.
per second
Flashing once
per second
Flashing twice
On A power error occurred during the previous or current
boot. Data may be corrupt.
Off The battery or capacitor pack is not attached.
per second
Flashing twice
per second
On The battery has been charging for 10 minutes, but has
not reached sufficient charge to perform a full backup.
On Off The current backup is complete, but power fluctuations
occurred during the backup.
On On The cache module microcontroller has failed.
Component identification 8
Page 9
Specifications
Memory and storage capacity conventions
Memory capacities are specified using binary prefixes:
• KiB = 2
• MiB = 2
• GiB = 2
• TiB = 2
Storage capacities are specified using SI prefixes:
• KB = 10
• MB = 10
• GB = 10
• TB = 10
10
bytes
20
bytes
30
bytes
40
bytes
3
bytes
6
bytes
9
bytes
12
bytes
Older, and other, documentation may use SI prefixes for binary values.
Actual available memory capacity and actual formatted storage capacity for devices are less than specified
values.
RAID conventions
HP uses the following naming convention for RAID levels:
• RAID 0
• RAID 10
• RAID 5
• RAID 50
• RAID 6
• RAID 60
• RAID 1 (ADM)
• RAID 10 (ADM)
RAID 50 and RAID 60 are also known in the industry as RAID 5+0 and RAID 6+0, respectively.
Specifications 9
Page 10
Controller features
Basic features
This HP Smart Array controller has the following basic features:
• Mirror splitting and recombining in offline mode
• Drive Erase
• Performance optimization for video on demand
• Capability for moving and deleting individual LUNs
• Split mirror backup and rollback of RAID 1, 10, 1 (ADM) and 10 (ADM) mirrors
• Heal Array
For more information, see the HP Smart Storage Administrator User Guide on the HP website
(http://www.hp.com/go/smartstorage/docs).
HP SmartCache
HP SmartCache is an advanced feature that enables solid state drives to be used as caching devices for hard
drive media. Data can be accessed from the solid state drive instead of hard drives. HP SmartCache provides
the following features:
• Accelerates application performance
• Provides lower latency for transactions in applications
• Supports all operating systems, without the need for changes
Use the HP SSA utility to configure support for HP SmartCache. This feature requires a license key.
For more information, see the HP Smart Storage Administrator User Guide on the HP website
(http://www.hp.com/go/smartstorage/docs).
HP SSD Smart Path
HP SSD Smart Path enables an optimized data path to high performance solid state drives. The optimized
path bypasses the controller’s RAID processing components and sends I/O directly to the drives. For more
information, see the HP website
(http://h18004.www1.hp.com/products/servers/proliantstorage/software-management/smartpath/inde
x.html).
For more information on enabling or disabling HP SSD Smart Path, see the HP Smart Storage Administrator User Guide on the HP website (http://www.hp.com/go/smartstorage/docs).
HP Secure Encryption
HP Secure Encryption is a controller-based, enterprise-class data encryption solution that protects data at rest
on any bulk storage HDDs and SSDs attached to an HP Smart Array P430 Controller. The solution is
Specifications 10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.