This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and
software. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products, and are familiar with weight and stability precautions.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Intel® Xeon® is a trademark of Intel Corporation in the U.S. and other countries.
While some of the documentation that supports this product contains the HP Proliant and the DL380p Gen8 Server product names,
most of the information in those documents is relevant to this workstation product. Since this product is supported on VMware and
Citrix operating systems only, information specific to Microsoft Windows and Linux may not apply.
Parts only warranty service ......................................................................................................................... 5
Illustrated parts catalog ............................................................................................................... 15
Air baffle ............................................................................................................................................... 30
Power supply blank ................................................................................................................................. 36
AC power supply .................................................................................................................................... 37
Power supply backplane .......................................................................................................................... 40
Hot-plug fan ........................................................................................................................................... 41
Fan cage ................................................................................................................................................ 42
SFF hard drive cage ................................................................................................................................ 45
Systems Insight Display ............................................................................................................................ 45
Front panel assembly ............................................................................................................................... 46
System battery ........................................................................................................................................ 63
System board ......................................................................................................................................... 64
150W PCIe power cable option ............................................................................................................... 70
225W PCIe power cable option ............................................................................................................... 70
Chipset SATA cable option ....................................................................................................................... 71
HP Trusted Platform Module ...................................................................................................................... 71
Index ......................................................................................................................................... 95
Contents 4
Page 5
Customer self repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for
greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service
providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will
ship that part directly to you for replacement. There are two categories of CSR parts:
•Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts,
you will be charged for the travel and labor costs of this service.
•Optional—Parts for which customer self repair is optional. These parts are also designed for customer
self repair. If, however, you require that HP replace them for you, there may or may not be additional
charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,
HP requires that an authorized service provider replace the part. These parts are identified as "No" in the
Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day
delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.
If assistance is required, you can call the HP Technical Support Center and a technician will help you over the
telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must
be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective
part back to HP within a defined period of time, normally five (5) business days. The defective part must be
returned with the associated documentation in the provided shipping material. Failure to return the defective
part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping
and part return costs and determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider. For the
North American program, refer to the HP website (http://www.hp.com/go/selfrepair).
Parts only warranty service
Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only warranty
service, HP will provide replacement parts free of charge.
For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace these parts,
you will be charged for the travel and labor costs of this service.
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin
de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la
période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être
effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:
Customer self repair 5
Page 6
Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de
remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de
remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à
votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la
réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué
par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation
géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même
ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le
Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise
s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai
indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans
l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les
coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de
retour, et détermine la société de courses ou le transporteur à utiliser.
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus
d'informations sur ce programme en Amérique du Nord, consultez le site Web HP
(http://www.hp.com/go/selfrepair).
Service de garantie "pièces seules"
Votre garantie limitée HP peut inclure un service de garantie "pièces seules". Dans ce cas, les pièces de
rechange fournies par HP ne sont pas facturées.
Dans le cadre de ce service, la réparation des pièces CSR par le client est obligatoire. Si vous demandez à
HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti
difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente
dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza
HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per
la sostituzione. Vi sono due categorie di parti CSR:
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti
progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere
spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la
garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono
identificate da un "No" nel Catalogo illustrato dei componenti.
Customer self repair 6
Page 7
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il
giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento
di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del
centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente
deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve
spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il
componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione
fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP.
Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il
corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il
programma in Nord America fare riferimento al sito Web HP (http://www.hp.com/go/selfrepair).
Servizio di garanzia per i soli componenti
La garanzia limitata HP può includere un servizio di garanzia per i soli componenti. Nei termini di garanzia
del servizio per i soli componenti, HP fornirà gratuitamente le parti di ricambio.
Per il servizio di garanzia per i soli componenti è obbligatoria la formula CSR che prevede la riparazione da
parte del cliente. Se il cliente invece richiede la sostituzione ad HP, dovrà sostenere le spese di spedizione
e di manodopera per il servizio.
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere
Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der
Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses
Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen
Service berechnet.
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten,
können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche
Kosten anfallen.
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog
sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.
Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen
Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und
sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert
werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es
erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen
Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen
Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das
Customer self repair 7
Page 8
defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer
Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den
Kurier-/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner
vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter
(http://www.hp.com/go/selfrepair).
Parts-only Warranty Service (Garantieservice
ausschließlich für Teile)
Ihre HP Garantie umfasst möglicherweise einen Parts-only Warranty Service (Garantieservice ausschließlich
für Teile). Gemäß den Bestimmungen des Parts-only Warranty Service stellt HP Ersatzteile kostenlos zur
Verfügung.
Für den Parts-only Warranty Service ist das CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch
dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service
berechnet.
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar
sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios
de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente
CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se
clasifican en dos categorías:
•Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a
HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de
desplazamiento y de mano de obra de dicho servicio.
•Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos
componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si
precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de
servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que
el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado
realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No" en el
catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su
destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el
mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de
asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales
para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán
devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá
hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes
defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no
Customer self repair 8
Page 9
enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas
sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de
componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en
contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite
la página web de HP siguiente (http://www.hp.com/go/selfrepair).
Servicio de garantía exclusivo de componentes
La garantía limitada de HP puede que incluya un servicio de garantía exclusivo de componentes. Según las
condiciones de este servicio exclusivo de componentes, HP le facilitará los componentes de repuesto sin
cargo adicional alguno.
Para este servicio de garantía exclusivo de componentes, es obligatoria la sustitución de componentes por
parte del usuario (CSR). Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse
cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze
onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij
de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat
onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee
categorieën CSR-onderdelen:
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen
voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen
voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen
daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het
product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met
de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.
Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de
eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden
aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service
Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het
vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte
onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde
periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de
bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het
defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij
reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en
kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Customer self repair 9
Page 10
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma
van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair).
Garantieservice "Parts Only"
Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen van
de Parts Only garantieservice zal HP kosteloos vervangende onderdelen ter beschikking stellen.
Voor de Parts Only garantieservice is vervanging door CSR-onderdelen verplicht. Als u HP verzoekt deze
onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening
gebracht.
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a
minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se,
durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo
pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.
Existem duas categorias de peças CSR:
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças,
serão cobradas as despesas de transporte e mão-de-obra do serviço.
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o
reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de
taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de
cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão
identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o
pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser
feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico
da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR
de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é
preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.
A peça com defeito deve ser enviada com a documentação correspondente no material de transporte
fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a
HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço
postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o
fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
(http://www.hp.com/go/selfrepair).
Customer self repair 10
Page 11
Serviço de garantia apenas para peças
A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segundo os termos do
serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar nenhuma taxa.
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas
peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Customer self repair 11
Page 12
Customer self repair 12
Page 13
Customer self repair 13
Page 14
Customer self repair 14
Page 15
Illustrated parts catalog
A
A
Mechanical components
Item Description Spare part number Customer self repair
(on page 5)
1
2
3
4
5
ccess panel 662534-001Mandatory1
Fan cage 662518-001Mandatory
SFF front panel assembly ——
a) 8 bay, with cables, left and right ears, no
backplane
b) 25 bay, with cables, left and right ears, with
backplane*
PCI riser cage——
a) PCI riser cage, standard 662526-001Mandatory1
b) PCI riser cage, double-wide*709860-001Mandatory1
c) PCI riser cage, NEBS* 709859-001Mandatory1
ir baffle 662527-001Mandatory1
675602-001Optional2
696958-001Optional2
Illustrated parts catalog 15
1
Page 16
Item Description Spare part number Customer self repair
(on page 5)
6
7
8
9
10
11
12
13
14
15
16
17
18
19
* Not shown
1
charged for the travel and labor costs of this service.
2
however, you require that HP replace them for you, there may or may not be additional charges, depending on the type
of warranty service designated for your product.
3
an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.
Hard drive blank* ——
a) Hard drive blank, SFF 667276-001Mandatory1
b) Hard drive blank, LFF 667279-001Mandatory1
Heatsink blank* 662522-001Mandatory
1
DIMM blank*716110-001Mandatory1
Processor cage* 662537-001Optional
2
Hardware blank kit* 662519-001Mandatory1
a) Optical device blank ——
b) Fan blank ——
c) FlexibleLOM blank ——
d) PCI riser cage blank ——
e) Expansion slot blank ——
Power supply blank 699833-001Mandatory1
2U rack bezel* 662529-001Mandatory1
Plastic battery holder (12 LFF/25 SFF)*687957-001Mandatory1
Miscellaneous hardware kit* 662523-001Mandatory1
a) Fan bracket, left ——
b) Fan bracket, right ——
c) DVD cable routing guide ——
d) DIMM guard ——
e) Basepan cable retention clip——
Miscellaneous hardware kit 2*700383-001Mandatory1
a) Processor blank air deflector assembly——
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If,
No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that
Illustrated parts catalog 16
Page 17
1
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de
remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
2
Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces
pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
3
No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour
que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces
pièces sont identifiées par la mention “Non” dans le Catalogue illustré.
1
Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
2
Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti
progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese
addizionali a seconda del tipo di garanzia previsto per il prodotto.
3
No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la
garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate
da un “No” nel Catalogo illustrato dei componenti.
1
Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie
diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet.
2
Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei
diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.
3
No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,
muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw.
„Nein“ gekennzeichnet.
1
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP
que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano
de obra de dicho servicio.
2
Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos componentes
también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su
sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al
producto.
3
No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario
haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos
componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de componentes.
1
Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te
vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2
Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn
ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen
daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
3
No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de
garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze
onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
1
Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças,
serão cobradas as despesas de transporte e mão-de-obra do serviço.
2
Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o
reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa
adicional, dependendo do tipo de serviço de garantia destinado ao produto.
3
No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia
do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca “No”
(Não), no catálogo de peças ilustrado.
Illustrated parts catalog 17
Page 18
System components
Illustrated parts catalog 18
Page 19
Item Description Spare part number Customer self repair (on
page 5)
System components
22
23
24
25
26
27
28
29
30
31
32
33
34
Hot-plug fan 662520-001Mandatory1
Power supply, hot-plug ——
1200 W, Platinum Plus, 94%*660185-001Mandatory1
Boards
System board assembly ——
System board assembly-IVB 732143-001Optional2
Riser boards ——
a) PCIe riser board, standard 3-slot662524-001Optional2
b) PCIe riser board, optional 2-slot*662525-001Optional2
Power supply backplane 662528-001Mandatory1
Systems Insight Display subassembly, LFF, with
cables
Systems Insight Display subassembly, SFF, with
cables*
HP Trusted Platform Module* 505836-001No3
FlexibleLOM ——
a) HP 1GbE 4-port, 331FLR Adapter FIO Kit634025-001Mandatory1
b) HP 10GbE 2-port, 530FLR Adapter FIO Kit*649869-001Mandatory1
Memory
DIMMs ——
a) 8-GB, PC3-14900R, dual-rank x4*715273-001Mandatory1
b) 16-GB, PC3-14900R, quad-rank x4*715274-001Mandatory1
Processors** ——
a) 2.6-GHz Intel Xeon processor E5-2630v2,
**All processors in this HP ProLiant server must have the same cache size, speed, number of cores, and rated maximum
power consumption.
1
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be
charged for the travel and labor costs of this service.
2
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If,
however, you require that HP replace them for you, there may or may not be additional charges, depending on the type
of warranty service designated for your product.
3
No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that
an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.
1
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de
remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
2
Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces
pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
3
No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour
que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces
pièces sont identifiées par la mention “Non” dans le Catalogue illustré.
1
Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
2
Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti
progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese
addizionali a seconda del tipo di garanzia previsto per il prodotto.
3
No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la
garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate
da un “No” nel Catalogo illustrato dei componenti.
1
Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie
diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet.
2
Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei
diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.
3
No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,
muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw.
„Nein“ gekennzeichnet.
1
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP
que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano
de obra de dicho servicio.
2
Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos componentes
también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su
sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al
producto.
3
No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario
haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos
componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de componentes.
1
Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te
vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2
Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn
ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen
daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
3
No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de
garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze
onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
Illustrated parts catalog 21
Page 22
1
Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças,
serão cobradas as despesas de transporte e mão-de-obra do serviço.
2
Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o
reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa
adicional, dependendo do tipo de serviço de garantia destinado ao produto.
3
No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia
do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca “No”
(Não), no catálogo de peças ilustrado.
Illustrated parts catalog 22
Page 23
Removal and replacement procedures
Required tools
You need the following items for some procedures:
• T-10/T-15 Torx screwdriver
Preparation procedures
To access some components and perform certain service procedures, you must perform one or more of the
following procedures:
• Extend the server from the rack (on page 24).
If you are performing service procedures in an HP, Compaq branded, telco, or third-party rack cabinet,
you can use the locking feature of the rack rails to support the server and gain access to internal
components.
For more information about telco rack solutions, refer to the RackSolutions.com website
(http://www.racksolutions.com/hp).
• Power down the server (on page 23).
If you must remove a server from a rack or a non-hot-plug component from a server, power down the
server.
• Remove the server from the rack (on page 25).
If the rack environment, cabling configuration, or the server location in the rack creates awkward
conditions, remove the server from the rack.
• Access the product rear panel (on page 25).
• Access the Systems Insight Display (on page 27).
• Release the full-length expansion board retainer (on page 27).
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical
server data and programs.
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the
To power down the server, use one of the following methods:
• Press and release the Power On/Standby button.
system.
This method initiates a controlled shutdown of applications and the OS before the server enters standby
mode.
Removal and replacement procedures 23
Page 24
• Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter
standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS.
If an application stops responding, you can use this method to force a shutdown.
• Use a virtual power button selection through HP iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server enters
standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.
Extend the server from the rack
1. Pull down the quick release levers on each side of the server.
2. Extend the server from the rack.
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
3. After performing the installation or maintenance procedure, slide the server back into the rack, and then
press the server firmly into the rack to secure it in place.
WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release
latches and sliding the server into the rack. The sliding rails could pinch your fingers.
Removal and replacement procedures 24
Page 25
Remove the server from the rack
To remove the server from an HP, Compaq branded, telco, or third-party rack:
1. Power down the server (on page 23).
2. Extend the server from the rack (on page 24).
3. Disconnect the cabling and remove the server from the rack. For more information, refer to the
documentation that ships with the rack mounting option.
4. Place the server on a sturdy, level surface.
Removal and replacement procedures 25
Page 26
Access the product rear panel
Opening the cable management arm
IMPORTANT: The cable management arm is not supported with the friction rail kit.
To access the server rear panel:
1. Release the cable management arm.
2. Open the cable management arm. Note that the cable management arm can be right-mounted or
left-mounted.
Removal and replacement procedures 26
Page 27
Access the Systems Insight Display
To access the HP Systems Insight Display in a server with a LFF configuration:
1. Press and release the panel.
2. After the display fully ejects, rotate the display downward to view the LEDs.
Release the full-length expansion board retainer
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
Removal and replacement procedures 27
Page 28
5. Release the full-length expansion board retainer.
To replace the component, reverse the removal procedure.
Safety considerations
Preventing electrostatic discharge
Symbols on equipment
Before performing service procedures, review all the safety information.
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system
or handling parts. A discharge of static electricity from a finger or other conductor may damage system
boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
• Avoid hand contact by transporting and storing products in static-safe containers.
• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
• Place parts on a grounded surface before removing them from their containers.
• Avoid touching pins, leads, or circuitry.
• Always be properly grounded when touching a static-sensitive component or assembly.
The following symbols may be placed on equipment to indicate the presence of potentially hazardous
conditions.
This symbol indicates the presence of hazardous energy circuits or electric shock
hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
Removal and replacement procedures 28
Page 29
This symbol indicates the presence of electric shock hazards. The area contains no user
or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do
not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is
contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to
cool before touching.
This symbol indicates that the component exceeds the recommended weight for one
individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the equipment,
observe local occupational health and safety requirements and guidelines for manual
material handling.
27.66 kg
61.0 lb
These symbols, on power supplies or systems, indicate that the equipment is supplied
by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords
to completely disconnect power from the system.
Server warnings and cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING: To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
• Unplug the power cord from the power supply to disconnect power to the equipment.
• Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Removal and replacement procedures 29
Page 30
Access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
To remove the component:
1. Power down the server (on page 23).
2. Extend the server from the rack (on page 24).
To replace the component:
1. Place the access panel on top of the server with the hood latch open. Allow the panel to extend past the
2. Push down on the hood latch. The access panel slides to a closed position.
3. Tighten the security screw on the hood latch.
internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Open or unlock the locking latch, slide the access panel to the rear of the chassis, and remove the
access panel.
rear of the server approximately 1.25 cm (0.5 in).
Air baffle
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. If any full-length expansion boards are installed, do one of the following:
o Remove the primary PCIe riser cage ("PCIe riser cage (primary)" on page 32)
o Remove the secondary PCIe riser cage ("PCIe riser cage (secondary)" on page 33)
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
IMPORTANT: It is necessary to remove the PCI riser cage only if there is a full-length expansion
board installed.
Removal and replacement procedures 30
Page 31
6. Remove the air baffle.
To replace the component, reverse the removal procedure.
2U rack bezel
To remove the component:
Unlock the 2U rack bezel, press the latch on the 2U rack bezel, and then remove the 2U rack bezel.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 31
Page 32
PCIe riser blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
4. Remove the access panel ("Access panel" on page 29).
5. Remove the PCIe riser blank.
all PCI slots have either an expansion slot cover or an expansion board installed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
To replace the component, reverse the removal procedure.
PCIe riser cage (primary)
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
circuitry remain active until AC power is removed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
Removal and replacement procedures 32
Page 33
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect any external cables that are connected to the expansion board.
6. Disconnect any internal cables that are connected to the expansion board.
7. If any full-length expansion boards are installed, release the full-length expansion board retainer (on
page 27).
8. Remove the PCIe riser cage.
To replace the component, reverse the removal procedure.
PCI riser cage (secondary)
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect any external cables that are connected to the expansion board.
circuitry remain active until AC power is removed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
6. Disconnect any internal cables that are connected to the expansion board.
Removal and replacement procedures 33
Page 34
7. If any full-length expansion boards are installed, release the full-length expansion board retainer (on
page 27).
8. Remove the secondary PCI riser cage.
IMPORTANT: Component appearance may vary.
To replace the component, reverse the removal procedure.
PCIe riser board
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. If any full-length expansion boards are installed, release the full-length expansion board retainer (on
page 27).
6. Remove the PCIe riser cage ("PCIe riser cage (primary)" on page 32).
7. Remove any expansion boards from the PCIe riser cage ("Expansion boards" on page 53).
Removal and replacement procedures 34
Page 35
8. Remove the PCIe riser board.
To replace the component, reverse the removal procedure.
Drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
Remove the drive blank.
To replace the component, slide the component into the bay until it clicks.
all bays are populated with either a component or a blank.
Removal and replacement procedures 35
Page 36
Hot-plug drive
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
1. Determine the status of the drive from the hot-plug drive LED definitions (on page 86).
2. Back up all server data on the drive.
3. Remove the drive.
To replace the component, reverse the removal procedure.
the amount of time the access panel is open.
Power supply blank
Remove the blank.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 36
Page 37
AC power supply
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Access the product rear panel (on page 25).
4. Remove the power supply.
all bays are populated with either a component or a blank.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
To replace the component, reverse the removal procedure.
Optical drive
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove the air baffle ("Air baffle" on page 30).
6. Remove the fan cage ("Fan cage" on page 42).
Removal and replacement procedures 37
Page 38
7. Disconnect the optical drive cable.
8. Remove the optical drive.
Removal and replacement procedures 38
Page 39
9. Remove the optical drive bracket, for use with the replacement optical drive.
10. Before replacing the component, install the optical drive bracket, retained from the optical drive you are
replacing.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 39
Page 40
Power supply backplane
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove all power supplies ("AC power supply" on page 36).
4. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
5. Remove the access panel ("Access panel" on page 29).
6. Disconnect the SATA cable.
7. Remove the power supply backplane.
Removal and replacement procedures 40
Page 41
To replace the component, reverse the removal procedure.
Hot-plug fan
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server.
The server shuts down in the following temperature-related scenarios:
• At POST:
o The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the
cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly shutdown
and enters Standby mode.
o The BIOS performs an orderly shutdown if two or more fans have failed.
o The server performs an immediate shutdown if it detects a critical temperature level.
IMPORTANT: An immediate shutdown is a hardware-controlled function and it overrides any
• In the operating system:
firmware or software actions.
o The Health Driver performs an orderly shutdown if it detects a cautionary temperature level. If the
server detects a critical temperature level before the orderly shutdown occurs, the server performs an
immediate shutdown. Additionally, the Health Driver performs an orderly shutdown if more than
one fan is failed or removed.
o When Thermal Shutdown is disabled in RBSU, the server performs an immediate shutdown if it
detects a critical temperature level.
IMPORTANT: An immediate shutdown is a hardware-controlled function and it overrides any
firmware or software actions.
To remove the component:
1. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
2. Remove the access panel ("Access panel" on page 29).
Removal and replacement procedures 41
Page 42
3. Remove the fan.
To replace the component, reverse the removal procedure.
Fan cage
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove the air baffle ("Air baffle" on page 30).
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Removal and replacement procedures 42
Page 43
6. Remove the fan cage.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
IMPORTANT: For optimum cooling, install fans in all primary fan locations. For more
information, refer to the fan locations table ("Hot-plug fans" on page 88).
To replace the component, reverse the removal procedure.
FlexibleLOM
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
1. Power down the server (on page 23).
2. Remove all power:
circuitry remain active until AC power is removed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove any attached network cables.
4. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
5. Remove the access panel ("Access panel" on page 29).
6. Remove the primary PCIe riser cage ("PCIe riser cage (primary)" on page 32).
7. Loosen the thumbscrew.
8. Remove the existing FlexibleLOM.
Removal and replacement procedures 43
Page 44
Pull the FlexibleLOM toward the front of the server while removing it, to avoid catching it on the rear
chassis.
To replace the component:
1. Firmly seat the FlexibleLOM in the slot, and then tighten the thumbscrew.
2. Install the PCIe riser cage ("PCIe riser cage (primary)" on page 32).
3. Install the access panel ("Access panel" on page 29).
4. Slide the server into the rack.
5. Connect the LAN segment cables.
6. Connect each power cord to the server.
7. Connect each power cord to the power source.
8. Power up the server.
Removal and replacement procedures 44
Page 45
SFF hard drive cage
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove all hot-plug hard drives ("Hot-plug drive" on page 35).
6. Remove the air baffle ("Air baffle" on page 30).
7. Remove the fan cage ("Fan cage" on page 42).
8. Disconnect all cables from the hard drive backplane.
9. Remove the hard drive cage.
To replace the component, reverse the removal procedure.
Systems Insight Display
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
Removal and replacement procedures 45
Page 46
5. Remove the air baffle ("Air baffle" on page 30).
6. Remove the fan cage ("Fan cage" on page 42).
7. Remove the Systems Insight Display:
a. Remove the screw from the rear of the Systems Insight Display.
b. Disconnect the Systems Insight Display cable and the USB cable from the system board, and
disconnect the USB cable from the front of the Systems Insight Display.
c. Remove the Systems Insight Display.
To replace the component, reverse the removal procedure.
Front panel assembly
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove the server from the rack (on page 25).
4. Remove the access panel ("Access panel" on page 29).
Removal and replacement procedures 46
Page 47
5. Remove the serial label pull tab (if it is an 8 LFF, 8 SFF, or 16 SFF configuration), and retain it for the new
front panel assembly.
6. Remove the air baffle ("Air baffle" on page 30).
7. Remove all drives ("Hot-plug drive" on page 35).
8. If installed, remove the optical drive ("Optical drive" on page 37).
9. Remove the fan cage ("Fan cage" on page 42).
10. Disconnect all cables from the front panel assembly.
IMPORTANT: If any cables in the front panel assembly need replacing, the entire front panel
assembly must be replaced.
11. Remove the four T-10 Torx screws from each side, and then remove the front panel assembly.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 47
Page 48
Flash-backed write cache procedures
Two types of procedures are provided for the FBWC option:
• Removal and replacement of failed components:
o Removing the cache module ("Flash-backed write cache module" on page 48)
o Removing the capacitor pack ("Flash-backed write cache capacitor pack" on page 49)
• Recovery of cached data from a failed server ("Recovering data from the flash-backed write cache" on
page 51)
CAUTION: Do not detach the cable that connects the battery pack or capacitor pack to the cache
Flash-backed write cache module
To remove the component:
1. Back up all data.
module. Detaching the cable causes all data in the cache module to be lost.
CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.
2. Close all applications.
3. Power down the server (on page 23).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
5. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
does not erroneously mark the drives as failed when the server is powered up.
page 25) the server from the rack.
6. Remove the access panel ("Access panel" on page 29).
7. If it is populated with expansion boards, remove the PCIe riser cage for better access ("PCIe riser cage
(primary)" on page 32).
8. If the existing cache module is connected to a capacitor pack, observe the FBWC module LEDs:
o If the amber LED is flashing, data is trapped in the cache. Restore system power, and restart this
procedure from step 1.
o If the amber LED is not illuminated, remove the controller from the server, and then continue with the
next step.
Removal and replacement procedures 48
Page 49
9. Open the ejector latches on each side of the cache module connector. Normally, the cache module is
ejected from the cache module connector. If the module is not ejected automatically, remove the cache
module.
10. If the cache module is connected to a capacitor pack, disconnect the capacitor pack cable from the
connector on the top of the cache module.
To replace the component, reverse the removal procedure.
CAUTION: To prevent damage to the cache module during installation, be sure the cache
module is fully inserted before pressing down.
Removal and replacement procedures 49
Page 50
Flash-backed write cache capacitor pack
To remove the component:
1. Back up all data.
2. Close all applications.
3. Power down the server (on page 23).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
5. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
6. Remove the access panel ("Access panel" on page 29).
7. If it is populated with expansion boards, remove the PCIe riser cage for better access ("PCIe riser cage
does not erroneously mark the drives as failed when the server is powered up.
page 25) the server from the rack.
(primary)" on page 32).
8. If the capacitor pack is connected to the cache module, disconnect the capacitor pack cable from the
connector on the top of the cache module.
9. Disconnect the SAS hard drive backplane ribbon cable, and then remove the right fan bracket.
10. Remove the capacitor pack
Removal and replacement procedures 50
Page 51
o 8 or 16 drive SFF
o Secondary location for 12 drive LFF or 25 drive SFF
To replace the component, reverse the removal procedure.
Recovering data from the flash-backed write cache
If the server fails, use the following procedure to recover data temporarily stored in the FBWC.
CAUTION: Before starting this procedure, read the information about protecting against
1. Perform one of the following:
electrostatic discharge ("Preventing electrostatic discharge" on page 28).
o Set up a recovery server using an identical server model. Do not install any internal drives or FBWC
in this server. (HP recommends this option.)
Removal and replacement procedures 51
Page 52
o Find a server that has enough empty drive bays to accommodate all the drives from the failed server
and that meets all the other requirements for drive and array migration.
2. Power down the failed server ("Power down the server" on page 23).
3. Transfer the drives from the failed server to the recovery server.
4. Perform one of the following:
o If the array controller has failed, remove the cache module and capacitor pack from the failed array
controller, and install the cache module and capacitor pack on an identical array controller model
in the recovery server.
o If the server has failed, remove the controller ("Half-length expansion board" on page 54), cache
module, and capacitor pack from the failed server, and install the controller, cache module, and
capacitor pack in the recovery server.
5. Power up the recovery server. If there was data in the cache at the time of the controller or server failure,
a 1792 POST message appears, stating that valid data was flushed from the cache. This data is now
stored on the drives in the recovery server. You can now transfer the drives (and controller, if one is
used) to another server.
If the drives are migrated to different drive positions or there are volumes present in the recovery server,
a 1724 POST message appears, stating that logical drive configuration has been updated
automatically.
Expansion slot blanks
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect any external cables that are connected to the expansion board.
6. Disconnect any internal cables that are connected to the expansion board.
circuitry remain active until AC power is removed.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
7. Remove the PCIe riser cage ("PCIe riser cage (primary)" on page 32).
Removal and replacement procedures 52
Page 53
8. Remove the three torx screws (1) that secure the PCI card cage cover, and then remove the cage cover
(2).
9. Remove the expansion slot blank.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 53
Page 54
Expansion boards
Half-length expansion board
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect any external cables that are connected to the expansion board.
6. Disconnect any internal cables that are connected to the expansion board.
7. Remove the PCIe riser cage ("PCIe riser cage (primary)" on page 32).
8. Remove the expansion board.
circuitry remain active until AC power is removed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 54
Page 55
Full length expansion board
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect any external cables that are connected to the expansion board.
6. Disconnect any internal cables that are connected to the expansion board.
7. Release the full-length expansion board retainer, and then remove the PCIe riser cage.
circuitry remain active until AC power is removed.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
8. Remove the full-length expansion board.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 55
Page 56
Heatsink
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove the air baffle ("Air baffle" on page 30).
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
CAUTION: To avoid thermal shutdown, all fans must be installed in a dual processor
configuration.
6. Loosen the four captive screws (1), and then remove the heatsink (2).
Removal and replacement procedures 56
Page 57
To replace the component:
1. Remove the thermal interface protective cover from the heatsink.
2. Install the heatsink.
3. Install the air baffle ("Air baffle" on page 30).
4. Install the access panel ("Access panel" on page 29).
5. Slide the server into the rack.
6. Connect each power cord to the server.
7. Connect each power cord to the power source.
8. Power up the server.
Removal and replacement procedures 57
Page 58
Processor
To remove the processor:
1. Power down the server (on page 23).
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
CAUTION: To prevent possible server overheating, always populate processor socket 2 with a
processor and a heatsink or a processor socket cover and a heatsink blank.
CAUTION: To avoid thermal shutdown, all fans must be installed in a dual processor
configuration.
IMPORTANT: Processor socket 1 must be populated at all times or the server does not function.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove the air baffle ("Air baffle" on page 30).
6. Remove the heatsink ("Heatsink" on page 55).
Removal and replacement procedures 58
Page 59
7. Open each of the processor locking levers in the order indicated, and then open the processor retaining
bracket.
8. Remove the processor from the processor retaining bracket.
CAUTION: To avoid damage to the processor, do not touch the bottom of the processor,
especially the contact area.
Removal and replacement procedures 59
Page 60
To replace the component:
1. Install the processor. Verify that the processor is fully seated in the processor retaining bracket by
visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE
SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To
avoid damage to the system board, do not touch the processor or the processor socket contacts.
2. Close the processor retaining bracket. When the processor is installed properly inside the processor
retaining bracket, the processor retaining bracket clears the flange on the front of the socket.
CAUTION: Do not press down on the processor. Pressing down on the processor may cause
damage to the processor socket and the system board. Press only in the area indicated on the
processor retaining bracket.
Removal and replacement procedures 60
Page 61
3. Press and hold the processor retaining bracket in place, and then close each processor locking lever.
Press only in the area indicated on the processor retaining bracket.
4. Clean the old thermal grease from the heatsink with the alcohol swab. Allow the alcohol to evaporate
before continuing.
5. Apply all the grease to the top of the processor in the following pattern to ensure even distribution.
Removal and replacement procedures 61
Page 62
6. Install the heatsink.
7. Install the air baffle ("Air baffle" on page 30).
8. Install the access panel ("Access panel" on page 29).
9. Slide the server into the rack.
10. Connect each power cord to the server.
11. Connect each power cord to the power source.
12. Power up the server.
DIMMs
To identify the DIMMs installed in the server, see "DIMM slot locations (on page 85)."
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
5. Remove the air baffle ("Air baffle" on page 30).
Removal and replacement procedures 62
Page 63
6. Remove the DIMM.
To replace the component, reverse the removal procedure.
For DIMM configuration information, see the server user guide.
System battery
If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
• Replace only with the spare designated for this product.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. If installed, remove the secondary PCIe riser cage ("PCIe riser cage (secondary)" on page 33).
6. Locate the battery ("System board components" on page 82).
Removal and replacement procedures 63
Page 64
7. Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
System board
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove the server from the rack (on page 25).
4. Remove all power supplies ("AC power supply" on page 36).
5. Remove the access panel ("Access panel" on page 29).
6. Remove the air baffle ("Air baffle" on page 30).
7. Remove the PCIe riser cage ("PCIe riser cage (primary)" on page 32).
8. If installed, remove the secondary PCIe riser cage ("PCIe riser cage (secondary)" on page 33).
9. If installed, remove the FBWC capacitor pack ("Flash-backed write cache capacitor pack" on page
49).
10. If installed, remove the cache module ("Flash-backed write cache module" on page 48).
11. Remove the FlexibleLOM ("FlexibleLOM" on page 43).
12. Remove all DIMMs ("DIMMs" on page 62).
13. Remove the fan cage ("Fan cage" on page 42).
14. Remove the power supply backplane ("Power supply backplane" on page 40).
15. Disconnect all cables connected to the system board.
Removal and replacement procedures 64
Page 65
16. Remove the heatsink ("Heatsink" on page 55).
17. Remove the processor ("Processor" on page 57).
18. Remove left and right fan cage brackets.
19. Loosen the system board thumbscrews.
20. Remove the system board, using the handle to lift it out of the chassis.
Removal and replacement procedures 65
Page 66
To replace the component:
1. Install the spare system board.
2. Open each of the processor locking levers in the order indicated, and then open the processor retaining
bracket.
Removal and replacement procedures 66
Page 67
3. Remove the clear processor socket cover. Retain the processor socket cover for future use.
4. Install the processor. Verify that the processor is fully seated in the processor retaining bracket by
visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE
SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To
avoid damage to the system board, do not touch the processor or the processor socket contacts.
5. Close the processor retaining bracket. When the processor is installed properly inside the processor
retaining bracket, the processor retaining bracket clears the flange on the front of the socket.
Removal and replacement procedures 67
Page 68
CAUTION: Do not press down on the processor. Pressing down on the processor may cause
damage to the processor socket and the system board. Press only in the area indicated on the
6. Press and hold the processor retaining bracket in place, and then close each processor locking lever.
processor retaining bracket.
Press only in the area indicated on the processor retaining bracket.
7. Install the processor socket cover onto the processor socket of the failed system board.
8. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab.
Allow the alcohol to evaporate before continuing.
9. Apply all the grease to the top of the processor in the following pattern to ensure even distribution.
Removal and replacement procedures 68
Page 69
10. Install the heatsink.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
11. Install all components removed from the failed system board.
12. Install the access panel.
13. Install the power supplies ("AC power supply" on page 36).
14. Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Service Options.
4. Select Serial Number. The following warning appears:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
5. Press the Enter key to clear the warning.
6. Enter the serial number and press the Enter key.
7. Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
8. Enter the product ID and press the Enter key.
9. Press the Esc key to close the menu.
10. Press the Esc key to exit RBSU.
11. Press the F10 key to confirm exiting RBSU. The server automatically reboots.
Removal and replacement procedures 69
Page 70
150W PCIe power cable option
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
Disconnect the cable as indicated.
circuitry remain active until AC power is removed.
To replace the component, reverse the removal procedure.
225W PCIe power cable option
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
Disconnect the cable as indicated.
circuitry remain active until AC power is removed.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 70
Page 71
Chipset SATA cable option
To remove the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 24) or remove ("Remove the server from the rack" on
page 25) the server from the rack.
4. Remove the access panel ("Access panel" on page 29).
5. Remove the air baffle ("Air baffle" on page 30).
6. Remove the fan cage ("Fan cage" on page 42).
7. Disconnect the Chipset SATA cable from the system board and the hard drive backplane and remove
from the cable guide.
To replace the component, reverse the removal procedure.
HP Trusted Platform Module
The TPM is not a customer-removable part.
CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact an HP
authorized service provider for a replacement system board and TPM board.
the integrity of the system data.
Removal and replacement procedures 71
Page 72
Cabling
SAS hard drive cabling
• Hard drive cabling: 8 SFF, 25 SFF, 12 LFF
• Hard drive cabling: 16 SFF (8 SFF, with optional drive cage)
Cabling 72
Page 73
Optical drive cabling
FBWC cabling
• 8 or 16 drive SFF
• PCIe option
Cabling 73
Page 74
Depending on the server configuration, you may need to remove the primary PCI riser cage ("PCIe riser
cage (primary)" on page 32) before cabling to a PCIe expansion board.
Cabling 74
Page 75
Diagnostic tools
Troubleshooting resources
The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving
common problems and comprehensive courses of action for fault isolation and identification, issue resolution,
and software maintenance on ProLiant servers and server blades. To view the guide, select a language:
• English (http://www.hp.com/support/ProLiant_TSG_v1_en)
• French (http://www.hp.com/support/ProLiant_TSG_v1_fr)
• German (http://www.hp.com/support/ProLiant_TSG_v1_gr)
• Japanese (http://www.hp.com/support/ProLiant_TSG_v1_jp)
• Simplified Chinese (http://www.hp.com/support/ProLiant_TSG_v1_sc)
The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages
and information to assist with interpreting and resolving error messages on ProLiant servers and server
blades. To view the guide, select a language:
• English (http://www.hp.com/support/ProLiant_EMG_v1_en)
• French (http://www.hp.com/support/ProLiant_EMG_v1_fr)
• German (http://www.hp.com/support/ProLiant_EMG_v1_gr)
• Japanese (http://www.hp.com/support/ProLiant_EMG_v1_jp)
• Simplified Chinese (http://www.hp.com/support/ProLiant_EMG_v1_sc)
HP ROM-Based Setup Utility
RBSU is a configuration utility embedded in HP ProLiant servers that performs a wide range of configuration
activities that can include the following:
• Configuring system devices and installed options
• Enabling and disabling system features
• Displaying system information
• Selecting the primary boot controller
• Configuring memory options
• Language selection
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or
the HP website (http://www.hp.com/support/rbsu).
Diagnostic tools 75
Page 76
Integrated Management Log
The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event
with 1-minute granularity.
You can view recorded events in the IML in several ways, including the following:
• From within HP SIM
• From within the HP iLO user interface
USB support and functionality
USB support
HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by
the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB
devices through legacy USB support, which is enabled by default in the system ROM.
Legacy USB support provides USB functionality in environments where USB support is not available normally.
Specifically, HP provides legacy USB functionality for the following:
• POST
• RBSU
• Diagnostics
• DOS
Internal USB functionality
• Operating environments which do not provide native USB support
An internal USB connector is available for use with security key devices and USB drive keys. This solution
provides for use of a permanent USB key installed in the internal connector, avoiding issues of clearance on
the front of the rack and physical access to secure data.
External USB functionality
HP provides external USB support to enable local connection of USB devices for server administration,
configuration, and diagnostic procedures.
For additional security, external USB functionality can be disabled through RBSU.
Diagnostic tools 76
Page 77
Component identification
Front panel components
• SFF model (8-drive)
Item Description
1
2
3
4
5
Video connector
SATA optical drive bay
Drive bays
Systems Insight Display
USB connectors (2)
Front panel LEDs and buttons
Component identification 77
Page 78
Item Description Status
1
2
Power On/Standby button
and system power LED
Health LED Solid green = Normal
Solid green = System on
Flashing g reen (1 H z/cycl e per se c ) = Perfo r ming po w er on se quence
Solid amber = System in standby
Off = No power present*
Flashing amber = System degraded
Flashing red (1 Hz/cycle per sec) = System critical
Fast-flashing red (4 Hz/cycles per sec) = Power fault**
3
NIC status LED Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active
Off = No network activity
4
UID button/LED Solid blue = Activated
Flashing blue (1 Hz/cycle per sec) = Remote management or
firmware upgrade in progress
Off = Deactivated
*Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has
occurred, or the power button cable is disconnected.
**To identify components in a degraded or critical state, see the Systems Insight Display LEDs ("Systems Insight Display"
on page 45), check iLO/BIOS logs, and reference the server troubleshooting guide.
Systems Insight Display LEDs
The HP Systems Insight Display LEDs represent the system board layout. The display enables diagnosis with
the access panel installed.
Component identification 78
Page 79
A
A
A
A
A
A
A
A
Item Description Status
1
Power cap Off = System is in standby, or no cap is set.
Solid green = Power cap applied
2
3
4
—
NIC link/activity Off = No link to network. If the power is off,
view the rear panel RJ-45 LEDs for status
("Rear panel LEDs and buttons" on page
81).
Flashing green = Network link and activity
Solid green = Network link
Amber = Failure
For more information on the activation of
these LEDs, see "Systems Insight Display
LED combinations (on page 79)."
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health
event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the health LED
indicate system status.
Systems Insight Display
LED and color
Processor (amber)
Health LED System power
LED
Red
mberOne or more of the following conditions may
Status
exist:
• Processor in socket X has failed.
• Processor X is not installed in the socket.
• Processor X is unsupported.
• ROM detects a failed processor during
POST
Processor (amber)
DIMM (amber)
DIMM (amber)
Overtemperature (amber)
Overtemperature (amber)
Fan (amber)
Fan (amber)
mber GreenProcessor in socket X is in a pre-failure
condition.
Red GreenOne or more DIMMs have failed.
mber GreenDIMM in slot Xis in a pre-failure condition.
mber GreenThe Health Driver has detected a cautionary
temperature level.
Red
mber GreenOne fan has failed or has been removed.
Red GreenTwo or more fans have failed or been
mberThe server has detected a hardware critical
temperature level.
removed.
Component identification 79
Page 80
A
A
A
A
Systems Insight Display
LED and color
Power supply (amber)
Health LED System power
LED
Red
mber
Status
• Only one power supply is installed and
that power supply is in standby.
• Power supply fault
• System board fault
Power supply (amber)
mber Green
• Redundant power supply is installed and
only one power supply is functional.
• AC power cord is not plugged into
redundant power supply.
• Redundant power supply fault
• Power supply mismatch at POST or
power supply mismatch through hot-plug
addition.
Power cap (off)
Power cap (green)
Power cap (flashing
amber)
Power cap (green)
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required.
—
— Flashing greenWaiting for power
—
— GreenPower is available
mberStandby
mberPower cap has been exceeded
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Rear panel components
Item Description
1
2
3
4
5
6
7
8
PCIe slots 1–3 (top to bottom)
PCIe slots 4–6 (top to bottom)
Power supply 1 (PS1)
PS1 power connector
PS2 power connector
Power supply 2 (PS2)
USB connectors (4)
Video connector
Component identification 80
Page 81
9
10
11
iLO connector
Serial connector
FlexibleLOM ports (Shown: 4x1Gb/Optional: 2x10Gb); port 1 on right side
Rear panel LEDs and buttons
Item Description Status
1
2
3
4
5
UID LED/button Off = Deactivated
Solid blue = Activated
Flashing blue = System being managed remotely
Power supply 2
LED
Power supply 1
LED
Off = System is off or power supply has failed.
Solid green = Normal
Off = System is off or power supply has failed.
Solid green = Normal
NIC link LED Off = No network link
Green = Network link
NIC activity LED Off = No network activity
Solid green = Link to network
Flashing green = Network activity
Non-hot-plug PCI riser board slot definitions
• Primary riser cage connector, connected to processor 1 or the southbridge
PCIe slot descriptions
1 - FL/FH
2 - HL/FH
3 - HL/FH
• Secondary riser cage connector, connected to processor 2 (Processor 2 must be installed)
IMPORTANT: System board appearance and component location may vary.
Item Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Fan connector 6
Systems Insight Display connector
Fan connector 5
Processor 1 DIMM slots
Fan connector 4
Front I/O connector
Front USB connector
Fan connector 3
First drive cage, box 2 power connector
Fan connector 2
Processor 2 DIMM slots
Second drive cage, box 1 power connector
Fan connector 1
Discovery services connector
Front video connector
USB connector
Power supply backplane connector
SATA optical drive connector
NMI jumper
Component identification 83
Page 84
Item Description
20
21
22
23
24
25
26
27
28
29
30
31
32
System battery
SD card slot
Secondary (processor 2) PCI riser connector
System maintenance switch
Processor 2 socket
TPM connector
Primary (processor 1) PCI riser connector
FlexibleLOM
SAS connector 1
SAS connector 2
Cache module connector
Processor 1 socket
RDX power connector
System maintenance switch
Position Default Function
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
Off Off = HP iLO security is enabled.
On = HP iLO security is disabled.
Off Off = System configuration can be
changed.
On = System configuration is locked.
Off Reserved
Off Reserved
Off Off = Power-on password is enabled.
On = Power-on password is disabled.
Off Off = No function
To access the redundant ROM, set S1, S5, and S6 to on.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.
Component identification 84
Page 85
NMI functionality
An NMI crash dump enables administrators to create crash dump files when a system is hung and not
responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in operating
systems, device drivers, and applications. Many crashes freeze a system, and the only available action for
administrators is to cycle the system power. Resetting the system erases any information that could support
problem analysis, but the NMI feature preserves that information by performing a memory dump before a
hard reset.
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can use the iLO
Virtual NMI feature.
For more information, see the white paper on the HP website
(http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf).
DIMM slot locations
DIMM slots are numbered sequentially (1 through 12) for each processor. The supported AMP modes use the
letter assignments for population guidelines.
SAS and SATA device numbers
• SFF 8-device bay numbering
Component identification 85
Page 86
Hot-plug drive LED definitions
A
Item LED Status Definition
1
2
3
4
Locate Solid blue The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an update.
ctivity ring Rotating greenDrive activity
Off No drive activity
Do not remove Solid white Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off Removing the drive does not cause a logical drive to fail.
Drive status Solid greenThe drive is a member of one or more logical drives.
Flashing greenThe drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
Flashing amberThe drive is not configured and predicts the drive will fail.
Solid amberThe drive has failed.
Off The drive is not configured by a RAID controller.
The drive is a member of one or more logical drives and predicts
the drive will fail.
PCI riser cage LED
CAUTION: To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
Component identification 86
Page 87
Status
On = AC power is connected.
Off = AC power is disconnected.
FBWC module LEDs (P222, P420, P421)
The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the
reverse side of the cache module to facilitate status viewing.
1 - Amber 2 - Green 3 - Green Interpretation
Off
Off
Off
Off
Off OffThe cache module is not powered.
Flashing 0.5 Hz Flashing 0.5 HzThe cache microcontroller is executing from within its
boot loader and receiving new flash code from the host
controller.
Flashing 1 Hz Flashing 1 HzThe cache module is powering up, and the capacitor
pack is charging.
Off Flashing 1 HzThe cache module is idle, and the capacitor pack is
charging.
Component identification 87
Page 88
A
A
A
1 - Amber 2 - Green 3 - Green Interpretation
Off
Off
Off
Off
Flashing 1 Hz
Flashing 1 Hz
Flashing 1 Hz
Flashing 2 Hz
Flashing 2 Hz
On
On
Off OnThe cache module is idle, and the capacitor pack is
charged.
On OnThe cache module is idle, the capacitor pack is charged,
and the cache contains data that has not yet been
written to the drives.
Flashing 1 Hz Off
backup is in progress.
On OffThe current backup is complete with no errors.
Flashing 1 Hz OffThe current backup failed, and data has been lost.
Flashing 1 Hz On
power error occurred during the previous or current
boot. Data may be corrupt.
On Off
n overtemperature condition exists.
Flashing 2 Hz OffThe capacitor pack is not attached.
Flashing 2 Hz OnThe capacitor has been charging for 10 minutes, but
has not reached sufficient charge to perform a full
backup.
On OffThe current backup is complete, but power fluctuations
occurred during the backup.
On OnThe cache module microcontroller has failed.
Hot-plug fans
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1
The only two valid fan configurations are listed in the following table.
Configuration Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6
1 processor
2 processors
and 2 in a single-processor configuration.
Fan blank Fan blankFanFanFan Fan
Fan Fan FanFan Fan Fan
Component identification 88
Page 89
For a single-processor configuration, four fans and two blanks are required in specific fan bays for
redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan
causes an orderly shutdown of the server.
Installing more than the required number of fans in a single-processor configuration is not a supported
configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan causes
a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following
temperature-related scenarios:
• At POST and in the OS, HP iLO performs an orderly shutdown if a cautionary temperature level is
detected. If the server hardware detects a critical temperature level before an orderly shutdown occurs,
the server performs an immediate shutdown.
• When the Thermal Shutdown feature is disabled in RBSU, HP iLO does not perform an orderly shutdown
when a cautionary temperature level is detected. Disabling this feature does not disable the server
hardware from performing an immediate shutdown when a critical temperature level is detected.
CAUTION: A thermal event can damage server components when the Thermal Shutdown feature
is disabled in RBSU.
Storage and expansion diagram
Component identification 89
Page 90
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
Non-operating
Relative humidity
(noncondensing)
Operating
Non-operating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
10% to 90%
28°C (82.4°F), maximum wet bulb
temperature
For detailed power supply specifications, see the server QuickSpecs on the HP website
(http://h18000.www1.hp.com/products/quickspecs/14209_div/14209_div.html).
Specifications 90
Page 91
HP 1200W Common Slot Platinum Plus Hot Plug Power Supply
(94% efficiency)
Specification Value
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
Btus per hour
Power supply output
Rated steady-state power
Maximum peak power
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
9.1 A at 100 VAC
6.7 A at 200 VAC
897 W at 100V AC input
1321 W at 200V AC input
3408 at 120V AC input
4433 at 200V to 240V AC input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Specifications 91
Page 92
Acronyms and abbreviations
AMP
Advanced Memory Protection
FBWC
flash-backed write cache
FDR
fourteen data rate
FIO
Factory Integrated Option
FLR
FlexibleLOM for rack servers
FLR-SFP
FlexibleLOM for rack servers with an SFP+ connector
HP SIM
HP Systems Insight Manager
iLO
Integrated Lights-Out
IML
Integrated Management Log
LFF
large form factor
NEBS
Network Equipment-Building System
NMI
nonmaskable interrupt
Acronyms and abbreviations 92
Page 93
NVRAM
nonvolatile memory
PCIe
Peripheral Component Interconnect Express
POST
Power-On Self Test
QDR
quad data rate
RBSU
ROM-Based Setup Utility
SAS
serial attached SCSI
SATA
serial ATA
SFF
small form factor
SFP
small form-factor pluggable
TPM
Trusted Platform Module
UID
unit identification
USB
universal serial bus
Acronyms and abbreviations 93
Page 94
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the documentation,
send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com).
Include the document title and part number, version number, or the URL when submitting your feedback.
Documentation feedback 94
Page 95
Index
1
150W PCIe power cable 70
expansion boards 54, 55
expansion slot blanks 52, 54
extending server from rack 24
external USB functionality 76
A
AC power supply 37, 91
access panel 30
air baffle 30
fan cage 42
fans 41
FBWC cabling 73
FBWC module 87
FBWC procedures 48, 51
features 77
flash-backed write cache capacitor pack 50
flash-backed write cache module 48
flash-backed write cache procedures 48, 51
FlexibleLOM 43
front panel assembly 46
front panel buttons 77
front panel components 77
front panel LEDs 77
full-length expansion board 27, 55
H
hard drive bays 77
hard drive blanks 35
hard drive cage 45
hard drive LEDs 86
hard drives, determining status of 86
health LEDs 77
heatsink 56
hot-plug fans 26, 88
HP technical support 5
rear panel, accessing 26
recovering the data from the cache 51
removal and replacement procedures 23
removing server from rack 25
S
safety considerations 28
SAS and SATA device numbers 85
spare part numbers 15, 18
specifications 90, 91
specifications, environmental 90
specifications, mechanical 90
specifications, power 90, 91
specifications, server 90
static electricity 28
storage overview 89
switches 85
symbols on equipment 28
system battery 63
system board components 83
system board replacement 64
system components 18, 77
system maintenance switch 84, 85
system power LED 77
Systems Insight Display 45, 78, 79
Systems Insight Display LEDs 78, 79
part numbers 15
PCI riser board definitions 81
PCIe riser blank 32
PCIe riser board 34
PCIe riser cage 32, 33
plastics kit 15
POST error messages 75
power cables 70
power supply 37
power supply backplane 40
power supply blank 36
power supply LEDs 81
power supply specifications 90, 91
powering down 23
preparation procedures 23
processors 58