HP BL30p User Manual

QuickSpecs

Overview

HP ProLiant BL30p Server Blade
ProLiant BL30p Server Blades Installed in Server Blade Enclosure
1.
ProLiant BL30p Server Blades (16)
2.
ProLiant BL p-Class interconnects (2) (patch panel 2 shown)
What's New
ProLiant BL30p -- A new high density, dual-processor capable server blade for the ProLiant BL p-Class An enhanced, fully backwards-compatible server blade enclosure featuring support for the new BL30p series server blades and all current and future BL20p series and BL40p series blades New enclosure with enhanced backplane components features Integrated Light-Out (iLO) management cable consolidation iLO provides new feature for automatically assigning static IP addresses for blades New dual power input option kit allows support for two power enclosures on mini bus bars
DA - 11958 North America — Version 6 — September 24, 2004
Page 1
QuickSpecs
HP ProLiant BL30p Server Blade
Overview
At A Glance
Maximum density ProLiant BL30p server blade
Up to two Intel Xeon 3.2-GHz/533-MHz with 2MB L3 cache processors with Hyper-Threading Technology ServerWorks GC-LE chipset 1024-MB PC2100-MHz Registered ECC DDR memory (1 x 1-GB), expandable to 4-GB, flex memory supports interleaved and non­interleaved memory configurations Integrated Lights-Out (iLO) Advanced Pack with new static IP bay configuration feature Two (2) NC7781 PCI-X Gigabit NICs (embedded) One 10/100T NIC (embedded) dedicated to iLO management Supports up to two optional small form factor ATA 60-GB hard drives BIOS-Enhanced RAID for Linux enables both primary and secondary hard drives to be bootable Dual-Port Fibre Channel Adapter (2-Gb) option for SAN connectivity BL30p plugs vertically into blade sleeve and sleeve plugs into 6U blade enclosure Local I/O cable attaches to front of blade and provides two USB ports, one video port, one iLO port and serial port Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and Common Procedures guides Up to 96 BL30p blades fit in 42U rack in non-redundant power configuration; up to 80 BL30p blades fit in 42U in full power redundant configuration
ProLiant BL p-Class Server Blade Enclosure with Enhanced Backplane Components
Updated to support the new BL30p blade and be fully compatible with all current and future BL20p series and BL40p series blades Blade iLO signals are physically consolidated to an RJ-45 port on the server blade management module Option kit available for field upgrade of backplanes to existing, deployed blade enclosures Each server blade enclosure is 6U and holds up to 16 ProLiant BL30p server blades (BL30p blade sleeve is required for each pair of BL30p blades installed) Interconnect options for network signal routing include GbE Interconnect Switches, GbE2 Interconnect Switches with optional Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through
ProLiant BL p-Class Power Enclosure
BL p-Class rack-centralized power enclosure holds hot-plug power supplies Use BL p-Class sizing tool to determine power and cooling requirements based on your desired configuration:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
3 phase power enclosure highly recommended for BL30p deployments BL p-Class power enclosure not needed if using facility -48VDC ± 10% (DC option kit required)
ProLiant BL p-Class Power Distribution
Carries power from the power enclosure(s) to the server blade enclosures Three power distribution choices: mini bus bars (support up to 3 blade enclosures) scalable bus bars (support up to 5 blade enclosures) power bus box (supports a single blade enclosure)
New dual power input option kit allows support for two power enclosures on mini bus bars BL p-Class server blades, server blade enclosures, interconnects and power enclosures protected by a limited three year warranty with optional service uplifts available.
which they are installed.
NOTE:
Power requirements for a ProLiant BL p-Class system: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
NOTE:
All ATA hard drives offered by HP carry a one year warranty regardless of the base system in
DA - 11958 North America — Version 6 — September 24, 2004
Page 2
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
ProLiant BL30p Server Blade
+
ProLiant BL30p Blade Sleeve (holds 2 BL30p blades)
+
DA - 11958 North America — Version 6 — September 24, 2004
Page 3
QuickSpecs
Overview
BL p-Class Server Blade Enclosure with enhanced backplane components
HP ProLiant BL30p Server Blade
+
OR
Patch Panel (shown) or
Patch Panel 2
BL p-Class Interconnects
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch
+
BL p-Class power enclosure(s) and power supplies (three phase recommended)
+
OR
Facility DC
(fiber- or copper-based)
DA - 11958 North America — Version 6 — September 24, 2004
Page 4
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
OR OR
Mini bus bars
Scalable bus bars
BL p-Class power distribution
Bus boxes
Configuration Steps
For a complete ProLiant BL30p blade solution, do the following:
Select desired model, configuration and quantity of ProLiant BL30p server blades
1.
PLUS
Determine how many BL30p blade sleeves are required. Each BL30p blade sleeve holds two BL30p server blades and one server blade
2. enclosure holds up to eight sleeves.
PLUS
3. Determine how many BL p-Class Server Blade Enclosures with enhanced backplanes are required. Each blade enclosure with enhanced
3. backplanes can hold up to 16 ProLiant BL30p server blades.
NOTE:
ProLiant BL p-Class server blade enclosures with enhanced backplane components are required to support BL30p server blades.
Server blade enclosures with enhanced backplanes can be purchased with licenses for Rapid Deployment Pack: BL p-Class server blade enclosure with enhanced backplanes with 8 Rapid Deployment Pack licenses (281404-B22) or BL p-Class server blade enclosure with enhanced backplanes with Rapid Deployment Pack trial (243564-B22)
PLUS
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects. One interconnect kit is required with each server blade enclosure: RJ-45 Patch Panel 2 with Fibre Channel pass through. This is the required patch panel model for Fibre Channel connectivity on BL30p (306465-B21). or
DA - 11958 North America — Version 6 — September 24, 2004
Page 5
QuickSpecs
HP ProLiant BL30p Server Blade
Overview
RJ-45 Patch Panel (230766-B21) or BL p-Class C-GbE2 Interconnect Kit (with 12 RJ-45 10/100/1000 T/TX/T external ports) (283192-B21) with or without optional ProLiant BL p­Class GbE2 Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BL30p Fibre Channel connectivity when using the GbE2 Interconnect Switch) or BL p-Class F-GbE2 Interconnect (with 8 LC 1000 SX and 4 RJ-45 10/100/1000 T/TX/T external ports) (283193-B21) with or without optional ProLiant BL p-Class GbE2 Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BL30p Fibre Channel connectivity when using the GbE2 Interconnect Switch) or BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T and 8 RJ-45 10/100 T/TX external ports (249655-B21) or BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX and 8 RJ-45 10/100 T/TX external ports) (279720-B21)
PLUS
Select BL p-Class power enclosure(s) and power supplies based on configuration.
5.
NOTE:
3 phase power enclosure options are highly recommended for deployments of BL30p server blades. Use the ProLiant BL p-Class sizing utility to help determine power configuration:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls .
NOTE:
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
3 phase power enclosure with six power supplies (3 phase power enclosure holds six power supplies) (NA/JPN- 230769-001) (INTL ­230769-421) (Power enclosures and supplies can also be purchased separately see options list)
PLUS
Select power distribution option:
6. Mini bus bars (support up to 3 server blade enclosures) (240559-B21). Note that two mini-bar configurations can be stacked to fill a 42U rack. or Scalable bus bars (support up to 5 server blade enclosures) (240560-B21) or Power Bus Box (supports a single server blade enclosure) (240562-B21)
DA - 11958 North America — Version 6 — September 24, 2004
Page 6
QuickSpecs
Overview
ProLiant BL p-Class Server Blade Enclosures with Enhanced Backplanes Installed in 42U Rack
Redundant Power Configuration (left) and Non-Redundant Power Configurations (right)
HP ProLiant BL30p Server Blade
1. Power Enclosure
DA - 11958 North America — Version 6 — September 24, 2004
Page 7
QuickSpecs

Standard Features (Server Blade)

HP ProLiant BL30p Server Blade
Processor
Upgradeability
Cache Memory
One of the following depending on Model
Chipset
Memory
Network Adapter
Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache
BL30p Server Blade is dual-processor capable
2-MB Level 3 cache 1-MB Level 3 cache 512-KB Level 2 cache
ServerWorks GC-LE chipset
NOTE:
For more information regarding the ServerWorks chipset, see the following website:
http://www.serverworks.com/products/overview.html
Standard
Maximum Flex Memory
Three (3) network adapters total: Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE One 10/100T NIC (embedded) dedicated to iLO management
1024-MB (1 x 1-GB) PC2100 DDR SDRAM running at 266MHz; non-interleaved unless a second DIMM option installed 287497-B21
4-GB BL30p blade supports memory interleaving when an identical pair of DIMMs is installed
Integrated Manageability
Internal Storage
Integrated Lights-Out (iLO) Management Advanced Pack with new static IP bay configuration feature
Hard Drives Maximum Internal Storage
None ship standard 120-GB (2 x 60-GB small form factor ATA, 5400 RPM hard drives)
DA - 11958 North America — Version 6 — September 24, 2004
Page 8
QuickSpecs
Standard Features (Server Blade)
HP ProLiant BL30p Server Blade
Fiber Channel on the ProLiant BL30p
The following items are needed to connect the ProLiant BL30p to a SAN via Fibre Channel:
1. ProLiant BL30p blade with Dual-Port Fibre Channel Adapter (option) installed The Dual-Port Fibre Channel Adapter option 354054-B21 is compatible with the ProLiant BL30p blade (not
compatible with ProLiant BL20p series blades) Two ports on each configured blade provide redundant Fibre Channel connections Supports up to 2 Gb/s and backward compatible with existing 1 Gb/s Fibre Channel equipment Based on the QLogic ISP2312 chipset Kit includes two small form factor pluggable transceivers with LC connectors for installation into the interconnect option kit (see 2A and 2B below)
AND
2A. RJ-45 Patch Panel 2 (with Fibre Channel pass through) interconnect option
Enables pass through of both Ethernet and Fibre Channel signals Ethernet signals exit the rear of the RJ-45 Patch Panel 2 interconnects Fibre Channel signals exit the front of the RJ-5 Patch Panel 2 interconnects
8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2 interconnect (16 Fibre Channel SPF transceiver cages per server blade enclosure) SPF transceivers are included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
OR
2B. C-GbE2 or F-GbE2 Interconnect Kit plus the GbE2 Storage Connectivity Kit (option)
Enables Ethernet signal consolidation and pass through of Fibre Channel signals Both Ethernet and Fibre Channel signals exit the rear of the GbE2 Interconnect Switch (with the GbE2 Storage Connectivity Kit option)
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each GbE2 Interconnect Switch (16 Fibre Channel SPF transceiver cages per server blade enclosure) SPF transceivers included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
Local I/O Cable
AND
3. Compatible SAN Optimized for StorageWorks arrays:
Modular Smart Array 1000 Enterprise Virtual Array 5000 (EVA5000) V2; Enterprise Virtual Array 3000 (EVA3000)
XP48, 128, 512, 1024; Compatible with select 3rd party SANs. Refer to blade storage website for details:
http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/storage.html
Connects to the front of BL30p server blade for local management and aid in first server blade configuration Two (2) USB ports, one (1) video port, one (1) iLO port and one (1) serial port Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components (281404-B22
and 243564-B22)
NOTE:
Tested USB devices (keyboard, mouse, floppy) are listed in options section below.
DA - 11958 North America — Version 6 — September 24, 2004
Page 9
QuickSpecs
HP ProLiant BL30p Server Blade

Standard Features (Server Blade Enclosure and Interconnects)

ProLiant BL p-Class Server Blade Enclosure and Interconnects
ProLiant BL p-Class Server Blade Enclosure
6U (10.5-inch), 19-inch wide Holds up to:
Eight (8) ProLiant BL20p series server blades Sixteen (16) ProLiant BL30p series server blades (BL30p blade sleeves required) Two (2) ProLiant BL40p series server blades A combination of the above
NOTE:
ProLiant BL p-Class server blade enclosures with enhanced backplane components are required to support
BL30p server blades.
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL30p series blades and provide a single, physical iLO port for the enclosure.
Two (2) outside bays for interconnects (Patch Panel, Patch Panel 2, GbE Interconnect Switch, or GbE2 Interconnect Switch)
Server blade management module on the rear of the server blade enclosure is hot-plug, has a centralized 10/100T iLO port for all installed blades, reports events of all installed blades and provides asset and inventory information via SNMP.
ProLiant BL p-Class Power Requirements
Redundant 208V 30amp 3-phase 4 wire, NA Redundant 380 - 415V 20A 3-phase 5 wire, Intl
NOTE:
3 phase power highly recommended for BL30p deployments.
Redundant 200V - 240V AC, 30 amp single-phase for NA and International Redundant -48VDC ± 10%
DA - 11958 North America — Version 6 — September 24, 2004
Page 10
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class Interconnect Switch Option
(A pair of switches per kit)
(Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches)
Interconnect Switch interconnects consolidate the Ethernet signals from the server blades to a smaller set of external copper-based or fiber-based uplink ports for connection to the network infrastructure. Like the Patch Panel interconnects, an option is also available to pass through individual BL20p G2 and BL30p Fibre Channel signals.
The interconnect switches provide up to a 32-to-1 server network cable reduction per server enclosure depending on the mix of BL20p series, BL30p series, and BL40p series blades. Each interconnect switch pair reduces up to sixteen internal server network (NIC) ports to one to six external ports (four on a modular rear mounting interconnect and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) provide NIC consolidation to 1000 Mbps (Gigabit Ethernet), advanced network feature support including layer 3-7 switching, Fibre Channel pass-through (for BL20p series and BL30p series blades), and 10 Gigabit Ethernet bandwidth connectivity to the network. Expandability of both layer 3-7 switching and 10 Gigabit Ethernet is planned with future GbE2 Interconnect Switch upgrade options available through Nortel Networks.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure. The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure. The optional ProLiant BL p-Class GbE2 Storage Connectivity Kit (321745 -B21) is required for Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) provide NIC consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port Redundant crosslink ports connecting the two interconnect switches Redundant power inputs and on-board redundant fans Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Power ON, management, and per port status and speed LED indicators Reset/power momentary push-button switch HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external
ports per server blade enclosure. ProLiant BL Interconnect Switch Management System and Utilities: Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user
accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto­negotiation and auto-sensing of speed and duplex mode, and more.
DA - 11958 North America — Version 6 — September 24, 2004
Page 11
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class GbE2 Storage Connectivity Kit Option
(supports a pair of GbE2 switches)
ProLiant BL p-Class RJ-45 Patch Panel
(A pair of patch panels provided per kit)
(Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches)
ProLiant BL p-Class RJ-45 Patch Panel 2
Channel pass through)
(A pair of patch panels provided per kit)
(Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches)
NOTE:
Either Patch Panel 2 or a GbE2 Interconnect Kit is required for SAN connectivity with BL20p series and BL30p series blades.
(with Fibre
The GbE2 Storage Connectivity Kit (option) is required for Fibre Channel signal pass-through when using a GbE2 Interconnect Switch Kit. Both Ethernet cable consolidation and Fibre Channel connectivity is possible using a single interconnect option. Order one GbE2 Storage Connectivity Kit per server blade enclosure for Fibre Channel pass through of BL20p and BL30p series blades. The GbE2 Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver cages for the pluggable small form factor transceivers that come with each BL30p Dual-Port Fibre Channel Adapter (option) and each BL20p Dual Port Fibre Channel Adapter. The GbE2 Storage Connectivity Kit supports up to eight BL20p series, up to sixteen BL30p series blades or combinations thereof.
6U (10.5-inch), plugs into BL p-Class 6U server blade enclosures. Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. Supports Gigabit Ethernet network adapters. 16 RJ-45 connectors on the back of each RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure). The benefits to the RJ-45 Patch Panel are that it:
- Allows the customer to connect signals to their own LAN infrastructure components.
- Provides very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
6U (10.5-inch), plugs into BL p-Class 6U server blade enclosures. Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections. Supports Gigabit Ethernet network adapters. 16 RJ-45 connectors on the back of each RJ-45 Patch Panel 2 (32 RJ-45 connections per server blade enclosure). Passes through Fibre Channel signals, from all installed BL20p and BL30p series server blades, individually out
through small form factor pluggable (SPF) transceiver cages. Supports 2 Gb/s Fibre Channel signals and backward compatible with existing 1 Gb/s Fibre Channel equipment. 8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2 (16 Fibre
Channel SPF transceiver cages per server blade enclosure). The benefits to the RJ-45 Patch Panel 2 are that it:
- Allows the customer to connect signals to their own LAN and SAN infrastructure components.
- Provides a very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
- Electrically isolates the Ethernet and Fibre Channel signals from each other.
ProLiant BL p-Class Fibre Channel pass through
Fibre Channel signals travel from a ProLiant BL20p series and/or BL30p series blades through the server blade enclosure backplane. Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 or GbE2 Interconnect Switch (with GbE2 Storage Connectivity Kit) in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals; one Fibre Channel signal terminates through the right interconnect, the other Fibre Channel signal terminates through the left interconnect.
Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45 Patch Panel 2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server blade enclosure). The SPF cages are used for insertion of SPF transceivers included with the BL20p G2 Dual-port Fibre Channel Mezzanine Card and the BL30p Dual-Port Fibre Channel Adapter.
DA - 11958 North America — Version 6 — September 24, 2004
Page 12
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
Required Network Cabling
10Base-T
100Base-TX
1000Base-T
1000Base-SX
NOTE:
For cabling information, refer to the website at:
Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
http://www.hp.com/go/servers/
.
DA - 11958 North America — Version 6 — September 24, 2004
Page 13
QuickSpecs

Standard Features (Power System and Rack Information)

HP ProLiant BL30p Server Blade
ProLiant BL p-Class Power System and Rack Information
ProLiant BL p-Class Power Enclosure
BL p-Class Power Distribution
Scalable Bus Bar Mini Bus Bar Power Bus Box
Required Power Source
NOTE:
To determine power configuration, please refer to the ProLiant BL p-Class Overview and Planning Whitepaper
and sizing utility at
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), dual input single phase and three phase models available.
BL p-Class power enclosure provides scalable rack-centralized, hot-plug power without the need for PDUs. Each 3 phase power enclosure houses six hot-plug power supplies Each single-phase power enclosure holds four hot-plug power supplies Please use the sizing utility to determine the power needed for each configuration
http://h30099.www3.hp.com/configurator/powercalcs.asp
NOTE:
3 phase power enclosure options highly recommended for BL30p deployments.
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, Facility DC Power Connection kit (240563-B21) is needed.
-48 VDC power (from the power enclosures or facility DC power) is carried from the power enclosures to the server blade enclosures through bus bars (for multiple enclosures) or power bus boxes (for a single enclosure). Hinges attach the bus bars to the rack rails and provide easy rear access to the blade enclosures and interconnects. Power is distributed through independent A- and B-sided bus bars.
Three power distribution solutions are available depending on the size of the intended deployment (see table).
Power Enclosures Supported
NOTE*:
Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.
NOTE:
To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars.
Two 30-Amp redundant power feeds per power enclosure Connectors:
http://www.hp.com/products/servers/proliant-bl/p-class/info/
Server Blade Enclosures
Supported
1 or 2
1 or 2*
1 1
up to 5 up to 3
.
Max. Rack Space Occupied
36U 24U
9U
NEMA receptacles
1. NA 1-phase L6-30, 250v, 30A 3-wire NA 3-phase L15-30, 250V, 30A, 4-wire
For cabling information, refer to the website at:
http://www.hp.com/go/servers/
DA - 11958 North America — Version 6 — September 24, 2004
Page 14
QuickSpecs

Standard Features (Manageability)

HP ProLiant BL30p Server Blade
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server
ProLiant Essentials Rapid Deployment Pack
HP Systems Insight Manger
Management Agents
Subscriber's Choice
ROMPaq, support software, and configuration utilities
Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant Integration Module featuring ProLiant server pre-configured events for OS installation, and optimized software drivers, firmware and management agents. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each server deployed and are available for purchase with blade servers. For more information, visit
HP Systems Insight Manager (HP SIM) help maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM is easy to set up to work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP Systems Insight Manager customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP Systems Insight Manager visit
The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in-depth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available in the RDP CD, SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at
http://www.hp.com/servers/smartstart
http://www.hp.com/servers/rdp
http://www.hp.com/go/hpsim
.
http://www.hp.com/go/subscriberschoice
.
.
.
Optional ProLiant Essentials Value Packs
Survey Utility and diagnostics utilities
NOTE:
For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server. Performance Management Pack - identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources.
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials
more information.
The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart.
or the various ProLiant Essentials Value Pack product QuickSpecs for
DA - 11958 North America — Version 6 — September 24, 2004
Page 15
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
SmartStart
OS Support
Intelligent Manageability
SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and consistent server configurations. SmartStart 7.00 and later can now deploy the ProLiant BL20P G3 and ProLiant BL40P servers, using the I/O port with an attached USB CD-ROM device. To obtain a copy of SmartStart for your blade server, redeem the coupon that is included with your Blade server or order your copy from the SmartStart web site. For more information, please visit the SmartStart Web site at SmartStart version supported (minimum): SmartStart 6.20
Microsoft® Windows® LINUX
NOTE:
For a more complete and up-to-date listing of supported operating systems and versions, please visit our OS Support Matrices website:
NOTE:
For an up-to-date listing of the latest drivers available for the ProLiant BL p-Class, please visit the support
website:
Integrated Lights-Out (iLO) Advanced Pack
http://www.hp.com/products/servers/proliant-bl/p-class/info/
Static IP bay configuration -- new feature for ProLiant BL p-Class blades Virtual Text and Graphical Remote Console Virtual CD-ROM and Virtual Floppy Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for 12 user accounts with customizable access privileges
http://www.hp.com/go/ossupport
http://www.hp.com/servers/smartstart
.
NOTE:
For more information on iLO Advanced visit the website:
Automatic Server Recovery-2 (ASR-2) Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (Interconnect Switch option) Integrated Management Log (IML) Off-Line Backup Processor capability Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Network adapter teaming set-up utility
http://www.hp.com/servers/ilo/
DA - 11958 North America — Version 6 — September 24, 2004
Page 16
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
ProLiant BL p-Class Availability Features
Power redundancy:
hot-plug power supplies redundant AC feeds (requires two power enclosures when using blade enclosures with enhanced backplane components) interconnects options and server blade management module share power from both A- and B- side
power buses Dual-Port Fibre Channel Mezzanine Card for redundant SAN connections Redundant ROM on each server blade ECC Memory Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing)
Interconnect Switch availability features:
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Two network connections per BL30p server blade routed to independent interconnect switches Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports per each interconnect switch Redundant front panel ports per each interconnect switch for diagnostics, management, and additional uplinks Redundant serial ports Compatibility with PVST+ (GbE2 switch) and 802.1D Spanning tree protocol support for loop-free path redundancy Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and failover Redundant configuration files and operating system firmware images in memory (GbE2 switch) Redundant fans per each interconnect switch Redundant power to each interconnect switch Support for ProLiant network adapter teaming Redundant configurable community strings and SNMP trap manager hosts Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
Security
Minimum Rack Requirements
Power-on password Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction
NOTE*:
GbE2 Interconnect Switch only
Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
Compatible with 19-inch Standard EIA rail sets EIA rail-to-rail depth is 29 - 30" Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear RETMA rail to rear door, inclusive in the 36-inch overall depth) Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration with patch panel) Must be capable of supporting 1600 lb (for full rack configuration) Perforated front and rear doors to accommodate front-to-back cooling Must have 65% open perforation on server blade enclosure doors to support airflow requirements Optimized for use with the HP 10000 Series racks
NOTE:
If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required.
DA - 11958 North America — Version 6 — September 24, 2004
Page 17
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
Rack Airflow Requirements
Service and Support
HP 10000 series racks provide enhanced airflow for maximum cooling, allowing racks to be fully loaded with servers and server blades using the latest server technologies.
CAUTION:
to prevent damage to the equipment:
CAUTION:
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE:
server, or to the server documentation located in the Support section on the ProLiant BL30p website:
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services.
NOTE: NOTE:
site support.
If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement
For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the
http://www.hp.com/servers/bl30p
Sever Blade Limited Warranty includes 3 year Parts, 1 year Labor, 1-year on-site support.
Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-
.
Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up Education courses Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare­based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours. System Management, Performance Services and Mission Critical Support Solution
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or
visit our worldwide Web site on the internet at:
NOTE:
For more complete information on HP Services offerings, customers and resellers, please visit us at:
http://www.hp.com/hps
NOTE:
Additional information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
http://www.hp.com/hps/carepack
DA - 11958 North America — Version 6 — September 24, 2004
Page 18
QuickSpecs

Models

HP ProLiant BL30p Server Blade
ProLiant BL30p X3.2-2MB, 1GB (2P)
360329-B21
ProLiant BL30p X3.2-1MB, 1GB (2P)
368271-B21
Processor(s) Cache Memory Memory
Network Adapter
Hard Drives Internal Storage Optical Drive I/O cable Form Factor
Processor(s) Cache Memory Memory
Network Adapter
Hard Drives Internal Storage Optical Drive Form Factor
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) 2-MB Level 3 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB); 2-way interleaved when an identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) None Included Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components.
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) 1-MB Level 3 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB); 2-way interleaved when an identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) None Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components.
ProLiant BL30p X3.06/533MHz-512KB, 1GB (2P)
354566-B21
Processor(s) Cache Memory Memory
Network Adapter
Hard Drives Internal Storage Optical Drive Form Factor
Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported) 512-KB Level 2 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266MHz (1
x 1-GB), 2-way interleaved when an identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) 2 x 60-GB None Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components.
DA - 11958 North America — Version 6 — September 24, 2004
Page 19
QuickSpecs
Models
HP ProLiant BL30p Server Blade
ProLiant BL30p X3.06/533MHz-512KB, 1GB (1P)
354050-B21
ProLiant 3.2-GHz BL30p Server Blade Multi-Pack
368272-B21
NOTE:
Multi-pack contains 8 BL30p server blades, 4 BL30p blade sleeves and 8 licenses for Rapid Deployment Pack.
Processor(s) Cache Memory Memory
Network Adapter
Hard Drives Internal Storage Optical Drive Form Factor
Processor(s)
Cache Memory Memory
Network Adapter
Hard Drives Internal Storage
One (1) Intel Xeon 3.06-GHz standard (up to 2 supported) 512-KB Level 2 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when an identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) None Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components.
Each blade is configured with Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported)
2-MB Level 3 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
ProLiant 3.06-GHz BL30p Server Blade Multi-Pack
354051-B21
NOTE:
Multi-pack contains 8 BL30p server blades, 4 BL30p blade sleeves and 8 licenses for Rapid Deployment Pack.
Processor(s)
Cache Memory Memory
Network Adapter
Hard Drives Internal Storage
Each blade is configured with Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported)
512-KB Level 2 writeback per processor 1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when identical pair installed Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management None ship standard Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
DA - 11958 North America — Version 6 — September 24, 2004
Page 20
QuickSpecs
HP ProLiant BL30p Server Blade

Configuration Information - Factory Integrated Models

NOTE:
HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
Step 1: Base Server Blade Configuration
Model
Step 2: Choose Required Options (only one of the following from each list unless otherwise noted)
Processor
HP ProLiant BL30p Configurable Model Configurable Model ships with:
- Two embedded NC7781 PCI-X Gigabit NICs plus one 10/100T NIC for iLO
- Integrated Lights-Out (iLO) Management with Advanced Pack features
For single processor configuration choose:
Xeon 3.06GHz/533-512 FIO Base
For dual-processor configurations choose two each of:
Xeon 3.06GHz/533-512 FIO Base Xeon 3.2GHz/533-1M FIO Xeon 3.2GHz/533-2MXeon 3.2GHz/533-2M FIO
NOTE:
Dual-processor configurations must have a matching pair of CPUs. Mixed clock speeds
are not supported.
367243-405
354053-L21
354053-L21 368273-B21 364306-B21
Memory
NOTE:
Two-way interleaving memory is enabled when an identical pair of DIMMs is installed.
For 1GB Total Memory choose A or B:
A) 2 x 512 MB PC2100 DDR SDRAM DIMMs B) 1 x 1GB PC2100 DDR SDRAM DIMM
For 2GB Total Memory both A and B are required:
A) 1 x 1GB PC2100 DDR SDRAM DIMM B) 1 x 1GB PC2100 DDR SDRAM DIMM
For 4GB Total Memory:
2 x 2048MB PC2100 DDR SDRAM DIMM 2x2048
Step 3: Choose Additional Options for Factory Integration
Hard Drive Fibre Channel Option
60GB Small Form Factor ATA Hard Drive, 5400 rpm BL30p Dual Port Fibre Channel Adapter
NOTE:
For additional options, including BL30p blade sleeve, server blade enclosure with enhanced backplanes, interconnect options and power subsystem options, please refer to the "Options" section below.
300679-B21
287497-L21
287497-L21
287497-B21
300682-B21
354052-B21 354054-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 21
QuickSpecs
HP ProLiant BL30p Server Blade

Options

NOTE:
Some options may not be factory integratable. Please contact your local sales representative for additional information.
Unique Options
ATA Hard Drive Kit for ProLiant BL30p, 2.5" parallel ATA drive, 60GB, 5400 rpm (option) ProLiant BL30p Blade Sleeve Kit (option)
NOTE:
Each blade sleeve supports one or two BL30p server blades.
354052-B21 354101-B21
ProLiant BL30p Dual-Port Fibre Channel Adapter
ProLiant Essentials Value Pack Software
Dual-Port Fibre Channel Adapter (2-Gb) Kit (option) for ProLiant BL30p
NOTE:
When using this card, Patch Panel 2 or a GbE2 Interconnect Switch Kit (with GbE2
Storage Connectivity Kit) must be used to provide pass through of the Fibre Channel signals.
Rapid Deployment Pack, 10 User, V1.x
NOTE:
The above licenses allow 10 servers to be managed and deployed via the Deployment
Server.
NOTE:
Not necessary if you purchase the BL30p Multi-Pack (354051-B21) or server blade
enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE:
Rapid Deployment pack is now available in a Linux Edition for Linux-only environments.
Rapid Deployment Pack, 1 User, V1.x
NOTE:
The above licenses allow 1 server to be managed and deployed via the Deployment
Server.
NOTE:
Not necessary if you purchase the BL30p Multi-Pack (354051-B21) or server blade
enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE:
Rapid Deployment pack is now available in a Linux Edition for Linux-only environments.
Flexible Quantity License Kit License-Only - for use with a Master License Agreement ProLiant Essentials Intelligent Networking Pack, Single Server License
NOTE:
For use with a single server. Contains one license with a unique license activation key and documentation.
ProLiant Essentials Intelligent Networking Pack, Flexible License
NOTE:
For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation.
ProLiant Essentials Intelligent Networking Pack, Tracking License
NOTE:
For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement.
NOTE:
Nothing is delivered in conjunction with the purchase of this part number. Visit
http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html
for more information on Activation Key Agreements.
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning Manager version 2.0)
NOTE:
For more information regarding ProLiant Essentials Software, please see the following
URL: http://hp.com/servers/proliantessentials
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL Value Pack product QuickSpecs for more information.
http://hp.com/servers/proliantessentials
.
or the various ProLiant Essentials
354054-B21
269817-B21
267196-B21
302127-B21 302128-B21 372906-B21
372950-B21
372951-B21
303284-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 22
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Processor
Memory
(SDRAM DIMMs)
BL p-Class Server Blade Enclosures with enhanced backplane components
Intel Xeon 3.06-GHz / 512-KB cache Processor Kit (option)
NOTE:
There is no option kit offered for the ProLiant BL30p with Intel Xeon 3.2GHz processor because all models ship with two processors installed.
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2-GB) 1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1-GB)
NOTE:
This DIMM option is an identical match to the DIMM installed on the BL30p base model and
therefore provides 2-way interleaving when installed on a base model BL30p blade.
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512-MB)
ProLiant BL p-Class Server Blade Enclosure (includes enhanced backplane components) ProLiant BL p-Class Server Blade Enclosure with eight (8) ProLiant Essentials Rapid Deployment
Pack Licenses (includes enhanced backplane components)
NOTE:
ProLiant BL p-Class server blade enclosures with enhanced backplane components are required to support BL30p server blades.
ProLiant BL p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL30p series blades and provide a single, physical iLO port for the enclosure.
354053-B21
300682-B21 287497-B21
300679-B21
243564-B22 281404-B22
354100-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 23
QuickSpecs
Options
HP ProLiant BL30p Server Blade
BL p-Class Interconnects
ProLiant BL p-Class Patch Panel 2 Kit with Fibre Channel pass-through (pair)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class Patch Panel (pair)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class GbE2 Storage Connectivity Kit (with pair of OctalFC Interconnect Modules and two Fibre Channel signal conditioning cards)
NOTE:
Required for BL30p Fibre Channel signal pass through when using the GbE2 Interconnect Switch.
NOTE:
Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit.
ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that a Patch Panel Kit or GbE2 Interconnect Switch Kit option be used if server NIC speeds to 1000 Mbps are required.
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that a Patch Panel Kit option be used if server NIC speeds to 1000 Mbps are required.
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
306465-B21
230766-B21
283192-B21
283193-B21
321745 -B21
249655-B21
279720-B21
BL p-Class Power Options
NOTE:
Use p-Class sizing tool to help determine power configuration:
http://h30099.www3.hp.com/configurator/powercalcs.asp
Single Phase Redundant Power Enclosure with 4 power supplies (Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)
3 Phase Redundant Power Enclosure with 6 power supplies (3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit)
Single Phase Power Enclosure (empty) (Holds up to 4 power supplies; power supplies are not included in this kit)
3 Phase Power Enclosure (empty) (Holds up to 6 power supplies; power supplies are not included in this kit)
Single Power Supply Facility DC Power Connection
DA - 11958 North America — Version 6 — September 24, 2004
239162-001
230769-001
231710-001
231709-001
239161-B21 240563-B21
Page 24
QuickSpecs
Options
HP ProLiant BL30p Server Blade
ProLiant BL p-Class Power Distribution
ProLiant BL p-Class Other Options
Tape Libraries
Scalable Bus Bar Mini Bus Bar Dual Power Input Kit for Mini Bus Bar Power Bus Box
Diagnostic Station ProLiant BL p-Class Server Enclosure Shipping Bracket Option Kit
NOTE:
Used to secure one server blade enclosure in a rack when moving.
ProLiant BL p-Class Power Enclosure Shipping Bracket Option Kit
NOTE:
Used to secure one power enclosure in a rack when moving.
Bus Bar Telco Rack Kit Enclosure Telco Rack Kit
HP StorageWorks MSL6000 Tape Library
MSL6030, 1 drive, 30 slots, Ultrium 460, RM MSL6030, 2 drive, 30 slots, Ultrium 460, RM MSL6030, 1 drive, 30 slots, Ultrium 460, RM with embedded FC router MSL6030, 2 drive, 30 slots, Ultrium 460, RM with embedded FC router MSL6030, 1 drive, 30 slots, Ultrium 460, TT MSL6030, 2 drive, 30 slots, Ultrium 460, TT MSL6060, 2 drive, 60 slot, Ultrium 460, RM MSL6060, 2 drive, 60 slot, Ultrium 460, RM with embedded FC router MSL6060, 2 drive, 60 slot, Ultrium 460, TT
NOTE:
Please reference the MSL6000 Tape Library QuickSpecs at
http://www.hp.com/go/automation
solution; reference current compatibility information at
HP StorageWorks MSL5026S2 Tape Library
MSL5026S2, 1 drive, 26 slots, SDLT 320, RM MSL5026S2, 2 drive, 26 slots, SDLT 320, RM MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router MSL5026S2, 1 drive, 26 slots, SDLT 320, TT MSL5026S2, 2 drive, 26 slots, SDLT 320, TT
NOTE:
Please reference the MSL5026S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation
solution; reference current compatibility information at
HP StorageWorks MSL5052S2 Tape Library
MSL5052S2, 2 drive, 52 slots, SDLT 320, RM MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router MSL5052S2, 2 drive, 52 slots, SDLT 320, TT
NOTE:
Please reference the MSL5052S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation
for additional information needed to create a complete
http://www.hp.com/go/ebs
for additional information needed to create a complete
http://www.hp.com/go/ebs
for additional information needed to create a complete
240560-B21 240559-B21 364565-B21 240562-B21
230743-B21 293121-B21
365044-B21
245249-B21 266076-B21
330731-B22 330731-B23 330731-B24 330731-B25 330788-B21 330788-B22 331196-B21 331196-B22 331195-B21
293472-B22 293472-B23 293472-B24 293472-B25 293473-B21 293473-B22
293474-B21 293474-B24 293476-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 25
QuickSpecs
Options
HP ProLiant BL30p Server Blade
solution; reference current compatibility information at
HP StorageWorks MSL5030 Tape Library
MSL5030, 1 drive, 30 slots, Ultrium 230, RM MSL5030, 2 drive, 30 slots, Ultrium 230, RM MSL5030, 1 drive, 30 slots, Ultrium 230, RM with embedded FC router MSL5030, 2 drive, 30 slots, Ultrium 230, RM with embedded FC router MSL5030, 1 drive, 30 slots, Ultrium 230, TT MSL5030, 2 drive, 30 slots, Ultrium 230, TT
NOTE:
Please reference the MSL5030 Tape Library QuickSpecs at
http://www.hp.com/go/automation
solution; reference current compatibility information at
HP StorageWorks MSL5060 Tape Library
MSL5060, 2 drive, 60 slots, Ultrium 230, RM MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router MSL5060, 2 drive, 60 slots, Ultrium 230, TT
NOTE:
Please reference the MSL5060 Tape Library QuickSpecs at
http://www.hp.com/go/automation
solution; reference current compatibility information at
HP StorageWorks ESL9000 Series Tape Libraries
ESL9595 Extended Tape Library, 0 drive, 400 slots (card cage, Interface Mgr card, Command View license)
ESL9322 Extended Tape Library, 0 drive, 222 slots (card cage, Interface Mgr card, Command View license)
ESL9000 Ultrium 460 drive kit ESL9000 Ultrium 230 drive kit ESL9000 SDLT 320 drive kit
NOTE:
Please reference the ESL9000 Series Tape Libraries QuickSpecs at
http://www.hp.com/go/automation
solution; reference current compatibility information at
for additional information needed to create a complete
for additional information needed to create a complete
for additional information needed to create a complete
http:/www.hp.com/go/ebs
301897-B22 301897-B23 301897-B24 301897-B25 301898-B21 301898-B22
http://www.hp.com/go/ebs
301899-B22 301899-B23 301900-B21
http://www.hp.com/go/ebs
343378-B21
343377-B21
330834-B21 301930-B21 293414-B21
http://www.hp.com/go/ebs
DA - 11958 North America — Version 6 — September 24, 2004
Page 26
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Magneto-Optical Jukeboxes
HP StorageWorks Modular Smart Array 1000
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
300mx, 2 drive, 32 slot jukebox 600mx, 4 drive, 64 slot jukebox
700mx, 2 drive, 76 slot jukebox
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, up to 128 slots 1200mx, 6 drive, up to 128 slots 2200mx, 4 drive, up to 238 slots 2200mx, 6 drive, up to 238 slots 2200mx, 10 drive, up to 238 slots
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical
HP StorageWorks Modular Smart Array 1000 Modular Smart Array 1000 Controller Modular Smart Array Fibre Channel I/O Module Modular Smart Array hub 2/3 HP StorageWorks Modular Smart Array 1000
NOTE:
Please see the StorageWorks Modular Smart Array 1000 QuickSpecs for additional options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
for additional information needed to create a complete solution
for additional information needed to create a complete solution
C1150M C1160M
C1170M
C1104M C1105M C1111M C1107M C1110M
201723-B22 218231-B22 218960-B21 286763-B21 201723-B22
DA - 11958 North America — Version 6 — September 24, 2004
Page 27
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Cluster Options
ProLiant Cluster HA/F200 for Modular Smart Array 1000
NOTE:
For additional information regarding the ProLiant Cluster for HA/F100, HA/F200 for Modular Smart Array 1000 please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11035_na/11035_na.html
ProLiant Cluster HA/F500 Enhanced Kit for Enterprise Virtual Array ProLiant Cluster HA/F500 Basic Kit for Enterprise Virtual Array
NOTE:
For additional information regarding the HP ProLiant Cluster for ProLiant Cluster HA/F500 for Enterprise Virtual Array please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11055_na/11055_na.html
NOTE:
For additional information regarding the HP ProLiant Cluster for HA/F500 please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/10232_na/10232_na.html
HP Serviceguard for Linux ProLiant Cluster A.11.14 for Red Hat EL 2.1 (2 node license cluster kit)
NOTE:
Kit includes 2 licenses, documentation and an Ethernet crossover cable.
HP Serviceguard for Linux ProLiant Cluster (2 node license cluster kit) A.11.15
NOTE:
Kit includes 2 licenses, documentation and an Ethernet crossover cable.
HP Serviceguard for Linux (single license version for ordering flexibility and to ease ordering for larger cluster for Red Hat AS 2.1) A.11.14
NOTE:
Kit includes single license version and documentation.
HP Serviceguard for Linux (single license version for ordering flexibility and to ease ordering for larger cluster) A.11.15
NOTE:
Kit includes single license version and documentation.
NOTE:
For additional information regarding the HP Serviceguard for Linux License, please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
252409-B24
254623-B24 313047-B23
305199-B22
305199-B24
307754-B22
307754-B24
USB Options
USB 1.44-MB External Diskette Drive (Carbonite) USB Optical Scroll Mouse (Carbonite) USB Easy Access Keyboard (Carbonite/Silver)
DC141B DD441B
DC168B-ABA
DA - 11958 North America — Version 6 — September 24, 2004
Page 28
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Rack 10000 Series
(Graphite Metallic)
HP S10614 (14U) Rack Cabinet - Shock Pallet HP Rack 10647 (47U) Cabinet - Pallet HP Rack 10647 (47U) Cabinet - Crated HP Rack 10642 (42U) Cabinet - Pallet HP Rack 10642 (42U) Cabinet - Shock Pallet HP Rack 10642 (42U) Cabinet - Crated HP Rack 10636 (36U) Cabinet - Pallet HP Rack 10636 (36U) Cabinet - Shock Pallet HP Rack 10636 (36U) Cabinet - Crate HP Rack 10622 (22U) Cabinet - Pallet HP Rack 10622 (22U) Cabinet - Shock Pallet HP Rack 10622 (22U) Cabinet - Crated
NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE:
Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
NOTE:
For additional information regarding Rack Cabinets, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html
292302-B22 245160-B21 245160-B23 245161-B21 245161-B22 245161-B23 245162-B21 245162-B22 245162-B23 245163-B21 245163-B22 245163-B23
Rack Options for HP Rack 10000 Series
HP Rack Plinth Kit (Carbon) HP Rack Light Kit (Neon) 42U Side Panel – Graphite Metallic 36U Side Panel – Graphite Metallic 47U Side Panel – Graphite Metallic
NOTE: For additional information regarding Rack Options, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html
Server Console Switch 1 x 4 port (100-230 VAC) IP Console Switch Box, 1 x 1 x 16 IP Console Switch Box, 3 x 1 x 16 CPU to Server Console Cable, 12’ CPU to Server Console Cable, 3’ CPU to Server Console Cable, 7’ IP CAT5 Cable 3’, 4 pack IP CAT5 Cable 6’, 8 pack IP CAT5 Cable 12’, 8 pack IP CAT5 Cable 20’, 4 pack IP CAT5 Cable 40’, 1 pack TFT5600 Rack Keyboard Monitor TFT7210R Rack Mounted 17" Monitor
NOTE:
For a complete list of Monitors please view the following URL:
http://h18004.www1.hp.com/products/monitors/
1U Rack Keyboard & Drawer (Carbon)
NOTE:
For additional information regarding Rack Options, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html
251960-B21 361589-B21 246099-B21 246102-B21 255486-B21
.
400336-001 262585-B21 262586-B21 110936-B21 110936-B24 110936-B25 263474-B21 263474-B22 263474-B23 263474-B24 263474-B25
221546-001 348373-B21
257054-001
.
DA - 11958 North America — Version 6 — September 24, 2004
Page 29
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Service and Support Offerings
Services)
(HP Care Pack
NOTE:
The HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
Installation & Start-up Services
ProLiant BL p-Class Blade Server Hardware Installation ProLiant BL p-Class Blade Server Hardware Installation, Electronic ProLiant BL p-Class Enclosure and Server Blade Hardware Installation ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic Provides for the Installation and Start-up of Compaq's Rapid Deployment Pack on a Customer
supplied server designated as a Deployment Server. Includes the deployment of a single server. This new server will be deployed using either one of the pre-configured scripts or an image. In addition, the service will provide for the capture and storage of the configuration of the newly deployed server and orientation on product usage. To be delivered during standard office ours, standard office days.
Provides for the Installation and Start-up of Compaq's Rapid Deployment Pack on a Customer supplied server designated as a Deployment Server. Includes the deployment of a single server. This new server will be deployed using either one of the pre-configured scripts or an image. In addition, the service will provide for the capture and storage of the configuration of the newly deployed server and orientation on product usage. To be delivered during standard office ours, standard office days. Electronic.
NOTE:
For more information, customer/resellers can contact
http://www.hp.com/hps/
.
UA203A
UA203E
UA204A
UA204E
UA205A
UA205E
UA206A
UA206E
UA219A
UA219E U4971A
U4971E
U5683A
U5683E
DA - 11958 North America — Version 6 — September 24, 2004
Page 30
QuickSpecs
HP ProLiant BL30p Server Blade

Memory

ProLiant BL30p Server Blade (all models) Standard Memory
1024-MB PC2100 MHz Registered DDR SDRAM DIMM installed (1 x 1-GB SDRAM DIMM)
Standard Memory Replaced with Optional Memory
Up to 4096-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional SDRAM DDR DIMM memory expansion kits.
Memory
Standard Optional Optional Maximum
1024 MB 1024 MB 1024 MB 2048 MB 1024 MB 1024 MB 4096 MB 2048 MB 2048 MB
1 2
512 KB 512 KB
Following are memory options available from HP:
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB) 1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1 GB) 1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
Slot
300682-B21 287497-B21 257974-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 31
QuickSpecs

Technical Specifications

HP ProLiant BL30p Server Blade
ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components
Operating and Performance Specifications for ProLiant BLp-Class RJ-45 Patch Panel 2 with Fiber Channel pass through
Dimensions
Input Specifications
Individual Server Blade Bay Ratings
Temperature Range
Relative Humidity (non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Dimensions
Capability Network Transfer Rate
Fiber Channel SAN Connector
Cable Support
EMI
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Height Width Depth Rated input voltage Rated input current Rated input Power Rated input voltage Rated input current Rated input Power Operating Non-Operating Operating Non-Operating Operating Non-Operating
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Velio VC1070 re-timer Network Fiber Channel SAN 10 Base-TX
100 Base-TX 1000 Base-TX Fiber Channel FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC 125 A at -48 VDC 6000 W
-43 VDC to -53 VDC
14.6 A at -48 VDC 700 W 50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps Auto-rate negotiate between 2G and 1G 32 RJ-45 in the back. 16 Pluggable SFP optical cages in the front Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft/100 m Category 5E (4 pair); up to 328 ft (100 m) SFP optical cable
Nominal -48 VDC
Nominal -48 VDC
DA - 11958 North America — Version 6 — September 24, 2004
Page 32
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and Performance Specifications for ProLiant BL p-Class RJ-45 Patch Panel
Dimensions
Capability Network Transfer Rate
Connector Cable Support
Power Requirements Temperature Range
Relative Humidity (non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Network 10 Base-TX
100 Base-TX 1000 Base-TX 200 mA at + 5V DC; 500 mA at -48V Operating Non-operating Operating Non-operating Operating Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps 16 RJ-45 in the back Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft (100 m) Category 5E (4 pair); up to 328 ft (100 m)
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and Performance Specifications for ProLiant BL p-Class GbE Interconnect Switch
Dimensions
Weight Performance
Forwarding Mode MAC Addresses
Forwarding Table Age Time
Memory Compliance
Height Width Depth
11.5 lb/5.2 kg per interconnect switch
9.6 Gbps external port bandwidth per server blade enclosure (full duplex) Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-
byte packets) Non-blocking, full-wire speed for all connections Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 8,191 per interconnect switch; MAC address based filtering and MAC address packet
priority configuring Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac,
802.3ad (Static), and 802.1Q SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet
MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps
IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and ZModem,
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
DA - 11958 North America — Version 6 — September 24, 2004
Page 33
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Network Transfer Rate
Connector
EMI
Safety
Power Requirements
Temperature R range
Relative Humidity (non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half-duplex) 1000 Base-TX (full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE
-48VDC: 1050 mA, 50 W maximum (per interconnect switch)
Operating Non-operating Operating Non-operating Operating Non-operating
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps 2000 Mbps 2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 34
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and Performance Specifications for ProLiant BL p-Class GbE2 Interconnect Switch
Dimensions
Weight Performance
Forwarding Mode MAC Addresses Forwarding Table
Age Time Memory Compliance
Network Transfer Rate
Connector
EMI
Safety
Power Requirements
Temperature Range
Relative Humidity (non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Height Width Depth
12.0 lb/5.4 kg per interconnect switch 24 Gbps External port bandwidth per server blade enclosure (full duplex) Forwarding rate 1.5 million pps per gigabit port (64-byte packets) Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 2,048 per interconnect switch Maximum age: 1 to 65535 seconds; default: 300 seconds
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad
(Static), and 802.1Q SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB
(RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC
2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC
1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps
RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem
10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half-duplex) 1000 Base-TX (full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE 48VDC: 2040 mA, 98 W maximum (per interconnect switch without GbE2 Storage
Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with GbE2 Storage Connectivity Kit)
Operating Non-operating Operating Non-operating Operating Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps 2000 Mbps 2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 35
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and Performance Specifications for ProLiant BL p-Class Power Enclosures
Dimensions
Weights
Input Requirements
Output Voltage Specifications
Ambient Temperature Range (See
Relative humidity, non-condensing
(See
Wet Bulb Temperature
NOTE:
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
NOTE
)
NOTE
)
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
Height Width Depth No Hot-Plug
Power Supplies All Hot-Plug
Power Supplies Rated input voltage
Rated input frequency Rated input current
per side Rated input power
per side Power cord Rated output voltage Rated output current Rated output power Nominal power Operating
Shipping
Operating Non-operating Operating
Non-operating
Single-Phase Model
5.25 in (13.34 cm) 5.25 in (13.34 cm)
27.15 in (68.96 cm) 27.15 in (68.96 cm)
17.60 in (44.7 cm) 17.60 in (44.7 cm)
47.5 lb (21.55 kg) 47.5 lb (21.55 kg)
99.5 lb (45.13 kg)
200 VAC to 240 VAC
50 Hz to 60 Hz 50 Hz to 60 Hz 24A
5760 W 9976 W
1 NEMA L6-30P per side
-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC 99A 4298 W 8310 W 4158 W at 208 VAC 7202 W at 208 VAC 50° to 95° F
(10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80% 20% to 80% 5% to 95% 5% to 95%
82.4° F (28° C) 82.4° F (28° C)
101.7° F (38.7° C) 101.7° F (38.7° C)
3-Phase Model
125.5 lb (56.93 kg)
200 VAC to 240 VAC line to line
24A per phase
1 NEMA L15-30 per side
170A
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 36
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and Performance Specifications for ProLiant BL p-Class Power Distribution Devices
Power Enclosures or facility DC feeds Supported
(3U each)
Server blade enclosures supported
(6U each)
Total rack height of supported enclosures
Dimensions
Height Width Depth
Weight Rated Operating
Voltage Max Total Power
Supported Total Max Input Current
At Minimum Voltage
Total Max Input Current At Nominal Voltage
Max Current Per Power Feed
Max Local Ambient Temperature
NOTE:
All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.
Power Bus Box
1
1 up to 3 up to 5
9U
5.1 in (12.95 cm)
3.6 in (9.14 cm) each
3.25 in (8.26 cm)
3.62 lb (1.64 kg)
-43.2 VDC to -54 VDC -43.2 VDC to -54 VDC -43.2 VDC to -54 VDC
3000 W 9000 W
69.44 A at -43.2VDC
62.5 A at -48VDC
70A 70A
149° F (65° C) 149° F (65° C) 149° F (65° C)
Mini Bus Bar
1 or 2 1 or 2
24U 36U
19.45 in (49.40 cm)
19.74 in (50.14 cm) 19.74 in (50.14 cm)
2.2 in (5.59 cm) 2.2 in (5.59 cm)
13.2 lb (5.9 kg)
208.32 A at -43.2 VDC
187.5 A at -48 VDC 312.5 A at -48 VDC
Scalable Bus Bar
48.57 in (123.37 cm)
26 lb (11.79 kg)
15000 W
347.2 A at -43.2 VDC (equivalent of 175A per feed)
(equivalent of 175A per feed)
210A
DA - 11958 North America — Version 6 — September 24, 2004
Page 37
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and Performance Specifications for Facility DC
Voltage
Current
In-rush current
Input over-current
Max Input Current Slew Rate
Max Rated Power Connections and Cables
NOTE:
*All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds. ** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on
any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert.
Nominal input voltage Operating voltage range Max Input voltage slew rate Redundant feed voltages*
(A & B) Ripple/Noise Overshoot
Voltage transients Max steady state input
current Max steady state current per
feed/total
Power bus boxes Mini bus bars Scalable bus bars
Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS
Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents.
1A/uS
3000W per server blade enclosure HP provided facility DC cable connection kit:
The facility DC connection kit supports the connection of up to four -48VDC, RETURN pairs and ground
The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack.
-48 VDC
-48VDC ± 10% or -43.2 VDC to -52.8 VDC
0.5V/uS *A and B feeds must differ by no more than 5VDC
during steady state operation 480 mV PARD** Must remain within regulation limits on all feeds during
startup or shutdown Must not exceed -60 VDC
62.5A per server blade enclosure installed at -48VDC
70 A/70A 210 A/210A 210 A/350A or equivalent of 175A per feed*
© Copyright 2004 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 11958 North America — Version 6 — September 24, 2004
Page 38
Loading...