ProLiant BL30p -- A new high density, dual-processor capable server blade for the ProLiant BL p-Class
An enhanced, fully backwards-compatible server blade enclosure featuring support for the new BL30p series server blades and all current
and future BL20p series and BL40p series blades
New enclosure with enhanced backplane components features Integrated Light-Out (iLO) management cable consolidation
iLO provides new feature for automatically assigning static IP addresses for blades
New dual power input option kit allows support for two power enclosures on mini bus bars
DA - 11958 North America — Version 6 — September 24, 2004
Page 1
QuickSpecs
HP ProLiant BL30p Server Blade
Overview
At A Glance
Maximum density ProLiant BL30p server blade
Up to two Intel Xeon 3.2-GHz/533-MHz with 2MB L3 cache processors with Hyper-Threading Technology
ServerWorks GC-LE chipset
1024-MB PC2100-MHz Registered ECC DDR memory (1 x 1-GB), expandable to 4-GB, flex memory supports interleaved and noninterleaved memory configurations
Integrated Lights-Out (iLO) Advanced Pack with new static IP bay configuration feature
Two (2) NC7781 PCI-X Gigabit NICs (embedded)
One 10/100T NIC (embedded) dedicated to iLO management
Supports up to two optional small form factor ATA 60-GB hard drives
BIOS-Enhanced RAID for Linux enables both primary and secondary hard drives to be bootable
Dual-Port Fibre Channel Adapter (2-Gb) option for SAN connectivity
BL30p plugs vertically into blade sleeve and sleeve plugs into 6U blade enclosure
Local I/O cable attaches to front of blade and provides two USB ports, one video port, one iLO port and serial port
Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and Common
Procedures guides
Up to 96 BL30p blades fit in 42U rack in non-redundant power configuration; up to 80 BL30p blades fit in 42U in full power redundant
configuration
ProLiant BL p-Class Server Blade Enclosure with Enhanced Backplane Components
Updated to support the new BL30p blade and be fully compatible with all current and future BL20p series and BL40p series blades
Blade iLO signals are physically consolidated to an RJ-45 port on the server blade management module
Option kit available for field upgrade of backplanes to existing, deployed blade enclosures
Each server blade enclosure is 6U and holds up to 16 ProLiant BL30p server blades (BL30p blade sleeve is required for each pair of
BL30p blades installed)
Interconnect options for network signal routing include GbE Interconnect Switches, GbE2 Interconnect Switches with optional Fibre
Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through
ProLiant BL p-Class Power Enclosure
BL p-Class rack-centralized power enclosure holds hot-plug power supplies
Use BL p-Class sizing tool to determine power and cooling requirements based on your desired configuration:
3 phase power enclosure highly recommended for BL30p deployments
BL p-Class power enclosure not needed if using facility -48VDC ± 10% (DC option kit required)
ProLiant BL p-Class Power Distribution
Carries power from the power enclosure(s) to the server blade enclosures
Three power distribution choices:
mini bus bars (support up to 3 blade enclosures)
scalable bus bars (support up to 5 blade enclosures)
power bus box (supports a single blade enclosure)
New dual power input option kit allows support for two power enclosures on mini bus bars
BL p-Class server blades, server blade enclosures, interconnects and power enclosures protected by a limited three year warranty with
optional service uplifts available.
which they are installed.
NOTE:
Power requirements for a ProLiant BL p-Class system: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
NOTE:
All ATA hard drives offered by HP carry a one year warranty regardless of the base system in
DA - 11958 North America — Version 6 — September 24, 2004
DA - 11958 North America — Version 6 — September 24, 2004
Page 3
QuickSpecs
Overview
BL p-Class Server Blade Enclosure with enhanced backplane components
HP ProLiant BL30p Server Blade
+
OR
Patch Panel (shown) or
Patch Panel 2
BL p-Class Interconnects
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch
+
BL p-Class power enclosure(s) and power supplies (three phase recommended)
+
OR
Facility DC
(fiber- or copper-based)
DA - 11958 North America — Version 6 — September 24, 2004
Page 4
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
OROR
Mini bus bars
Scalable bus bars
BL p-Class power distribution
Bus boxes
Configuration Steps
For a complete ProLiant BL30p blade solution, do the following:
Select desired model, configuration and quantity of ProLiant BL30p server blades
1.
PLUS
Determine how many BL30p blade sleeves are required. Each BL30p blade sleeve holds two BL30p server blades and one server blade
2.
enclosure holds up to eight sleeves.
PLUS
3. Determine how many BL p-Class Server Blade Enclosures with enhanced backplanes are required. Each blade enclosure with enhanced
3.
backplanes can hold up to 16 ProLiant BL30p server blades.
NOTE:
ProLiant BL p-Class server blade enclosures with enhanced backplane components are required to support BL30p server blades.
Server blade enclosures with enhanced backplanes can be purchased with licenses for Rapid Deployment Pack:
BL p-Class server blade enclosure with enhanced backplanes with 8 Rapid Deployment Pack licenses (281404-B22)
or
BL p-Class server blade enclosure with enhanced backplanes with Rapid Deployment Pack trial (243564-B22)
PLUS
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects. One interconnect kit is required with each server blade
enclosure:
RJ-45 Patch Panel 2 with Fibre Channel pass through. This is the required patch panel model for Fibre Channel connectivity on BL30p
(306465-B21).
or
DA - 11958 North America — Version 6 — September 24, 2004
Page 5
QuickSpecs
HP ProLiant BL30p Server Blade
Overview
RJ-45 Patch Panel (230766-B21)
or
BL p-Class C-GbE2 Interconnect Kit (with 12 RJ-45 10/100/1000 T/TX/T external ports) (283192-B21) with or without optional ProLiant BL pClass GbE2 Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BL30p Fibre Channel connectivity
when using the GbE2 Interconnect Switch)
or
BL p-Class F-GbE2 Interconnect (with 8 LC 1000 SX and 4 RJ-45 10/100/1000 T/TX/T external ports) (283193-B21) with or without optional
ProLiant BL p-Class GbE2 Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BL30p Fibre Channel
connectivity when using the GbE2 Interconnect Switch)
or
BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T and 8 RJ-45 10/100 T/TX external ports (249655-B21)
or
BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX and 8 RJ-45 10/100 T/TX external ports) (279720-B21)
PLUS
Select BL p-Class power enclosure(s) and power supplies based on configuration.
5.
NOTE:
3 phase power enclosure options are highly recommended for deployments of BL30p server blades.
Use the ProLiant BL p-Class sizing utility to help determine power configuration:
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
3 phase power enclosure with six power supplies (3 phase power enclosure holds six power supplies) (NA/JPN- 230769-001) (INTL 230769-421)
(Power enclosures and supplies can also be purchased separately see options list)
PLUS
Select power distribution option:
6.
Mini bus bars (support up to 3 server blade enclosures) (240559-B21). Note that two mini-bar configurations can be stacked to fill a 42U
rack.
or
Scalable bus bars (support up to 5 server blade enclosures) (240560-B21)
or
Power Bus Box (supports a single server blade enclosure) (240562-B21)
DA - 11958 North America — Version 6 — September 24, 2004
Page 6
QuickSpecs
Overview
ProLiant BL p-Class Server Blade Enclosures with Enhanced Backplanes Installed in 42U Rack
Redundant Power Configuration (left) and Non-Redundant Power Configurations (right)
HP ProLiant BL30p Server Blade
1. Power Enclosure
DA - 11958 North America — Version 6 — September 24, 2004
Page 7
QuickSpecs
Standard Features (Server Blade)
HP ProLiant BL30p Server Blade
Processor
Upgradeability
Cache Memory
One of the following
depending on Model
Chipset
Memory
Network Adapter
Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache
Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache
Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache
For more information regarding the ServerWorks chipset, see the following website:
http://www.serverworks.com/products/overview.html
Standard
Maximum
Flex Memory
Three (3) network adapters total:
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One 10/100T NIC (embedded) dedicated to iLO management
1024-MB (1 x 1-GB) PC2100 DDR SDRAM running at 266MHz; non-interleaved unless a second
DIMM option installed 287497-B21
4-GB
BL30p blade supports memory interleaving when an identical pair of DIMMs is installed
Integrated Manageability
Internal Storage
Integrated Lights-Out (iLO) Management Advanced Pack with new static IP bay configuration feature
Hard Drives
Maximum Internal Storage
None ship standard
120-GB (2 x 60-GB small form factor ATA, 5400 RPM hard drives)
DA - 11958 North America — Version 6 — September 24, 2004
Page 8
QuickSpecs
Standard Features (Server Blade)
HP ProLiant BL30p Server Blade
Fiber Channel on the
ProLiant BL30p
The following items are needed to connect the ProLiant BL30p to a SAN via Fibre Channel:
1. ProLiant BL30p blade with Dual-Port Fibre Channel Adapter (option) installed
The Dual-Port Fibre Channel Adapter option 354054-B21 is compatible with the ProLiant BL30p blade (not
compatible with ProLiant BL20p series blades)
Two ports on each configured blade provide redundant Fibre Channel connections
Supports up to 2 Gb/s and backward compatible with existing 1 Gb/s Fibre Channel equipment
Based on the QLogic ISP2312 chipset
Kit includes two small form factor pluggable transceivers with LC connectors for installation into the
interconnect option kit (see 2A and 2B below)
Enables pass through of both Ethernet and Fibre Channel signals
Ethernet signals exit the rear of the RJ-45 Patch Panel 2 interconnects
Fibre Channel signals exit the front of the RJ-5 Patch Panel 2 interconnects
8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel
2 interconnect (16 Fibre Channel SPF transceiver cages per server blade enclosure)
SPF transceivers are included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
OR
2B. C-GbE2 or F-GbE2 Interconnect Kit plus the GbE2 Storage Connectivity Kit (option)
Enables Ethernet signal consolidation and pass through of Fibre Channel signals
Both Ethernet and Fibre Channel signals exit the rear of the GbE2 Interconnect Switch (with the GbE2 Storage
Connectivity Kit option)
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each GbE2
Interconnect Switch (16 Fibre Channel SPF transceiver cages per server blade enclosure)
SPF transceivers included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
Local I/O Cable
AND
3. Compatible SAN
Optimized for StorageWorks arrays:
Connects to the front of BL30p server blade for local management and aid in first server blade configuration
Two (2) USB ports, one (1) video port, one (1) iLO port and one (1) serial port
Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components (281404-B22
and 243564-B22)
NOTE:
Tested USB devices (keyboard, mouse, floppy) are listed in options section below.
DA - 11958 North America — Version 6 — September 24, 2004
Page 9
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class Server Blade Enclosure and Interconnects
ProLiant BL p-Class
Server Blade Enclosure
6U (10.5-inch), 19-inch wide
Holds up to:
Eight (8) ProLiant BL20p series server blades
Sixteen (16) ProLiant BL30p series server blades (BL30p blade sleeves required)
Two (2) ProLiant BL40p series server blades
A combination of the above
NOTE:
ProLiant BL p-Class server blade enclosures with enhanced backplane components are required to support
BL30p server blades.
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a
field upgrade of a blade enclosure to support BL30p series blades and provide a single, physical iLO port for the
enclosure.
Two (2) outside bays for interconnects (Patch Panel, Patch Panel 2, GbE Interconnect Switch, or GbE2 Interconnect
Switch)
Server blade management module on the rear of the server blade enclosure is hot-plug, has a centralized 10/100T
iLO port for all installed blades, reports events of all installed blades and provides asset and inventory information via
SNMP.
3 phase power highly recommended for BL30p deployments.
Redundant 200V - 240V AC, 30 amp single-phase for NA and International
Redundant -48VDC ± 10%
DA - 11958 North America — Version 6 — September 24, 2004
Page 10
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class
Interconnect Switch
Option
(A pair of switches per kit)
(Each server blade enclosure
requires a pair of
interconnects - patch panels
or interconnect switches)
Interconnect Switch interconnects consolidate the Ethernet signals from the server blades to a smaller set of
external copper-based or fiber-based uplink ports for connection to the network infrastructure. Like the Patch Panel
interconnects, an option is also available to pass through individual BL20p G2 and BL30p Fibre Channel signals.
The interconnect switches provide up to a 32-to-1 server network cable reduction per server enclosure depending
on the mix of BL20p series, BL30p series, and BL40p series blades. Each interconnect switch pair reduces up to
sixteen internal server network (NIC) ports to one to six external ports (four on a modular rear mounting interconnect
and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) provide NIC consolidation to 1000 Mbps (Gigabit Ethernet),
advanced network feature support including layer 3-7 switching, Fibre Channel pass-through (for BL20p series and
BL30p series blades), and 10 Gigabit Ethernet bandwidth connectivity to the network. Expandability of both layer 3-7
switching and 10 Gigabit Ethernet is planned with future GbE2 Interconnect Switch upgrade options available
through Nortel Networks.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX
Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports
per server blade enclosure.
The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2
Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade
enclosure.
The optional ProLiant BL p-Class GbE2 Storage Connectivity Kit (321745 -B21) is required for Fibre Channel
pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) provide NIC consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX
Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per
server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT
Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external
ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port
Redundant crosslink ports connecting the two interconnect switches
Redundant power inputs and on-board redundant fans
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Power ON, management, and per port status and speed LED indicators
Reset/power momentary push-button switch
HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD
Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100
Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX
Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per
server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT
Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external
ports per server blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities:
Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user
accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible
multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control,
human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, autonegotiation and auto-sensing of speed and duplex mode, and more.
DA - 11958 North America — Version 6 — September 24, 2004
Page 11
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
(Each server blade enclosure
requires a pair of
interconnects - patch panels
or interconnect switches)
ProLiant BL p-Class RJ-45
Patch Panel 2
Channel pass through)
(A pair of patch panels
provided per kit)
(Each server blade enclosure
requires a pair of
interconnects - patch panels
or interconnect switches)
NOTE:
Either Patch Panel 2 or
a GbE2 Interconnect Kit is
required for SAN connectivity
with BL20p series and BL30p
series blades.
(with Fibre
The GbE2 Storage Connectivity Kit (option) is required for Fibre Channel signal pass-through when using a GbE2
Interconnect Switch Kit. Both Ethernet cable consolidation and Fibre Channel connectivity is possible using a single
interconnect option. Order one GbE2 Storage Connectivity Kit per server blade enclosure for Fibre Channel pass
through of BL20p and BL30p series blades.
The GbE2 Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver
cages for the pluggable small form factor transceivers that come with each BL30p Dual-Port Fibre Channel Adapter
(option) and each BL20p Dual Port Fibre Channel Adapter. The GbE2 Storage Connectivity Kit supports up to eight
BL20p series, up to sixteen BL30p series blades or combinations thereof.
6U (10.5-inch), plugs into BL p-Class 6U server blade enclosures.
Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections.
Supports Gigabit Ethernet network adapters.
16 RJ-45 connectors on the back of each RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure).
The benefits to the RJ-45 Patch Panel are that it:
- Allows the customer to connect signals to their own LAN infrastructure components.
- Provides very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
6U (10.5-inch), plugs into BL p-Class 6U server blade enclosures.
Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45 connections.
Supports Gigabit Ethernet network adapters.
16 RJ-45 connectors on the back of each RJ-45 Patch Panel 2 (32 RJ-45 connections per server blade enclosure).
Passes through Fibre Channel signals, from all installed BL20p and BL30p series server blades, individually out
through small form factor pluggable (SPF) transceiver cages.
Supports 2 Gb/s Fibre Channel signals and backward compatible with existing 1 Gb/s Fibre Channel equipment.
8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2 (16 Fibre
Channel SPF transceiver cages per server blade enclosure).
The benefits to the RJ-45 Patch Panel 2 are that it:
- Allows the customer to connect signals to their own LAN and SAN infrastructure components.
- Provides a very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
- Electrically isolates the Ethernet and Fibre Channel signals from each other.
ProLiant BL p-Class Fibre
Channel pass through
Fibre Channel signals travel from a ProLiant BL20p series and/or BL30p series blades through the server blade
enclosure backplane. Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 or GbE2 Interconnect
Switch (with GbE2 Storage Connectivity Kit) in the interconnect bays. To provide redundancy each server blade has
two Fibre Channel signals; one Fibre Channel signal terminates through the right interconnect, the other Fibre
Channel signal terminates through the left interconnect.
Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45 Patch Panel
2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server blade enclosure). The SPF
cages are used for insertion of SPF transceivers included with the BL20p G2 Dual-port Fibre Channel Mezzanine
Card and the BL30p Dual-Port Fibre Channel Adapter.
DA - 11958 North America — Version 6 — September 24, 2004
Page 12
QuickSpecs
HP ProLiant BL30p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
DA - 11958 North America — Version 6 — September 24, 2004
Page 13
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL30p Server Blade
ProLiant BL p-Class
Power System and
Rack Information
ProLiant BL p-Class
Power Enclosure
BL p-Class Power
Distribution
Scalable Bus Bar
Mini Bus Bar
Power Bus Box
Required Power Source
NOTE:
To determine power configuration, please refer to the ProLiant BL p-Class Overview and Planning Whitepaper
and sizing utility at
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), dual input single phase and three
phase models available.
BL p-Class power enclosure provides scalable rack-centralized, hot-plug power without the need for PDUs.
Each 3 phase power enclosure houses six hot-plug power supplies
Each single-phase power enclosure holds four hot-plug power supplies
Please use the sizing utility to determine the power needed for each configuration
3 phase power enclosure options highly recommended for BL30p deployments.
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC,
Facility DC Power Connection kit (240563-B21) is needed.
-48 VDC power (from the power enclosures or facility DC power) is carried from the power enclosures to the
server blade enclosures through bus bars (for multiple enclosures) or power bus boxes (for a single enclosure).
Hinges attach the bus bars to the rack rails and provide easy rear access to the blade enclosures and
interconnects. Power is distributed through independent A- and B-sided bus bars.
Three power distribution solutions are available depending on the size of the intended deployment (see table).
Power Enclosures Supported
NOTE*:
Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.
NOTE:
To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars.
Two 30-Amp redundant power feeds per power enclosure
Connectors:
1.
NA 1-phase L6-30, 250v, 30A 3-wire
NA 3-phase L15-30, 250V, 30A, 4-wire
For cabling information, refer to the website at:
http://www.hp.com/go/servers/
DA - 11958 North America — Version 6 — September 24, 2004
Page 14
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
ProLiant Essentials
Foundation Pack
Software for the ProLiant
BL Server
ProLiant Essentials Rapid
Deployment Pack
HP Systems Insight Manger
Management Agents
Subscriber's Choice
ROMPaq, support software,
and
configuration utilities
Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution
for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant
Integration Module featuring ProLiant server pre-configured events for OS installation,
and optimized software drivers, firmware and management agents. Every RDP CD
includes 10-node trial licenses for evaluation purposes. RDP requires a license for
each server deployed and are available for purchase with blade servers. For more
information, visit
HP Systems Insight Manager (HP SIM) help maximize system uptime and performance
and reduce system maintenance costs by providing proactive notification of problems
before those problems result in unplanned downtime or reduced productivity. HP SIM
is easy to set up to work with the Insight Management Agents, integrated Light-Out
and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust
fault, configuration, and asset management as well as remote administration. With HP
Systems Insight Manager customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins
for storage, client, printer, and power management as well as server rapid
deployment, performance management, and workload management. For more details
on HP Systems Insight Manager visit
The Management Agents form the foundation for HP's Intelligent Manageability
strategy. They provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, and portables, and send alerts to HP
Systems Insight Manager and other enterprise management applications in case of
subsystem or environmental failures. For additional information about the Management
Agents and other management products from HP, please visit the management Web
site at
http://www.hp.com/servers/manage
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email
subscription service that provides software and driver change notifications for
ProLiant products. Sign up at
and customize your profile to receive various new alerts as they become available,
on a weekly or monthly basis.
The latest software, drivers, and firmware fully optimized and tested for your ProLiant
server and options, available in the RDP CD, SmartStart or downloadable from
Software and Drivers download pages, linked from the SmartStart website at
http://www.hp.com/servers/smartstart
http://www.hp.com/servers/rdp
http://www.hp.com/go/hpsim
.
http://www.hp.com/go/subscriberschoice
.
.
.
Optional ProLiant
Essentials Value Packs
Survey Utility and diagnostics
utilities
NOTE:
For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific
business problems and needs:
Workload Management Pack - provides easier management of complex environments, improving overall
server utilization and enabling customers for the first time to confidently deploy multiple applications on a
single multiprocessor ProLiant Server.
Performance Management Pack - identifies and explains hardware performance bottlenecks on ProLiant
servers and attached options enabling users to better utilize their valuable resources.
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials
more information.
The most advanced configuration analysis, reporting and troubleshooting utilities used
by HP and at your fingertips, available in SmartStart.
or the various ProLiant Essentials Value Pack product QuickSpecs for
DA - 11958 North America — Version 6 — September 24, 2004
Page 15
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
SmartStart
OS Support
Intelligent Manageability
SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and consistent server
configurations. SmartStart 7.00 and later can now deploy the ProLiant BL20P G3 and ProLiant BL40P servers, using
the I/O port with an attached USB CD-ROM device. To obtain a copy of SmartStart for your blade server, redeem the
coupon that is included with your Blade server or order your copy from the SmartStart web site. For more
information, please visit the SmartStart Web site at
SmartStart version supported (minimum): SmartStart 6.20
Microsoft® Windows®
LINUX
NOTE:
For a more complete and up-to-date listing of supported operating systems and versions, please visit our OS
Support Matrices website:
NOTE:
For an up-to-date listing of the latest drivers available for the ProLiant BL p-Class, please visit the support
Static IP bay configuration -- new feature for ProLiant BL p-Class blades
Virtual Text and Graphical Remote Console
Virtual CD-ROM and Virtual Floppy
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
http://www.hp.com/go/ossupport
http://www.hp.com/servers/smartstart
.
NOTE:
For more information on iLO Advanced visit the website:
Automatic Server Recovery-2 (ASR-2)
Redundant ROM
Remote Flash ROM
ROM Based Setup Utility (RBSU)
Advanced Configuration and Power Interface Specification Ready (ACPI)
Server and Interconnect Switch Health Logs
Redundant Power Supply Utility
Pre-Failure Warranty (covers processors, as well as hard drives and memory)
Interconnect Switch Management System and Utilities (Interconnect Switch option)
Integrated Management Log (IML)
Off-Line Backup Processor capability
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Network adapter teaming set-up utility
http://www.hp.com/servers/ilo/
DA - 11958 North America — Version 6 — September 24, 2004
Page 16
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
ProLiant BL p-Class
Availability Features
Power redundancy:
hot-plug power supplies
redundant AC feeds (requires two power enclosures when using blade enclosures with enhanced
backplane components)
interconnects options and server blade management module share power from both A- and B- side
power buses
Dual-Port Fibre Channel Mezzanine Card for redundant SAN connections
Redundant ROM on each server blade
ECC Memory
Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing)
Interconnect Switch availability features:
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Two network connections per BL30p server blade routed to independent interconnect switches
Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports per each
interconnect switch
Redundant front panel ports per each interconnect switch for diagnostics, management, and additional
uplinks
Redundant serial ports
Compatibility with PVST+ (GbE2 switch) and 802.1D Spanning tree protocol support for loop-free path
redundancy
Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and failover
Redundant configuration files and operating system firmware images in memory (GbE2 switch)
Redundant fans per each interconnect switch
Redundant power to each interconnect switch
Support for ProLiant network adapter teaming
Redundant configurable community strings and SNMP trap manager hosts
Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
Security
Minimum Rack
Requirements
Power-on password
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP
secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and
IP address restriction
NOTE*:
GbE2 Interconnect Switch only
Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
Compatible with 19-inch Standard EIA rail sets
EIA rail-to-rail depth is 29 - 30"
Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear RETMA rail
to rear door, inclusive in the 36-inch overall depth)
Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration with
patch panel)
Must be capable of supporting 1600 lb (for full rack configuration)
Perforated front and rear doors to accommodate front-to-back cooling
Must have 65% open perforation on server blade enclosure doors to support airflow requirements
Optimized for use with the HP 10000 Series racks
NOTE:
If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required.
DA - 11958 North America — Version 6 — September 24, 2004
Page 17
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
Rack Airflow
Requirements
Service and Support
HP 10000 series racks provide enhanced airflow for maximum cooling, allowing racks to be fully loaded with
servers and server blades using the latest server technologies.
CAUTION:
to prevent damage to the equipment:
CAUTION:
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal
damage.
NOTE:
server, or to the server documentation located in the Support section on the ProLiant BL30p
website:
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives,
memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and
service providers. In addition 90-day's getting started software telephone support may be covered under the
warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack
services.
NOTE:
NOTE:
site support.
If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830
square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow
(equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum
of 2.75 inches (7 cm).
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement
For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the
http://www.hp.com/servers/bl30p
Sever Blade Limited Warranty includes 3 year Parts, 1 year Labor, 1-year on-site support.
Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-
.
Care Pack services provide a range of life cycle support options that let you choose the service levels that meet
your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call
window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWarebased IT solutions helping to deliver high level of application availability. Response times range from 30 mins
for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade
enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and
power distribution.
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or
visit our worldwide Web site on the internet at:
NOTE:
For more complete information on HP Services offerings, customers and resellers, please visit us at:
http://www.hp.com/hps
NOTE:
Additional information regarding worldwide limited warranty and technical support is available at:
DA - 11958 North America — Version 6 — September 24, 2004
Page 18
QuickSpecs
Models
HP ProLiant BL30p Server Blade
ProLiant BL30p X3.2-2MB,
1GB (2P)
360329-B21
ProLiant BL30p X3.2-1MB,
1GB (2P)
368271-B21
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
Optical Drive
I/O cable
Form Factor
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
Optical Drive
Form Factor
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported)
2-MB Level 3 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB); 2-way interleaved when an identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives)
None
Included
Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with
enhanced backplane components.
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported)
1-MB Level 3 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB); 2-way interleaved when an identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives)
None
Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with
enhanced backplane components.
ProLiant BL30p
X3.06/533MHz-512KB, 1GB
(2P)
354566-B21
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
Optical Drive
Form Factor
Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported)
512-KB Level 2 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266MHz (1
x 1-GB), 2-way interleaved when an identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
None
Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with
enhanced backplane components.
DA - 11958 North America — Version 6 — September 24, 2004
Page 19
QuickSpecs
Models
HP ProLiant BL30p Server Blade
ProLiant BL30p
X3.06/533MHz-512KB, 1GB
(1P)
354050-B21
ProLiant 3.2-GHz BL30p
Server Blade Multi-Pack
368272-B21
NOTE:
Multi-pack contains 8
BL30p server blades, 4
BL30p blade sleeves and 8
licenses for Rapid
Deployment Pack.
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
Optical Drive
Form Factor
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
One (1) Intel Xeon 3.06-GHz standard (up to 2 supported)
512-KB Level 2 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when an identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives)
None
Plugs vertically into BL30p blade sleeve. Blade sleeve supports 1 or 2 BL30p blades.
Blade sleeve plugs vertically into ProLiant BL p-Class Server Blade Enclosure with
enhanced backplane components.
Each blade is configured with Two (2) Intel Xeon 3.2-GHz standard (up to 2
supported)
2-MB Level 3 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
ProLiant 3.06-GHz BL30p
Server Blade Multi-Pack
354051-B21
NOTE:
Multi-pack contains 8
BL30p server blades, 4
BL30p blade sleeves and 8
licenses for Rapid
Deployment Pack.
Processor(s)
Cache Memory
Memory
Network Adapter
Hard Drives
Internal Storage
Each blade is configured with Two (2) Intel Xeon 3.06-GHz standard (up to 2
supported)
512-KB Level 2 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running at 266-MHz
(1 x 1-GB), 2-way interleaved when identical pair installed
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
None ship standard
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
DA - 11958 North America — Version 6 — September 24, 2004
Page 20
QuickSpecs
HP ProLiant BL30p Server Blade
Configuration Information - Factory Integrated Models
NOTE:
HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
Step 1: Base Server Blade Configuration
Model
Step 2: Choose Required Options (only one of the following from each list unless otherwise
noted)
Processor
HP ProLiant BL30p Configurable Model
Configurable Model ships with:
- Two embedded NC7781 PCI-X Gigabit NICs plus one 10/100T NIC for iLO
- Integrated Lights-Out (iLO) Management with Advanced Pack features
For single processor configuration choose:
Xeon 3.06GHz/533-512 FIO Base
For dual-processor configurations choose two each of:
Dual-processor configurations must have a matching pair of CPUs. Mixed clock speeds
are not supported.
367243-405
354053-L21
354053-L21
368273-B21
364306-B21
Memory
NOTE:
Two-way interleaving memory is enabled when an identical pair of DIMMs is installed.
For 1GB Total Memory choose A or B:
A) 2 x 512 MB PC2100 DDR SDRAM DIMMs
B) 1 x 1GB PC2100 DDR SDRAM DIMM
For 2GB Total Memory both A and B are required:
A) 1 x 1GB PC2100 DDR SDRAM DIMM
B) 1 x 1GB PC2100 DDR SDRAM DIMM
For 4GB Total Memory:
2 x 2048MB PC2100 DDR SDRAM DIMM 2x2048
Step 3: Choose Additional Options for Factory Integration
Hard Drive
Fibre Channel Option
60GB Small Form Factor ATA Hard Drive, 5400 rpm
BL30p Dual Port Fibre Channel Adapter
NOTE:
For additional options, including BL30p blade sleeve, server blade enclosure with
enhanced backplanes, interconnect options and power subsystem options, please refer to the
"Options" section below.
300679-B21
287497-L21
287497-L21
287497-B21
300682-B21
354052-B21
354054-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 21
QuickSpecs
HP ProLiant BL30p Server Blade
Options
NOTE:
Some options may not be factory integratable. Please contact your local sales representative for additional information.
Unique Options
ATA Hard Drive Kit for ProLiant BL30p, 2.5" parallel ATA drive, 60GB, 5400 rpm (option)
ProLiant BL30p Blade Sleeve Kit (option)
NOTE:
Each blade sleeve supports one or two BL30p server blades.
354052-B21
354101-B21
ProLiant BL30p Dual-Port
Fibre Channel Adapter
ProLiant Essentials Value
Pack Software
Dual-Port Fibre Channel Adapter (2-Gb) Kit (option) for ProLiant BL30p
NOTE:
When using this card, Patch Panel 2 or a GbE2 Interconnect Switch Kit (with GbE2
Storage Connectivity Kit) must be used to provide pass through of the Fibre Channel signals.
Rapid Deployment Pack, 10 User, V1.x
NOTE:
The above licenses allow 10 servers to be managed and deployed via the Deployment
Server.
NOTE:
Not necessary if you purchase the BL30p Multi-Pack (354051-B21) or server blade
enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE:
Rapid Deployment pack is now available in a Linux Edition for Linux-only environments.
Rapid Deployment Pack, 1 User, V1.x
NOTE:
The above licenses allow 1 server to be managed and deployed via the Deployment
Server.
NOTE:
Not necessary if you purchase the BL30p Multi-Pack (354051-B21) or server blade
enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE:
Rapid Deployment pack is now available in a Linux Edition for Linux-only environments.
Flexible Quantity License Kit
License-Only - for use with a Master License Agreement
ProLiant Essentials Intelligent Networking Pack, Single Server License
NOTE:
For use with a single server. Contains one license with a unique license activation key
and documentation.
For use with multiple servers. This part number can be used to purchase multiple
licenses with a single activation key. The quantity ordered for this part number will be the
quantity of licenses included in the kit in the form of a corresponding activation key. Use the
same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be
delivered with the activation key, and documentation.
For use with signed and implemented Activation Key Agreements only. Purchase of this
part number entitles the customer to deploy additional licenses of the product under the terms of
the existing Activation Key Agreement.
NOTE:
Nothing is delivered in conjunction with the purchase of this part number. Visit
For more information regarding ProLiant Essentials Software, please see the following
URL: http://hp.com/servers/proliantessentials
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to URL
Value Pack product QuickSpecs for more information.
http://hp.com/servers/proliantessentials
.
or the various ProLiant Essentials
354054-B21
269817-B21
267196-B21
302127-B21
302128-B21
372906-B21
372950-B21
372951-B21
303284-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 22
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Processor
Memory
(SDRAM DIMMs)
BL p-Class Server
Blade Enclosures with
enhanced backplane
components
ProLiant BL p-Class server blade enclosures with enhanced backplane components are
required to support BL30p server blades.
ProLiant BL p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane
components and enables a field upgrade of a blade enclosure to support BL30p series blades
and provide a single, physical iLO port for the enclosure.
354053-B21
300682-B21
287497-B21
300679-B21
243564-B22
281404-B22
354100-B21
DA - 11958 North America — Version 6 — September 24, 2004
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class Patch Panel (pair)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two
QuadT2 Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two
QuadSX Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class GbE2 Storage Connectivity Kit (with pair of OctalFC Interconnect Modules
and two Fibre Channel signal conditioning cards)
NOTE:
Required for BL30p Fibre Channel signal pass through when using the GbE2 Interconnect
Switch.
NOTE:
Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit.
ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two
QuadT Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
recommended that a Patch Panel Kit or GbE2 Interconnect Switch Kit option be used if server
NIC speeds to 1000 Mbps are required.
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends
of any individual rack or a series of coupled racks and the front and rear doors must be installed
in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two
DualTSX Interconnect Modules)
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
recommended that a Patch Panel Kit option be used if server NIC speeds to 1000 Mbps are
required.
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends
of any individual rack or a series of coupled racks and the front and rear doors must be installed
in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
306465-B21
230766-B21
283192-B21
283193-B21
321745 -B21
249655-B21
279720-B21
BL p-Class Power Options
NOTE:
Use p-Class sizing tool to help determine power configuration:
Single Phase Redundant Power Enclosure with 4 power supplies
(Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order
additional power supplies with this option kit)
3 Phase Redundant Power Enclosure with 6 power supplies
(3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order additional
power supplies with this option kit)
Single Phase Power Enclosure (empty)
(Holds up to 4 power supplies; power supplies are not included in this kit)
3 Phase Power Enclosure (empty)
(Holds up to 6 power supplies; power supplies are not included in this kit)
Single Power Supply
Facility DC Power Connection
DA - 11958 North America — Version 6 — September 24, 2004
239162-001
230769-001
231710-001
231709-001
239161-B21
240563-B21
Page 24
QuickSpecs
Options
HP ProLiant BL30p Server Blade
ProLiant BL p-Class
Power Distribution
ProLiant BL p-Class Other
Options
Tape Libraries
Scalable Bus Bar
Mini Bus Bar
Dual Power Input Kit for Mini Bus Bar
Power Bus Box
Diagnostic Station
ProLiant BL p-Class Server Enclosure Shipping Bracket Option Kit
NOTE:
Used to secure one server blade enclosure in a rack when moving.
ProLiant BL p-Class Power Enclosure Shipping Bracket Option Kit
NOTE:
Used to secure one power enclosure in a rack when moving.
Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, up to 128 slots
1200mx, 6 drive, up to 128 slots
2200mx, 4 drive, up to 238 slots
2200mx, 6 drive, up to 238 slots
2200mx, 10 drive, up to 238 slots
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
ProLiant Cluster HA/F500 Enhanced Kit for Enterprise Virtual Array
ProLiant Cluster HA/F500 Basic Kit for Enterprise Virtual Array
NOTE:
For additional information regarding the HP ProLiant Cluster for ProLiant Cluster HA/F500
for Enterprise Virtual Array please see the following QuickSpecs at:
Server Console Switch 1 x 4 port (100-230 VAC)
IP Console Switch Box, 1 x 1 x 16
IP Console Switch Box, 3 x 1 x 16
CPU to Server Console Cable, 12’
CPU to Server Console Cable, 3’
CPU to Server Console Cable, 7’
IP CAT5 Cable 3’, 4 pack
IP CAT5 Cable 6’, 8 pack
IP CAT5 Cable 12’, 8 pack
IP CAT5 Cable 20’, 4 pack
IP CAT5 Cable 40’, 1 pack
TFT5600 Rack Keyboard Monitor
TFT7210R Rack Mounted 17" Monitor
NOTE:
For a complete list of Monitors please view the following URL:
http://h18004.www1.hp.com/products/monitors/
1U Rack Keyboard & Drawer (Carbon)
NOTE:
For additional information regarding Rack Options, please see the following URL:
DA - 11958 North America — Version 6 — September 24, 2004
Page 29
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Service and Support
Offerings
Services)
(HP Care Pack
NOTE:
The HP Care Pack services for ProLiant BL p-Class server blades, cover the server
blade and the p-Class blade enclosure that the server blade is installed in as well as
interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
Installation & Start-up Services
ProLiant BL p-Class Blade Server Hardware Installation
ProLiant BL p-Class Blade Server Hardware Installation, Electronic
ProLiant BL p-Class Enclosure and Server Blade Hardware Installation
ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic
Provides for the Installation and Start-up of Compaq's Rapid Deployment Pack on a Customer
supplied server designated as a Deployment Server. Includes the deployment of a single server.
This new server will be deployed using either one of the pre-configured scripts or an image. In
addition, the service will provide for the capture and storage of the configuration of the newly
deployed server and orientation on product usage. To be delivered during standard office ours,
standard office days.
Provides for the Installation and Start-up of Compaq's Rapid Deployment Pack on a Customer
supplied server designated as a Deployment Server. Includes the deployment of a single server.
This new server will be deployed using either one of the pre-configured scripts or an image. In
addition, the service will provide for the capture and storage of the configuration of the newly
deployed server and orientation on product usage. To be delivered during standard office ours,
standard office days. Electronic.
NOTE:
For more information, customer/resellers can contact
http://www.hp.com/hps/
.
UA203A
UA203E
UA204A
UA204E
UA205A
UA205E
UA206A
UA206E
UA219A
UA219E
U4971A
U4971E
U5683A
U5683E
DA - 11958 North America — Version 6 — September 24, 2004
Page 30
QuickSpecs
HP ProLiant BL30p Server Blade
Memory
ProLiant BL30p Server Blade (all models)
Standard Memory
Up to 4096-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional SDRAM DDR DIMM
memory expansion kits.
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1 GB)
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
Slot
300682-B21
287497-B21
257974-B21
DA - 11958 North America — Version 6 — September 24, 2004
Page 31
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
ProLiant BL p-Class
Server Blade Enclosure
with enhanced backplane
components
Operating and
Performance
Specifications for ProLiant
BLp-Class RJ-45 Patch
Panel 2 with Fiber Channel
pass through
Dimensions
Input Specifications
Individual Server Blade
Bay Ratings
Temperature Range
Relative Humidity
(non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.
Dimensions
Capability
Network Transfer Rate
Fiber Channel SAN
Connector
Cable Support
EMI
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.
Height
Width
Depth
Rated input voltage
Rated input current
Rated input Power
Rated input voltage
Rated input current
Rated input Power
Operating
Non-Operating
Operating
Non-Operating
Operating
Non-Operating
100 Base-TX
1000 Base-TX
Fiber Channel
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC
125 A at -48 VDC
6000 W
-43 VDC to -53 VDC
14.6 A at -48 VDC
700 W
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps
20 Mbps
100 Mbps
200 Mbps
1000 Mbps
Auto-rate negotiate between 2G and 1G
32 RJ-45 in the back.
16 Pluggable SFP optical cages in the front
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
Category 5 UTP (2 pair); up to 328 ft/100 m
Category 5E (4 pair); up to 328 ft (100 m)
SFP optical cable
Nominal -48 VDC
Nominal -48 VDC
DA - 11958 North America — Version 6 — September 24, 2004
Page 32
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for ProLiant
BL p-Class RJ-45 Patch
Panel
Dimensions
Capability
Network Transfer Rate
Connector
Cable Support
Power Requirements
Temperature Range
Relative Humidity
(non-condensing)
Wet Bulb Temperature
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.
100 Base-TX
1000 Base-TX
200 mA at + 5V DC; 500 mA at -48V
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps
20 Mbps
100 Mbps
200 Mbps
1000 Mbps
16 RJ-45 in the back
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
Category 5 UTP (2 pair); up to 328 ft (100 m)
Category 5E (4 pair); up to 328 ft (100 m)
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and
Performance
Specifications for ProLiant
BL p-Class GbE
Interconnect Switch
Dimensions
Weight
Performance
Forwarding Mode
MAC Addresses
Forwarding Table
Age Time
Memory
Compliance
Height
Width
Depth
11.5 lb/5.2 kg per interconnect switch
9.6 Gbps external port bandwidth per server blade enclosure (full duplex)
Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-
byte packets)
Non-blocking, full-wire speed for all connections
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
8,191 per interconnect switch; MAC address based filtering and MAC address packet
priority configuring
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 34
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for ProLiant
BL p-Class GbE2
Interconnect Switch
Dimensions
Weight
Performance
Forwarding Mode
MAC Addresses
Forwarding Table
Age Time
Memory
Compliance
Network Transfer
Rate
Connector
EMI
Safety
Power
Requirements
Temperature
Range
Relative Humidity
(non-condensing)
Wet Bulb
Temperature
NOTE:
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper
operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4
psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for
storage is 70 KPa.
Height
Width
Depth
12.0 lb/5.4 kg per interconnect switch
24 Gbps External port bandwidth per server blade enclosure (full duplex)
Forwarding rate 1.5 million pps per gigabit port (64-byte packets)
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
2,048 per interconnect switch
Maximum age: 1 to 65535 seconds; default: 300 seconds
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit)
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
UL/CUL Listed Accessory
CE
48VDC: 2040 mA, 98 W maximum (per interconnect switch without GbE2 Storage
Connectivity Kit)
48VDC: 2355 mA, 113 W maximum (per interconnect switch with GbE2 Storage
Connectivity Kit)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 35
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for
ProLiant BL p-Class
Power Enclosures
Dimensions
Weights
Input Requirements
Output Voltage
Specifications
Ambient Temperature
Range (See
Relative humidity,
non-condensing
(See
Wet Bulb
Temperature
NOTE:
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.
NOTE
)
NOTE
)
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
Height
Width
Depth
No Hot-Plug
Power Supplies
All Hot-Plug
Power Supplies
Rated input voltage
Rated input frequency
Rated input current
per side
Rated input power
per side
Power cord
Rated output voltage
Rated output current
Rated output power
Nominal power
Operating
Shipping
Operating
Non-operating
Operating
Non-operating
Single-Phase Model
5.25 in (13.34 cm)5.25 in (13.34 cm)
27.15 in (68.96 cm)27.15 in (68.96 cm)
17.60 in (44.7 cm)17.60 in (44.7 cm)
47.5 lb (21.55 kg)47.5 lb (21.55 kg)
99.5 lb (45.13 kg)
200 VAC to 240 VAC
50 Hz to 60 Hz50 Hz to 60 Hz
24A
5760 W9976 W
1 NEMA L6-30P per side
-48.8 VDC to -54 VDC-48.8 VDC to -54 VDC
99A
4298 W8310 W
4158 W at 208 VAC7202 W at 208 VAC
50° to 95° F
(10° to 35° C)
-22° to 140° F
(-30° to 60° C)
20% to 80%20% to 80%
5% to 95%5% to 95%
82.4° F (28° C)82.4° F (28° C)
101.7° F (38.7° C)101.7° F (38.7° C)
3-Phase Model
125.5 lb (56.93 kg)
200 VAC to 240 VAC line
to line
24A per phase
1 NEMA L15-30 per side
170A
50° to 95° F
(10° to 35° C)
-22° to 140° F
(-30° to 60° C)
DA - 11958 North America — Version 6 — September 24, 2004
Page 36
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for
ProLiant BL p-Class
Power Distribution
Devices
Power
Enclosures or facility DC
feeds Supported
(3U each)
Server blade enclosures
supported
(6U each)
Total rack height of
supported enclosures
Dimensions
Height
Width
Depth
Weight
Rated Operating
Voltage
Max Total Power
Supported
Total Max Input Current
At Minimum Voltage
Total Max Input Current
At Nominal Voltage
Max Current Per Power
Feed
Max Local Ambient
Temperature
NOTE:
All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.
Power Bus Box
1
1up to 3up to 5
9U
5.1 in (12.95 cm)
3.6 in (9.14 cm) each
3.25 in (8.26 cm)
3.62 lb (1.64 kg)
-43.2 VDC to -54 VDC-43.2 VDC to -54 VDC-43.2 VDC to -54 VDC
3000 W9000 W
69.44 A at -43.2VDC
62.5 A at -48VDC
70A70A
149° F (65° C)149° F (65° C)149° F (65° C)
Mini Bus Bar
1 or 21 or 2
24U36U
19.45 in (49.40 cm)
19.74 in (50.14 cm)19.74 in (50.14 cm)
2.2 in (5.59 cm)2.2 in (5.59 cm)
13.2 lb (5.9 kg)
208.32 A at -43.2 VDC
187.5 A at -48 VDC312.5 A at -48 VDC
Scalable Bus Bar
48.57 in (123.37 cm)
26 lb (11.79 kg)
15000 W
347.2 A at -43.2 VDC
(equivalent of 175A per
feed)
(equivalent of 175A per
feed)
210A
DA - 11958 North America — Version 6 — September 24, 2004
Page 37
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for
Facility DC
Voltage
Current
In-rush current
Input over-current
Max Input Current Slew
Rate
Max Rated Power
Connections and Cables
NOTE:
*All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds.
** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on
any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load
(non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with
an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12
feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure
for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert.
Nominal input voltage
Operating voltage range
Max Input voltage slew rate
Redundant feed voltages*
(A & B)
Ripple/Noise
Overshoot
Voltage transients
Max steady state input
current
Max steady state current per
feed/total
Power bus boxes
Mini bus bars
Scalable bus bars
Must support up to 2X the maximum operating current per server blade enclosure
(125 A) for up to 1.0 mS
Customer provided fusing for facility DC feeds that protects the system from
catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating
currents.
1A/uS
3000W per server blade enclosure
HP provided facility DC cable connection kit:
The facility DC connection kit supports the connection of up to four -48VDC,
RETURN pairs and ground
The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at
105° C, terminated with bus mating connectors at one end and unterminated at the
other end. The cable length provided enables the customer to route to a fuse panel
within or adjacent to the rack.
-48 VDC
-48VDC ± 10% or -43.2 VDC to -52.8 VDC
0.5V/uS
*A and B feeds must differ by no more than 5VDC
during steady state operation
480 mV PARD**
Must remain within regulation limits on all feeds during
startup or shutdown
Must not exceed -60 VDC
62.5A per server blade enclosure installed at -48VDC
70 A/70A
210 A/210A
210 A/350A or equivalent of 175A per feed*
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions
contained herein.
DA - 11958 North America — Version 6 — September 24, 2004
Page 38
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.