HP BC2500, BC2000 User Manual

Page 1
User Guide
HP BladeSystem PC Blade Enclosure Integrated Administrator v4.20
Page 2
© Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Microsoft and Windows are trademarks of Microsoft Corporation in the U.S. and other countries.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
This document contains proprietary information that is protected by copyright. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company.
User Guide
HP BladeSystem PC Blade Enclosure Integrated Administrator v4.20
Second Edition (February 2008)
First Edition (May 2007)
Document Part Number: 449377-002
Page 3
About This Book
WARNING! Text set off in this manner indicates that failure to follow directions could result in bodily
harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage
to equipment or loss of information.
NOTE: Text set off in this manner provides important supplemental information.
ENWW iii
Page 4
iv About This Book ENWW
Page 5
Table of contents
1 About This Guide
Audience Assumptions ......................................................................................................................... 1
Important Safety Information ................................................................................................................ 1
Symbols on Equipment ........................................................................................................................ 1
Related Documents .............................................................................................................................. 2
Getting Help ......................................................................................................................................... 2
Contact HP .......................................................................................................................... 2
Support and Troubleshooting .............................................................................................. 2
HP Web Site ........................................................................................................................ 2
2 HP PC Blade Enclosure System Software Features
HP PC Blade Enclosure Integrated Administrator ................................................................................ 3
Integrated Administrator Features ........................................................................................................ 3
Dedicated LAN Connectivity ................................................................................................ 3
SNMP Alerts from Integrated Administrator to a Management Console ............................. 4
E-mail Alerts from Integrated Administrator to an E-mail Account (AlertMail) ..................... 4
Remote Access and Control ................................................................................................ 4
User Administration and Security ........................................................................................ 4
Automatic Network Configuration ........................................................................................ 5
Automatic Time Configuration (NTP) ................................................................................... 5
SOAP Interface .................................................................................................................... 5
Power Reporting .................................................................................................................. 5
Integration with the HP Systems Insight Manager Utility ..................................................... 6
Integration with HP Session Allocation Manager (SAM) Utility ............................................ 6
Event Notification ................................................................................................................. 7
Overview of HP BladeSystem Software Tools ..................................................................................... 7
ROM-Based Setup Utility (RBSU) ....................................................................................... 7
Headless Operation ............................................................................................................. 7
ProLiant Essentials Rapid Deployment Pack ...................................................................... 7
HP Systems Insight Manager .............................................................................................. 7
Enclosure Self Recovery (ESR) ........................................................................................... 7
HP PC Blade Enclosure Management System and Utilities ................................................ 7
3 Getting Started
Reviewing Configuration Tools and Information ................................................................................... 9
Identifying Integrated Administrator Components .............................................................................. 10
Determining the Integrated Administrator’s Initial IP Address ............................................................ 10
Requirements for Local Client Devices .............................................................................. 11
Default Values for the Integrated Administrator ................................................................. 11
ENWW v
Page 6
Determining the IP Address Using the Local Console ....................................................... 12
Setting Up the Web-Based User Interface ......................................................................................... 13
Additional Steps ................................................................................................................................. 15
4 Web Browser Interface
Accessing the Web-based User Interface .......................................................................................... 16
Web-Based Navigation ....................................................................................................................... 17
Top Panel .......................................................................................................................... 17
Left Panel ........................................................................................................................... 17
Deck Panel ........................................................................................................................ 18
Enclosure Tab .................................................................................................................................... 19
Enclosure Information ........................................................................................................ 19
Network Configuration ....................................................................................................... 23
SNMP Configuration .......................................................................................................... 25
Power Readings ................................................................................................................ 27
Virtual Buttons ................................................................................................................... 28
System Log ........................................................................................................................ 29
System Log Policy ............................................................................................................. 30
Bays Tab ............................................................................................................................................ 31
Bay List .............................................................................................................................. 31
Bay Information .................................................................................................................. 32
Remote Console ................................................................................................................ 34
Virtual Buttons ................................................................................................................... 35
Console Log ....................................................................................................................... 37
Bay Power Consumption ................................................................................................... 37
Administration Tab ............................................................................................................................. 39
User List ............................................................................................................................. 39
Group List .......................................................................................................................... 40
Add User ............................................................................................................................ 41
Add Group ......................................................................................................................... 42
View/Modify User ............................................................................................................... 44
View/Modify Group ............................................................................................................ 44
Event List Tab .................................................................................................................................... 45
Event Log Policy ................................................................................................................ 46
Interconnect Tab ................................................................................................................................ 47
5 Command Line Interface
Accessing the Command Line Interface ............................................................................................. 50
Accessing Remotely through the Management Connector ............................................... 50
Accessing Locally through the Console Connector ........................................................... 50
Operating the Command Line Interface ............................................................................................. 51
General Commands ........................................................................................................... 51
General Management Commands ..................................................................................... 51
User Account Commands .................................................................................................. 53
Enclosure Network Configuration Commands ................................................................... 57
Enclosure Management Commands ................................................................................. 59
Blade PC Bay Management Commands ........................................................................... 62
Command Line Event Messages ....................................................................................... 64
Functionality Exclusive to the Command Line Interface ..................................................................... 67
vi ENWW
Page 7
6 Setting Up the System
User Permissions ............................................................................................................................... 72
Customizing the Enclosure Settings ................................................................................................... 73
Modifying Enclosure and Rack Names .............................................................................. 73
Modifying the Asset Tag Number ...................................................................................... 74
Modifying the Date and Time ............................................................................................. 75
Setting Up User Accounts .................................................................................................................. 77
Adding a Group .................................................................................................................. 77
Adding a User .................................................................................................................... 79
Enabling Remote Console Sessions to Blade PCs ............................................................................ 82
Setting Up AlertMail ............................................................................................................................ 82
E-mail Alerts ...................................................................................................................... 83
Setting Up IP Security ........................................................................................................................ 84
Setting Up Automatic Time Configuration (NTP) ................................................................................ 85
Configuring SNMP Support ................................................................................................................ 86
Entering a Community String ............................................................................................. 86
Modifying the System Location .......................................................................................... 87
Modifying the System Contact Information ........................................................................ 87
Adding Trap Targets .......................................................................................................... 87
Removing Trap Targets ..................................................................................................... 88
7 Configuring SOAP Support Tasks
Enabling SOAP Interface ................................................................................................................... 89
Disabling SOAP Interface ................................................................................................................... 89
Supported SOAP Interface Commands ............................................................................................. 90
8 Performing Common Administrative Tasks
Managing Blade PC Bays .................................................................................................................. 91
Opening a Remote Console Session to a Blade PC ......................................................... 91
Accessing the ROM-Based Setup Utility for a blade PC ................................................... 92
Reviewing Activity for a Blade PC ..................................................................................... 94
Powering Off the Blade PC ................................................................................................ 94
Identifying a Blade PC Using the Unit Identification LED .................................................. 95
Managing the Enclosure ..................................................................................................................... 97
Reviewing the Activity of the Enclosure ............................................................................. 97
Identifying the Enclosure Using the Unit Identification LED ............................................... 99
Generating an Enclosure Summary ................................................................................... 99
Identifying Problem Components ..................................................................................... 101
Managing Users ............................................................................................................................... 105
Modifying a User’s Rights to Blade PC Bays ................................................................... 105
Creating a New Group with the Updated Access Rights ................................. 105
Modifying Group Rights to Blade PC Bays ..................................................... 105
Disabling and Deleting User Accounts ............................................................................ 107
Deleting a User Account ................................................................................. 108
Deleting Group Accounts ................................................................................ 109
9 Performing Advanced Functions
Replicating the Configuration of the Integrated Administrator .......................................................... 112
Administering Security Certificates ................................................................................................... 112
ENWW vii
Page 8
Creating a Certificate Request ......................................................................................... 113
Downloading a Security Certificate .................................................................................. 113
Key-Based SSH Authentication ........................................................................................................ 113
Configuring Blade PC Boot Order .................................................................................................... 114
Powering Off the Enclosure .............................................................................................................. 115
Disabling Network Protocols ............................................................................................................ 116
Upgrading the Integrated Administrator Firmware ........................................................................... 117
Recovering a Lost Administrator Password ..................................................................................... 117
Launching Flash Disaster Recovery ................................................................................................. 118
Appendix A Command Line Conventions
Appendix B Error Messages
Warning Messages ........................................................................................................................... 122
Enclosure Warning Messages ......................................................................................... 122
Blade PC Warning Messages .......................................................................................... 123
Administration Warning Messages .................................................................................. 123
Error Messages ................................................................................................................................ 124
Enclosure Error Messages .............................................................................................. 124
Blade PC Bay Error Messages ........................................................................................ 124
Administration Error Messages ........................................................................................ 124
Appendix C Blade PC Diagnostic Messages
Appendix D Maskable Enclosure System Log Messages
Appendix E Maskable Enclosure Event Messages
Appendix F Troubleshooting
Appendix G Event Icons and Details
Appendix H Factory Default Settings
Enclosure ......................................................................................................................................... 138
Users ................................................................................................................................................ 138
Groups .............................................................................................................................................. 140
Network ............................................................................................................................................ 140
Protocol ............................................................................................................................................ 140
Appendix I Time Zone Settings
Universal .......................................................................................................................................... 141
Africa ................................................................................................................................................ 142
Asia .................................................................................................................................................. 142
Europe .............................................................................................................................................. 143
Oceania ............................................................................................................................................ 144
Polar ................................................................................................................................................. 145
Americas .......................................................................................................................................... 145
viii ENWW
Page 9
Appendix J Open Source Availability
Appendix K Supported SNMP Traps
Index ................................................................................................................................................................. 150
ENWW ix
Page 10
x ENWW
Page 11

1 About This Guide

Audience Assumptions

This guide is for the person who installs, administers, and troubleshoots HP Blade PC solutions. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Important Safety Information

WARNING! Before installing this product, read the Important Safety Information document included
with the system.

Symbols on Equipment

The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions:
This symbol, in conjunction with any of the following symbols, indicates the presence of a potential hazard. The potential for injury exists if warnings are not observed. Consult your documentation for specific details.
This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.
ENWW Audience Assumptions 1
Page 12
WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.
This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.

Related Documents

For additional information on the topics covered in this guide, refer to the following documents:
Network Considerations Guide white paper
QuickSpecs
Setup and Installation Guide: HP BladeSystem bc2000 and bc2500 Blade PC and PC Blade
Enclosure
HP Rack 9000 and 10000 Series installation and best practices white paper
Installation Guide: HP BladeSystem PC Blade Switch
Command Line Interface Reference Guide: HP BladeSystem PC Blade Switch
Embedded Web System User Guide for the HP BladeSystem PC Blade Switch

Getting Help

If you have a question about the HP PC Blade Enclosure and have exhausted the information in this guide, you can get additional information and other help in the following locations:

Contact HP

The Contact HP Web site provides various ways to contact HP, including online chat, e-mail, and telephone. Access this Web site at

Support and Troubleshooting

HP’s Support and Troubleshooting Web site allows you to download software and drivers and search for support and troubleshooting information for specific products. Access this Web site at
http://welcome.hp.com/country/us/en/support.html.

HP Web Site

The HP Web site has information on this product as well as the latest drivers and flash ROM images. You can access the HP Web site at
http://welcome.hp.com/country/us/en/contact_us.html.
http://www.hp.com.
2 Chapter 1 About This Guide ENWW
Page 13
2 HP PC Blade Enclosure System
Software Features
The HP BladeSystem offers an extensive set of features and optional tools to support effective blade PC management and software deployment. This chapter describes the HP PC Blade Enclosure Integrated Administrator and provides a brief overview of software associated with the system.

HP PC Blade Enclosure Integrated Administrator

The HP PC Blade Enclosure Integrated Administrator is a centralized management and monitoring system for the HP PC Blade Enclosure and blade PCs. The Integrated Administrator acts as a combination console server and remote power controller, enabling in-band (default) or out-of-band, secure, serial console connections to all blade PCs in the enclosure.
The Integrated Administrator provides enclosure health, blade health, and enables remote blade manageability. Integrated Administrator features can be accessed from any network-based client. The Integrated Administrator can provide provide remote access to any authorized network client, sends alerts, and provides many other blade PC management functions.
The Integrated Administrator subsystem is embedded on a module included with each interconnect tray and includes an intelligent microprocessor, secure memory, and a dedicated network interface that can be configured for either in-band (default) or out-of-band remote access. This design makes the Integrated Administrator independent of the host blade PC and its operating system.

Integrated Administrator Features

The following subsections describe Integrated Administrator functions that deliver management of the enclosure and blade PCs.

Dedicated LAN Connectivity

Each Integrated Administrator provides a dedicated network connection. The uplink port 42 can auto­select speeds between 10 Mbps and 100 Mbps. When the PC Blade Switch (optional) is installed, by default the Integrated Administrator is configured to route through a Gigabit uplink connector using VLANs, eliminating the need for a separate management network.
NOTE: The default configuration for the HP BladeSystem PC Blade Switch option has the dedicated
IA port and both uplink ports 45 and 46 in the same VLAN.
ENWW HP PC Blade Enclosure Integrated Administrator 3
Page 14

SNMP Alerts from Integrated Administrator to a Management Console

The Integrated Administrator provides notification of enclosure problems. Using a management console, you can access various alerts, such as unauthorized access attempts and network connection failures using SNMP traps.
The CPQRACK.MIB file contains HP-specific SNMP Object Identifiers (OIDs) and traps for managing the enclosure infrastructure and blades. The Integrated Administrator 4.2 implements support for CPQRACK version 1.8.

E-mail Alerts from Integrated Administrator to an E-mail Account (AlertMail)

AlertMail enables the Integrated Administrator to send system events by e-mail instead of using SNMP traps. AlertMail is completely independent of SNMP, and both can be enabled at the same time. AlertMail uses standard SMTP commands to communicate with any SMTP capable mail server or in addition to SMTP relay agent.

Remote Access and Control

The Integrated Administrator provides remote functionality to access a limited text-only console of the host blade PC, change the state of the Unit Identification LED on an enclosure or any of its blade PCs, and power up, power down, or reboot a blade PC or groups of blade PCs.
The Integrated Administrator displays alerts regardless of the state of the blade PC and integrates with HP Systems Insight Manager using SNMP to provide alerts and diagnostics of the system.
If a blade PC does not respond, this feature enables an administrator to initiate a cold reboot to bring the blade PC back online. The Integrated Administrator can be used to remotely operate a power button or Unit Identification LED (UID) of any blade PC within the enclosure.
The Integrated Administrator is fully accessible by common Web browsers. The Integrated Administrator also has a command line interface (CLI) accessible using Secure Shell (encrypted) or Telnet (unencrypted) protocols, providing extensive management capability to remote network users. Local users can access the CLI by attaching a client computer (using a terminal emulator) to the Integrated Administrator’s console (RS-232 serial) port.
NOTE: With a Telnet session, all data - including passwords - are passed as clear text.

User Administration and Security

The Integrated Administrator supports up to 25 users with customizable access rights and login names. Groups are first assigned bays, and then users are given membership to those groups. This group­centered methodology is designed to facilitate user management across blade PCs.
The Integrated Administrator provides strong security for remote management in distributed IT environments by using industry standard Secure Sockets Layer (SSL) encryption of HTTP data transmitted across the network. SSL encryption (up to 128-bit) ensures that the HTTP information is secure as it travels across the network. You can encrypt all remote console data as well.
4 Chapter 2 HP PC Blade Enclosure System Software Features ENWW
Page 15
The Integrated Administrator provides secure password encryption, tracking all login attempts and maintaining a record of all login failures. The Integrated Administrator also provides the following additional security features:
User actions logged in the Integrated Administrator System Log
Login legal warning
IP Security allows an administrator to define a set of IP addresses that are the only ones allowed to connect to the services provided (SSH, HTTP, HTTPS, TELNET, SNMP). This means that an administrator can make sure only a certain set of machines have access to the Integrated Administrator.

Automatic Network Configuration

The Integrated Administrator provides automatic network configuration of the IP address and host name using Dynamic Host Configuration Protocol (DHCP) and Dynamic DNS/WINS. The Integrated Administrator comes with a default name and DHCP client that leases an IP address from the DHCP server on the network. For networks that do not use DHCP, the Integrated Administrator can use a static IP configuration.

Automatic Time Configuration (NTP)

Automatic time configuration allows the Integrated Administrator to synchronize its date and time with a compatible Network Time Protocol (NTP) Time Server.

SOAP Interface

The Integrated Administrator provides a handful of commands via the Simple Object Access Protocol (SOAP) interface for manageability tools that utilize SOAP. This interface provides a handful of commands for inventory and power management of the enclosure and blades managed by the IA. All Administrator access level accounts can use the SOAP interface, and it is enabled using a command line (CLI) command or the GUI.

Power Reporting

The Integrated Administrator collects power measurements from BC2000/BC2500 blades and reports them via the CLI and GUI. These blades self measure using hardware measurement components specifically in the BC2000/BC2500 series of blades. Using these measurements, a +-10% estimate of power consumption for the enclosure is calculated. The overall enclosure power consumption estimate can be collected by the CLI, GUI, and SOAP interface.
ENWW Integrated Administrator Features 5
Page 16

Integration with the HP Systems Insight Manager Utility

The Integrated Administrator provides full integration with the HP Systems Insight Manager utility under key operating environments. This integration provides:
Support for SNMP management—Support for SNMP trap delivery to a HP Systems Insight
Manager console
Management processor—The HP Systems Insight Manager utility adds support for a new device
type, the management processor. All Integrated Administrators (in HP PC Blade Enclosure) on the network are discovered in the HP Systems Insight Manager utility as management processors. The management processors are associated with the blade PCs they manage.
The Integrated Administrator hyperlinks—The HP Systems Insight Manager utility provides a
hyperlink on the blade PC device page to launch and connect to the Integrated Administrator.
Grouping of Integrated Administrator processors—All Integrated Administrator management
processors can be grouped together logically and displayed on one page in HP Systems Insight Manager. This capability provides access to all Integrated Administrators on the network from one point in HP Systems Insight Manager.
For more information on the HP Systems Insight Manager utility, refer to the ProLiant Essentials Foundation Pack documentation that ships with the system or refer to
products/servers/management/hpsim/index.html.
http://h18013.www1.hp.com/

Integration with HP Session Allocation Manager (SAM) Utility

The Integrated Administrator provides features for the HP Session Allocation Manager software to manage and report on the hardware. HP SAM leverages the SOAP interface to gather power reporting data and power manage the blades within the enclosure. The Integrated Administrator has a built-in
6 Chapter 2 HP PC Blade Enclosure System Software Features ENWW
Page 17
account that is provided for ease of implementing within a deployment that uses HP SAM. This account is disabled by default.

Event Notification

The Integrated Administrator provides real-time event notifications for an enclosure. When an event occurs, the Integrated Administrator notifies connected users by generating an icon that the user can click to view more details.

Overview of HP BladeSystem Software Tools

The following subsections described tools and utilities supported by the HP BladeSystem blade PC systems to facilitate monitoring and management of the enclosure.

ROM-Based Setup Utility (RBSU)

RBSU performs a wide range of configuration activities and provides access to numerous settings, including those for system devices, operating system selection, and boot controller order. RBSU is also fully compatible with remote serial console mode using the Integrated Administrator.

Headless Operation

HP bc-series blade PCs include VGA, keyboard, mouse, and USB interfaces; however, these blade PCs are designed primarily for headless operation and management with no keyboard or monitor attached.

ProLiant Essentials Rapid Deployment Pack

The ProLiant Essentials Rapid Deployment Pack features a graphical deployment console, which provides intuitive drag-and-drop events, such as scripts and images, to deploy the operating systems and applications on any combination of blade PCs installed in the enclosures.
With the Rapid Deployment Pack, users can automatically install pre-defined configurations on newly installed blade PCs. For more information about the Rapid Deployment Pack, refer to an authorized reseller, the Rapid Deployment CD that ships with the enclosure, or go to
http://www.hp.com/go/rdp.

HP Systems Insight Manager

HP Systems Insight Manager is a software utility designed for collecting blade PC information, including fault conditions, performance, security, remote management, and recovery services. The HP BladeSystem is fully compatible with the HP Systems Insight Manager utility.

Enclosure Self Recovery (ESR)

ESR is a self-monitoring reliability feature of the Integrated Administrator. If the Integrated Administrator does not boot or hangs during operation, ESR automatically resets the Integrated Administrator for an attempted self-recovery. The blade PCs and interconnect tray are not affected by ESR.

HP PC Blade Enclosure Management System and Utilities

The HP PC Blade Enclosure Management System and Utilities provide a full suite of configuration and management interfaces and tools for the HP PC Blade Enclosure (option). Both Web and console interfaces are provided for management of the interconnect switch and enclosure.
ENWW Overview of HP BladeSystem Software Tools 7
Page 18
You can configure both interfaces to require a valid user name and password for authentication. RMON (for the switch) and SNMP manageability are supported. You can also save the interconnect switch configuration to a TFTP server as backups and as templates for preconfiguring other switches.
8 Chapter 2 HP PC Blade Enclosure System Software Features ENWW
Page 19

3 Getting Started

The HP PC Blade Enclosure Integrated Administrator enables monitoring and management of all functions within an enclosure, including functions specific to the blade PCs housed within it. Once configured, the Integrated Administrator provides these features through both a Web-based user interface and CLI.
This chapter addresses first-time configuration of the Integrated Administrator after the enclosure is installed and powered up in a rack:

Reviewing configuration tools and information

Identifying the Integrated Administrator connectors
Determining the Integrated Administrator initial IP address
Setting up the Web-based user interface
Additional steps
Help
Reviewing Configuration Tools and Information
The Integrated Administrator is ready for operation immediately after powering up. The following features and information are designed to facilitate the setup and management of the Integrated Administrator:
Each Integrated Administrator ships with a unique preconfigured Administrator password and host
name.
If the network uses Dynamic DNS or WINS, you can access the Integrated Administrator using the
factory-configured host name.
NOTE: The preconfigured Administrator password and host name are displayed on the
Integrated Administrator Default Network Settings Tag (settings tag) attached to the interconnect tray.
If the network uses DHCP, an IP address can be automatically assigned to the Integrated
Administrator.
The blade PC health service (if installed on the blade) provides the Integrated Administrator with
the name as defined within the operating system of the blade PC and operating system type for each blade PC.
CAUTION: Without an ACPI-compliant operating system, the Integrated Administrator cannot
gracefully shut down a blade PC. This condition may result in the permanent loss of critical data.
ENWW Reviewing Configuration Tools and Information 9
Page 20

Identifying Integrated Administrator Components

Each HP PC Blade Enclosure interconnect tray ships with the Integrated Administrator module already installed and provides external connectivity using two connectors on the rear panel.
Table 3-1 Integrated Administrator Rear Panel Components
Item Description
1 Management (10/100 Ethernet) connector for remote access through a Web-based user interface, Telnet,
or Secure Shell.
2 Console (serial) connector for local access to the command line interface using a laptop computer.
3 Integrated Administrator reset button.
4 Integrated Administrator health LED
5 Enclosure Unit Identification button/LED

Determining the Integrated Administrator’s Initial IP Address

HP recommends that you connect a local client device, such as a laptop computer, to the console (serial) connector in order to determine the initial IP address used by the network to recognize the Integrated Administrator. After using that IP address to access the Integrated Administrator locally using the console (serial) connector, you can use the Integrated Administrator default values to complete the initial configuration.
The organization of this section reflects this process:
Requirements for local client devices
Default values for the Integrated Administrator
Determining the IP address using the local console
10 Chapter 3 Getting Started ENWW
Page 21

Requirements for Local Client Devices

You can access the Integrated Administrator locally using the serial connector on the rear panel of the enclosure using a local client device, such as a laptop computer. The local client device must run a terminal emulator, such as HyperTerminal for Windows systems or Kermit for Linux systems.
The terminal emulator must operate at the following settings:
Bits per second: 9600
Bits: 8
Parity: None
Stop bits: 1
Flow control: none
Emulation: VT100
Backspace key sends Ctrl-H

Default Values for the Integrated Administrator

The Integrated Administrator is configured with a default user name, password, and DNS name. A settings tag with the preconfigured values is attached to the interconnect tray containing the Integrated Administrator module. There is also a built-in administrator account for SOAP access, which is disabled by default.
Username: SAM
Default Password: SamUser123
NOTE: This administrator account is disabled by default. You cannot login using this account
until you enable the SAM account.
It is important that the account password is changed from the default account password if the account is enabled prior to normal usage by HP SAM. Lastly, the SOAP interface for all other accounts is disabled by default, but is always enabled for the SAM account.
NOTE: For security reasons, HP recommends changing the Administrator password after accessing
Integrated Administrator for the first time.
ENWW Determining the Integrated Administrator’s Initial IP Address 11
Page 22

Determining the IP Address Using the Local Console

To determine the Integrated Administrator IP address using the local console perform the following steps:
1. Access the Integrated Administrator console:
a. Connect a local client device (such as a laptop computer) with VT100 terminal emulation
software to the Integrated Administrator (serial) console connector using a null modem serial cable.
b. Open a terminal emulation session with the following settings: 9600 bps, 8 data bits, no parity,
and 1 stop bit.
c. Log into the Integrated Administrator using the password on the settings tag attached to the
interconnect tray.
2. Establish the Integrated Administrator IP address.
For a detailed explanation of the command line conventions used in this document, see
Line Conventions on page 121.
If a DHCP server is attached to the network, determine the Integrated Administrator IP address. Type the following command at the command line interface:
SHOW NETWORK
If a DHCP server is not attached to the network, type the following commands sequentially to assign a static IP address to the Integrated Administrator:
SET IPCONFIG STATIC <IP address><subnet mask>
SET GATEWAY <IP address>
SET DNS <primary address> {<secondary address>}
You can now access the Integrated Administrator using a Web browser, Secure Shell, Telnet, or SNMP.
CAUTION: All settings are immediate and can only be manually restored.
Command
12 Chapter 3 Getting Started ENWW
Page 23

Setting Up the Web-Based User Interface

To set up the Web-based user interface, proceed as follows:
1. Type the Integrated Administrator IP address or DNS name in the address bar of the Web browser.
A security alert displays as shown below.
If you click Yes, the browser continues to the Login window of Integrated Administrator. The alert message appears each time you access the Integrated Administrator management processor in a browser.
If you click No, you are returned to what was previously displayed on your browser.
If you click View Certificate, a popup window displays the certificate information. Installing the certificate to your browser prevents the security alert message from displaying in the future.
NOTE: To install your own certificate onto the Integrated Administrator rather than the
automatically generated certificate, see the information on certificate-related commands in
Administering Security Certificates on page 112.
If the certificate is removed from your browser, the security alert message is displayed again.
2. Install the certificate to your browser:
a. Click Install Certificate. The Certificate Manager Import Wizard starts.
b. Click Next.
c. Click Next for the browser to automatically select the certificate store when the Certificate
Store window appears.
d. Click Finish when the Completing the Certificate Manager Import Manager Wizard window
displays.
e. Click Yes to confirm the installation of the certificate when the confirmation window displays.
ENWW Setting Up the Web-Based User Interface 13
Page 24
3. The Account Login screen (shown below) prompts you for a user name and password. Use the
default user name and password from the settings tag attached to the interconnect tray, and then click Log In.
After the default user name and password have been verified, the summary window appears.
The Integrated Administrator summary window provides general information about the Integrated Administrator, such as the user currently logged on, enclosure name and status, and Integrated Administrator IP address and name.
14 Chapter 3 Getting Started ENWW
Page 25

Additional Steps

HP recommends performing the following tasks:
Change the Administrator password
Set the date and time
Name the enclosure and rack
Set up groups, users, and access privileges
For detailed instructions on performing these tasks, see the appropriate sections in
System on page 71.
Setting Up the
ENWW Additional Steps 15
Page 26

4 Web Browser Interface

This chapter provides information for navigating the Integrated Administrator Web-based user interface:
NOTE: Values appearing in the screens of this chapter are for illustrative purposes only.

Accessing the Web-based User Interface

Accessing the Web-based user interface is not supported from the console (serial) connector.
To access the Integrated Administrator Web-based user interface with HTTP:
1. Get the DNS name from the settings tag attached to the interconnect tray.
2. Open a Web browser and type the IP address or DNS name for the enclosure to access.
CAUTION: If your network does not provide DHCP and either Dynamic DNS or WINS services,
you need to configure a static IP address. See
Console on page 12.
Determining the IP Address Using the Local
3. Type the user name and password at the Login prompt.
16 Chapter 4 Web Browser Interface ENWW
Page 27

Web-Based Navigation

The Web-based user interface displays information and receives input in the following areas:

Top panel

Left panel

Deck panel
Top Panel
The following illustration shows the location of the top panel.
The top panel information is displayed at all times, including the following items:
The Integrated Administrator top panel provides real-time event notifications for an enclosure according to two categories: caution and critical. When an event occurs, the Integrated Administrator notifies the user by generating an icon that the user can click to view more details:
Icon Descripton
Two buttons appear on the top panel:
Left Panel
Enclosure name
Current user
Tabs
Caution
Critical
Printable View—Opens a separate window that shows information for cutting and pasting purposes.
Log Out—Logs you out of the Web-based user interface.
The following illustration shows the location of the left panel.
ENWW Web-Based Navigation 17
Page 28
The left panel displays which screens are available under each tab. Information appearing in the left panel depends on which tab the user chooses from within the top panel.

Deck Panel

The following illustration indicates the position of the deck panel.
18 Chapter 4 Web Browser Interface ENWW
Page 29
The deck panel displays the areas of information provided by the available screens under each tab. Information appearing in the deck panel depends on the option chosen by the user from within the top panel and the left panel.

Enclosure Tab

The Enclosure tab provides access to the following screens:

Enclosure Information

Network Configuration
SNMP Configuration
Power Readings
Virtual Buttons
System Log
System Log Policy
Enclosure Information
All users have read access to the information in this screen.
ENWW Enclosure Tab 19
Page 30
The following illustration shows the information presented on the Enclosure Information screen (status area, one of six shown).
The Enclosure Information screen enables an enclosure administrator to update the rack name, enclosure name, asset tag, time zone, date, and time, as well as observe the status and general information for every component in the enclosure.
Two buttons appear on the Enclosure Information screen:
Apply—Saves changes made to the screen.
Cancel—Restores all fields on the screen to their original values.
The following table describes the information displayed in the areas that comprise the Enclosure Information screen.
Table 4-1 Enclosure Information Field Descriptions—Status Area
Field Possible Values Description
Status Area
Enclosure Name
Rack Name Maximum 32 characters including all
Maximum 32 characters including all alphanumeric, dash, and underscore characters.
alphanumeric, dash, and underscore characters.
Name of enclosure.
Only enclosure administrators have write access to this field.
For the default enclosure name, see
Default Settings on page 138.
Name of rack.
Only enclosure administrators have write access to this field.
Factory
20 Chapter 4 Web Browser Interface ENWW
Page 31
Table 4-1 Enclosure Information Field Descriptions—Status Area (continued)
For the default rack name, see Factory Default
Settings on page 138.
Enclosure Status OK, Degraded, or Failed. Status of the enclosure.
Fan Status Redundant or non-redundant. Redundant: all fans are functional. Non-
Fan #1—Fan #4 OK, Standby, Degraded, Failed, or Testing.
Percentage of full fan speed.
Fan Spare Number The spare number for the fans installed in the
Temperature OK, Warm, Caution, or Critical. Enclosure component temperature sensor.
redundant: at least one fan is not functional.
Status of fans 1 through 4.
enclosure.
Table 4-2 Enclosure Information Field Descriptions—Power Area
Field Possible Values Description
Power Area
Power Subsystem Status
Total Capacity Watts. Total capacity of the power supplies.
Power Supply #1 and #2 Status OK, Degraded, or Failed. Status of power supply #1 and power
AC Input #1 and #2 Status OK, Degraded, or Failed. Status of AC input to power supply #1
Redundant or Non-redundant. Redundant: both power supplies are
functional. Non-redundant: one power supply is not functional.
supply #2.
and AC input to power supply #2.
Power Supply Spare Number The spare number for the power supplies
installed in the enclosure.
Table 4-3 Enclosure Information Field Descriptions—General Area
Field Possible Values Description
General Area
Enclosure Type
Part Number Part number for the enclosure.
Serial Number Serial number for the enclosure.
Asset Tag Maximum 31 characters including all
Interconnect Tray Type HP PC Blade Enclosure Interconnect
Enclosure product type.
Asset tag alphanumeric, dash, and underscore characters
Switch
HP PC Blade Enclosure RJ-45 Interconnect Patch Panel
Only enclosure administrators have write
access to this field.
For the default asset tag value, see
Factory Default Settings on page 138.
Type of interconnect tray.
Interconnect Tray Part Number Part number for the interconnect tray.
ENWW Enclosure Tab 21
Page 32
Table 4-3 Enclosure Information Field Descriptions—General Area (continued)
Interconnect Tray Spare Number Spare number for the interconnect tray.
Interconnect Tray Serial Number Serial number for the interconnect tray.
Table 4-4 Enclosure Information Field Descriptions—Integrated Administrator Area
Field Possible Values Description
Integrated Administrator Area
Hardware Version
Software Version Software version of the Integrated
Hardware version of the Integrated
Administrator of the enclosure.
Administrator of the enclosure. Additionally, build version is displayed.
Table 4-5 Enclosure Information Field Descriptions—Network Area
Field Possible Values Description
Network Area
IP Address
DHCP Enabled or Disabled. Shows the status of the Dynamic DNS
MAC Address ##:##:##:##:##:## where ## ranges from
###.###.###.###, where ### ranges from 0 to 255.
00 to FF.
The IP address of the Integrated Administrator.
This field appears only if DHCP is enabled.
The MAC address of the Integrated Administrator.
Table 4-6 Enclosure Information Field Descriptions—Date and Time Area
Field Possible Values Description
Date and Time Area
Time Zone
Date mm/dd/yy The date assigned to the enclosure
Time hh:mm (24-hour format) The time assigned to the enclosure
Drop-down box with standard time zones listed
Time zone assigned to the enclosure
For the default time zone, see
Default Settings on page 138.
For a list of all supported time zones, see
Time Zone Settings on page 141.
For a detailed description of how to set the time zone of the enclosure to a value not listed in the drop down box, select Other.
For additional information, see
Troubleshooting on page 134.
Factory
22 Chapter 4 Web Browser Interface ENWW
Page 33
Only enclosure administrators have access to the Date and Time information. If those fields are not being modified, the Integrated Administrator updates these fields every 20 seconds. If automatic time configuration is enabled, the date and time fields are grayed out and cannot be modified.
If you select Other for time zone, use the following window to set a user-defined time zone:
Three buttons appear on this window:
Apply—Applies the new time zone.
Reset—Clears the time zone text box.
Cancel—Cancels all changes and closes the window.
For more information on accepted time zones, refer to

Network Configuration

NOTE: Only enclosure administrators have access to these settings.
The Network Configuration screen (shown below) enables the enclosure administrator to modify the network settings of an enclosure. These settings are specific to the enclosure and do not affect the network configurations for blade PCs.
Time Zone Settings on page 141.
ENWW Enclosure Tab 23
Page 34
Two buttons appear at the bottom of this screen:
Apply—Saves changes made to the screen.
Cancel—Restores all fields on the screen to their original values.
CAUTION: Both the Web and Secure Shell protocols must be enabled to allow access to the Web-
based user interface.
The following table describes the information displayed in the areas that comprise the Network Configuration screen.
Table 4-7 Network Configuration Field Descriptions—Information Area
Field Possible Values Description
Information Area
IP Address
MAC Address The MAC address of the Integrated
The IP address of the Integrated
Administrator.
Administrator.
Table 4-8 Network Configuration Field Descriptions—Protocols Area
Field Possible Values Description
Protocols Area
Web (HTTP/HTTPS)
Enabled or Disabled. The default setting is Enabled.
24 Chapter 4 Web Browser Interface ENWW
Page 35
Table 4-8 Network Configuration Field Descriptions—Protocols Area (continued)
SNMP Enabled or Disabled. The default setting is Enabled.
Secure Shell Enabled or Disabled. The default setting is Enabled.
Telnet Enabled or Disabled. The default setting is Enabled.
SOAP Enabled or Disabled. The default setting is Disabled.
Table 4-9 Network Configuration Field Descriptions—Network Area
Field Possible Values Description
Network Area
DHCP
Static IP Sets a static IP address of the Integrated
Dynamic DNS Determines whether the Integrated
IP Address ###.###.###.###, where ### ranges
Subnet Mask ###.###.###.###, where ### ranges
Gateway Address ###.###.###.###, where ### ranges
DNS Server 1 ###.###.###.###, where ### ranges
DNS Server 2 ###.###.###.###, where ### ranges
Gets the IP address of the Integrated
Administrator from the DHCP.
Administrator.
Administrator uses Dynamic DNS.
Static IP address for the Integrated from 0 to 255.
from 0 to 255.
from 0 to 255.
from 0 to 255.
from 0 to 255.
Administrator (mandatory if Static IP is
selected).
Subnet mask for the Integrated
Administrator (mandatory if Static IP is
selected).
Gateway address for the Integrated
Administrator (optional field if Static IP is
selected).
The IP address for the primary DNS
server (optional field if Static IP is
selected).
The IP address for the secondary DNS
server (optional field if Static IP is
selected).

SNMP Configuration

The SNMP Configuration screen (shown below) enables an enclosure administrator to modify the SNMP settings of an enclosure. These settings are specific to the enclosure and do not affect the network configurations for blade PCs.
Two buttons appear at the bottom of this screen:
Apply—Saves changes made to the screen.
Cancel—Restores all fields on the screen to their original values.
ENWW Enclosure Tab 25
Page 36
The following table describes the information presented on the SNMP Configuration screen:
Table 4-10 SNMP Configuration Field Descriptions—System Information Area
Field Possible Values Description
System Information Area
SNMP Status
System Name The name of the enclosure.
System Location Up to 20 characters including all
System Contact Up to 20 characters including all
Enabled or Disabled Displays if SNMP is enabled or disabled.
alphanumeric, dash, underscore, and space characters
alphanumeric, dash, underscore, and space characters
The SNMP location of the enclosure
For the default SNMP contact, see
Factory Default Settings on page 138.
The SNMP contact of the enclosure
For the default SNMP contact, see
Factory Default Settings on page 138.
Table 4-11 SNMP Configuration Field Descriptions—Community Strings and Trap Destinations Area
Field Possible Values Description
Community Strings and Trap Destinations Area
Read Community
Up to 20 characters including all alphanumeric, dash, underscore, and space characters
Displays the SNMP read community string
If this is left blank, “public” is assigned.
26 Chapter 4 Web Browser Interface ENWW
Page 37
Table 4-11 SNMP Configuration Field Descriptions—Community Strings and Trap Destinations Area
(continued)
For the default read Community string,
see
Factory Default Settings
on page 138.
Write Community Up to 20 characters including all
Add Adds an IP address to the list of trap
Remove Removes the selected IP addresses

Power Readings

alphanumeric, dash, underscore, and space characters
Sets the SNMP write community string
If this is left blank, SNMP SET
commands are disabled.
For the default write Community string,
see Factory Default Settings
on page 138.
destinations.
from the list of trap destinations.
The Power Readings screen provides power consumption estimates for the enclosure. This screen includes the following fields:
NOTE: Power readings are shown only if the enclosure has a non-power-aware blade present. This
is a feature of HP BladeSystem bc2x00 Blade PCs only.
The screen may differ from the image shown here.
ENWW Enclosure Tab 27
Page 38
Enclosure Average Supply Input Power—The immediate average power consumption averaged
over the last 5 second sample interval.
Enclosure Average Supply Input Power 24-Hour Sample Intervals—This is a rolling average
of power consumption over the course of preceding last 24 hours of uptime.
Enclosure Peak Supply Input Power 24-Hour Sample Intervals—This is the peak of power
consumption over the course of the preceding 24 hours of uptime.
Enclosure Average Supply Input Power Time Averaged Since Powered—This is the power
consumption averaged over the total uptime for the IA. This is since the previous power cycle or IA reset.
Enclosure Peak Supply Input Power Time Averaged Since Powered—This is the peak of power
consumption over the total uptime for the IA. This is since the previous power cycle or IA reset.
NOTE: All statistics are calculated from the time of the last reboot, up to 24-Hours.

Virtual Buttons

NOTE: Only enclosure administrators can execute these commands.
The Virtual Buttons screen (shown below) enables an enclosure administrator to modify the power state of the enclosure and Unit Identification LED from a remote location to facilitate troubleshooting by technicians in the data center.
28 Chapter 4 Web Browser Interface ENWW
Page 39
The Toggle On/Toggle Off button remotely changes the state of the enclosure Unit Identification LED. The illustration below shows the information presented in the Enclosure Power area of the Virtual Buttons screen:
You can select the appropriate function with the following buttons:
Restart Integrated Administrator—Restarts the Integrated Administrator and does not affect the
blade PCs.
Power Off Enclosure—Attempts a graceful shutdown of the system for 5 minutes, after which time
this command powers down all components of the enclosure immediately.
CAUTION: HP recommends that you use the operating system shutdown procedures before
powering down a blade PC or enclosure. After the enclosure is powered off, powering on can only occur by local access to the system.

System Log

The System Log screen (shown below) provides an enclosure administrator with a chronological list of events and updates associated with the enclosure.
Two buttons appear at the bottom of this screen:
Refresh—Refreshes the screen.
Clear—Clears the system log.
ENWW Enclosure Tab 29
Page 40

System Log Policy

The System Log Policy screen (shown below) provides an enclosure administrator with display and control over the logging of some system logged event messages.
There are two radio buttons for each event severity classification corresponding to enclosure and bay system log policies:
Critical—ON / OFF
NOTE: Enclosure and bay critical syslog messages cannot be masked.
Major—ON / OFF
Minor—ON / OFF
Normal—ON / OFF
Informational—ON / OFF
All enclosure and bay system log policies are defaulted to ON.
For details concerning specific system log messages, see system log messages and severity classification.
Error Messages on page 122 for supported
30 Chapter 4 Web Browser Interface ENWW
Page 41

Bays Tab

The Bays tab provides access to the following screens:

Bay List

Bay Information
Remote Console
Virtual Buttons
Console Log
Bay Power Consumption
Bay List
The Bay List screen (shown below) enables an enclosure administrator to observe and update the assignment of groups to blade PC bays, as well as monitor the status of each blade PC installed in the enclosure.
Group administrators and group members with permissions can view the blade PC bays assigned to their groups.
The following table describes the information presented in the Bay List screen:
ENWW Bays Tab 31
Page 42
Table 4-12 Bay List Field Descriptions
Field Possible Values Description
Bay # 1-20 Blade PC number.
UID Displays a blue circle if the unit
Blade PC Name Name of the blade PC in that blade PC
Assigned to Group Name of the group that owns that bay.
Status OK, Degraded, or Failed The status and power state of the blade
identification (UID) LED of the blade is lit.
bay as defined by the operating system of the blade PC.
NOTE: The blade PC health service
must be installed for the Integrated Administrator to obtain the blade PC name and operating system type.
PC.
The following table lists permissions that are related to the action buttons of the Bay List screen
Table 4-13 Bay List Action Buttons and Permissions
Field Possible Values Description
View/Modify Opens the Blade Information screen. Enclosure administrators, group
administrators, and group members with permissions.
Remote Console Opens the Remote Console screen. Enclosure administrators, and group
administrators with permissions.
Console Log Opens the Console Log screen. Enclosure administrators, group
View Group Opens the View/Modify Group screen. Enclosure administrators only.
Bay Assignment Opens the Bay Assignment dialog box.

Bay Information

NOTE: Be sure the Integrated Administrator displays up-to-date blade PC information by rebooting
the blade PC after installing the blade PC health service. The blade PC may need to be rebooted a second time to fully update the Integrated Administrator.
The Bay Information screen (shown below) enables an enclosure administrator to observe the status and general information for a blade PC in a given blade PC bay. Group administrators and group members with View rights to the blade PC bay can also observe this information.
administrators, and group members with permissions.
Enclosure administrators only.
NOTE: If a blade PC is to be re-
assigned, it must be unassigned first.
32 Chapter 4 Web Browser Interface ENWW
Page 43
To be sure that the Bay Information screen displays the optimal number of possible values, you must have the blade PC health driver installed.
The following table describes the information presented on the Bay Information screen for all enclosure administrators and for group members and groups with rights to the blade PC bay.
Table 4-14 Bay Information Field Descriptions—Status Area
Field Possible Values Description
Status Area
Bay Number
Blade PC Name Name of blade PC as specified with the
Status OK, Degraded, or Failed Status of the blade PC.
Bay number.
blade PC operating system.
NOTE: In the case of a failed or
degraded BC2x00 blade, an additional
diagnostic message is posted in
parentheses.
ENWW Bays Tab 33
Page 44
Table 4-14 Bay Information Field Descriptions—Status Area (continued)
Thermal Condition OK, Warm, Caution, or Critical Thermal condition of the blade.
NOTE: In the case of a thermal critical
or caution condition, BC2x00 blades provide thermal measurements for the CPU, Graphics processor, and ambient sensors in degrees Celsius at the time of failure detection.
Enclosure Name Name of enclosure.
For the default enclosure name, see
Factory Default Settings on page 138.
Table 4-15 Bay Information Field Descriptions—General Area
Field Possible Values Description
General Area
Blade PC Type
Blade PC Installed OS Operating system installed on the blade
Spare Number Spare number of the blade PC.
Serial Number Serial number of the blade PC.
Asset Tag Asset tag number of the blade PC.
BIOS Version mm/dd/yy ROM version on the blade PC.
CPU # Type Type of processor on the blade PC.
CPU # Max Speed Speed associated with the blade PC
Installed RAM Amount of memory installed on the blade
NIC #1 and #2 MAC Addresses ##:##:##:##:##:##, where ## ranges
BMC Revision 00 to FF BMC Revision: For BC2x00 blades, the
Product name of the blade PC.
PC.
processor.
PC.
MAC address of the NIC 1 interface and
from 00 to FF.
the NIC 2 interface.
Blade Management Controller (BMC) revision will be posted here. The BMC versions prior to version 23 do not report this value. N/A will be shown in parentheses. Future versions of the BMC will provide this information.

Remote Console

Enclosure administrators and group administrators with access to the bay can click Remote Console to open a remote text-based console (shown below) to the blade PC in the bay.
NOTE: Click on the command windows to assure it has focus, otherwise no commands can be entered.
34 Chapter 4 Web Browser Interface ENWW
Page 45
For information on establishing remote console connectivity, see Enabling Remote Console Sessions
to Blade PCs on page 82.

Virtual Buttons

Enclosure administrators and group administrators with permissions can use the Virtual Buttons screen (shown below) to modify the state of the power state and Unit Identification LED of a blade PC in order to facilitate troubleshooting from a remote location.
ENWW Bays Tab 35
Page 46
The Virtual Buttons screen enables group administrators and enclosure administrators to reboot, power off, or identify the blade PC with the following items:
The Toggle On/Off button remotely changes the state of the blade PC Unit Identification LED.
You can select the appropriate function in the Blade PC Power area using the following radio
buttons:
Reboot reboots the blade PC.
Power Off attempts a graceful shutdown of the blade PC for 5 minutes, after which time this
command powers down the blade PC immediately. This is the equivalent to a less than 3­second power button press on a standard desktop PC.
Power Off Immediately powers off the blade PC forcefully. This is the equivalent to a 5-
second power button press on a standard desktop PC.
CAUTION: Without service, an ACPI-compliant operating system, the Integrated Administrator cannot
gracefully shut down a blade PC. This condition can result in the permanent loss of data.
NOTE: Click Apply for these settings to take effect.
Whenever possible, HP recommends that you use the operating system shutdown procedures before powering down a blade PC or enclosure. Once the enclosure is powered off, powering on can only occur with local access to the system.
36 Chapter 4 Web Browser Interface ENWW
Page 47

Console Log

NOTE: Only group members, group administrators, and enclosure administrators can view a console
log of a blade PC.
The Console Log screen displays the console log for the specified bay. The console log of the bay is not stored between reboots of the Integrated Administrator, so the information will only include what has taken place since the last power on of the Integrated Administrator.
The data captured in the console log is all output from the serial console of the blade PC that occurred while no one was connected to the console. For security reasons, console output during a user connection session is not logged.
The Refresh button refreshes the console log for the current blade PC.

Bay Power Consumption

The Bay Power Consumption screen (shown below) enables an enclosure administrator to observe the power consumption of all populated bays within the enclosure.
The table reports the following information:
Bay #
Bay Type—This is necessary to know this since only BC2x00 blades are power-aware and report
power to the IA.
Wdc—This is direct current (DC) power consumption in Watts of the blade averaged over the last
1 second sampling interval.
ENWW Bays Tab 37
Page 48
Wdc (24hr Avg.)—This is direct current (DC) power consumption in Watts of the blade averaged
over the last 24 hours of operation within the enclosure.
Wdc (Overall Avg.)—This is direct current (DC) power consumption in Watts of the blade averaged
over the last 24 hours of operation within the enclosure.
NOTE: Power reporting is a feature limited to BC2x00 series of blades. All others will not report a value
in the any of wattage columns.
All statistics are calculated from the time of the last reboot, up to 24-Hours.
38 Chapter 4 Web Browser Interface ENWW
Page 49

Administration Tab

For an explanation of user rights associated with the Integrated Administrator, see Enabling Remote
Console Sessions to Blade PCs on page 82.
The Administration tab provides access to the following screens:

User List

Group List
Add User
Add Group
View/Modify User
View/Modify Group
User List
The User List screen (shown below) enables an appropriate group administrator or enclosure administrator to observe and update user access to groups and blade PC bays.
The following table lists the permissions related to the action buttons of the User List screen.
Table 4-16 User List Action Buttons and Permissions
Button Function Permissions
View/Modify User Opens the View/Modify User screen. Enclosure administrators can access
and modify the information for any user.
Users can access and modify the
information for own account.
Remove User Removes the selected user (unless the
account is your own).
Only enclosure administrators can
execute this command.
The following table describes the information presented in the User List screen.
Table 4-17 User List Field Descriptions
Button Function Permissions
ENWW Administration Tab 39
Page 50
Table 4-17 User List Field Descriptions (continued)
User Name User login name.
Full Name User full name.
Account Type Administrator or User Shows if the user is an enclosure
administrator.
Account Status Enabled or Disabled Shows if the user’s account is enabled.
Group Membership Shows the groups in which the user has

Group List

The Group List screen (shown below) enables an enclosure administrator to observe and update the assignment of groups and users to blade PC bays.
membership.
Two buttons appear on this screen:
View/Modify Group—Opens the View/Modify Group screen.
Remove Group—Removes the selected group.
NOTE: Enclosure administrators can view and modify the information for all groups. Group
administrators and group members can view the information for the groups in which they are members.
Table 4-18 Group List Field Descriptions
Field Description
Group Name Group name
40 Chapter 4 Web Browser Interface ENWW
Page 51
Table 4-18 Group List Field Descriptions (continued)
Assigned Bays Blade PC bays that the group owns
Group Members Users with membership in the group

Add User

NOTE: Only enclosure administrators have access to this area of the Integrated Administrator.
The Add User screen (shown below) enables an enclosure administrator to create a user profile, including group and blade PC bays assignments.
Two buttons appear on this screen:
Apply—Saves changes made to this screen.
Cancel—Restores all fields on this screen to their original values.
The following table describes the fields /of the Add User screen.
Table 4-19 Add User Field Descriptions
Field Possible Values Description
User Name 1-13 characters including alphanumeric,
dash, and underscore characters.
Login name of the user.
ENWW Administration Tab 41
Page 52
Table 4-19 Add User Field Descriptions (continued)
The user name must begin with a letter. A maximum of 25 users can be created in addition to the reserve accounts.
NOTE: “Administrator,” switch,”
switcha, ”switchb,” “SAM,” and “all” are reserved names and cannot be used. This restriction is not case-sensitive.
Password 3-8 characters including all printable
characters
Confirm Password 3-8 characters including all printable
characters
Account Type Radio buttons (Administrator and User) Determines if the user has enclosure
Account Status Radio buttons (Enabled and Disabled) Determines if the user’s account is
Full Name (optional) 1-20 characters
Accepts only alphanumeric, dash, underscore, and space characters
Contact Information (optional) 1-20 characters
Accepts only alphanumeric, dash, underscore, and space characters
Group Names All groups are listed A list of all possible groups.
Group Membership x number of groups (all groups in which
the user has membership)
Add User [View]>>> Adds the user to the selected groups in
User’s password.
User’s password.
administrator rights.
enabled.
Full name of user.
Optional user contact information.
A list of all groups of which the user is a member.
the Group Names text box with View rights for group members
Add User [View/Modify]>>> Adds the user to the selected groups in
<<< Removes the user from the selected

Add Group

NOTE: Only enclosure administrators have access to this area of the Integrated Administrator.
The Add Group screen (shown below) enables an enclosure administrator to create a group profile, including user and blade PC bays assignments.
These groups appear in the Group Membership text box. The user loses View/Modify rights if they previously had them.
the Group Names text box with View/ Modify rights for group administrators or view rights for group members.
groups in the Group Membership text box.
42 Chapter 4 Web Browser Interface ENWW
Page 53
NOTE: Grayed-out check boxes are unavailable because they are already assigned to another group.
Two buttons appear on this screen:
Apply—Saves changes made to this screen.
Cancel—Restores all fields on this screen to their original values.
Table 4-20 Add Group Field Descriptions—Group Information Area
Field Possible Values Description
Group Information Area
Group Name
Group Description (optional) 1-20 characters
1-13 characters including alphanumeric, dash, and underscore characters.
The group name must begin with a letter. A maximum of 20 users can be created.
Accepts only alphanumeric, dash, and underscore characters.
Name of group.
Description of group.
Table 4-21 Add Group Field Descriptions—Bay Assignment Area
Field Possible Values Description
Bay Assignment Area
ENWW Administration Tab 43
Page 54
Table 4-21 Add Group Field Descriptions—Bay Assignment Area (continued)
Bay 1 - Bay 20 Determines which bays the group owns.
Only one group can own a particular bay. If a check box is disabled, another group already owns the bay.
Select All Selects all check boxes of the bays.
Clear All Clears all check boxes of the bays.
Table 4-22 Add Group Field Descriptions—Group Membership Area
Field Possible Values Description
Group Membership Area
User Names
Group Members x number of users (all users that are
Add User [View]>>> Adds selected users in the User Names
Add User [View/Modify]>>> Adds selected users in the User Names
<<<Remove User Removes selected users in the Group

View/Modify User

You can access the View/Modify User screen by clicking any row in the User List and then clicking View/ Modify User. The View/Modify User screen provides the same functions and has the same access as the Add User screen. See the “Add User” section in this chapter.
All users and enclosure administrators are listed.
members of the group).
A list of all possible users.
A list of all users that are members of the group.
text box to the group with View rights for group members.
Users lose View/Modify rights for group administrators if they previously had them.
text box to the group with View/Modify rights for group administrators.
Members text box from the group.

View/Modify Group

You can access the View/Modify Group screen by clicking any row in the Group List and then clicking View/Modify Group. The View/Modify Group screen the provides same functions and has the same access as the Add Group screen. See
44 Chapter 4 Web Browser Interface ENWW
Add Group on page 42 in this chapter.
Page 55

Event List Tab

The Event List tab provides access to the following screens:
Event List
Event Log Policy
The Event List differs from the System Log in the following ways:
Any user can view the Event List. Only enclosure administrators can access the System Log.
The messages in the Event List are limited to cautions and critical failures. Refer to the enclosure
System Log for information on both failures and fixes.
The Event List only displays messages received since the user logged into the Integrated
Administrator. The System Log displays every message generated by the enclosure diagnostics.
The Event List screen (shown below) provides the following information for each event:
Severity
Source
Date
Time
Event Details (the example below indicates a fan failure)
The Integrated Administrator provides real-time event notifications for an enclosure according to two categories of severity (caution and critical) described in the following table. For detailed information
ENWW Event List Tab 45
Page 56
regarding the Event List, including a comprehensive list of event messages, see Event Icons and
Details on page 136.
Table 4-23 Event Notification Icons
Icon Description

Event Log Policy

Caution—An event that does not prevent the enclosure from operating, maintaining power, or serving its user community
When a caution event occurs, a reasonable guarantee that operability can persist no longer exists.
Critical—An event that prevents the continued operation of the enclosure.
When a critical event occurs, the inoperability of the enclosure is imminent.
Critical—ON / OFF
Major—ON / OFF
Minor—ON / OFF
Normal—ON / OFF
Informational—ON / OFF
The default is ON for all Enclosure event log policies. The default is ON for all Bay event log policies except Normal and Informational.
46 Chapter 4 Web Browser Interface ENWW
Page 57
For details concerning specific event log messages, see Error Messages on page 122 for supported event log messages and severity classification.

Interconnect Tab

The Interconnect Tray screen (shown below) allows anyone to view information about the interconnect tray. It allows enclosure administrators to connect to the remote console of one of the interconnect switches if installed.
The following table describes the information displayed in the areas that comprise the Interconnect Tray screen.
Table 4-24 Interconnect Tray Screen Field Descriptions—Interconnect Tray Information Area
Field Possible Values Description
Interconnect Tray Information Area
Status
Temperature OK, Warm, Caution, or Critical Thermal status of the interconnect tray.
Switch A Status OK, Degraded, or Failed Status of Switch A. This will only be
Switch B Status* OK, Degraded, or Failed Status of Switch B. This will only be
OK, Degraded, or Failed Status of the interconnect tray.
displayed if an interconnect switch is
installed.
displayed if an interconnect switch is
installed.
ENWW Interconnect Tab 47
Page 58
Table 4-24 Interconnect Tray Screen Field Descriptions—Interconnect Tray Information Area (continued)
Manufacturer Manufacturer of the interconnect tray.
Product Name Product name of the interconnect tray.
Interconnect Tray Part Number Spare part number of the interconnect
tray.
Interconnect Tray Serial Number Serial number of the interconnect tray.
* Proliant C-GbE e-Class switch only.
Table 4-25 Interconnect Tray Screen Field—Switch Terminal Console Area (only present if an interconnect
switch is installed)
Field Possible Values Description
Switch Terminal Console Area (only present if an interconnect switch is installed)
Switch A button
Switch B button* Opens a new window to the remote
* Proliant C-GbE e-Class switch only.
Opens a new window to the remote
console of switch A.
console of switch B.
48 Chapter 4 Web Browser Interface ENWW
Page 59

5 Command Line Interface

This chapter provides reference material for operating the Integrated Administrator Command Line Interface (CLI). This chapter provides command line related information with the following sections:
Accessing the Command Line Interface
Operating the Command Line Interface
General commands
General management commands
User account commands
Enclosure network configuration commands
Enclosure management commands
Blade PC management commands
Functionality exclusive to the command line interface
For a detailed explanation of the command line conventions used in this document, see
Line Conventions on page 121.
For easy reference, the index of this book also provides a comprehensive listing of the commands supported by the Integrated Administrator.
Command
ENWW 49
Page 60

Accessing the Command Line Interface

You can access the CLI remotely through the management (10/100 Ethernet) connector, locally through the console (serial) connector on the rear panel of the enclosure, or through any uplink depending on VLAN configuration.

Accessing Remotely through the Management Connector

To access the Integrated Administrator command line interface remotely through the management (10/100 Ethernet) connector:
1. Get the default host name from the settings tag attached to the interconnect tray.
2. Open a Telnet or Secure Shell application and type the IP address or DNS name for the enclosure
you wish to access.
CAUTION: Using Telnet instead of Secure Shell means your remote session, including
password, appears in clear text on that network.
3. Type the user name and password into the Login prompt.

Accessing Locally through the Console Connector

To access the Integrated Administrator locally through the serial connector:
1. Connect a local client device, such as a laptop computer, to the serial connector using a null-modem
cable.
NOTE: Client devices must satisfy the requirements provided in Requirements for Local Client
Devices on page 11.
2. Open the terminal emulator and press Enter one or more times to get the login prompt.
3. Type the user name and password.
50 Chapter 5 Command Line Interface ENWW
Page 61

Operating the Command Line Interface

General Commands

The following table describes the information displayed in the areas that comprise the Enclosure Information screen.
Table 5-1 General Commands
Command Description Restrictions
CLEAR SCREEN Clears the terminal screen None
EXIT Exits the command line interpreter None
HELP {<ommand>} |Tree If a command is given, the usage and help text for the
LOGOUT Exits the command line interpreter None
QUIT Exits the command line interpreter
SLEEP Pauses the sessions for a fixed period of time. Useful for
command are shown in a tree format. If no argument is given, all base commands are displayed.
adding delays to scripts. The <seconds> field can be any whole number from 1 - to 86400. Once the pause has started, no way exists to continue the session before time runs out, but you can terminate the session and start another one.

General Management Commands

The following table describes the information displayed in the areas that comprise the Enclosure Information screen.
Table 5-2 General Management Commands
Command Description Restrictions
CLEAR SSESSION SWITCH [A | B]
Terminate a Terminal session from the enclosure.
This is not a graceful termination. The connected user loses any unsaved work.
None
None
Group administrators may only execute thus command for the blade PC bays to which they have access.
CLEAR SSHKEY Remove the contents of the Secure Shell authorized keys file.
After performing this command, you will not be able to login using the public key-based authentication.
CONNECT SWITCH [A | B] Opens a remote console connection to switch A or B.
A single switch cannot support multiple, simultaneous remote console sessions.
DOWNLOAD CERTIFICATE
<url>
Download a CA supplied PKCS#7 file to replace the current security certificate on the system.
Supported protocols are http, ftp, and tftp. Format the URL as protocol://host/path/file.
If your ftp server does not support anonymous connections, you can specify a username and password by augmenting the host part in the above format with username:password@host.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
ENWW Operating the Command Line Interface 51
Page 62
Table 5-2 General Management Commands (continued)
DOWNLOAD SSHKEY Downloads an authorized key file to use with Secure Shell v2,
which can contain the public keys for any enclosure administrator. Supported protocols are http, ftp, and tftp. Format the URL as protocol://host/path/file. If your ftp server does not support anonymous connections, you can specify a username and password by replacing the host part in the previous format with username:password@host.
Only enclosure administrators may execute this command.
GENERATE CERTIFICATE REQUEST
GENERATE CERTIFICATE SELFSIGNED
PING
{<number>}
{<IP address>} | <server name>}
SET DISPLAY EVENTS
[ ON | OFF | ENCLOSURE | BAY]*
SET EXPERT {MODE}
[ ON | OFF ]
SET FACTORY Sets the Integrated Administrator back to its factory defaults.
Generates a PKCS#10 certificate request. Only enclosure administrators
Generates a self-signed certificate. Only enclosure administrators
Sends ICMP echo messages to a remote IP device.
If <number> is omitted, only 5 packets are sent. Packets are sent out at 1-second intervals.
Turns event notification on or off. The Integrated Administrator preservers this setting across all logins only for the global ON/ OFF.
Turns EXPERT MODE on or off. When EXPERT MODE is on, the system will not prompt the user to confirm actions. Users should exercise caution when working in EXPERT MODE as many actions are not reversible.
The Administrator account password does not change. The Integrated Administrator is restarted after all the changes are made.
Note: This command removes all groups, users, and other customization from the memory of the enclosure, and the information is unrecoverable.
may execute this command.
may execute this command.
The <IP address> must be in the form “###.###.###.###” where ### ranges from 0 to
255.
None
None
Only the “Administrator” account may execute this account.
SET SCRIPT MODE
[ ON | OFF ]
SHOW SESSIONS Displays the connection to each bay and switch if one exists.
SHOW SSHFINGER PRINT Displays the key fingerprint of the host SSH pubic key of the
SHOW SSHKEY Displays the contents of the existing Secure Shell authorized
When SCRIPT MODE is ON, the following commands require a password argument: ADD USER <user name> <password>, SET USER <user name> <password>, and SET PASSWORD <password>. When SCRIPT MODE is OFF, the following commands do not require a password argument: ADD USER, SET USER PASSWORD, and SET PASSWORD.
Default values require user interaction.
Only one user may connect to each bay and switch at a time. It also shows each user that is currently logged in, the user’s port number, connect time, and remote system name.
Integrated Administrator. This can be used from the serial console to validate the identity of the Integrated Administrator before initializing an SSH connection across a network.
keys file that is being used for enclosure administrator key­based authentication.
None
Users may not run this command. Group members and group administrators may only see the sessions for bays assigned to groups to which they belong. Enclosure administrators see all sessions
None
Only enclosure administrators may execute this command.
52 Chapter 5 Command Line Interface ENWW
Page 63
Table 5-2 General Management Commands (continued)
SHOW ENCLOSURE POWER
* For event display severity policy-specific settings, these are session-specific only and were added to provide granular control over a specific classification of event severity types.
SET DISPLAY EVENTS ENCLOSURE
SET DISPLAY EVENTS ENCLOSURE ALL [ ON | OFF ]
SET DISPLAY EVENTS ENCLOSURE CRITICAL [ ON | OFF ]
SET DISPLAY EVENTS ENCLOSURE INFORMATIONAL [ ON | OFF ]
SET DISPLAY EVENTS ENCLOSURE MAJOR [ ON | OFF ]
Display power consumption estimates for the enclosure, including all sub-components. This information includes overall power consumption of the enclosure, as well as peak power and time averaged power across a 24-hr-and-since powered / reset interval.
This command provides only estimated power usage based on measurements reported from power-aware blades and estimates from enclosure subsystem components. Use it only as reference information.
NOTE: This is only displayed
when all blades are power­aware (e.g., bc2x00) only. A note is displayed indicating that the enclosure cannot accurately estimate power consumption.
SET DISPLAY EVENTS ENCLOSURE MINOR [ ON | OFF ]
SET DISPLAY EVENTS ENCLOSURE NORMAL [ ON | OFF ]
SET DISPLAY EVENTS BAY
SET DISPLAY EVENTS BAY ALL [ ON | OFF ]
SET DISPLAY EVENTS BAY CRITICAL [ ON | OFF ]
SET DISPLAY EVENTS BAY INFORMATIONAL [ ON | OFF ]
SET DISPLAY EVENTS BAY MAJOR [ ON | OFF ]
SET DISPLAY EVENTS BAY MINOR [ ON | OFF ]
SET DISPLAY EVENTS BAY NORMAL [ ON | OFF ]
For details concerning event classification see

User Account Commands

Table 5-3 User Account Commands
Command Description Restrictions
ADD GROUP
<group name>
Adds a group to the system
The default group description is blank.
Event Icons and Details on page 136.
Only enclosure administrators may execute this command. A maximum of 20 groups may be added to the system.
The <group name> must be unique to all other group names and user names and is case-sensitive. It must be 1-13 characters long and can
ENWW Operating the Command Line Interface 53
Page 64
Table 5-3 User Account Commands (continued)
include alphanumeric, dash, and underscore characters. It must begin with a letter.
NOTE: “Administrator,”
switch,” switcha, ”switchb,” “SAM,” and “all” are reserved names and cannot be used. This restriction is not case­sensitive.
See
Factory Default Settings on page 138 for factory
default groups accounts.
ADD USER
<user name>
{<password>}
Adds a user to the system
If a password is not given, the user is prompted for one. If SCRIPT MODE is enabled, the password is not optional and must be provided.
Only enclosure administrators may execute this command. A maximum of 25 users may be added in addition to the reserved accounts.
The <user name> must be unique to all other group names and user names and is case-sensitive. It must be 1-13 characters long and can include alphanumeric, dash, and underscore characters. It must begin with a letter.
The <password> must be 3-8 characters long and includes all printable characters. If a password is not entered, the user is prompted for one.
NOTE: “Administrator,”
switch,” switcha, ”switchb,” “SAM,” and “all” are reserved names and cannot be used. This restriction is not case­sensitive.
See
Factory Default Settings on page 138 for factory
default user accounts.
ASSIGN ADMINSTRA- TOR (RIGHTS)
<user name>
ASSIGN BAY
[ALL | <bay number> {[ , | - ] <bay number>}] <group name>
ASSIGNS USER
<user name>
<group name>
{[VIEW | MODIFY]}
Promotes a user to have enclosure administrator permissions.
Group membership is not detected in case of enclosure administrator rights are removed at a later time.
Assigns one or more bays to a group.
If a bay is already assigned to a group, it must first be unassigned before executing this command.
Assigns a user to a group with View rights (for group members) or View/Modify rights (for group administrators)
If View or View/Modify is not specified, View is chosen by default.
Only enclosure administrators may execute this command.
The <user name> is case­sensitive.
Only enclosure administrators may execute this command.
The <group name> is case­sensitive.
Only enclosure administrators may execute this command.
The <user name> is case­sensitive.
54 Chapter 5 Command Line Interface ENWW
Page 65
Table 5-3 User Account Commands (continued)
DISABLE USER
<user name>
Disables a user account.
The user is immediately logged out of the system and prevented from log in until the account us enabled.
Only enclosure administrators may execute this command.
The <user name> is case­sensitive. The administrator account cannot be disabled.
ENABLE USER
<user name>
REMOVE GROUP
[ ALL | <group name> ]
REMOVE USER
[ALL | <user name>]
Enables a user account that was previously disabled by the DISABLE USER command
Removes a group and automatically unassigns all bays within the group.
Removes a user from the system.
If ALL is specified, the command is run for all users except the default system accounts.
Only enclosure administrators may execute this command.
The <user name> is case­sensitive.
NOTE: The default ‘SAM’
administrator account is disabled by default. This was provided for HP Session Allocation Manager (SAM) support. It is highly recommended that the SAM account password be changed either before or immediately after enabling, as all Integrated Administrators will have the same default SAM account password of SamUser123.
Only enclosure administrators may execute this command.
The <group name> is case­sensitive.
Only enclosure administrators may execute this command.
The <user name> is case­sensitive.
SET GROUP {DESCRIPTION} <group name> <description>
SET PASSWORD
{<password>}
NOTE: Administrator,
“switch”, “SAM”, “switcha,” and “switchb,” cannot be removed.
Sets a group’s description. Only enclosure administrators
may execute this command. The <description> must be 1-20 characters long and can include alphanumeric, dash, and underscore characters. The default group description is blank. If spaces are part of the contact information, enclose the information in quotes.
Sets the password of the user currently logged into the Integrated Administrator. If a password is not given on the command line, the user is prompted for one.
NOTE: This command is not valid in SCRIPT MODE if
password is not specified.
The <password> must be 3-8 characters long and can include all printable characters.
ENWW Operating the Command Line Interface 55
Page 66
Table 5-3 User Account Commands (continued)
SET USER CONTACT
{<user name>} <contact info>
If no <user name> exists, the command modifies the contact info of the user that executed the command.
Only enclosure administrators may modify another user’s contact information.
The <user name> is case­sensitive. The <contact info> must be 1-20 characters long and can include alphanumeric, dash, underscore, and space characters. The default contact information is blank. If spaces are part of the contact information, enclose the information in quotes.
SET USER FULL NAME
{<user name>} <full name>
SET USER PASSWORD
<user name>
Sets a user’s full name.
If no <user name> exists, the command modifies the full name of the user that is currently logged in.
Sets a user’s password.
If you do not supply a password on the command line, you are prompted for one.
NOTE: This command is not valid in SCRIPT MODE if
password is not specified.
Only enclosure administrators may modify another user’s full name.
The <user name> is case­sensitive. The <contact info> must be 1-20 characters long and can include alphanumeric, dash, underscore, and space characters. The default full name is blank. If spaces are part of this information, enclose the information in quotes.
Only enclosure administrators may modify another user’s password. Only the Administrator account may modify the password of the Administrator account.
The <user name> is case­sensitive. The <new password> must be 3-8 characters long and can include all printable characters.
SHOW GROUP
[<group name> | ALL]
SHOW USER
[<user name> | ALL]
Displays the group’s description, a list of members with View permission, a list of members with View/Modify permission, number of bays, and a list of each of the bay the group manages.
Displays the user’s full name, contact, whether the user has administrator rights, whether the account is enabled, and the groups for which the user has View or View/Modify permissions.
If ALL is entered, this information is given for every user and an asterisk before the user name denotes the current user.
Group members and group administrators only see the groups in which they have membership. Users may not execute this command.
The <group name> is case­sensitive.
If spaces are part of this information, enclose the information in quotes.
Only enclosure administrators may view another user’s information.
The <user name> is case­sensitive. Users who do not have enclosure administrator
56 Chapter 5 Command Line Interface ENWW
Page 67
Table 5-3 User Account Commands (continued)
permissions only see their user information.
UNASSIGN ADMINSTRA­TOR (RIGHTS)
<user name>
UNASSIGN USER
<user name> <group name>
Takes enclosure administrator rights from a user. Only enclosure administrators
Removes the user from the specified group. Only enclosure administrators

Enclosure Network Configuration Commands

Table 5-4
Command Description Restrictions
ADD SNMP TRAPRECEIVER
<ip address>
DISABLE SECURESH Disables Secure Shell account to the Integrated Administrator. Only enclosure
Adds an IP address to receive SNMP traps.
Only v1 traps are supported. Traps are directed to the SNMP default port of 162.
may execute this command. The Administrator account cannot have enclosure administrator rights taken away.
The <user name> is case­sensitive.
may execute this command.
The <user name> and <group name> are case-sensitive.
Only enclosure administrator may execute this command.
administrators may execute this command.
DISABLE SNMP Disables SNMP support for the Integrated Administrator.
Does not clear the SNMP trap receivers that have been configured. SNMP trap receivers can still be added and removed. If SNMP is disabled, Systems Insight Manage agents do not work properly.
DISABLE TELNET Disables Telnet access to the Integrated Administrator. Only enclosure
DISABLE WEB Disables HTTP and HTTPS access to the Integrated
Administrator.
This command prevents access to the Web-based user interface.
DOWNLOAD CONFIG
<url>
ENABLE SECURESH Enables Secure Shell account to the Integrated Administrator. Only enclosure
ENABLE SOAP Enables SOAP support for the Integrated Administrator for all
The files are auto-executed in script mode. The file is not allowed to change the password of the Administrator account. Supported protocols are http, ftp, and tftp. Format the URL as protocol://host/path/file. If your ftp server does not support anonymous connections, you can specify a user name and password by replacing the host part in the previous format with username:password@host.
administrator accounts.
Only enclosure administrators may execute this command.
administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
The IP address must be in the form ###.###.###.### where ### ranges from 0 to 255.
administrators may execute this command.
This does not affect the built­in SAM user account. See
ENWW Operating the Command Line Interface 57
Page 68
(continued)
Event Icons and Details on page 136 for supported
SOAP commands.
DISABLE SOAP Disables SOAP support for the Integrated Administrator for all
administrator accounts.
ENABLE SNMP Enables SNMP support for the Integrated Administrator. Only enclosure
ENABLE TELNET Enables Telnet access to the Integrated Administrator. Only enclosure
ENABLE WEB Enables HTTP and HTTPS access to the Integrated
REMOVE SNMP TRAPRECEIVER
<ip address>
SET DNS
<primary address> {<secondary address>}
Administrator.
Removes an IP address from the list of systems to receive SNMP traps
Sets the primary and secondary DNS server addresses
These servers are only used if the system is currently configured to use a static IP address.
This does not affect the built­in SAM user account. See
Event Icons and Details on page 136 for supported
SOAP commands.
administrators may execute this command.
administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
The IP address must be in the form ###.###.###.### where ### ranges from 0 to 255.
Only enclosure administrators may execute this command.
The IP address must be in the form ###.###.###.### where ### ranges from 0 to 255.
SET GATEWAY
<ip address>
SET IPCONFIG
[DHCP {DYNAMICDNS} | STATIC <P address> <netmask>]
SET SNMP COMMUNITY
[READ | WRITE] <community name>
Sets the network default gateway
This gateway is only used if the system is configured to use a static IP address.
Sets up the Integrated Administrator IP configuration
The gateway and DNS addresses are cleared. The optional DYNAMICDNS argument enables Dynamic DNS.
Sets the community name for the read or write SNMP community
The default names for the read and write community are public and blank, respectively. If a blank write community name is given, SNMP set commands are disabled until a non­empty community name is given.
Only enclosure administrators may execute this command.
The IP address must be in the form ###.###.###.### where ### ranges from 0 to 255.
Only enclosure administrators may execute this command.
The IP address must be in the form ###.###.###.### where ### ranges from 0 to 255.
Only enclosure administrators may modify another user’s contact information.
The write <community name> must be 1-20 characters long, and the read <community name> must be 1-20 characters long. Both can include alphanumeric, dash, and underscore characters. The default read community
58 Chapter 5 Command Line Interface ENWW
Page 69
(continued)
name is public. The default write community name is blank.
SET SNMP CONTACT
<contact>
SET SNMP LOCATION
<location>
SHOW NETWORK Displays the DHCP state, Dynamic DNS state, IP address,
SHOW SNMP Displays the SNMP system name, location, and contact, read
Configures the name of the system contact. Only enclosure
Configures the SNMP location of the enclosure.
The default location is blank.
subnet mask, gateway address, primary and secondary DNS addresses, HTTP and HTTPS server status, SNMP status, Secure Shell status, and Telnet status of the enclosure.
community name, write community name, and a list of the trap destinations.
administrators may execute this command.
The <contact> must be 1-20 characters long and can include alphanumeric, dash, underscore, and space characters. If spaces are part of this information, enclose the information in quotes.
Only enclosure administrators may execute this command.
The <location> must be 1-20 characters long and can include alphanumeric, dash, underscore, and space characters. If spaces are part of this information, enclose the information in quotes.
None
Only enclosure administrators may execute this command.

Enclosure Management Commands

Table 5-5
Command Description Restrictions
CLEAR SYSLOG ENCLOSURE
SET SYSLOG POLICY [ENCLOSURE | BAY ]*
POWEROFF ENCLOSURE
{FORCE}
RESTART Restarts the Integrated Administrator. This does not affect
Clears the enclosure system log. Only enclosure administrators
This command turns system log message posting on or off per severity type. The Integrated Administrator preservers this setting across all logins/users
Performs a graceful shutdown of the enclosure. Each blade is first gracefully shut down. If the FORCE argument is given, the enclosure and all blades are immediately shutdown.
operation of bays in the system.
may execute this command. Once deleted, this information cannot be restored.
None
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
ENWW Operating the Command Line Interface 59
Page 70
(continued)
SET DATE
MMDDhhmm
{{CC}YY} {TZ}
Sets the date of the enclosure with the following definitions:
MM: month
DD: day
hh: hour (24-hour format)
mm: minute
CC: century
YY: year
TZ: time zone (case-sensitive)
If the time zone is left blank, the current time is left in effect.
Only enclosure administrators may execute this command.
MM is an integer from
1-12
DD is an integer from
1-31
hh is an integer from
0-23
mm is an integer from
0-59
For a list of time zones, see
Time Zone Settings on page 141. NTP must be
disabled before manually setting the date and time.
SET ENCLOSURE ASSET {TAG}
<asset tag>
SET ENCLOSURE NAME
<enclosure name>
SET ENCLOSURE UID [ON | OFF]
Changes the enclosure asset tag Only enclosure administrators
may execute this command.
The <asset tag> must be 1-31 characters long and can include alphanumeric, dash, and underscore characters.
The default enclosure asset tag is blank. To set a blank asset tag, specify the blank value using the quotes.
Changes the enclosure name Only enclosure administrators
may execute this command.
The <enclosure name> must be 1-32 characters long and can include alphanumeric, dash, and underscore characters. <
The default enclosure name is IA-MAC, where MAC is replaced with the actual MAC address.
Turns the enclosure Unit Identification LED on or off Only enclosure administrators
may execute this command.
SET RACK NAME
<rack name>
SHOW CONFIG Displays the script required to recreate the settings of the
Sets the name for the rack where that enclosure resides Only enclosure administrators
may execute this command.
The <rack name> must be 1-32 characters long and can include alphanumeric, dash, and underscore characters.
The default rack name is UnnamedRack.
Only the enclosure
enclosure
Passwords are not included for any user.
administrators may execute this command.
60 Chapter 5 Command Line Interface ENWW
Page 71
(continued)
SHOW DATE Displays the current date, time, and time zone of the internal
clock of the enclosure.
SHOW DISPLAY Displays whether event notification is on or off. None
None
SHOW ENCLOSURE FAN
[fan number> | ALL]<
SHOW ENCLOSURE INFO Displays the enclosure name, type, part number, serial
SHOW ENCLOSURE POWER SUPPLY
[<power supply number> | ALL]
SHOW ENCLOSURE STATUS
SHOW ENCLOSURE TEMP Displays the locale, status (OK, warm, degraded, or failed),
SHOW RACK NAME
<rack name>
Displays the status, redundancy, and partner, speed, part number for the requested fan.
If ALL is entered, this information is shown for all fans.
number, and asset tag; the Integrated Administrator software (including build #) and hardware version; Integrated Administrator MAC address, and the interconnect tray type, part number, and serial number
Displays the power supply status, AC input status, capacity, input voltage range #1 (measured in Volts), input voltage range #2 (if necessary, measured in Volts), input frequency range (measured in Hertz), part number, serial number, and hardware revision for the specified power supply if one is specified or for all power supplies if ALL is given.
Under an enclosure status heading, this command displays the health, Integrated Administrator health, and unit identification LED of the enclosure.
Under a power status heading, this command displays the power status and capacity.
temperature in degrees Fahrenheit, and temperature sensors.
Shows the name for the rack where the enclosure resides
The default rack name is UnnamedRack.
None
None
None
None
None
None
SHOW SYSLOG ENCLOSURE
SHOW TRAY INFO Displays the manufacturer, product name, part number, serial
UPDATE IMAGE
<url>
Displays the syslog of the enclosure with 22 lines per screen.
Typing q quits the command, any other key shows the next screen if more information exists to display.
Typing c continuously displays the System Log without page breaks.
number, and spare number of the interconnect tray.
Downloads a new image from a blade over the network and uses the image to update the firmware of the enclosure.
Only enclosure administrators may execute this command.
None
Only enclosure administrators may execute this command.
URL can be any of the following:
http://host/path
tftp://host/path
ftp://
username:password
@host/path
ftp://host/path where
host is a fully qualified domain name or an IP address and path is the
ENWW Operating the Command Line Interface 61
Page 72
(continued)
pathname of the flash image to download
UPLOAD CONFIG
<url>
For system log severity policy specific settings, these are global and set by the administrator account only. These were added to provide granular control over a specific classification of system log message severity types.
SET SYSLOG POLICY ENCLOSURE
SET SYSLOG POLICY ENCLOSURE ALL [ ON | OFF ]
SET SYSLOG POLICY ENCLOSURE INFORMATIONAL [ ON | OFF ]
SET SYSLOG POLICY ENCLOSURE MAJOR [ ON | OFF ]
SET SYSLOG POLICY ENCLOSURE MINOR [ ON | OFF ]
SET SYSLOG POLICY ENCLOSURE NORMAL [ ON | OFF ]
SET SYSLOG POLICY BAY
SET SYSLOG POLICY BAY ALL [ ON | OFF ]
SET SYSLOG POLICY BAY INFORMATIONAL [ ON | OFF ]
SET SYSLOG POLICY BAY MAJOR [ ON | OFF ]
SET SYSLOG POLICY BAY MINOR [ ON | OFF ]
SET SYSLOG POLICY BAY NORMAL [ ON | OFF ]
Upload the current runtime configuration to the specified FTP or TFTP server.
Only enclosure administrators may execute this command.

Blade PC Bay Management Commands

Table 5-6
Command Description Restrictions
CLEAR BAY BOOT [FIRST | ONCE | ALWAYS] [ALL | <ay number> {[ , | - ] <bay number>}]
CLEAR SESSION BAY
<bay number>
CONNECT BAY
<bay number>
GENERATE NMI
<bay number>
Clears the setting for the IPL to be passed to the blade at the next reboot. The FIRST argument resets the IPL for all subsequent reboots. The ONCE argument resets the IPL for the next reboot only. The Always argument resets the IPL for every reboot. This command is only valid for present blades.
This command may require a firmware update for the BIOS ROM of certain HP blade PCs.
Terminates a Terminal session from the enclosure.
This is not a graceful termination. The connected user loses any unsaved work.
Opens a remote console session to the blade PC with that blade PC bay number.
A blade PC can only support one remote console session at a time.
Generates an NMI on the specified blade.
The consequences of an NMI are operating system specific.
Only enclosure administrators may execute this command.
Enclosure administrators may execute this command for blade PC bays and the interconnect switch.
Only enclosure and group administrators may execute this command.
Only enclosure and group administrators may execute this command.
62 Chapter 5 Command Line Interface ENWW
Page 73
(continued)
NOTE: The blade’s specific
operating system must support the NMI ‘crash dump’ feature or unpredictable results could occur on the blade. Please consult with your specific OS documentation or vendor for details.
POWEROFF BAY
<bay number> {[ , | - ] <bay number>} {FORCE}
POWERON BAY
<bay number> {[ , | - ] <bay number>} {[PXE | HDD | RBSU]}
REBOOT BAY <bay number> {[ , | - ] <bay number>} {FORCE} {[PXE | HDD | RBSU]}
Performs a graceful shutdown of the blade PC in the specified bay.
If the FORCE argument is given, the blade PC is immediately shut down. This means the blade PC could lose data or become unstable. If no blade PC is in the specified bay, the user is told that the bay is empty.
Powers on the specified blade PC.
If no blade PC is in the specified bay, the user is told that the bay is empty.
The optional boot arguments may require a firmware update for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument forces the blade to abandon the regular boot order and forces a boot using the specified method.
Sends a request to the blade PC to perform a graceful shutdown.
The blade PC is then powered on. If no blade PC is in the specified bay, the user is told that the bay is empty.
The optional boot arguments may require a firmware update for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument forces the blade to abandon the regular boot order and forces a boot using the specified method.
Only enclosure and group administrators may execute this command.
Only enclosure and group administrators may execute this command.
Only enclosure and group administrators may execute this command.
SET BAY BOOT FIRST [HDD | PXE] <bay number> {[ , | - ] <bay number>}
SET BAY BOOT ONCE [HDD | PXE | RBSU] <bay number> {[ , | - ] <bay number>}
SET BAY UID <bay number> {[ , | - ] <bay number>} [ON | OFF]
SHOW BAY INFO [ALL | <bay number> {[ , | - ] <bay number>}]
Sets the IPL for each subsequent reboot. This setting is only valid for present blades and is cleared if a blade is removed.
This command may require a firmware update for the BIOS ROM of certain HP blade PCs.
Sets the boot device to be used on the next boot of the bay(s) specified. This setting is only valid on present blades and is cleared if the blade is removed.
This command may require a firmware update for the BIOS ROM of certain HP blade PCs.
Turns a Unit Identification LED on the blade PC on or off. Only enclosure and group
Displays the following fields: Assigned to group, type, name, installed operating system, part number, serial number, asset tag, BIOS version, all CPU types and associated maximum speeds, memory, NIC #1 MAC, and NIC #2 MAC. For BC2x00 blades, the BMC revision is also displayed. BMC version 22 or earlier does not provide this information, so it is assumed version 22h or earlier and indicated as such. When available,
Only enclosure administrators may execute this command.
Only enclosure and group administrators may execute this command.
administrators may execute this command.
Group members and group administrators only see information for the bays in their groups.
ENWW Operating the Command Line Interface 63
Page 74
(continued)
future versions will support this feature. Earlier versions are indicated by (N/A).
If no blade PC is in the bay, the user is shown the assigned to group and the blade PC type.
SHOW BAY LIST [ALL | <group name>]
SHOW BAY STATUS [ALL | <bay number> {[ , | - ] <bay number>}]
SHOW BAY POWER [ ALL | <bay number> {[ , | - ] <bay number>}]
SHOW BAY POWER LIST [ ALL | <bay number> {[ , | - ] <bay number>}]
Displays the assigned to group, remote console user, and blade PC name for each bay in a particular group if a group name is specified or all bays if ALL is specified.
Displays the power (On or Off), assigned to group, remote console user, health, thermal (OK, warm, degraded, or failed), Unit Identification LED (On or Off), and power state for the blade PC.
Displays the measured DC power consumption, AC power consumption estimate, power averaged over the last 24-hr period, and the time averaged power since the blade was inserted.
Displays all of the blade power consumption metrics as mentioned above except for the AC power consumption estimate in a tabular form for ease of viewing.
Group members and group administrators only see information for the bays in their groups.
Group members and group administrators only see information for the bays in their groups.
Group members and group administrators only see information for the bays in their groups.
NOTE: AC Estimate equals
the measured blade DC power divided by the estimated power supply efficiency of the enclosure. Earlier versions are indicated by (N/A).
Group members and group administrators only see information for the bays in their groups.
NOTE: Only BC2x00 blades
provide power measurements. All non-power-aware blades report an (N/A).
SHOW BAY TEMP [ ALL | <bay number> {[ , | - ] <bay number>}]
SHOW SYSLOG BAY
<bay number>
UNASSIGN BAY [ALL | <bay number> {[ , | - ] <bay number>}]
Displays the actual temperature measures for the CPU, graphics processor, and ambient sensors.
Displays the syslog of the specified blade with 22 lines per screen.
Typing q quits the command; any other key shows the next screen if more information is available to display. The system log of the blade PC is not stored between reboots, so the information only includes what has taken place since the last power on of the Integrated Administrator.
Typing c continuously displays the System Log without page breaks.
Removes the bay(s) from their assigned group. Only enclosure administrators

Command Line Event Messages

Table 5-7 Command Line Event Messages
Message Possible Cause
Group members and group administrators only see information for the bays in their groups.
Group members and group administrators only see information for the bays in their groups.
may execute this command.
64 Chapter 5 Command Line Interface ENWW
Page 75
Table 5-7 Command Line Event Messages (continued)
User Event Messages
User Permission Change
Enclosure Event Messages
Enclosure Shutdown
Enclosure Status Change The Integrated Administrator detected a change in status due
Fan Inserted A fan has been inserted.
Fan Removed A fan has been removed.
Fan Status Change The status of fan has changed.
Power Supply Inserted A power supply has been inserted.
Power Supply Overload The power system is overloaded. Check each power supply
Power Supply Redundancy Change The power supplies are now either redundant or no longer
One of the following has occurred:
A user has been added, removed, or modified.
A user’s group membership has been modified.
The blade PC bay membership has been changed for a group with at least one user.
The enclosure is being shut down
to a change in the state of one or more hardware components or blade PC readings.
status to determine cause.
redundant.
Power Supply Removed A power supply has been removed.
Power Supply Status Change The status of a power supply has changed.
Restart Event The Integrated Administrator is about to restart.
Thermal Status Change The state of a thermal sensor has changed.
NOTE: For BC2x00 blades, thermal events reported by the
bay sensor include the bay temperature for the hottest subcomponent sensor reported value.
Bay Event Messages
Bay Event
Blade Inserted A blade PC was inserted into the enclosure.
Blade Removed A blade was removed from the enclosure.
Blade Status Change The health service or Blade Management Controller (BMC)
A blade PC bay has been assigned or unassigned from a group.
detected a change in status due to a change in the state of one or more hardware components or due to a software OS lockup if Automatic System Recovery (ASR) is enabled on the blade.
ENWW Operating the Command Line Interface 65
Page 76
Table 5-7 Command Line Event Messages (continued)
For BC2x00 blades, a diagnostic string accompanies the event message. See possible diagnostic strings and their descriptions.
Blade in bay # has powered off.
Blade in bay # has powered on.
Blade in bay # has started flash mode.
NOTE: Only blades that support a BMC display this
message. Additionally, once flash mode is completed a BAY REMOVED, a BAY INSERTED event message appears. This is a normal part of the flash process and can be safely ignored.
Error Messages on page 122 for
66 Chapter 5 Command Line Interface ENWW
Page 77

Functionality Exclusive to the Command Line Interface

The following table identifies functions or capabilities available to the Command Line Interface (CLI) and unavailable when using the Web-based interface.
Table 5-8 Functions Exclusive to the Command Line Interface—General and General Management
Commands
Function Description Capability Exclusive to CLI
General Commands
Sleep
<seconds>
General Management Commands
CLEAR SESSION SWITCH [A | B]
CLEAR SSHKEY Removes the contents of the Secure Shell authorized keys file.
DOWNLOAD CERTIFICATE
<url>
DOWNLOAD SSHKEY Downloads an authorized key file to use with Secure Shell v2
Pauses the sessions for a fixed period of time. Useful for adding delays to scripts. The <seconds> field can be any whole number from 1 – 86400. Once the pause has started, no way exists to continue the session before time runs out, but you can terminate the session and start another one.
Terminates a Terminal session from the enclosure
This is not a graceful termination. The connected user loses any unsaved work.
After performing this command, you will not be able to login using public key-based authentication.
Downloads a CA supplied PKCS#7 file to replace the current security certificate on the system.
Supported protocols are http, ftp, and tftp. Format the URL as protocol://host/path/file. If your ftp server does not support anonymous connections, you can specify a username and password by augmenting the host part in the above format with username:password@host.
which can contain the public keys for any enclosure administrator. Supported protocols are http, ftp, and tftp. Format the url as protocol://host/path/file. If your ftp server does not support anonymous connections, you can specify a username and password by replacing the host part in the previous format with username:password@host.
None
All
Only enclosure administrators may execute this command.
All
Only enclosure administrators may execute this command.
GENERATE CERTIFICATE REQUEST
GENERATE CERTIFICATE SELFSIGNED
PING {<number>} [<IP address> | <server name>]
SET DISPLAY EVENTS [ON | OFF]
SET EXPERT {MODE} [ON | OFF]
SET FACTORY Sets the Integrated Administrator back to its factory defaults All
Generates a PKCS#10 certificate request All
Generates a self-signed certificate All
Sends ICMP echo messages to a remote IP device
If <number> is omitted, only 5 packets are sent. Packets are sent out at 1-second intervals.
Turns event notification on or off All
Turns EXPERT MODE on or off. When EXPERT MODE is turned on, the system will not prompt the user to confirm actions. Users should exercise caution when working in EXPERT MODE as many actions are not reversible.
All
None
ENWW Functionality Exclusive to the Command Line Interface 67
Page 78
Table 5-8 Functions Exclusive to the Command Line Interface—General and General Management
Commands (continued)
The password of the Administrator account does not change. The Integrated Administrator is restarted after all the changes are made.
NOTE: This command removes all groups, users, and other
customization from the memory of the enclosure, and the information is unrecoverable.
SET SCRIPT MODE [ON | OFF]
SHOW EXPERT {MODE}: Displays the current EXPERT MODE setting for the current
SHOW SESSIONS Displays the connection to each bay and switch if one exists.
SHOW SSHFINGERPRINT Displays the key fingerprint of the host SSH public key for the
SHOW SSHKEY Displays the contents of the existing Secure Shell authorized
DOWNLAOD CONFIG
<url>
When SCRIPT MODE is on, all prompting and verifications of entries cease.
If SCRIPT MODE is on, the following commands require a password argument or a blank password will be assigned: ADD USER, SET USER PASSWORD, or SET PASSWORD.
An enclosure administrator must change the password so that the user can log in to the system. Default values are used for any parameters that would normally require user interaction.
user.
Only one user may connect to each bay and switch at a time. It also shows the users that are currently logged in, their port number, connect time, and remote system name.
Integrated Administrator. This can be used from the serial console to validate the identity of the Integrated Administrator before initializing an SSH connection across a network.
keys file that is being used for enclosure administrator key­based authentication.
Downloads a previously saved configuration file from a specific IP host.
The file is auto-executed in SCRIPT MODE. The file is not allowed to change the password of the Administrator account. Supported protocols are http, ftp, and tftp. Format the URL as protocol://host/path/file. If your ftp server does not support anonymous connections, you can specify a username and password by replacing the host part in the previous format with username:password@host.
All
None
All
None
Only enclosure administrators may execute this command.
All
Table 5-9 Functions Exclusive to the Command Line Interface—Enclosure Management Commands
Function Description Capability Exclusive to CLI
Enclosure Management Commands
SHOW CONFIG
SHOW ENCLOSURE FAN [<fan number> | ALL]
SHOW ENCLOSURE POWERSUPPLY [<power supply number> | ALL]
Displays the script required to recreate the settings of the enclosure.
Passwords are not included for any user.
Displays the status, redundancy, partner, speed, and part number for the requested fan.
Displays the status of the power supply, AC input status, capacity, input voltage range #1 (measured in Volts), input voltage range #2 (measured in Volts), input frequency range
All
The command line adds the fan partner.
The command line adds the input voltage ranges, input frequency range, serial
68 Chapter 5 Command Line Interface ENWW
Page 79
Table 5-9 Functions Exclusive to the Command Line Interface—Enclosure Management Commands
(continued)
(measured in Hertz), part number, serial number, and hardware revision for the specified power supply if one is specified or for all power supplies if ALL is given.
number, and hardware revision.
SHOW ENCLOSURE STATUS
UPDATE IMAGE <URL> Downloads a new image from a server over the network and
UPLOAD CONFIG <url> Uploads the current runtime configuration to the specified FTP
CLEAR SESSION BAY
<bay number>
CLEAR BAY BOOT [FIRST | ONCE] [ALL | <bay number> {[ , | - ] <bay number>}]
GENERATE NMI <bay number>
POWERON BAY <bay number> {[ , | - ] <bay number>} {[PXE | HDD | RBSU]}
Under an enclosure status heading, this command displays the health of the enclosure, Integrated Administrator health, and unit identification LED.
Under a power status heading, this command displays the power status and capacity.
uses the image to update the firmware of the enclosure.
or TFTP server.
Terminates a Terminal session from the enclosure. All
Clears the setting for the IPL to be passed to the blade at the next reboot. The “FIRST” argument resets the IPL for all subsequent reboots. The “ONCE” argument resets the IPL for the next reboot only. This command is only valid for present blades.
This command may require a firmware upgrade for the BIOS ROM of certain HP blade PCs.
Powers on the specified blade PC.
If no blade PC is in the specified bay, the user is told that the bay is empty.
The command line adds the Integrated Administrator health.
All
All
Only enclosure and group administrators may execute this command.
Allows for optional boot argument
REBOOT BAY <bay number> {[ , | - ] <bay number>} {FORCE} {[PXE | HDD | RBSU]}
SET BAY BOOT FIRST [HDD | PXE] <bay number> {[ , | - ] <bay number>}
SET BAY BOOT ONCE [HDD | PXE | RBSU] <bay number> {[ , | - ] <bay number>}
The optional boot arguments may require a firmware upgrade for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument forces the blade to abandon the regular boot order and forces a boot using the specified method.
Sends a request to the blade PC to perform a graceful shutdown.
The blade PC is then powered on. If no blade PC is in the specified bay, the user is told that the bay is empty.
The optional boot arguments may require a firmware upgrade for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument with force the blade to abandon the regular boot order and force a boot using the specified method.
Sets the IPL for each subsequent reboot. This setting is only valid for present blades and is cleared if a blade is removed.
This command may require a firmware upgrade of the BIOS.
Sets the boot device to be used on the next boot of the bay(s) specified. This setting is only valid on present blades and is cleared if the blade is removed.
Allows for optional boot argument
Only enclosure administrators may execute this command
Only enclosure administrators may execute this command.
ENWW Functionality Exclusive to the Command Line Interface 69
Page 80
Table 5-9 Functions Exclusive to the Command Line Interface—Enclosure Management Commands
(continued)
This command may require a firmware upgrade for the BIOS ROM of certain HP blade PCs.
SHOW BAY LIST [ALL | <group name>]
SHOW SYSLOG BAY <bay number>
ADD IPMANAGER <IP address>
DISABLE ALERTMAIL Disables sending e-mail for Integrated Administrator alerts. Only enclosure administrators
DISABLE IPSECURITY Allows all clients to connect to Integrated Administrator. Only enclosure administrators
DISABLE NTP Disables automatic updates of the date and time to the
ENABLE ALERTMAIL Enables sending e-mail for Integrated Administrator alerts. Only enclosure administrators
Displays the assigned to group, remote console user, and blade PC name for each bay in a particular group if a group name is specified or all bays if ALL is specified.
Displays the syslog of a specified blade with 22 lines per screen.
Typing q quits the command; any other key shows the next screen if more information is available to display. The system log of the blade PC is not stored between reboots, so the information only includes what has taken place since the last power on of the Integrated Administrator.
Typing c displays the System Log continuously without page breaks.
Adds an IP address to the list of clients allowed to connect to Integrated Administrator.
Integrated Administrator.
The command line displays the remote console user.
All
Only enclosure administrators may execute this command.
may execute this command.
may execute this command.
Only enclosure administrators may execute this command.
may execute this command.
ENABLE IPSECURITY Restricts clients from being able to connect to Integrated
Administrator.
ENABLE NTP Enables automatic time and date updates to Integrated
REMOVE IPMANAGER <IP address>
SET ALERTMAIL [MAILBOX | SENDERDOMAIN | SMTPSERVER]
SET NTP [PRIMARY | SECONDARY | POLL]
SHOW NETWORK Displays the DHCP state, Dynamic DNS state, IP address,
SET ENCLOSURE SERIAL {NUMBER} <serial number>
SHOW BAY TEMP [ALL | <bay number> {[ , | - ] <bay number>}]
Administrator.
Removes the IP address from the list of clients allowed to connect to Integrated Administrator.
Sets the e-mail address of the alert recipient, the domain name, and the mail server address.
Sets the IP address of the primary and secondary NTP servers. Also sets the frequency of the updates.
subnet mask, gateway address, primary and secondary DNS addresses, MAC address, HTTP and HTTPS server status, SNMP status, Secure Shell status, Telnet status, NTP status, NTP primary and secondary server address, NTP poll interval, NTP last update time, IP security configuration, AlertMail status, AlertMail mailbox, SMTP server address and sender domain of the enclosure.
Allows modification of the serial number reported by the enclosure information.
Displays the actual temperature measures for the CPU, graphics processor, and ambient sensors.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Only enclosure administrators may execute this command.
Group members and group administrators only see information for the bays in their groups.
70 Chapter 5 Command Line Interface ENWW
Page 81

6 Setting Up the System

This chapter explains the levels of user rights recognized by the Integrated Administrator and provides detailed procedures to configure the management functions provided by the Integrated Administrator.
Customizing the enclosure settings
Changing the Administrator password
Modifying enclosure and rack names
Modifying the asset tag number
Modifying the date and time
Setting up user accounts
Adding a group
Adding a user
Enabling remote console sessions to blade PCs
Setting up AlertMail
Adding mailbox address
Adding SMTP server address
Adding Sender Domain
Enabling AlertMail
Disabling AlertMail
Setting up IP Security
Adding IP address
Enabling IP Security
Disabling IP Security
Setting up Automatic Time Configuration (NTP)
Adding primary NTP server
Adding secondary NTP server
Setting the poll interval
ENWW 71
Page 82
Enabling NTP
Disabling NTP
Configuring SNMP support
Entering a community string
Modifying the system location
Modifying the system contact information
Adding trap targets
Removing trap targets
For a detailed explanation of the command line conventions used in this document, see
Conventions on page 121.
These procedures are supported by the Web-based user interface and the CLI unless otherwise noted.
NOTE: Most of these tasks are limited to a subset of users. For more information on who can perform
each task, see
User Permissions on page 72 and the section describing that task in this chapter.

User Permissions

The group-centered approach of Integrated Administrator to user permissions facilitates the maintenance of user groups and groups of blade PC bays. This approach operates according to the following principles:
A blade PC bay is assigned exclusively to one group only.
A group can be assigned many blade PC bays.
A user can have various permission levels within any number of groups.
Access to a blade PC by users or groups depends on the rights assigned to the blade PC bay in
which the blade PC is installed.
Use the following table to distinguish the various permission levels available from the HP PC Blade Enclosure Integrated Administrator.
Command Line
Table 6-1 HP PC Blade Enclosure Integrated Administrator Permissions Levels
Title Account Type Permissions Description
Enclosure Administrator Administrator View/Modify for all
groups in the enclosure
Enclosure administrators may maintain blade PC bay privileges, manage the enclosure, manage blade PC bays, and create and maintain groups.
One special enclosure administrator account (named Administrator) cannot be deleted, disabled, or stripped of enclosure administrator permissions. No other enclosure administrator may change the password to this account.
Enclosure administrators cannot disable or delete their own accounts.
72 Chapter 6 Setting Up the System ENWW
Page 83
Table 6-1 HP PC Blade Enclosure Integrated Administrator Permissions Levels (continued)
Group Administrator User View/Modify Group administrators may manage blade PC
Group member User View Group members may view blade PC bay data
Group member User Group member

Customizing the Enclosure Settings

NOTE: Only enclosure administrators may execute these commands.
To change the default Administrator password using the Web-based user interface:
1. Click the Administration tab.
bay data for groups in which they are administrators.
Group administrators may view blade PC bay data for groups in which they are members.
Group administrators may modify their profile (not their privileges) and view enclosure data.
for groups in which they are members.
Group members may modify their profile (not their privileges) and view enclosure data.
2. Click User List in the side panel.
3. Click the Administrator user name in the user list.
4. Click View/Modify User. The View/Modify User screen displays.
5. Click Change Password.
6. Type in the new Administrator password in the Password and Confirm password fields.
7. Click OK.
To change the default Administrator password using the CLI, type:
SET USER PASSWORD Administrator <new password>
NOTE: The user name (Administrator) is case-sensitive. The <new password> must be 3-8 characters
long and can include all printable characters.

Modifying Enclosure and Rack Names

To modify the enclosure name or rack name using the Web-based user interface:
1. Click the Enclosure tab.
2. Click Enclosure Information in the left panel.
3. Click the Enclosure Name field of the Status area.
4. Type the enclosure name.
5. Click the Rack Name field of the Status area.
ENWW Customizing the Enclosure Settings 73
Page 84
6. Type the rack name.
7. Click Apply.
To modify the enclosure name or rack name using the CLI, type the following commands sequentially: SET ENCLOSURE NAME <enclosure name>
NOTE: The <enclosure name> must be 1-32 characters long and includes all alphanumeric, the dash,
and the underscore characters.
The default enclosure name is IA-XXXXXXXXXXXX where XXXXXXXXXXXX is replaced with the actual MAC address: SET RACK NAME <rack name>
NOTE: The <rack name> must be a maximum of 32 characters long and includes all alphanumeric,
dash, and underscore characters. The default rack name is UnnamedRack.

Modifying the Asset Tag Number

To modify the asset tag number using the Web-based user interface:
1. Click the Enclosure tab.
2. Click Enclosure Information in the left panel.
3. Scroll down to the General area.
4. Click the Asset Tag field.
74 Chapter 6 Setting Up the System ENWW
Page 85
5. Type the asset tag number.
6. Click Apply.
To modify the asset tag number using the CLI, type:
SET ENCLOSURE ASSET {TAG} <asset tag>
NOTE: The <asset tag> must be 1-31 characters long and includes alphanumeric, dash, and
underscore characters. The default enclosure asset tag is blank.

Modifying the Date and Time

To modify the date and time settings using the Web-based user interface:
1. Click the Enclosure tab.
2. Click Enclosure Information in the left panel.
3. Scroll down to the Date and Time area.
4. Select the proper time zone from the pull-down list.
5. Click the Date or Time field.
ENWW Customizing the Enclosure Settings 75
Page 86
6. Type the date or time.
7. Click Apply.
To modify the date and time settings using the CLI, type:
SET DATE MMDDhhmm{{CC}YY} {TZ}
where:
MM: month
DD: day
hh: hour (24-hour time, an integer from 0-23)
mm: minute
CC: century
YY: year
TZ: timezone
NOTE: If the time zone is left blank, the current time zone is left in effect. For a list of supported time
zones, see
Time Zone Settings on page 141.
76 Chapter 6 Setting Up the System ENWW
Page 87

Setting Up User Accounts

NOTE: Only enclosure administrators may perform this task.
The Integrated Administrator enables you to manage blade PC bays and administer users by organizing those blade PC bays and users into groups.
This approach enables enclosure administrators, for example, to re-assign user permissions to groups of blade PCs en masse, instead of requiring enclosure administrators to modify permissions one user at a time.
Enclosure administrators assign users access rights to blade PC bays through the following tasks:
Adding groups with access to specific blade PC bays in an enclosure
Adding users with certain permissions within specific groups

Adding a Group

NOTE: Restricted default names of group and user accounts (Administrator, switch, switcha, switchb,
and SAM) are not case-sensitive. Nondefault group and user names are case-sensitive.
For more information on the Web-based user interface screens for this function, see Group List
on page 40. For information on using the CLI, see User Account Commands on page 53.
To create a group using the Web-based user interface:
1. Click the Administration tab.
2. Click Add Group in the left panel.
3. Type the group name and description in the fields.
ENWW Setting Up User Accounts 77
Page 88
4. Select bays for the group by selecting the appropriate check boxes.
NOTE: If a blade PC bay is gray, that blade PC bay is inaccessible because it already belongs
to another group.
78 Chapter 6 Setting Up the System ENWW
Page 89
5. To add existing users to this group:
a. Select users in the User Names area.
b. Click Add User [View] or Add User [View/Modify]. For more information on permission
6. Click Apply.
To create a group using the CLI, type the following commands sequentially:
ADD GROUP <group name>
NOTE: The <group name> must be unique to all other group names and user names and is case-
sensitive. It must be 1-13 characters long and can include all alphanumeric characters, the dash, and the underscore.
SET GROUP {DESCRIPTION} <group name><description>
NOTE: The <description> must be 1-20 characters long and can include all alphanumeric characters,
the dash, the underscore, and spaces.
ASSIGN BAY [ALL | <bay number> {[ , | - ]<bay number>}] <group name>
ASSIGN USER <user name> <group name> {[VIEW | MODIFY]}
NOTE: The <use name> and <group name> are case-sensitive. The Administrator account cannot be
added to a group. The default setting is View.

Adding a User

levels, see
User Permissions on page 72 in this chapter.
NOTE: Restricted default names of group and user accounts are not case-sensitive. Nondefault group
and user names are case-sensitive.
ENWW Setting Up User Accounts 79
Page 90
For information on permission levels, see User Permissions on page 72 in this chapter.
To create a user using the Web-based user interface:
1. Click the Administration tab.
2. Click Add User in the left panel.
3. Type the user information in the appropriate field. For information on “Account Type,” see
Permissions on page 72 in this chapter.
User
NOTE: The Account Type setting determines whether the account holder has management
permissions. The optional Full Name and Contact Information fields provide the account holder’s name and a readily accessible means of contact in case of emergency.
80 Chapter 6 Setting Up the System ENWW
Page 91
4. To assign the user to an existing group:
a. Select groups in the Group Names area.
b. Click Add User [View] or Add User [View/Modify]. For more information on permission
levels, see
5. 5. Click Apply.
User Permissions on page 72 in this chapter.
To add a user using the CLI, type the following commands sequentially:
ADD USER <user name> {<password>}
ENWW Setting Up User Accounts 81
Page 92
NOTE: The <user name> must be unique to all other user names and group names and is case-
sensitive. It must be 1-13 characters long and can include all alphanumeric characters, the dash, and the underscore. The <password> must be 3-8 characters long and includes all printable characters.
ASSIGN ADMINISTRATOR {RIGHTS} <user name>
SET USER FULLNAME {<user name>} <full name>
NOTE: The <full name> must be 1-20 characters long and can include all alphanumeric characters,
the dash, the underscore, and spaces.
SET USER CONTACT {<user name>} <contact info>
NOTE: The <contact info> must be 1-20 characters long and can include all alphanumeric characters,
the dash, the underscore, and spaces.
ASSIGN USER <user name> <group name> {[VIEW | MODIFY]}

Enabling Remote Console Sessions to Blade PCs

The remote console feature of the Integrated Administrator enables a user to connect to the console (serial) connector of the blade PC in order to access the ROM-Based Setup Utility (RBSU). Accessing the RBSU of the blade PC requires nothing more than connecting to the blade PC.

Setting Up AlertMail

AlertMail enables users to receive system events by e-mail instead of using SNMP traps. AlertMail is completely independent from SNMP and both can be enabled at the same time. AlertMail uses standard SMTP commands to communicate with an SMTP capable mail server.
Table 6-2 AlertMail Commands
Function Command
Add an e-mail address using command line interface SET ALERTMAIL MAILBOX <e-mail
Add an SNMP server address SET ALERTMAIL
Set the sender domain SET ALERTMAIL
Enable Alertmail ENABLE ALERTMAIL
Disable Alertmail DISABLE ALERTMAIL
address>
SMTPSERVER
<ip address>
SENDERDOMAIN
<domain name>
* For security reasons, some SMTP servers will only forward mail if the sender’s domain is set properly. You may need to set this parameter to match the network domain.
82 Chapter 6 Setting Up the System ENWW
Page 93

E-mail Alerts

AlertMail, if enabled, will send out alerts by e-mail for the following events:
Enclosure boot message
IA reboot message
Fan status change
Fan inserted
Fan removed
Enclosure thermal status change
Power supply status change
Power supply inserted
Power supply removed
Power subsystem redundancy change
Blade inserted
Blade removed
Blade status change
Blade thermal change
Blade fault
Blade diagnostic string (BC2x00 only) (See
diagnostic strings.)
NOTE: If the enclosure has a switch installed, it can take up to 60 seconds before the system will send
out an AlertMail after a system boot up. Events generated within this period of time will be sent out when the switch has come online.
All e-mails have the following header:
Subject: HP AlertMail-SEQ: <SEVERITY> SUBJECT
Date: Date in standard format
From: Enclosure ENCLOSURE-NAME <enclosure-name@domain>
To: RECEIVER MAILBOX
Where SEVERITY is one of the following (from highest to lowest):
# CRITICAL
# WARNING
Error Messages on page 122 for a list of blade specific
# NOTICE
# INFO
Example e-mail:
ENWW Setting Up AlertMail 83
Page 94
----SAMPLE START----
Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed
Date: Wed, 23 Apr 2003 15:02:22 +0200
From: Enclosure IA-00508BEBA571 <IA-00508BEBA571@hp.com>
To: user@userdomain
X-OS: HP Integrated Administrator
X-Priority: 1
Content-Type: text/plain; charset=us-ascii
EVENT (26 May 07:09): Power Supply #1 Status has changed to: Failed
Enclosure, IA-00508BEBA571, has detected that a power supply in bay 1 has changed from status OK to Failed.
The power supply should be replaced with the appropriate spare part. You can ensure that the center wall assembly is operating correctly by swapping the two power supplies. Make sure that there are no bent pins on the power supply connectors before reinserting and that each power supply is fully seated.
An amber LED on the power supply indicates either an over-voltage, over­temperature, or loss of AC power event has occurred. A blinking LED on the power supply indicates a current limit condition.
Enclosure Status: Degraded
Enclosure Management URL: <https://16.181.75.213/>
- PLEASE DO NOT REPLY TO THIS EMAIL –
----SAMPLE END----

Setting Up IP Security

NOTE: This is not IPSec.
IP security allows an administrator to define a set of IP addresses that are the only ones allowed to connect to the services provided (SSH, HTTP, TELNET, SNMP). This means that an administrator can make sure only a certain set of machines have access to Integrated Administrator. You can enter a maximum of five IP addresses.
Table 6-3 IP Security Commands
Function Command
Add an IP address ADD IPMANAGER <ipaddress>
Remove an IP address REMOVE IPMANAGER <ip address>
Enable IP security ENABLE IPSECURITY
Disable IP security DISABLE IPSECURITY
84 Chapter 6 Setting Up the System ENWW
Page 95

Setting Up Automatic Time Configuration (NTP)

Automatic time configuration allows the Integrated Administrator to synchronize its date and time with an NTP capable device supporting the Network Time Protocol (NTP).
Table 6-4 Automatic Time Configuration Commands
Function Command
Set the NTPpoll interval* SET NTP POLL
<seconds>
Set the primary NTP server SET NTP PRIMARY
<ip address>
Set the secondary NTP server SET NTP SECONDARY <ip address>
Disable the secondary NTP server SET NTP SECONDARY NONE
Enable NTP ENABLE NTP
Disable NTP DISABLE NTP
* If an NTP poll interval is not set, it will default to 720 seconds. The minimum time is 60 seconds and the maximum time is 9999 seconds.
ENWW Setting Up Automatic Time Configuration (NTP) 85
Page 96

Configuring SNMP Support

NOTE: Only enclosure administrators may execute these tasks.

Entering a Community String

To enter a read community or write community string using the Web-based user interface:
1. Click the Enclosure tab.
2. Click SNMP Configuration in the left panel.
3. Click the Read Community or Write Community field.
4. Type the string.
NOTE: Entering a blank string into the Read Community field sets the Read Community to
“public.” Entering a blank string into the Write Community field disables the SNMP set commands.
5. 5. Click Apply.
To enter a read community or write community string using the CLI, type:
SET SNMP COMMUNITY [READ | WRITE] <community name>
The write <community name> must be 1-20 characters long and the read <community name> must be 1-20 characters long. Both community names support all alphanumeric characters, the underscore, and the dash characters.
86 Chapter 6 Setting Up the System ENWW
Page 97
The default read community name is “public,” and the default write community name is blank.

Modifying the System Location

NOTE: The SNMP protocol can be disabled in the Network Configuration area of the Web-based user
interface.
To modify the system location information using the Web-based user interface:
1. Click the Enclosure tab.
2. Click SNMP Configuration in the left panel.
3. Set the cursor in the System Location field and type the appropriate information.
4. Click Apply.
To modify the system location information using the CLI, type:
SET SNMP LOCATION <location>
The <location> field must be 1-20 characters long and supports all the alphanumeric characters, the underscore, the dash, and spaces with quotes.

Modifying the System Contact Information

To modify the system contact information using the Web-based user interface:
1. Click the Enclosure tab.
2. Click SNMP Configuration in the left panel.
3. Set the cursor in the System Contact field and type the appropriate information.
4. Click Apply.
To modify the system contact information using the CLI, type:
SET SNMP CONTACT <contact>
The <contact> field must be 1-20 characters long and supports all the alphanumeric characters, the underscore, the dash, and spaces with quotes.

Adding Trap Targets

To add a trap target using the Web-based user interface:
1. Click the Enclosure tab.
2. Click SNMP Configuration in the left panel.
3. Type the IP address in the appropriate field of the SNMP area.
4. Click Add.
5. Click Apply.
To add a trap target using the CLI, type:
ADD SNMP TRAPRECEIVER <IP address>
ENWW Configuring SNMP Support 87
Page 98
The <IP address> must be in the form ###.###.###.###, where ### ranges from 0 to 255.
The Integrated Administrator only supports v1 traps and directs the traps to SNMP port 162 by default. You can add a maximum of eight IP addresses to receive SNMP traps.

Removing Trap Targets

To remove a trap target list using the Web-based user interface:
1. Click the Enclosure tab.
2. Click SNMP Configuration in the left panel.
3. Type the list name in the appropriate field of the SNMP area.
4. Click Remove.
5. Click Apply.
To add or remove a trap target list using the CLI, type:
REMOVE SNMP TRAPRECEIVER <IP address>
The <IP address> must be in the form ###.###.###.###, where ### ranges from 0 to 255.
88 Chapter 6 Setting Up the System ENWW
Page 99

7 Configuring SOAP Support Tasks

Enabling SOAP Interface

To enable the SOAP interface via the Web-based user interface:
1. Click the Enclosure tab.
2. Click Network Configuration in the left panel.
3. Click the SOAP button to Enable
4. Click Apply.
To enable the SOAP interface via the CLI-based user interface, type:
ENABLE SOAP

Disabling SOAP Interface

To disable the SOAP interface via the Web-based user interface:
1. Click the Enclosure tab.
2. Click Network Configuration in the left panel.
3. Click the SOAP button to Disable
4. Click Apply.
To disable the SOAP interface via the CLI-based user interface, type:
DISABLE SOAP
ENWW Enabling SOAP Interface 89
Page 100

Supported SOAP Interface Commands

The following table contains a summary of the supported SOAP interface commands a short description:
Command Description
userLogin Establishes a SOAP session with the IA for using SOAP interface web services.
userLogout userLogout Closes a SOAP session with the IA.
modifyPassword Change user account password via SOAP interface.
getEnclosurePowerCollectionInfo Gets information about the power regulator and power reporting capabilities of the
enclosure.
setEnclosurePowerCollectionInfo Sets information about the power regulator and power reporting capabilities of the
getEnclosurePowerRecords Returns collected power history data points for the enclosure.
getBladePowerCollectionInfo Gets information about the power regulator and power reporting capabilities of a given bay.
setBladePowerCollectionInfo Sets information about the power regulator and power reporting capabilities of a given bay.
getBladePowerRecords Returns collected power history data points for the a given bay.
getEnclosureInfo Functions like CLI Get Enclosure Info command minus some IA specific information.
getIAInfo Gets IA specific information.
getEnclosureStatus Functions like CLI Get Enclosure Status command.
setBladePowerState Functions like CLI power[on / off] {bay #} command.
getBladePowerState Gets the power state of the blade.
getBladeStatus Functions like CLI Get Blade Status {bay #} command.
getBladeStatusArray Functions like CLI Get Blade Status All command.
getBladeInfo Functions like CLI Get Blade Info {bay #} command.
getEnclosurePowerData Provides a snapshot of the most recent power data points collected.
enclosure. Allows setting of a 1 minute, 5 minute, 10 minute, 1 hour, or for 24 hour sample rate.
Allows setting of a 1 minute, 5 minute, 10 minute, 1 hour, or for 24 hour sample rate.
A future specification will contain the XML schema and description for these commands. Please refer to it for further details.
90 Chapter 7 Configuring SOAP Support Tasks ENWW
Loading...