HP 378927-B21 Quickspecs

Page 1
QuickSpecs
Overview
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
OR
OR
OROR
Patch Panel (shown) or Patch Panel 2
Brocade 4Gb SAN Switch for HP p-Class BladeSystem
At A Glance
At A Glance
At A GlanceAt A Glance
This document covers the HP BladeSystem p-Class Interconnects Components only. For more information on HP ProLiant Server Blades and HP BladeSystem p-Class Infrastructure please see the following QuickSpecs:
OR
OR
OROR
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or CGESM Interconnect Switch (fiber or copper-
based)
HP ProLiant Server Blade QuickSpecs: HP BladeSystem p-Class Infrastructure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12330_div/12330_div.HTML
HP BladeSystem solutions starts with a Server Blade Enclosure, HP ProLiant Server Blades, networking interconnects, SAN switches, management tools and a centralized power sub-system.
Cisco Gigabit Ethernet Switch Module (CGESM) option for Gigabit Ethernet network adapter consolidation. Types of interconnects available: GbE Interconnect Switches, GbE2 and CGESM Interconnect Switches with optional Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through. Please see the following URL for additional information:
http://h18000.www1.hp.com/products/quickspecs/12164_div/12164_div.HTML
NOTE:
NOTE:
For additional information on HP BladeSystem SAN switches, please see the following URL:
NOTE:NOTE:
http://h18004.www1.hp.com/products/blades/components/san-switches.html
NOTE:
NOTE:
HP ProLiant server blades, p-Class server blade enclosures, interconnects and power enclosures protected by a limited three
NOTE:NOTE:
http://h18000.www1.hp.com/products/quickspecs/Division/11070.html
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 1
Page 2
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Overview
year warranty with optional service uplifts available. The warranty for p-Class SAN switches is unique to the SAN switch which is a one year warranty that is upgradeable to three years via CarePack.
HP ProLiant Server Blades in HP BladeSystem p-Class Server Blade Enclosure
HP ProLiant Server Blades in HP BladeSystem p-Class Server Blade Enclosure
HP ProLiant Server Blades in HP BladeSystem p-Class Server Blade EnclosureHP ProLiant Server Blades in HP BladeSystem p-Class Server Blade Enclosure
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 2
Page 3
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Standard Features (HP BladeSystem p-Class Interconnect Components)
HP ProLiant BL p-Class Interconnect Components
HP ProLiant BL p-Class Interconnect Components
HP ProLiant BL p-Class Interconnect ComponentsHP ProLiant BL p-Class Interconnect Components
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch Option
Option
OptionOption
(Every HP BladeSystem p­Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels)
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL30p, HP ProLiant BL35p, HP ProLiant BL40p and HP ProLiant BL45p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure.
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect Switch or one CGESM with four (4) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per server blade enclosure. The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for Fibre Channel pass-through when using either the GbE2 or CGESM Interconnect Kit.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant Server Blade Fibre Channel pass­through.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure. The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ­45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port Redundant crosslink ports connecting the two interconnect switches Redundant power inputs and on-board redundant fans Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Power ON, management, and per port status and speed LED indicators Reset/power momentary push-button switch HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD Fully pre-configured for rapid deployment and immediate operation
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 3
Page 4
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Standard Features (HP BladeSystem p-Class Interconnect Components)
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-
45 10/100 T/TX external ports per server blade enclosure. ProLiant BL Interconnect Switch Management System and Utilities: Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level
user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more.
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Storage Connectivity Kit
Storage Connectivity Kit
Storage Connectivity KitStorage Connectivity Kit Option
Option
OptionOption (Supports two CGESM or GbE2 switches per kit)
The Storage Connectivity Kit is used if Fibre Channel signal pass-through is desired when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and SAN connectivity is possible using a single interconnect option. Order one Storage Connectivity Kit per server blade enclosure for Fibre Channel pass through. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver slots for the pluggable small form factor transceivers that come with each Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to sixteen Fibre Channel signals).
HP ProLiant BL p-Class
HP ProLiant BL p-Class
HP ProLiant BL p-ClassHP ProLiant BL p-Class SAN Switches
SAN Switches
SAN SwitchesSAN Switches
Embedded Fibre Channel SAN switching within the p-Class Server Enclosure. Brocade and McDATA based SAN switches featuring 4Gb ASIC technology providing fabric connectivity for all HP ProLiant BL p-Class Server blades.
The Brocade 4Gb SAN Switch for HP p-Class BladeSystem
The Brocade 4Gb SAN Switch for HP p-Class BladeSystem
The Brocade 4Gb SAN Switch for HP p-Class BladeSystemThe Brocade 4Gb SAN Switch for HP p-Class BladeSystem switch. Three factory configurations:
Base unit - Includes Advanced Web Tools and Zoning. Limited to 2 switches (domains) in a single
fabric. (P/N A7533A)
Full Fabric - Includes Advanced Web Tools and Zoning. Full Fabric support to current scalability
limit of 2560 ports and 50 domains per single SAN fabric. (P/N A7534A)
Power Pack - Includes all features and functionality of Full Fabric, as well as, Enterprise license
features: Trunking, Advanced Performance Monitoring, Fabric Watch and Extended Fabrics (P/N
A7535A)
For additional information on the Brocade 4Gb SAN Switch for HP p-Class BladeSystem please see the following URL:
The McDATA 4Gb SAN Switch for HP p-Class BladeSystem
The McDATA 4Gb SAN Switch for HP p-Class BladeSystem
The McDATA 4Gb SAN Switch for HP p-Class BladeSystemThe McDATA 4Gb SAN Switch for HP p-Class BladeSystem Switch. This product comes in one factory configuration.
Full Fabric Switch - Includes and switch hardware and firmware. (P/N A8001A)
There is an enhanced software license available for the McDATA SAN switch.
McDATA Enhanced Software License (P/N T4263A)
License includes:
http://h18006.www1.hp.com/products/storageworks/b4gbsanswitchblade/index.html
McDATA SANtegrity Binding McDATA SANtegrity Authentication
is a 4Gb 12 port Fibre Channel SAN
is a 4Gb 10 port Fibre Channel SAN
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 4
Page 5
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Standard Features (HP BladeSystem p-Class Interconnect Components)
For additional information on the McDATA 4Gb SAN Switch for HP p-Class BladeSystem please see the
HP ProLiant BL p-Class
HP ProLiant BL p-Class
HP ProLiant BL p-ClassHP ProLiant BL p-Class RJ-45 Patch Panel
RJ-45 Patch Panel
RJ-45 Patch PanelRJ-45 Patch Panel (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
HP ProLiant BL p-Class
HP ProLiant BL p-Class
HP ProLiant BL p-ClassHP ProLiant BL p-Class RJ-45 Patch Panel 2
RJ-45 Patch Panel 2
RJ-45 Patch Panel 2 RJ-45 Patch Panel 2 Fibre Channel pass through) (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
NOTE:
NOTE:
The Patch Panel 2
NOTE:NOTE: or a Switch Interconnect Kit is required for SAN connectivity on HP
(with
following URL:
NOTE:
NOTE:
Both Brocade and McDATA SAN switches are shipped in singles (one switch per kit), for
NOTE:NOTE: redundant configurations please order two switch kits.
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections
Supports Gigabit Ethernet network adapters
16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure)
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also
used to pass Fibre Channel signals for SAN connectivity Supports Gigabit Ethernet network adapters 16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade
enclosure) Fibre Channel,
Fibre Channel,
Fibre Channel,Fibre Channel, pass through
pass through
pass throughpass through
http://h18006.www1.hp.com/products/storageworks/mcd4gbsanswitch/index.html
Fibre Channel signals travel from a HP ProLiant BL25p server blade with a Dual-Port Fibre Channel Adapter through p-Class server blade enclosure backplane. The Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals and one Fibre Channel signal terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal travels terminates through the left RJ-45 Patch Panel 2.
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the BL20p G3 Dual-port Fibre Channel Adapter.
Required Network
Required Network
Required NetworkRequired Network Cabling
Cabling
CablingCabling
10Base-T
100Base-TX
1000Base-T
1000Base-SX
NOTE:
NOTE:
NOTE: NOTE:
http://www.compaq.com/products/servers
For cabling information, refer to the Web site at:
DA - 12331 Worldwide — Version 4 — September 12, 2007
Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
.
Page 5
Page 6
QuickSpecs
Standard Features
Intelligent Manageability
Intelligent Manageability
Intelligent ManageabilityIntelligent Manageability
Availability
Availability
AvailabilityAvailability
Interconnect Switch Management System and Utilities (Interconnect Switch option)
Interconnect Switch Availability
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Two network connections per server blade bay (four NICs total) routed to two redundant
interconnect switches
Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports
per each interconnect switch
Redundant front panel ports per each interconnect switch for diagnostics, management, and
additional uplinks
Redundant serial ports
Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support
for loop-free path redundancy
Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and
failover
Redundant configuration files and operating system firmware images in memory (GbE2 switch)
Redundant fans per each interconnect switch
Redundant 1+1 power to each interconnect switch
Support for ProLiant network adapter teaming
Redundant configurable community strings and SNMP trap manager hosts
Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Security
Security
SecuritySecurity
Factory Express Portfolio
Factory Express Portfolio
Factory Express PortfolioFactory Express Portfolio for Servers and Storage
for Servers and Storage
for Servers and Storagefor Servers and Storage
Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction
*
NOTE:
NOTE:
CGESM and GbE2 Interconnect Switch only
NOTE:NOTE:
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging and custom packaging. HP products supported through Factory Express include: a wide array of servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales representative or go to
http://www.hp.com/go/factory-express
.
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 6
Page 7
QuickSpecs
Standard Features
Service and Support
Service and Support
Service and SupportService and Support
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements.
NOTE:
NOTE:
Server Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. This
NOTE:NOTE: warranty supports the HP ProLiant BL20p, HP ProLiant 25p, HP ProLiant 40 and HP ProLiant 45p Server Blades. NOTE:
NOTE:
NOTE: NOTE: warranty supports the HP ProLiant BL30p and HP ProLiant 35p Server Blades. NOTE:
NOTE:
NOTE: NOTE: support. Additional information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs.
HP Care Pack services for HP BladeSystem p-Class server blade enclosure covers the enclosure including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and power distribution.
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Server Blade Limited Warranty includes 3 year Parts, 1 year Labor, 1-year on-site support. This
Server Blade Enclosure Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site
To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP BladeSystem server support offer to help you speedily deploy and maximize system uptime.
Recommended Service
Recommended Service
Recommended Service Recommended Service
Support Service
Support Service
Support Service Support Service
Deployment Service
Deployment Service
Deployment Service Deployment Service
Enhanced Service
Enhanced Service
Enhanced ServiceEnhanced Service
Support Service
Support Service
Support ServiceSupport Service
Deployment Service
Deployment Service
Deployment ServiceDeployment Service
Installation & Start-Up service for HP BladeSystem Infrastructure plus HP BladeSystem Enhanced Network Installation and Start-UP as per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays.
For a complete listing of service offerings and information visit:
http://www.hp.com/services/bladesystemservices http://www.hp.com/go/proliant/carepack
- Simplify ProLiant solution implementation, maintenance and management.
- 4-Hour Response Coverage, 3-Year, 24 x 7, Same Business Day
- Installation and Start Up for HP BladeSystem Infrastructure
- Optimize service level to increase IT performance and availability
- HP Proactive BladeSystem Service, 1-Year
- Enhanced Network Installation and Start-up for HP BladeSystem Switches
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 7
Page 8
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Options
Configuration Steps
Configuration Steps
Configuration StepsConfiguration Steps
For a complete configuration on the HP ProLiant Server Blades, please do the following: Step 1: Select desired model, configuration and quantity of HP ProLiant server blades
Step 1: Select desired model, configuration and quantity of HP ProLiant server blades
Step 1: Select desired model, configuration and quantity of HP ProLiant server bladesStep 1: Select desired model, configuration and quantity of HP ProLiant server blades
NOTE:
NOTE:
NOTE: NOTE:
Step 2: Determine quantity of HP BladeSystem p-Class Server Blade Enclosures to purchase
Step 2: Determine quantity of HP BladeSystem p-Class Server Blade Enclosures to purchase
Step 2: Determine quantity of HP BladeSystem p-Class Server Blade Enclosures to purchaseStep 2: Determine quantity of HP BladeSystem p-Class Server Blade Enclosures to purchase
NOTE:
NOTE:
NOTE: NOTE: depending on server blade selection. NOTE:
NOTE:
NOTE:NOTE:
http://h18000.www1.hp.com/products/quickspecs/12330_div/12330_div.HTML
Step 3: Select an interconnect kit. Each interconnect kit contains a pair of interconnects except the Cisco GESM which
Step 3: Select an interconnect kit. Each interconnect kit contains a pair of interconnects except the Cisco GESM which
Step 3: Select an interconnect kit. Each interconnect kit contains a pair of interconnects except the Cisco GESM whichStep 3: Select an interconnect kit. Each interconnect kit contains a pair of interconnects except the Cisco GESM which contains a single switch per kit. One pair of interconnects is required with each blade enclosure.
contains a single switch per kit. One pair of interconnects is required with each blade enclosure.
contains a single switch per kit. One pair of interconnects is required with each blade enclosure.contains a single switch per kit. One pair of interconnects is required with each blade enclosure.
NOTE:
NOTE:
NOTE:NOTE:
http://h18000.www1.hp.com/products/quickspecs/12164_div/12164_div.HTML
For server blade information, please visit:
Each HP BladeSystem p-Class Server Blade Enclosure holds 2,4,8 or 16 HP ProLiant server blades plus two Interconnects
For additional information on HP BladeSystem p-Class Infrastructure please visit:
For additional information on Interconnect Options, please visit:
http://h18000.www1.hp.com/products/quickspecs/Division/11070.html
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Interconnects
p-Class Interconnects
p-Class Interconnectsp-Class Interconnects
RJ-45 Patch Panel 2 with Fibre Channel pass through
NOTE:
NOTE:
Required for Fibre Channel connectivity on HP ProLiant BLXXp when using the
NOTE:NOTE: patch panel interconnect
Brocade 4Gb SAN Switch for HP p-Class BladeSystem Brocade 4Gb SAN Switch Full Fabric Switch Brocade 4Gb SAN Switch w/Power Pack
NOTE:
NOTE:
Two SAN switch kits required per server blade enclosure
NOTE:NOTE:
NOTE:
NOTE:
Two SAN switch kits required per server blade enclosure.
NOTE:NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only
NOTE:
NOTE:
Two CGESM interconnect kits required per server blade enclosure.
NOTE:NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules
NOTE:
NOTE:
Two CGESM interconnect kits required per server blade enclosure.
NOTE:NOTE:
Cisco RJ-45 10/100/1000 T/TX/T SFP Module 1000BASE SX Fiber SFP Module ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadT2 Interconnect Modules)
NOTE:
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:NOTE:
HP ProLiant BL p-Class Storage Connectivity Kit
NOTE:
NOTE:
Required for BLXXp Fibre Channel signal pass through when using the
NOTE:NOTE: CGESM or GbE2 Interconnect Switch. NOTE:
NOTE:
Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit.
NOTE:NOTE: NOTE:
NOTE:
Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit.
NOTE:NOTE:
306465-B21
A7533A A7534A A7535A
A8001A
378926-B21
378927-B21
378928-B21 378929-B21 283192-B22
321745-B21
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 8
Page 9
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Options
Step 4: Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration
Step 4: Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration
Step 4: Select a HP BladeSystem p-Class power enclosure and power supplies based on configurationStep 4: Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration
NOTE:
NOTE:
For additional information on HP BladeSystem p-Class Infrastructure please visit:
NOTE:NOTE:
http://h18000.www1.hp.com/products/quickspecs/12330_div/12330_div.HTML
Use p-Class sizing tool to help determine power configuration:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
NOTE:
NOTE:
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
NOTE:NOTE:
Step 5: Select power distribution
Step 5: Select power distribution
Step 5: Select power distributionStep 5: Select power distribution
NOTE:
NOTE:
For additional information on HP BladeSystem p-Class Infrastructure please visit:
NOTE:NOTE:
http://h18000.www1.hp.com/products/quickspecs/12330_div/12330_div.HTML
Service and Support
Service and Support
Service and SupportService and Support Offerings
Offerings
Offerings Offerings Services)
(HP Care Pack
(only required with 3U power enclosures)
NOTE:
NOTE:
The HP Care Pack service part numbers below for ProLiant BL p-Class server
NOTE:NOTE: blades, cover the server blade and all HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the server.
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site ServiceHardware Services On-site Service 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
NOTE:
NOTE:
The HP Care Pack service part numbers below for HP BladeSystem p-Class
NOTE:NOTE: server blade enclosure covers the enclosure including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site ServiceHardware Services On-site Service 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
NOTE:
NOTE:
The HP Care Pack service part numbers below covers the HP BladeSystem
NOTE:NOTE: Brocade and McData SAN Switches.
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site ServiceHardware Services On-site Service 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, (24 port) Electronic
UD188E
HC031E
UC009E
UE438E
Installation & Start-up Services
Installation & Start-up Services
Installation & Start-up ServicesInstallation & Start-up Services HP Installation & Startup Service for HP BladeSystem Infrastructure
NOTE:
NOTE:
Provides for an integrated hardware and software implementation that
NOTE:NOTE: includes remote service planning, onsite deployment of hardware and software, installation verification testing and customer orientation. Hardware deployment covers the installation of a single BladeSystem enclosure that include server blades (up to
16), Ethernet network interconnect, and power options. Software deployment covers the installation and configuration of HP Systems Insight Manager (SIM), HP Rapid Deployment Pack (RDP), and deploy up to two operating system editions of either Windows or Linux, using scripted operating system installation software.
HP BladeSystem Enhanced Network Installation and Startup Service, Electronic HP Proactive BladeSystem Service Care Pack
HP Proactive BladeSystem Service Care Pack
HP Proactive BladeSystem Service Care PackHP Proactive BladeSystem Service Care Pack 1 Year, HP Proactive BladeSystem Service
NOTE:
NOTE:
For more information, customer/resellers can contact
NOTE:NOTE:
http://www.hp.com/hps/carepack/services/
UC905E
UE603E
UG858E
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 9
Page 10
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45 Patch Panel 2 with Fiber
Patch Panel 2 with Fiber
Patch Panel 2 with FiberPatch Panel 2 with Fiber Channel pass through
Channel pass through
Channel pass throughChannel pass through
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Fiber Channel SAN
Fiber Channel SAN
Fiber Channel SANFiber Channel SAN Connector
Connector
ConnectorConnector
Cable Support
Cable Support
Cable SupportCable Support
EMI
EMI
EMIEMI
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Velio VC1070 re-timer Network Fiber Channel SAN 10 Base-TX
100 Base-TX 1000 Base-TX Fiber Channel FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps Auto-rate negotiate between 2G and 1G RJ-45 in the back. Pluggable SFP optical slot in the front. Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft/100 m Category 5E (4 pair); up to 328 ft (100 m) SFP optical cable
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45 Patch Panel
Patch Panel
Patch PanelPatch Panel
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector Cable Support
Cable Support
Cable SupportCable Support
Power Requirements
Power Requirements
Power RequirementsPower Requirements Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing)
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Network 10 Base-TX
100 Base-TX 1000 Base-TX 200 mA at + 5V DC; 500 mA at -48V Operating Non-operating Operating Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps RJ-45 in the back Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft (100 m) Category 5E (4 pair); up to 328 ft (100 m)
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 10
Page 11
QuickSpecs
Technical Specifications
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for
Specifications for
Specifications forSpecifications for ProLiant BL p-Class GbE
ProLiant BL p-Class GbE
ProLiant BL p-Class GbEProLiant BL p-Class GbE Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses
Forwarding Table
Forwarding Table
Forwarding TableForwarding Table Age Time
Age Time
Age TimeAge Time Memory
Memory
MemoryMemory Compliance
Compliance
ComplianceCompliance
Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector
Cable Support
Cable Support
Cable SupportCable Support
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Operating Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Height Width Depth
11.5 lb/5.2 kg per interconnect switch
9.6 Gbps external port bandwidth per server blade enclosure (full duplex) Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per
gigabit port, (64-byte packets) Non-blocking, full-wire speed for all connections Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 8,191 per interconnect switch; MAC address based filtering and MAC
address packet priority configuring Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,
802.1p, 802.3ac, 802.3ad (Static), and 802.1Q SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC
2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps
IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC
854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC
2131) and ZModem, 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A
82.4° F (28° C)
101.7° F (38.7° C)
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 11
Page 12
QuickSpecs
Technical Specifications
Safety
Safety
SafetySafety
Power Requirements
Power Requirements
Power RequirementsPower Requirements Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating specifications
Operating specifications
Operating specificationsOperating specifications for McDATA 4Gb SAN
for McDATA 4Gb SAN
for McDATA 4Gb SANfor McDATA 4Gb SAN Switch
Switch
SwitchSwitch
Fibre Channel ports
Fibre Channel ports
Fibre Channel portsFibre Channel ports Performance
Performance
PerformancePerformance Certified maximum
Certified maximum
Certified maximumCertified maximum Switch core
Switch core
Switch coreSwitch core Fabric latency
Fabric latency
Fabric latencyFabric latency Maximum frame size
Maximum frame size
Maximum frame sizeMaximum frame size Classes of service
Classes of service
Classes of serviceClasses of service Port types
Port types
Port typesPort types Data traffic types
Data traffic types
Data traffic typesData traffic types Media types
Media types
Media typesMedia types Laser
Laser
LaserLaser
Options
Options
OptionsOptions Supported software
Supported software
Supported softwareSupported software Management access
Management access
Management accessManagement access Diagnostics
Diagnostics
DiagnosticsDiagnostics Dimensions
Dimensions
DimensionsDimensions
Temperature
Temperature
TemperatureTemperature
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
UL/CUL Listed Accessory CE
-48VDC: 1050 mA, 50 W maximum (per interconnect switch) Operating Non-operating Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
2 external ports (ships with two 4Gb SFPs) 4 GB/sec line speed, full duplex 24 switches, 7 hops; larger fabrics certified as required Non-blocking <2 µ sec. with no contention, cut-through routing 2112-byte payload Class 2, Class 3, Class F (inter-switch frames) FL_Port, F_Port, and E_Port; self-discovery based on G_Port or GL_Port Fabric switches support unicast, multicast (256 groups), and broadcast Small Form-Factor Pluggable (SFP) Short-wave up to 500 m (1,640 ft); long-wave up to 10 km (6.2 mi) when
available SFP media-take out SANtegrity Enhanced Software 10/100 Ethernet (RJ-45) POST and embedded online/offline diagnostics Height
Height
HeightHeight Width
Width
WidthWidth Depth
Depth
DepthDepth Weight
Weight
WeightWeight Operating
Operating
OperatingOperating
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
3.4 in (8.6 cm)
1.5 in (3.8 cm)
4.75 in (12.1 cm) 7 in (17.9 cm) with handle
1.94 lbs (.88 kg) 32° to 104° F (0° to 40° C)
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 12
Page 13
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for GbE2
Specifications for GbE2
Specifications for GbE2Specifications for GbE2 Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses Forwarding Table
Forwarding Table
Forwarding TableForwarding Table Age Time
Age Time
Age TimeAge Time Memory
Memory
MemoryMemory Compliance
Compliance
ComplianceCompliance
Network Transfer
Network Transfer
Network TransferNetwork Transfer Rate
Rate
RateRate
Connector
Connector
ConnectorConnector
EMI
EMI
EMIEMI
Safety
Safety
SafetySafety
Power
Power
PowerPower Requirements
Requirements
RequirementsRequirements
Temperature
Temperature
TemperatureTemperature Range
Range
RangeRange Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb
Wet Bulb
Wet BulbWet Bulb Temperature
Temperature
TemperatureTemperature
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Height Width Depth
12.0 lb/5.4 kg per interconnect switch 24 Gbps External port bandwidth per server blade enclosure (full duplex) Forwarding rate 1.5 million pps per gigabit port (64-byte packets) Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 2,048 per interconnect switch Maximum age: 1 to 65535 seconds; default: 300 seconds
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D,
802.3ac, 802.3ad (Static), and 802.1Q SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface
Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps
RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem
10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE 48VDC: 2040 mA, 98 W maximum (per interconnect switch without Storage
Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit)
Operating Non-operating Operating Non-operating Operating Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 13
Page 14
QuickSpecs
Technical Specifications
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for
Specifications for
Specifications forSpecifications for CGESM
CGESM
CGESMCGESM Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
NOTE:
NOTE:
NOTE: NOTE: sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses Memory
Memory
MemoryMemory Compliance
Compliance
ComplianceCompliance
Network Transfer
Network Transfer
Network TransferNetwork Transfer Rate
Rate
RateRate
Connector
Connector
ConnectorConnector
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
Height Width Depth
11.5 lb/5.2 kg per interconnect switch 28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding
Rate (64 Byte Packets) 9018Bytes Jumbo Frames MTU Non-blocking architecture. Wire Speed Performance on all ports Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 8000 MAC/physical address Table Size 128MB DRAM Memory. 16MB Flash Memory IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full
duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE
802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-
MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION­MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS­MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE­RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH­MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO­SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB
1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9
10.405 in (26.43 cm)
1.6 in (4.06 cm) 28 in (71.12 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 14
Page 15
QuickSpecs
Technical Specifications
EMI
EMI
EMIEMI
Safety
Safety
SafetySafety
Power
Power
PowerPower Requirements
Requirements
RequirementsRequirements Temperature
Temperature
TemperatureTemperature Range
Range
RangeRange Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb
Wet Bulb
Wet BulbWet Bulb Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE: sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect ComponentsHP BladeSystem p-Class Interconnect Components
FCC Part 15 Class A EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC
AS/NZS 3548 Class A CE VCCI Class A UL to UL 60950, Third Edition
C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI
CE Marking
-48VDC: 1050 mA, 125 W maximum (per interconnect switch)
Operating Non-operating Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Environment-friendly
Environment-friendly
Environment-friendlyEnvironment-friendly Products and Approach
Products and Approach
Products and ApproachProducts and Approach
© Copyright 2007 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
End-of-life Management
End-of-life Management
End-of-life ManagementEnd-of-life Management and Recycling
and Recycling
and Recyclingand Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to
http://www.hp.com/go/green http://www.hp.com/go/green
Products returned to HP will be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.
http://www.hp.com/go/green
. To recycle your product, please go to: or contact your nearest HP sales office.
. These instructions may
DA - 12331 Worldwide — Version 4 — September 12, 2007