Your Honeywell security system is designed for use with devices manufactured or approved by
Honeywell for use with your security system. Your Honeywell security system is not designed for
use with any device that may be attached to your security system's keypad or other
communicating bus if Honeywell has not approved such device for use with your security system.
Use of any such unauthorized device may cause damage or compromise the performance of your
security system and affect the validity of your Honeywell limited warranty. When you purchase
devices that have been manufactured or approved by Honeywell, you acquire the assurance that
these devices have been thoroughly tested to ensure optimum performance when used with your
Honeywell security system.
– 2 –
TABLE OF CONTENTS
SYSTEM OVERVIEW ....................................5
General .......................................................5
A Partitioned System ..................................6
INDEX ..........................................................78
– 4 –
General
System Overview
Your Honeywell security system consists of a main control panel, at least one
keypad, and various sensors strategically positioned throughout the
premises. The system offers you three forms of protection: burglary, fire and
emergency. The keypad provides full control of system operation.
The system uses microcomputer technology to monitor all protection zones
and system status and provides appropriate information for display on the
keypad(s) used with the system, and initiates appropriate alarms. Your
system may also have been programmed to automatically transmit alarm or
status messages over the phone lines to a central alarm monitoring station.
This manual is designed to help you become comfortable operating
your system. Each function is explained in step-by-step detail. We
recommend you read the SYSTEM OVERVIEW section to become
familiar with the terminology and the basic features of the system.
NOTE: All references in this manual for number of zones, number of
user codes, number of access cards, and the event log capacity, use
the VISTA-250BP’s features. The following table lists the differences
between the VISTA-128BP/128SIA and the VISTA-250BP control
panels. Additionally, only the VISTA-128BP/128SIA supports the
capability to have a device duplicate keypad sounds at a remote
location. All other features are identical for both panels.
Feature VISTA-128BP/128SIA VISTA-250BP
Number of Zones 128 250
Number of User Codes 150 250
Number of Access Cards 250 500
Event Log Capacity 512 1000
VistaKey Modules 8 15
– 5 –
System Overview (cont’d)
A Partitioned System
Simply stated, a partitioned system shares one physical alarm system among
different users, each with their own requirements. For the most part, you as
a user need not know about other users and their structure in the system,
but from time to time, you may see display messages that indicate the system
is in use by another user. Do not be concerned, this is normal. Refer to the
ACCESSING OTHER PARTITIONS section for additional information.
Panel Linking
Panel Linking networks up to eight VISTA-128BP/VISTA-250BP control
panels, enabling a user to control the features of all control panels from a
single location. The Panel Linking is ideal for multi-building environments
(e.g. a shopping mall, college campus, etc.).
The system provides the following three modes to access other “linked”
control panels:
•Single-Partition, Single-Panel − displays status of a partition on a remote
control panel and allows control of that remote control panel.
•Multi-Partition, Multi-Panel Mode − displays status and allows
arming/disarming of multiple partitions at once on a remote control
panel.
•Multi-Panel View Mode − displays status and allows arming/disarming of
multiple remote control panels at a time.
Zones
Your system's sensing devices have been assigned to various "zones." For
example, the sensing device on your Entry/Exit door may have been assigned
to zone 001, sensing devices on windows in the master bedroom to zone 002,
and so on. These numbers will appear on the display, along with an alpha
descriptor for that zone (if programmed), when an alarm or trouble condition
occurs.
Fire Protection
The fire protection portion of your security system (if used) is always on and
will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM
SYSTEM section for important information concerning fire protection, smoke
detectors and planning emergency exit routes from your house.
– 6 –
Burglary Protection
The burglary protection portion of your system must be turned on or "armed"
before it will sense burglary alarm conditions. Your system provides four
modes of burglary protection: STAY, AWAY, INSTANT and MAXIMUM, and
even allows you to BYPASS selected zones of protection while leaving the
rest of the system armed. The system also provides a CHIME mode, for
alerting users to the opening and closing of doors and windows while the
system is disarmed. Refer to the other sections of this manual for procedures
for using these features.
The following table lists the four different arming modes and the results of
each.
System Overview (cont’d)
Arming
Mode
AWAY Yes Yes Yes
STAY✳ Yes Yes Yes
INSTANT✳ Yes No Yes
MAXIMUM Yes No Yes
✳The system provides three different STAY and INSTANT arming modes. See
ARMING IN THE STAY MODES and ARMING IN THE INSTANT MODES
sections for details on these modes.
Carbon Monoxide Protection
Carbon monoxide (CO) protection is available with your system using the
5800CO Carbon Monoxide Detector. The 5800CO is a 3V battery powered
wireless Carbon Monoxide Detector used with wireless alarm systems that
support 5800 series devices. Carbon monoxide gas is a highly poisonous gas
which is released when fuels are burned. It is invisible, has no smell and is
therefore impossible to detect with the human senses. We strongly suggest
installing Carbon monoxide protection with your system.
Alarms
When an alarm occurs, both the keypad and external sounders will sound,
and the keypad will display the zone(s) causing the alarm. If your system is
connected to a central monitoring station, an alarm message will also be sent.
To stop the alarm sounding, simply disarm the system.
Features For Each Arming Mode
Exit
Delay
Entry
Delay
Perimeter
Armed
– 7 –
System Overview (cont’d)
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the
zone(s) that caused the problem, and displays the type of alarm (ex. FIRE,
ALARM). It remains displayed until it is cleared by disarming the system
(see DISARMING THE SYSTEM section).
Speed Key (Macros)
The system can store a string of up to 32 keystrokes, which can be activated
anytime by simply pressing the “A, B, C, or D” keys. This feature can be
used to make it easy to perform multiple functions at once (such as going to
another partition to bypass a zone), or it can be used to simplify an everyday,
repeated procedure. Refer to the SPEED KEY section for procedures for
using this feature.
Using Schedules
Your system may have been programmed with schedules for automatically
arming, disarming and activating various devices and/or performing other
system functions at predetermined times. Users can modify some of these
schedules by manually delaying a closing time, using temporary schedules, or
by programming special user schedules. Refer to the USING SCHEDULES
section at the end of this manual for scheduling related procedures.
Device Timers
The system provides up to 20 "timers" that can be used to control various
devices, such as lights or appliances. These timers are similar in concept to
the individual appliance timers that might be purchased at a department
store. The devices that can be controlled are programmed into the system by
the installer. Up to 96 of these devices can be programmed. Refer to the
PROGRAMMING DEVICE TIMERS section for procedures.
To Access another Partition (GOTO Command)
Each keypad is assigned a default partition for display purposes, and will
show only that partition's information. But, if the user is authorized, a
keypad in one partition can be used to perform system functions in another
partition, by using the GOTO command. Note that only those partitions
authorized and programmed by the installer can be accessed in this manner.
To GOTO another partition, enter your security code, then press [✳] followed
by the desired partition number (1-8).
The keypad will remain in the new partition until directed to go to another
– 8 –
System Overview (cont’d)
partition, or until 2 minutes has elapsed with no keypad activity. Entering
your security code, pressing [✳ ] followed by [0] will return the keypad to its
original partition.
Master Keypad Operation
A "Master" keypad is one on which the status of all eight partitions is
displayed simultaneously. A user can get more information about a certain
partition by simply entering [✳ ] + the desired partition number (1-8). To log
on to the "Master" partition (9) using the GOTO command, and to perform
any functions at a Master keypad, a user must have access to all partitions.
Self-Help Feature
Abbreviated user's instructions are built into the system that can be easily
viewed on the alpha keypad's message display screen. This feature will prove
particularly useful if this manual is not conveniently accessible when you
need to perform a system procedure with which you are not familiar.
To view the abbreviated instructions:
Simply press and hold down the function key of interest until the description
starts to appear (about 5 seconds) and then release it. The system must be
“READY TO ARM” to perform this function.
Refer to the FUNCTIONS OF THE KEYPAD section for descriptions of each
key function.
Phone Access & Voice Response Capability
Your system may include a 4286 VIP module that will permit you to access
the system via a Touch-tone phone, either on-premises or by call-in when
away. The phone access feature will enable you to do the following:
•Receive synthesized voice messages over the telephone regarding the
status of the security system.
•Arm and disarm the system and perform most function commands via
the telephone, with voice confirmation provided after each command
entry.
•Control 4204/4204CF relays devices and lights and appliances through
the #70 Manual Relay Activation mode.
Complete information regarding the use of this feature is provided in a
separate manual entitled PHONE ACCESS USER GUIDE, which
accompanies the 4286 VIP module.
– 9 –
About The Keypads
General
IMPORTANT: If the keypad beeps rapidly upon entering the
premises, it indicates that an alarm has occurred during your
absence. LEAVE IMMEDIATELY and CONTACT THE POLICE
Your keypads allow you to control all system functions. The keypads feature
a telephone style (digital) keypad and a Liquid Crystal Display (LCD) that
shows the nature and location of all occurrences. Keypad display back
lighting is programmable to always stay on or to light only when a key is
pressed, then turn off a few minutes later.
The keypads also feature a built-in sounder that will sound during alarms
and troubles. It will also "beep" during certain system functions, such as
during entry/exit delay times, during CHIME mode, and when depressing
keys to perform system functions (to acknowledge the key press). These
sounds can be optionally suppressed in some of your keypads (so as not to
disturb other users of the system). Ask your installer if this has been done.
The Alpha Keypad
Alpha keypads feature a 2-line, 32 character alphanumeric Liquid Crystal
Display (LCD) that can display system messages in user-friendly English.
Abbreviated user's instructions can also be displayed (see Self Help
paragraph in the SYSTEM OVERVIEW section). These keypads can also be
programmed with custom zone descriptors.
from a safe location nearby.
– 10 –
SPEAKER
Functions of the Keypad
LCD
DISPLAY
ARMED
A
OFF
1
AWAY
2
STAY
3
LEDS
READY
B
C
D
4
7
MAX
INSTANT
READY
TEST
5
CODE
8
0
6
9
#
BYPASS
CHIME
FUNCTION
KEYS
IMPORTANT! When using the keypad to enter codes and commands,
sequential key depressions must be made within 3 seconds of one
another. If 3 seconds elapses without a key depression, the entry is
aborted and must be repeated from its beginning.
6160-00-002-V1
– 11 –
Functions of the Keypad (cont’d)
ALPHA DISPLAY WINDOW: A 2-line,
32-character Liquid Crystal Display (LCD)
that displays protection point
identification and system status, messages,
and user instructions.
1 OFF
the system, silences alarms and audible
trouble indicators, and clears visual alarm
trouble after the problem has been
corrected.
2 AWAY
perimeter and interior burglary protection
by sensing an intruder's movements
through protected interior areas as well as
guarding protected doors, windows, etc.
Late arrivals can enter through an entry
delay zone without causing an alarm if the
system is disarmed before the entry delay
time expires.
3 STAY
protection, guarding protected doors,
windows and other perimeter protection
points, and sounds an alarm if one is
opened. Also allows automatic bypassing of
certain areas which permits movement
within your house without causing an
alarm. Late arrivals can enter through an
entry delay zone without causing an alarm
if the system is disarmed before the entry
delay time expires. See ARMING PERIMETER ONLY for a full explanation
of the STAY key.
: Disarms the burglary portion of
: Completely arms both
: Arms the perimeter burglary
4 MAXIMUM
to AWAY mode, but eliminates the entry
delay period, thus providing maximum
protection. An alarm will occur
immediately upon opening any protection
point, including entry delay zones.
5 TEST
sounder if disarmed.
6 BYPASS
protection zones from being monitored by
the system. Displays previously bypassed
protection zones.
7 INSTANT
to STAY mode, but turns off the entry
delay period, offering greater security
while inside and not expecting any late
arrivals. An alarm will occur immediately
upon opening any perimeter protection
point, including entry delay zones.
8 CODE
user codes that can be given to other users
of the system.
: Arms in manner similar
: Tests the system and alarm
: Removes individual
: Arms in manner similar
: Allows the entry of additional
– 12 –
Functions of the Keypad (cont’d)
9 CHIME : Turns on & off the CHIME
mode. When on, any entry through a
protected delay or perimeter zone while the
system is disarmed will cause a tone to
sound at the Keypad(s).
✳ READY
arming the system, the keypad will display
all open protection zones within the
keypad's home partition. This key is also
used to display all zone descriptors that
have been programmed for your system, by
holding the key down for at least 5 seconds.
: Permits ARMING of the system
#
without use of a security code ("Quick
Arm", if programmed).
: When depressed prior to
KEYS 0-9: Used to enter your individual
security access code(s).
LED READY INDICATOR: (GREEN) Lit
indicates system is ready to be armed,
while unlit indicates system not ready.
LED ARMED INDICATOR: (RED) Lit
when the system has been armed (STAY,
AWAY, INSTANT or MAXIMUM).
SPEAKER: Source of audible internal
warning and confirmation sounds, as well
as alarms (see "Summary of Audible
Notifications").
FUNCTION KEYS: These keys can be
used for Speedkey (macros) functions or
panic keys. Refer to the SPEEDKEY
(MACROS) and PANIC KEYS sections for
descriptions of these functions.
–13 –
Entry/Exit Delays
General Information
Your system has installer-programmed time delays, known as exit delay and
entry delay. Whenever you arm your system, exit delay gives you time to
leave through the designated exit door without setting off an alarm. Exit
delay begins immediately after entering any arming command, and applies to
all modes of arming protection. If programmed, a slow beeping will sound
throughout the exit delay period.
Entry Delay gives you time to disarm the system when you reenter through
the designated entrance door. But the system must be disarmed before the
entry delay period ends, or an alarm will occur. The keypad will beep during
the entry delay period, reminding you to disarm the system. You can also
arm the system with no entry delay at all by using either INSTANT or
MAXIMUM arming modes. These modes provide greater security while on
the premises or while away for extended periods of time. See your installer
for your delay times.
– 14 –
General Information
At the time of installation, you were assigned an authority level and a
personal four-digit security code, known only to you and yours. The security
code must be entered when arming and disarming the system. The authority
level defines the system functions that you can perform.
As an additional safety feature, other users that do not have a need to know
your code can be assigned different security codes, and each user can be given
a different authority level. Users are identified by "user numbers", which are
assigned when assigning a user's security code.
All codes can be used interchangeably when performing system functions
within the limits of each code's authority level (a system armed with one
user's code can be disarmed by another user's code), with the exception of the
Operator Level C code. See AUTHORITY LEVELS on the following page for
details regarding authority levels.
Important: Only users assigned for user numbers 001-050 can perform
panel linking functions.
Duress Code
This feature is intended for use if you are forced to disarm or arm the system
under threat. When used, the system will act normally, but can silently
notify the central station of your situation, if that service has been provided.
The duress code is pre-assigned by the installer during installation (authority
level 6).
Important: This code is useful only when the system is connected to a
central station.
Quick Arming
Note that if "Quick Arming" was programmed by the installer, the [#] key
can be pressed in place of the security code when arming the system. The
security code must always be used to disarm the system, however.
Security Codes and Authority Levels
– 15 –
Security Codes and Authority Levels (cont’d)
Authority Levels
Authority levels define the system functions a particular user can perform.
Depending on the authority assigned to you, there are certain system
functions you may be prohibited from performing. In summary, there are six
authority levels, each having certain system restrictions as shown below.
Level 1 Master:Can perform all system functions in assigned
partitions, and can add, delete or change Manager
and Operator level users. Master codes are added
by the Installer.
Level 2 Manager: Can perform system functions in assigned
partitions, and can add, delete or change Operator
level users.
Level 3 Operator A: Can perform system functions in assigned
partitions, but cannot add or delete other users.
Level 4 Operator B: Same as Operator A, except Operator B cannot
bypass zones of protection.
Level 5 Operator C: Can arm the system in assigned partitions, but
cannot disarm the system unless the system was
armed with this code. This code is typically
assigned to someone who has a need to
arm/disarm the system only at certain times (such
as a baby-sitter).
Level 6 Duress: Can arm and disarm the system, but also sends a
silent panic alarm to the central station, if that
service is connected.
To view your authority level and system capabilities:
1. Enter your code + [✳] +[✳].
2. The keypad will display the partition(s) that you are authorized to
operate, and your user number and authority level in each partition.
– 16 –
Security Codes and Authority Levels (cont’d)
General Rules on Authority Levels and Changes
•A user may not delete or change the user code of the SAME or HIGHER
authority than which he is assigned.
• A user may only ADD users to a LOWER authority level.
• A user may assign access codes only to those partitions to which the user
adding the code has access. (Ex. a user with access to only partition 1
cannot assign codes in partition 2.)
•The only way to assign a user's authority level is by using the "Add a
User" procedure. To change a user's authority level, that user must first
be deleted, and then added again.
•A user can only be DELETED or CHANGED from within the partition he
is assigned.
•User numbers must be entered as 3-digit entries. Single digit user
numbers must be preceded by a "00" (example, 003, 004, etc.). Security
codes are entered as 4-digit numbers.
•Before assigning a security code, be sure it does not conflict with any
DURESS code.
Note: When adding, changing or deleting users, all other alpha keypads in
that partition will display "User Edit Mode – Please Stand By", and key
depressions (except Panic) at those keypads will be ignored. Panic key
depressions will cause an alarm and terminate user entry.
To Exit User Edit Mode
You can exit any of the user edit modes described on the following pages at
any time by doing the following:
1. Press either ✳
2. System returns to normal mode.
or # , or don't press any key for 10 seconds.
– 17 –
Security Codes and Authority Levels (cont’d)
To Add a User
IMPORTANT: Temporary users should not be shown how to use any system
function they do not need to know (e.g. bypassing protection zones).
CODE
1. Enter Master or Manager code and press the 8
2. Enter the new user's 3-digit User Number (002-250).
3. Enter 4-digit security code for that user. The following prompts will
appear.
ADD NEW USER?
0 = NO , 1 = YES
Enter 1 to add a new user code. Entering 0 will
change the existing user's code to the code entered
in step 3. See Changing A User's Code section.
key.
USER NUMBER = 003
ENTER AUTH. LEVEL
GROUP BYPASSING?
0 = NO , 1 = YES
ACCESS GROUP?
ENTER 0-8
RF BUTTON ?
0 = NO , 1 = YES
ENTER BUTTON ZN #
(001-250)
Enter the authority level, 1-6, for this user within
this partition.
1=master 2=manager 3=operator A
4=operator B 5=operator C 6=duress code
Enter 1 (YES) to allow this user to perform group
bypasses. Enter 0 (NO) this user will not be able to
perform group bypasses.
If access schedules have been programmed, this
prompt appears. Enter the user's access group
number (1-8) if this user should have limited
access to the system. Enter 0 if no access group
should be assigned.
This prompt will appear if a 5800 series button
transmitter has been supplied and has not yet been
assigned to a user. Press 1 if a button transmitter
will be assigned to this user. Otherwise press 0.
If assigning a button transmitter, this prompt will
appear. Enter the button's zone number (see your
installer for zone number).
– 18 –
Security Codes and Authority Levels (cont’d)
MULTI-ACCESS ?
0 = NO , 1 = YES
GLOBAL ARM ?
0 = NO , 1 = YES
PART.2 - SHOP?
0 = NO , 1 = YES
XMIT USER DATA?
0 = NO , 1 = YES
INDV USER PGM
1 = YES 0 = NO
If you as a user have access to other partitions, the
keypad will prompt for ability of this new user to
access (GOTO) those partitions. Press 0 (NO) or 1
(YES). If no, the system activates this user code and
exits “Add a User” mode. If yes, the keypad prompts
for the Global Arm option for this user.
Press 1 (YES) if this user will be allowed to try to
arm more than one partition at the same time.
Press 0 if this user will arm only his assigned
partition.
The keypad now prompts for the user’s access to the
next partition (see GOTO command). Again press 0
or 1. If yes, the system will automatically assign a
user number for use in that partition and will
prompt for authority level and global arm options
for this user within the partition (see previous
steps).
If the user number is from 001-050 this prompt
appears. Answer YES (1) to have the system send
the user’s attributes to all the other control panels
that are “linked” to this control. If you answer NO
(0), the system displays the following prompt on the
next page.
Answer YES (1) to link to another control panel and
manually enter the user into partition(s) in that
control panel. If you answer NO (0), the system
scrolls through each partition displaying a
summary of the user’s attributes in each partition
(see next prompt).
– 19 –
Security Codes and Authority Levels (cont’d)
PART. 1 A0* WHSE
USER 003 AUTH=3G.
To Change a User's Code
CODE
1. Enter Master or Manager code and press the 8 key + user number
to be changed.
2. Enter the new code for that user.
ADD NEW USER?
0 = NO , 1 = YES
USER 002 CHANGED
SUCCESSFULLY
When all partitions have been displayed, the
keypad will scroll through the partition(s) to which
access has been assigned, and will display the user
number, authority level and global arm option for
each. The “G” after the authority level indicates
that the global arm feature is active for this user in
the displayed partition. The "*" indicates the
partition from which this user can be changed or
deleted. The "." at the end of the second line
indicates that this user sends open/close reports.
Open/close reporting is automatically active for any
users added by you, if you have open/close reporting
active.
The system will recognize that the user number is
already in use and will prompt whether or not this
is a new user. Enter 0 to change the existing
user's code to the code entered in step 3.
The system will confirm that the change is allowed
based on authorization level, and if so, will put the
new code into effect.
Note that if changing one’s own code, the
system will prompt for the new code to be reentered. This prevents accidentally changing one's
own code.
– 20 –
Security Codes and Authority Levels (cont’d)
To Delete a User
CODE
1. Enter Master or Manager code and press the 8 key + user number
to be deleted.
2. Enter Master or Manager code first entered.
OK TO DELETE
0 = NO , 1 = YES
USER CODE
DELETED
The system will recognize that the User number
is already in use and will prompt to confirm that
it should be deleted. Press 0 (NO) or 1 (YES).
If yes, that user's code will be removed from all
partitions to which it was assigned, and all
authorization levels and other information about
that user will be deleted. Note that a user can
only be deleted from the partition in which it was
first assigned, and can only be deleted by a user
with a higher authority level. A User's security
code cannot be deleted by oneself.
– 21 –
Accessing Other Partitions
To Access another Partition
Each keypad is assigned a default partition for display purposes, and will
show only that partition's information. But, if the user is authorized, a
keypad in one partition can be used to perform system functions in other
partitions by using the GOTO command. Note that only those partitions
authorized and programmed by the installer can be accessed in this manner.
To GOTO another partition:
READY
1. Enter your security code, then press ✳ + partition number (0-8).
Entering partition number 0 will return the keypad to its original
partition.
2.
Global Arming
The Global Arming option may be assigned for use by some users. If Global
Arming was enabled for use with your security code, a keypad prompt
(message) shown below appears after pressing one of the arming function
keys (STAY, INSTANT, AWAY, MAXIMUM, OFF).
LOG-ON TO AAAA
PART. X COMPLETE
The keypad will remain in the new partition
until directed to go to another partition, or
until 2 minutes has elapsed with no keypad
activity.
AAAA = alpha descriptor programmed by the
installer
X = partition number
– 22 –
ARM P 1 2 3 4 5 6 7 8
HIT 0-8 X X X - - X - -
The prompt displays all the partitions. The user
may only arm/disarm the partitions they are
assigned access to.
To select the partition(s) that are to be armed,
enter the desired number 1-8. An "X" will appear
under that partition. Entering a partition's
number again will delete the “X” and that
partition will not arm when this prompt is exited.
Pressing 0 will turn all partitions the user is
assigned access to on/off.
When completed, press ✳ to exit. All the partitions
with the “X” will then arm/disarm.
Accessing Other Partitions (cont’d)
Global Arming Notes:
•When performing a Global Arm, if there are faults in any of the selected
partitions, the system will enter a Summary Mode. Faulted zones in all
the selected partitions will be displayed. These faults must be corrected
or bypassed. This Summary Mode will end in approximately 120 seconds
if no keys are pressed.
•When performing a Global Disarm, if any of the selected partitions has a
condition which would cause the keypad to beep (e.g., alarm memory or a
trouble condition), the system enters a Summary Mode and displays the
condition. This Summary Mode will end in approximately 120 seconds if
no keys are pressed.
Master Keypad Operation
A "Master" keypad is one that reflects the status of the entire system
(Partitions 1-8) on its display. This is useful because it eliminates the need
for a security officer in a building to have to "log-on" to various partitions
from one partition's keypad to find out where an alarm has occurred.
A description of a typical display follows:
SYSTEM 1 2 3 4 5 6 7 8
STATUS R R N N A T ✴ B
The status of each partition is directly below the partition number on the
display. Possible status indications include:
A = Armed Away S = Armed Stay M = Armed Maximum
I = Armed Instant R = Ready N = Not Ready
B = Bypassed/Ready ✴ = Alarm T = Trouble
F = Fire Alarm P = AC Power Failure L = Low System Battery
C = Comm Fail
To obtain more information regarding a particular partition, enter [✴] +
[Partition No.] (i.e., ✴4). This will allow viewing only of that partition. In
order to affect that partition, the user must log on with a code that has access
to that partition. Also, in order for a user of any partition to log onto the
"Master" partition (Partition 9) to view the status of all partitions, and to
perform any functions at the Master keypad, that user must have access to
all partitions. Otherwise, access will be denied.
– 23 –
Accessing Other Partitions (cont’d)
The following is an example of what would be displayed for a fault condition
on Zone 002 (Loading Dock Window) on Partition 1 (Warehouse) when
logging on from a keypad on Partition 9:
WHSE DISARMED
HIT ✴ FOR FAULTS
This is the normal display that appears at Partition 1's keypad(s). Pressing ✴
will display:
FAULT 002 LOADING
DOCK WINDOW
Additional zone faults will be displayed one at a time. To display a new
partition's status, press ✴ + [Partition No.]. This will display the status of
the new partition.
The "Armed" LED on a Master keypad will be lit only if all partitions have
been armed successfully. The "Ready" LED will be lit only if all partitions
are "ready to arm."
The sounder on a Master keypad will reflect the sound of the most critical
condition on all of the partitions. The priority of the sounds is as follows:
– 24 –
A. Pulsing fire alarm sounds
B. Steady burglar alarm sounds
C. Trouble sounds
The sounder may be silenced by pressing any key on the Master keypad.