Honeywell TP971 Catalog Page

Pneumatic Thermostats
TP971A OR TP9610A
DAY 13 PSI (90 kPa)
NITE 18 PSI (124 kPa)
M B
N.O.
M
HOT WATER OR STEAM SUPPLY
C3540 1
TP971 Pneumatic Day/Night Thermostat
Pneumatic thermostat with night setback used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems. Replacement kits are available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell two-pipe pneumatic thermostats.
• Direct Acting (DA) and Reverse Acting (RA) models are available.
• Three-pipe thermostats are available for unit ventilator applications where the outdoor damper must operate when the thermostat is manually set to day operation.
• Adapter plate in thermostat kits covers existing thermostat watermark.
• Backplate has molded air connections-no separate fittings needed.
• Universal Locking cover with satin chrome finish and horizontal, vertical, or blank window options-other covers available.
TP971 Typical Piping
Accessories:
CCT729A-Gauge Adapter for Calibration. Add 305965 0 to 30 psi gauge
for Complete Tool.
CCT735A-Thermostat Cal bration Tool includes Allen wrench for cover
installation.
305965-1-1/2 in. diameter, 1/8 NPT center stem back mount Pressure
Indicating gauge (0 to 30 psi scale) with ±4% accuracy
14002362-001-Duct Sampling Chamber 14002430-001-Thermostat Guard 14003192-001-Wallplate adapter kit. Adapts HP970 or TP970 series
thermostats to HP900 and TP900 flush mounted and TP910 series
Application Type: Wall Thermostat, Day/Night operation Dimensions, Approximate: 3 1/4 in. high x 2 in. wide x 1 5/8 in. deep
(83 mm high x 51 mm wide x 41 mm deep)
Airflow Usage: 0.011 scfm (5.2 mL/s) Mounting: Wall mount Operating Temperature: 100 F maximum
flush or surface mounted installations
14004439-001-Setpoint Extension 14004447-003-Setpoint Cam Assembly for TP971A, C, D;
TP972A1168, A2168, A2176
Replacement Parts:
14001865-001-Filter Cartridge Assembly
Storage Temperature: 150 F maximum (66 C maximum) Remote Bulb: No Setpoint: Day/Night Sensor Element: Bimetal Maximum Operating Pressure: 25 psi (170 kPa)
Number
Product Number Action
TP971A2003/U Direct
TP971A2011/U Direct
TP971A2029/U Direct
TP971A2052/U Direct
TP971A2086/U Direct
TP971A2102/U Direct
TP971B2001/U Reverse
652 customer.honeywell.com 70-6910
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
of Pipes
2 Day: 59 F to 90 F,
2 Day: 15 C to 30 C,
2 Day: 59 F to 90 F,
2 Day: 15 C to 30 C,
2 Day: 59 F to 90 F,
2 Day: 59 F to 90 F,
2 Day: 59 F to 90 F,
Setpoint Temperature Range Changeover
Night: 50 F to 80 F
Night: 10 C to 27 C
Night: 50 F to 80 F
Night: 10 C to 27 C
Night: 50 F to 80 F
Night: 50 F to 80 F
Night: 50 F to 80 F
Day 13 psi, Night 18 psi
Day 13 psi, Night 18 psi
Day 16 psi, Night 21 psi
Day 16 psi, Night 21 psi
Day 20 psi, Night 25 psi
Day 13 psi, Night 18 psi or 16-20 psi
Day 13 psi, Night 18 psi
Day 90 kPa, Night 124 kPa
Day 90 kPa, Night 124 kPa
Day 110 kPa, Night 144 kPa
Day 110 kPa, 144 kPa
Day 137 kPa, Night 172 kPa
Day 90 kPa, Night 124 kPa
Day 90 kPa, Night 124 kPa
Throttling Range
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
Includes Comments**(F) (C) (psi) (kPa) (F) (C)
Order Cover Separately
Order Cover Separately
Order Cover Separately
Order Cover Separately
Order Cover Separately
Thermostat, small wall plate and satin chrome cover.
Order Cover Separately
Convertastat Kit
Pneumatic Thermostats
Throttling Range
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
2 F to
1 C to
10 F
5 C
Includes Comments**(F) (C) (psi) (kPa) (F) (C)
Order Cover Separately
Order Cover Separately
Order Cover Separately
Order Cover Separately
Order Cover Separately
Has secondary branch line
Has secondary branch line
Has secondary branch line
Product Number Action
TP971B2019/U Reverse
TP971B2043/U Reverse
TP971C2009/U Direct
TP971C2017/U Direct
TP971C2025/U Direct
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Acting Heating, two temp.
Number of
Setpoint Temperature Range Changeover
Pipes
2 Day: 59 F to 90 F,
2 Day: 59 F to 90 F,
3 Day: 59 F to 90 F,
3 Day: 15 C to 30 C,
3 Day: 59 F to 90 F,
Night: 50 F to 80 F
Night: 50 F to 80 F
Night: 50 F to 80 F
Night: 10 C to 27 C
Night: 50 F to 80 F
Day 16 psi, Night 21 psi
Day 20 psi, Night 25 psi
Day 13 psi, Night 18 psi
Day 13 psi, Night 18 psi
Day 16 psi, Night 21 psi
Day 110 kPa, Night 144 kPa
Day 137 kPa, Night 172 kPa
Day 90 kPa, Night 124 kPa
Day 90 kPa, Night 124 kPa
Day 110 kPa, Night 144 kPa
**A Tradeline Kit includes a TP970 Series thermostat with either a Satin Chrome or Beige Universal Cover, Windows (horizontal (F), vertical (F)
and blank) for new installations or to convert newer, small size Honeywell or competitor thermostat, not requiring a wall plate adapter.
A Convertastat Kit™ includes a TP970 Series thermostat with either a Satin Chrome or Beige Universal Cover, Windows (horizontal (F), vertical (F) and blank) and a small Universal Wall Plate Adapter to convert newer, small size Honeywell or competitor thermostats.
A Modernization Kit includes a TP970 Series thermostat with Satin Chrome Universal Cover, Windows (horizontal (F), vertical (F) and blank) and a large Universal Wall Plate Adapter to convert older thermostats.
Pneumatic
70-6910 653
Controls
Loading...