Operating
Manual
FocusPROTM TH6000 Series
Programmable Thermostat
69-1921ES
Quick Reference Card
Grasp and pull to see basic operating instructions at a glance.
Battery Holder
Press down and pull to remove batteries.
Batteries should be replaced once a year (see page 17).
This manual covers the following models:
TH6110D: For 1 Heat/1 Cool systems TH6220D: For up to 2 Heat/2 Cool systems TH6320U: For up to 3 Heat/2 Cool systems (Remove battery holder to find model number)
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions.
® U.S. Registered Trademark. Patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved.
FocusPROTM TH6000 Series
Table of contents |
|
About your new thermostat |
|
Thermostat features................................... |
2 |
Programming at a glance........................... |
3 |
Quick reference to controls....................... |
4 |
Quick reference to display......................... |
5 |
Programming & Operation |
|
Set time and day........................................ |
6 |
Select fan setting (auto/on)........................ |
7 |
Select system setting (heat/cool).............. |
8 |
Using program schedules.......................... |
9 |
Program schedule overrides.................... |
12 |
Auto-changeover (heat/cool)................... |
14 |
Compressor protection............................ |
15 |
Adaptive Intelligent Recovery™.............. |
16 |
Appendices |
|
Battery replacement................................. |
17 |
In case of difficulty................................... |
18 |
Customer assistance................................ |
20 |
Accessories/replacement parts............... |
20 |
5-year limited warranty............................ |
21 |
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go.
See page 3 to check settings.
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Operating Manual
About your new thermostat
Congratulations on the purchase of your new Honeywell thermostat. It has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
Features
•Separately programmable weekday/weekend schedules.
•One-touch temp control overrides program schedule at any time.
•EnergyStar® compliant to greatly reduce your heating/cooling expenses.
•Large, clear, backlit display is easy to read — even in the dark.
•Displays both room temperature and temperature setting.
•Removable battery holder for fast, easy replacement.
•Built-in compressor protection.
FocusPROTM TH6000 Series
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed:
1. |
Set time and day (required for proper operation) |
.........................See page 6 |
2. |
Select fan setting (Auto/On): Preset to Auto................. |
To change, see page 7 |
3. |
Select system setting (Heat/Cool): Preset to Heat....... |
To change, see page 8 |
4.Program schedules: Preset to energy-saving levels while you’re at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to
bed at 10 pm) |
................................................................To change, see pages 9-11 |
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 12-13).
Operating Manual
Quick reference to controls
Digital display (see page 5).
Function Buttons
Press to select the function displayed just above each button. (Functions change depending on the task.)
Battery holder (see page 17).
Temperature Buttons
Press to adjust temperature settings (see page 11-13).
Hold Button
Press to override programmed temperature control (see page 13).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FocusPROTM TH6000 Series |
|
|
|
|
|
|
|
||||||||||
Quick reference to display screen |
|
|
|
|
|
||||||||||
Current inside temperature |
Low battery warning |
|
Current time/day |
||||||||||||
|
|
|
(see page 17) |
|
|
|
|
|
(see page 6) |
||||||
In Recovery |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperature setting |
Inside |
|
|
|
|
|
|
|
|
|
Heat |
|
||||
(see page 16) |
|
Replace Battery |
|
|
|||||||||||
|
|
|
(see pages 11-13) |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Setting |
|
||
Current program period |
|
|
|
|
In Recovery |
|
|
|
|
|
Auxiliary heat |
||||
72 6:30AM |
|
72 |
|
(Only for heat pumps |
|||||||||||
Wake/Leave/Return/Sleep |
|
|
|||||||||||||
|
Auxiliary |
|
with auxiliary heat) |
||||||||||||
(see pages 9-11) |
Wake |
|
|
|
Wed |
|
|
Heat On |
|
System status |
|||||
|
|
|
|
|
Fan |
System |
|
||||||||
|
Set Clock/Day/ |
Auto |
|
|
Heat |
|
Heat On/Cool On (If |
||||||||
Set Clock/Day/Schedule |
|
Schedule |
|
|
|
|
|
|
|
|
|
|
flashing, see page 15) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
System setting |
|
(see pages 6 & 11) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat/Cool/Auto/Off/Em |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Function buttons |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat (see page 8) |
Press the button beneath each function to |
|
|
|
|
|
|
|
|
|
|
|
Fan setting |
|||
view or change settings (functions change |
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
Auto/On (see page 7) |
||||
depending on the task) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating Manual
Set the time and day
Press SET CLOCK/DAY/SCHEDULE, then adjust time
4:30 PM
Set Clock/Day/ |
Fan |
System |
Auto |
Heat |
|
Schedule |
|
|
Press SET DAY, then select current day
Wed
Done
Set Day Set Schedule
1.Press the SET CLOCK/DAY/SCHEDULE button, then press σ or τ to set the clock time.
2.Press the SET DAY button, then press σ or τ to select the day of the week.
3.Press DONE to save & exit.
Note: If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or RUN SCHEDULE.
Note: If the display flashes Set Clock, the thermostat will follow your settings for the weekday “Wake” time period until you reset the time and day.
FocusPROTM TH6000 Series
Select the fan setting
Set Clock/Day/ |
|
Fan |
|
System |
||
|
Auto |
|
Heat |
|
||
Schedule |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Set Clock/Day/ |
|
Fan |
|
|
System |
|
|
|
On |
|
Heat |
|
|
Schedule |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press the FAN button to select Auto or On.
In “Auto” mode (the most commonly used setting), the fan runs only when the heating or cooling system is on. If set to “On,” the fan runs continuously. Use this setting for improved air circulation, or for more efficient air cleaning.
Operating Manual
Select the system setting
Set Clock/Day/ |
Fan |
System |
Auto |
Heat |
|
Schedule |
|
|
Set Clock/Day/ |
Fan |
System |
Auto |
Cool |
|
Schedule |
|
|
Note: The Auto and Em Heat system settings may not appear, depending on how your thermostat was installed.
Press the SYSTEM button to select:
•Heat: Thermostat controls only the heating system.
•Cool: Thermostat controls only the cooling system.
•Off: Heating and cooling systems are off.
•Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature.
•Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat.
Compressor is locked out.
FocusPROTM TH6000 Series
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends.
WAKE
6:00 am
70°
LEAVE
8:00 am
62°
RETURN
6:00 pm
70°
SLEEP
10:00 pm
62°
Set to the time you awaken and the temperature you want during the morning, until you leave for the day.
Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).
Set to the time you return home and the temperature you want during the evening, until bedtime.
Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
Operating Manual
EnergyStar® settings for maximum cost savings
This thermostat is pre-set to use EnergyStar® program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.)
|
|
|
Heat (Mon-Fri) |
Cool (Mon-Fri) |
Heat (Sat-Sun) |
Cool (Sat-Sun) |
||
|
|
|
|
|
|
|
||
(6:00 am) |
|
|
70° |
75° |
70° |
75° |
||
Wake |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(8:00 am) |
|
|
|
° |
|
° |
62° |
83° |
Leave |
|
|
62 |
|
83 |
|
|
|
|
|
|
|
|
[Or cancel period] |
[Or cancel period] |
||
(6:00 pm) |
|
|
|
° |
|
° |
70° |
75° |
Return |
|
|
70 |
|
75 |
|
|
|
|
|
|
|
|
[Or cancel period] |
[Or cancel period] |
||
Sleep |
|
|
62° |
78° |
62° |
78° |
||
(10:00 pm) |
|
|
10
FocusPROTM TH6000 Series
To adjust program schedules
Set Clock/Day/ |
Fan |
System |
||||
Auto |
|
Cool |
|
|||
|
Schedule |
|
|
|
|
|
|
|
|
|
|
|
|
Done
Set Day Set Schedule
Heat
Setting
Set Schedule 62
8:00AM
Leave Mon Tue Wed Thu Fri
Done CancelPeriod Next
1.Press SET CLOCK/DAY/SCHEDULE, then SET SCHEDULE.
2.Press σ or τ to set your weekday Wake time (Mon–Fri), then press NEXT.
3.Press σ or τ to set the temperature for this time period, then press NEXT.
4.Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
5.Press NEXT to set weekend time periods (SatSun), then press DONE to save & exit.
Note: Make sure the thermostat is set to the system you want to program (Heat or Cool).
Note: You can press CANCEL PERIOD to eliminate unwanted time periods (except Wake).
11
Operating Manual
Program schedule override (temporary)
Press to temporarily adjust temperature.
|
|
|
|
|
|
|
|
|
Inside |
|
|
|
Temporary |
Heat |
|
||
|
|
|
Setting |
|
||||
|
|
|
||||||
69 |
6:30AM 75 |
|
||||||
Run Schedule |
Fan |
System |
|
|||||
|
|
|
|
|
Auto |
Heat |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press to cancel temporary setting and resume program schedule.
Note: Make sure the thermostat is set to the system you want to control (heat, cool or auto).
Press σ or τ to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period.
The new temperature will be maintained only until the next programmed time period begins (see page 10). For example, if you want to turn up the heat early in the morning, it will automatically be lowered later, when you leave for the day.
To cancel the temporary setting at any time, press RUN SCHEDULE.
12
FocusPROTM TH6000 Series
Program schedule override (permanent)
Press to permanently adjust temperature.
|
|
|
|
|
|
|
|
Inside |
|
|
|
Heat |
|
||
69 |
|
Hold |
Setting |
|
|||
6:30AM |
75 |
|
|||||
|
|
||||||
Run Schedule |
Fan |
System |
|
||||
|
|
|
|
Auto |
Heat |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press to cancel “Hold” setting and resume program schedule.
Note: Make sure the thermostat is set to the system you want to control (heat, cool or auto).
Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods.
The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed.
Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN
SCHEDULE to cancel “Hold” and resume the programmed schedule.
13
Operating Manual
Auto changeover (heat/cool)
Set Clock/Day/ |
Fan |
System |
||
Auto |
|
Auto |
||
Schedule |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press until screen displays “Auto”
Note: The Auto system setting may not appear, depending on how your thermostat was installed.
Auto Changeover is a feature used in climates where both air conditioning and heating are used on the same day. When the system is set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature.
Heat and cool settings must be at least 3 degrees apart. The thermostat will automatically adjust settings to maintain this 3-degree separation (called “deadband”).
The 3-degree separation between heating and cooling set temperatures is fixed, and cannot be changed.
14
FocusPROTM TH6000 Series
Built-in compressor protection
Inside |
Cool |
||||
75 6:30AM |
75 |
|
|||
|
|
|
|
Setting |
|
|
|
|
|
Cool On |
|
Set Clock/Day/ |
Fan |
System |
|||
Auto |
|
|
Cool |
|
|
Schedule |
|
|
|||
|
|
|
|
|
|
Message flashes until safe restart time has elapsed
This feature helps prevent damage to the compressor in your air conditioning or heat pump system.
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting.
During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
15