2-zone application
2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX
With the new 2-channel Receiver box (R6H911RF) and
2x a T6R wireless smart thermostats (T6H700RW)
automatic time and temperature control of 2 heating
zones and a boiler for homes and apartments can be
managed.
It’s compatible with 24-230V on/off and OpenTherm®
appliances such as gas boilers, combi-boilers and heat
pump. Also works with zone valve applications but not
with electric heating (240V).
The solution is designed with the installer in mind.
The 2-channel Receiver box offers mounting options for
directly on the wall or on a wall box. Wiring can be from
below or from the back by lifting the terminal platform,
which makes installation quick and easy.
The T6R wireless thermostat has a high contrast PMVA
display with dynamic text line and touch screen buttons.
The thermostat has a simple programming philosophy to
make it easier to install and very user friendly.
The 2-zone solution is ideal for consumers who want to
split the comfort control of their home in 2 areas, like
upstairs and down-stairs or a living and working area.
The solution offers remote comfort control of both zones
via the Honeywell Home app.
FEATURES
T6R Smart Thermostat
Attractive, ultra-modern styled thermostats make it ideal for
any location in any type of home.
Wireless with table stand to fit a new and retrofit
installations.
Wi-Fi communication to connect to the Internet
- Smart Home and Apple HomeKit ready
A dynamic text display on the LCD that gives enhanced
feedback to the user / installer.
High LCD Contrast and backlighting for easier viewing in all
light conditions.
Time out screen with selectable brightness
Factory programmed daily or 5+2 default heating schedule.
Schedule with up to 6 independent time and temperature
pairs to suit the comfort needs.
“Hold until” temperature override of programmed schedule
temperature till the next switch point.
Schedule off mode for manual operation.
Setpoint and room temperature always displayed.
OFF position has an integral frost protection setting at
minimum 5C so that pipes in the house will never freeze in
winter.
Alert messages to assist in fault-finding.
Honeywell Home mobile App for:
- Remote view and change of settings
- Schedule changes
- Smartphone Geolocation temperature control
User menu allows extra functions to be set at the discretion
of the user:
- Language selection
- Wi-FI setup
- Optimisation
- Clock setting
- Resetting the heating program to factory default
- Brightness
- Temperature offset
- Lock function
Advanced menu (Installer Set-Up) allows extra functions to
be set at the discretion of the installer to match the
consumers applications and needs:
- System type
- OpenTherm data
- Upper / Lower Set point Limit Adjust
- Minimum ON time
- Cycle rate
- Factory Reset
- Binding
2-channel Receiver box
Clear LED indication of bound devices
Override button per zone with LED indication
Simple binding via override button
A flip up wiring platform for easy wiring
Pinhole for easy reset.
2 on/off relay outputs
OpenTherm
®
compatible heating control output.

2 ZONE T6R SMART THERMOSTAT
2 T6R-2Z-EN0H 8603 NL01 R0718
T6R THERMOSTAT DISPLAY/BUTTON LAYOUT

2 ZONE T6R SMART THERMOSTAT
T6R-2Z-EN0H 8603 NL01 R0718
WIRING OPTIONS 2-CHANNEL RECEIVER BOX
The 2-channel Receiver box always requires 230V power and is suitable for both 24V and 230V zone valve
applications.
Note: For the wiring of the OpenTherrm® boiler a separate cable is required.
C) Wiring 2 zone valves (24V) and 24V
on/off boiler
Zone valve end switches used for
controlling boiler (demand)
D) Wiring 2 zone valves (24V) OpenTherm®
boiler
Demand of zones used for controlling
(modulating) OpenTherm® boiler
A) Wiring 2 zone valves (230V) and basic
230V on/off boiler
Zone valve end switches used for
controlling boiler (demand)
B) Wiring 2 zone valves (230V) and OpenTherm®
boiler
Demand of zones used for controlling
(modulating) OpenTherm® boiler

2 ZONE T6R SMART THERMOSTAT
T6R-2Z-EN0H 8603 NL01 R0718
B. Wall box or Rear wiring
Hinge open the terminal block flap to access the
cables and wall box screw holes.
C. Surface wiring
Use the cable clamps to secure the surface
wiring.
D. Replace cover
Locate the hinges at the top of the cover and wall
plate, close the cover and secure with the screw.
A. Opening and removing top cover
Loosen the front screw and hinge open to remove
the top cover.
To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
Find a suitable location near the boiler. Leave at least 30cm distance from any metal objects including wall
boxes and boiler housing.
POWER UP 2-CHANNEL RECEIVER BOX
Turn ON mains power to the 2-channel Receiver box and the Heating Appliance and installation is complete.
None of the LED’s will be lit after power up!
Do not plug-in the adapter of one of the T6R thermostats yet, because they need to be bound to the Receiver
box.
MOUNTING AND WIRING 2-CHANNEL RECEIVER BOX