Application
A Radiator Thermostat is installed onto a Thermostatic Radi­ator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temper­ature by adjusting the flow of hot water through a radiator.
TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.
Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.
Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.
Features
• Conforms with M30 x 1.5 connection to European stan­dard EN 215
• Equipped with wax sensor
• Over-temperature protection
• Modern, ergonomical design with red economy button for optimal setting
• Compact size
Design
The radiator thermostat consists of:
• Handwheel with lid, socket and red economy button
• Sensor with support cage
• Wax sensor
• Spindle assembly
• Connection nut
Materials
• Handwheel socket and lid made of plastic, white to RAL9016
• Economy button made of red plastic
• Socket, support cage and spindle assembly made of plastic
• Sensor filled with wax
• Connection nut made of nickel-plated brass
Specifications
Thermostat connection M30 x 1.5
Setpoint range 0 - - 1..6
Temperature range 1...26°C (34...79°F)
Closing dimension 11.5 mm
Function
Radiator thermostats of this type control the TRV body. The air passing around the sensor of the radiator thermostat causes the sensor to expand when the temperature rises. The expanding sensor closes the TRV accordingly. When the room temperature changes the TRV opens or closes proportionally. Only the amount of water required to maintain the room temper­ature set on the radiator thermostat is allowed to flow through the valve.
Honeywell y Subject to change EN0H-2018GE25 R0109
T1000 SERIES THERA-100
Dimensions and Ordering Information
ØD1
H
Fig. 1. Dimensions
Table 1. Dimensions
Type H closed H open ØD
Thera-100 76.8 82.5 50
NOTE: All dimensions in mm unless stated otherwise.
Table 2. Available versions and OS-Nos (OS=Ordering Specification)
Type EN215
certification
Thera-100 M30 x 1.5 T1002W0
M30 x 1.5 T1002W0GB
Connection OS-No.
1
EN215 Information
All radiator thermostats of this type with M30x1.5 connection in connection with certified Honeywell TRV bodies conform to the European Standard EN215.
Table 3. Comparison of radiator thermostats of this type specs and EN 215 requirements
Thera-100
with wax sensor
Min. setpoint temperature 6°C (43°F) 5...12°C (41...54°F) Max. setpoint temperature 26°C (79°F) 32°C (90°F) Hysteresis 0.8 1.0K Influence of differential pressure 0.7 1.0K Influence of static pressure 0.8 ≤ 1.0K Influence of heating medium 0.7 ≤ 1.5K Response time 20 min. 40 min.
NOTE: All °C- and °F-values specified at ideal incident flow. This can differ from stated values depending on installation position
and air flow.
NOTE: Influence of differential pressure depends on TRV body used.
EN215
requirements
Setpoint
Table 4. Setpoint temperature
Setpoint 0 123456
°C 1 6 11 14 17 20 23 26 °F 34 43 52 57 63 68 73 79
NOTE: All °C and °F-values approximate. Heating can freeze when radiator thermostats with zero-position are set at position '0'.
Zero-position is also thermostatically controlled - when temperature falls the TRV may open.
EN0H-2018GE25 R0109 2 Honeywell y Subject to change