Honeywell STT250 User Manual

Page 1
Honeywell
Housings for STT 3000
Series STT250
SMART TEMPERATURE T RANSMITTER
EN0I-6032 01/98 Housing Specifications and Dimensional Drawings
OVERVIEW
Honeywell’s STT250 range of Temperature Transmitters be supplied with of enclosures for direct sensor head, 2” pipe or wall mounting. Available materials include Aluminium, Plastic, Cast Iron and 316 Stainless Steel.
a wide variety
Select the most suitable housing for lowest installed cost, lightweight, corrosive environments or for safety approvals - whichever is most important to match your requirements.
All the housings for direct
sensor head mounting include the facilities for spring loading of the STT250 transmitter module at a 33mm pitch (DIN
43729).
When integral meter is
required, choose the pipe or wall (field) mount housing.
For Flame-Proof EEx d
applications, choose the Cast Iron housing and ensure that the sensor connection is sealed with an approved flametrap by ordering the sensor assembly with the transmitter and housing.
For FM or CSA Explosion-Proof
applications, choose the Aluminium or 316 SS field mount housing.
The housings can be supplied
with the STT250 transmitter installed by specifying from the STT250 Model Selection Guide included in Sales Specification Sheet EN0I-6031.
If the temperature transmitter is
pipe or wall mounted, a housing can be supplied with a sensor and a terminal block installed
for connection to the remote
mounted transmitter.
Order sensor and thermowells
for this direct sensor head mounting by referring to Specification EN0I-6033 (non­North America) and 34-44-29­01 (North America).
Page 2
Housing Specifications (in mm)
Aluminium Direct Head Mount Housing
Suitable for general purpose or Intrinsically Safe applications. Dimensions shown in Fig. 1. Housing entry length = 41 mm Material : LM24 Aluminium die casting. Sensor entry : 1/2”NPT Cable / conduit entry : 1/2”NPT or M20x1.5. Weight : 0.3kg (0.7 lb) Paint cover : beige polyester/ epoxy hybrid. Enclosure classification : IP65 Order as STT250 Table II selection A _ _.
Plastic Direct Head Mount Housing
Suitable for lightweight installation in salt air environments and for general purpose or Intrinsically Safe installations. Maximum temperature = 70° C (158° F) Dimensions shown in Fig. 2. Housing entry length = 26,5 mm Material : ABS Sensor entry : 1/2”BSP (equivalent to 1/2”NPT) Cable/ conduit entry : M20x1.5 Colour : light beige Weight : 0.1kg (0.2 lb) Enclosure classification : IP67 Order as STT250 Table II selection P _ _.
Cast Iron Direct Head Mount Housing
2 x M4
33
2 x M4
41
40
2 x M3
1/2" NPT
B-B section A-A section
Figure 1
A
33
57
A
85
1/2" NPT
C-C section A-A section
Figure 2
( 104)
or M20
1/2" NPT
or M20
1/2" NPT
26.5
Suitable for Flame-Proof EEx d applications when sensor with flame trap is included in total assembly.
Dimensions shown in Fig. 3. Housing entry length = 41 mm Material : Cast Iron Sensor entry : 1/2”NPT Cable/ conduit entry : M20x1.5 paint cover : light beige Weight : 2.5kg (5.5 lb) Enclosure classification : IP68 Conforms to the applicable requirements of NEMA 7 and 9. Order as STT250 Table II selection B _ _.
2 x M4
33
2 x M4
41
111
1/2" NPT
B-B section A-A section
Figure 3
or M20
1/2" NPT
EN0I-60322
Page 3
316 Stainless Steel Direct Head Mount Housing
Suitable for corrosive/ salt spray environments and for general purpose or Intrinsically Safe applications.
Dimensions shown in Fig. 4. Housing entry length = 40 mm
33
2 x M4
100
Material : 316SS Sensor entry : 1/2”NPT Cable/ conduit entry : 1/2”NPT or M20x1.5
40
Paint cover : none. Weight : 1.6kg (3.5 lb) Enclosure classification IP65
80
1/2" NPT
Order as STT250 Table II selection S _ _. Flame-Proof version available.
B-B section A-A section
Figure 4
Meters
Honeywell’s Series STT250 Temperature Transmitters can be supplied with local or remote indication. An Analogue or Smart meter can be mounted integral to the transmitter inside the field mount housing. Order an integral meter as part of the model number; Table II _ _ M and _ _ S, respectively. Order a remote meter as model RMA300. The analogue meter is a 4-20mA moving coil type and displays the temperature in 0 to 100% span. The Smart meter accepts 4-20mA or DE protocol and displays temperature on a LCD in engineering units or 0 to 100% span. The Smart meter displays temperature in 0 to 100% span with the STT25H HART unit. Refer to 34-ST­25-08D for more details. The remote digital meter reads DE protocol and displays temperature on a LCD in 0 to 100% span. Refer to 34-ST-25­07A for details.
or M20
1/2" NPT
STT250 Dimensions
Aluminium Pipe or Wall (Field) Mount Housing
Suitable for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications. Dimensions shown in Fig. 5 and 6. Material : Low copper Aluminium alloy Cable/ Conduit entries : 1/2”NPT. Paint cover : Beige polyester/ epoxy hybrid or beige epoxy painted. Weight : 1.1kg (2.4 lb) Enclosure classification : IP65. Conforms to the applicable requirements of NEMA 7and 9 for FM/ CSA Explosion-Proof applications. Order as STT250 Table II selection E _ _ or X _ _, respectively.
316 Stainless Steel Pipe or Wall (Field) Mount Housing
Suitable for corrosive/ salt spray environments and for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications. Dimensions shown in Fig. 5 and 6. Material : 316SS Cable/ Conduit entries : 1/2”NPT. 3/4” NPT or M20 available via an adaptor. Paint cover : none. Weight : 3.2 kg (6.9 lb) Enclosure classification : IP65 Order as STT250 Table II selection T _ _.
EN0I-6032 3
Page 4
Dimensions in Aluminium Field Mount Housing 316 Stainless Steel Field Mount Housing Figures 5 and 6 A B A B
Without integral meter 70 mm 120.8 mm 95.5 mm 146.3 mm
2.76 inch 4.76 inch 3.76 inch 5.76 inch
With integral meter 127 mm 210.8 mm 127 mm 210.8 mm
5.00 inch 8.30 inch 5.00 inch 8.30 inch
40
(1.57)
60
(2.36)
B
With meter
142
(5.59)
94
(3.7)
115
(4.53)
A
A
B
Without meter
PANEL
CABLE/CONDUIT
ENTRY 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR
PROVIDE 2
BOLTS AND NUTS
M8 TO THE
FIXATION
59.5
(2.34)
OPTIONAL 316 SS
WIRED ON TAG
PROCESS/SENSOR
ENTRY : 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR
FIELD MOUNT
HOUSING
Figure 5 - STT250 Wall Mounting Dimensions
EN0I-60324
Page 5
CLEARANCE FOR CAP
(7.54)
(0.59)
60
14.9
40
(2.36)
39
REMOVAL
(1.57)
(1.54)
191.5
A
B
CLEARANCE FOR CAP
A
B
REMOVAL
With meter Without meter
142
(5.59) 14.9
94
(3.7)
115
(4.53)
129.5 (5.1)
(0.59)
61.8
(2.43)
OPTIONAL 316 SS
WIRED ON TAG
PROCESS/SENSOR
ENTRY : 1/2" NPT
OPTIONAL M20 OR
3/4" NPT ADAPTOR
OPTIONAL MOUNTING BRACKET FOR 2" PIPE
CABLE/CONDUIT
ENTRY 1/2" NPT
OPTIONAL M20
OR 3/4" NPT
ADAPTOR
FIELD MOUNT
HOUSING
Figure 6 - STT250 Pipe Mounting Dimensions
29.2
(1.15)
36.7
(1.44)
39.2
(1.56)
″″″″G″″″″ DIN RAIL TOP HAT / ″″″″ΩΩΩΩ″″″″ DIN RAIL
EN0I-6032 5
Page 6
33
(1.3)
TOP HAT /
"G" DIN RAIL
DIN RAIL
24.1
(0.95)
Optional DIN rail clip
STT250
52
(2.05)
STT250 MODULE INSTALLATION WITH DIN RAIL
Figure 7 - STT250DIN Rail Mounting Dimensions
Distributor :
Industrial Automation and Control
Helping You Control Your World
Honeywell Inc.
In the U.S.A.: Honeywell Industrial Automation and Control, 16404 North Black Canyon Hwy., Phoenix, AZ 85023, (602) 313-5000 In Europe: Honeywell Pace, 1 Avenue du Bourget, B-1140 Brussels, Belgium, (32-2) 728-211
In Asia: Honeywell Asia Pacific Inc., N° 19, Toa Payoh, Lorong 8 #06-00, Singapore 1231, 354-6768 In the Mediterranean: Africa & Middle East Region, Honeywell SpA, Via Vittor Pisani 13, 20124 Milano, Italy, (39-2) 67731 In Canada: The Honeywell Centre, 155 Gordon Baker Rd., North York, Ontario M2H 3N7, 1-800-461-0013 In Latin America: Honeywell Inc., 14505 Commerce Way, Suite 500, Miami Lakes, Florida 33016-1556, (305) 3642300
Honeywell S.A., Zone Industrielle de Longpré, F-80084 Amiens Cédex 2, France, (33-3) 22-54-56-56
Honeywell
EN0I-60326