Honeywell sixsiren Installation Instructions Manual

O
P
E
N
O
P
E
N
Trigger the device again to complete enrollment
Serial Number Loop Number
Zone Description 1 Zone Description 2
Device Type Response Type
Alarm Report Chime Supervision
Panic Home
The Green LED is ON for 3 seconds
1
2
4
5
3
30
0
45
20
10
Programming Mode > Zones > Add New > Serial Number
6
Select
SAVE
The LED Flashes; wait up to about 20 seconds*
SiXTM
Series
This wireless siren/strobe is intended for use with Honeywell controls that support SiX™ series devices.
SiXSIREN
Gently twist the top of the Siren counterclockwise and the mounting bracket clockwise to separate them.
SiXSIREN
Enroll
This device can be enrolled and programmed either before or after installation.
1. Set the Lyric Controller in Programming Mode and go to Zone Programming. Select Add New, then Serial Number. Follow the controller’s instructions to begin enrollment.
2. Insert four 1.5V AA Lithium batteries (included) to activate the device and begin the enrollment process.
3. The Green LED flashes rapidly during enrollment (up to about 20 seconds*)
*NOTE: Enrollment time varies depending on the signal strength between the device and the controller.
The device sends its unique MAC ID address (Serial Number) and Services information to the controller.
The controller registers the device and displays
the transmitter data on screen.
4. Enrollment is confirmed when the Green LED is ON for 3 seconds and the controller chirps once.
5. Trigger the device tamper switch again to complete enrollment and press SAVE.
6. The device did not enroll in the system if:
The White LED flashes, the system chirps and the device powers down.
The Green LED flashes rapidly when the device
is removed from the mounting bracket (the tamper switch is triggered).
To restart the enrollment process, ensure the system is in programming mode and activate the tamper switch.
The device can also be manually enrolled. See the Controller’s Programming Guide for details.
Program the SiXSIREN
Consult the Controller’s instructions for programming the device in the system. sensing –
range is 0° – 120° F (-18° – 49° C); accuracy ±3° F (1.67° C)
OPEN
After enrolling, update the SiXSIREN firmware (via the
Controller) to ensure the latest version is used. See the Controller’s instructions.
NOTE: Once enrolled in a system, the device cannot be used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
O
P
E
N
O
P
E
N
(2) #6 x 1” (3.5 mm x 25 mm)
(1) #4 x 1/4” (2.9 mm x 6.4 mm)
[A]
R = Red
W = White
G = Green
= ON
=
Slow Flash
R
=
Rapid Flash
=
Strobe Flash
R
=
Chirp
=
Burglary Warble
=
Temporal Pulse 3
=
Temporal Pulse 4
LEDs Sounders
G
G
G
G
R
R W
/
W
W
R
G
Mounting
NOTE: Before mounting the device permanently, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength and adjust the device location and orientation as necessary.
The SiXSIREN can be mounted on the wall or on the ceiling.
The rear tamper breakout [A] MUST be mounted to a stud, solid wood, or with a robust wall anchor.
Test the SiXSIREN
The SiXSIREN should be tested immediately after installation and weekly. Activate Test Mode remotely from the Controller (see Controller’s manual for details). The product must be tested at least once a year.
Test Mode tests the sounder and LED:
Sounder – the Burglary warble tone will sound for 3 seconds.
LED – the White LED strobe will flash for 15 seconds.
SiXSIREN LEDs and Sounder
Refer to the table below for operation of the four bi-colored LEDs and an 85dB sounder.
R / W G / W Sounder Status
Green Rapid Flashes for
White Flashing Strobe1
White Strobe Flashing
Red ON for 20
seconds
Alternating Red and
(continues until the
Alarm is cleared)
1
Strobe flash = two flashes per second, then OFF for 1 second.
2
It is best to replace the battery BEFORE the chirping begins. Once started, the sounder continues to chirp until batteries are replaced or die. See
the Battery Replacement section.
Red flashes once
every 45 seconds
about 20 seconds, then
ON for 3 seconds
Green Slow Flashing for
Green ON for 20 seconds
White Strobe Flashing
Green Flashes slowly for
3 seconds
10 minutes
Chirps once
Chirps once
System is Disarmed
System is Armed
Burglary Warble
ON for 3 seconds
2
Tamper Activated
Power Up – Enrollment
Power Up – Device enrolled
Smoke / Heat Alarm
CO Alarm
Burglary Alarm
Low Battery
Loading...