Honeywell SIXMINICT Installation Instructions Manual

Acier = 0.625 po (15.86mm)
SiXMINICT
Wireless Door/Window Sensor – Contact de Porte / Fenêtre Sans Fil
Installation Instructions Instructions d’installation
The SiXMINICT is a wireless door/ window sensor intended for use with Honeywell
controls that support SiX series devices.
Magnet Breaking Gap: Wood = 1.375 in. (34.93mm) Steel = 0.625 in. (15.86mm)
Ce contact de porte / fenêtre sans fil est conçu pour être utilisé avec les panneaux de commande Honeywell qui supportent les dispositifs de
MC
la série SIX
.
Écart de l'aimant : Bois = 1,375 po (34.93mm)
Enrolling / Enrôlement
For Lyric Controller
1. Set the Lyric Controller in Programming Mode and select SiX Programming:
Security > Tools > [installer code] > Program > (scroll down) > SiX Programming
Follow the controller’s instructions.
2. Pull the battery tab to activate the SiXMINICT and begin the enrollment process. (Or, Use the magnet if the tab is removed)
3. The LED flashes (up to about 20 seconds*) during enrollment.
The device sends its unique MAC ID (Serial
Number) and Services type to the controller.
The controller registers the device and displays
the sensor data on screen. *NOTE: Enrollment time varies depending on the
signal strength between the device and the controller.
4. When done, the LED is ON for 3 seconds and the control beeps to confirm enrollment.
5. Select the device and press EDIT. Assign the Zone Descriptor and set the Device Type (Door or Window). Verify the Service and Response Type and set the other options as desired.
6. To complete enrollment, select SAVE.
Pour Lyric Controller
1. Réglez Lyric Controller en mode de programmation et sélectionnez SiX Programming:
Sécurité > Outils > [code installateeur] > Program > (défiler vers le bas) > Programmation SiX
Pour commencer l'enrôlement, suivez les instructions du panneau de commande.
2. Retirez la languette qui recouvre la pile pour activer le SiXMINICT et commencer la procédure d'enrôlement. (Ou, si la languette est déjà retirée, utilisez l'aimant.)
3. Durant l'enrôlement, la DEL clignote (jusqu'à 20 secondes*).
Le dispositif transmet au panneau de commande son
ID MAC (numéro de série) et l'information pour les services.
Le panneau de commande enregistre le dispositif et
affiche les données du transmetteur sur l'écran. *NOTE : La durée de l'enrôlement varie selon la puissance du signal entre le dispositif et le panneau de commande.
4. Une fois terminé, la DEL demeure allumée durant 3 secondes et le panneau de commande émet 3 bips pour confirmer l'enrôlement.
5. Sélectionnez la zone et appuyez sur EDIT. Attribuez le descripteur de zone et définissez le type de périphérique (porte ou fenêtre). Vérifiez le type de service et de réponse et définissez les autres options selon vos besoins.
6. Déclenchez de nouveau le dispositif pour mettre fin à l'enrôlement et sélectionnez Enregistrer garder.
For Lyric Controller (continued)
Pour Lyric Controller (a continué)
The device can also be manually enrolled by entering the MAC ID (serial number) at the prompt. See the Controller’s Programming Guide for details.
Follow instructions in the Controller’s programming guide to program the SiXMINICT zone attributes.
Le dispositif peut également être enrôlé manuellement. Pour les détails, reportez-vous au Guide de programmation du panneau de commande.
Suivez les instructions du Guide de programmation du panneau de commande pour programmer les SiXMINICT.
For Lyric Gateway
Use AlarmNet 360™ to enroll and program this sensor.
NOTE: Once enrolled in a system, the SiXMINICT cannot be used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
Mounting
NOTE: After enrolling, verify adequate signal strength by conducting Go/No Go tests (see the controller’s instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.
Signal Strength: Range of 1-4 bars (green); should be minimum 1 green bar for the Zone being programmed. Four red bars indicate poor signal strength; the device should be relocated. See the Control’s instructions for bar indication signal strength values.
1. Separate the unit from the back cover.
2. Mount the unit as shown. Mount the Sensor to a stationary surface, and mount
the magnet on the moveable surface.
3. Replace the back cover. Sensor Location Feature: To verify the location of each
SiX device in an installation, enter programming mode and select a SiX device zone. The device LED lights (can take up to 30 seconds). Select it again to turn the LED off or select the next device to locate.
Pour Lyric Gateway
Enrôlez et programmez le système au moyen d’AlarmNet
MC
.
360
NOTE : Une fois enrôlé, le SiXMINICT ne peut pas être utilisé avec un autre système avant d'avoir été supprimé du panneau actuel. Reportez-vous aux instructions du panneau.
Installez
NOTE : Après l'enrôlement, vérifiez la puissance du signal adéquate en effectuant des tests Go / No Go (voir les instructions du panneau de commande) avec le dispositif dans son emplacement de montage prévu. Au besoin, modifiez l'emplacement ou l'orientation du dispositif.
Force du signal: Gamme de 1 à 4 bars (vert); Devrait être minimum de 1 barre verte pour la zone programmée. Quatre barres rouges indiquent une faible intensité de signal; L'appareil devrait être relocalisé. Reportez-vous aux instructions de contrôle pour les valeurs de l'indicateur de la barre de force du signal.
1. Séparez l'unité de la façade arrière.
2. Montez l 'appareil comme illustré.
Montez le capteur sur une surface stationnaire et
montez l'aimant sur la surface mobile.
3. Replacez la façade arrière.
Fonction d'emplacement du détecteur: Pour vérifier l'emplacement de chaque dispositif SiX dans une installation, entrez dans le mode de programmation et sélectionnez un dispositif SiX. Le voyant de le dispositif s'allume (peut prendre jusqu'à 30 secondes). Sélectionnez-le à nouveau pour éteindre la LED ou sélectionnez le prochain dispositif à localiser.
– 2 –
Loading...