KaltecSoft PW50AS/BS/CS
max.
min.
Construction
The water softener consists of:
• Cabinet in modern, space-saving design
• Electronic regeneration system controlled by volume
• Status indicator and control panel
• Bottle with monodisperse ion exchanger
• Connector adapter, incl. Bypass valve
• External transformer; the device is only fed with a protective
low voltage of 24 V
• Filter combination FK06
Materials
• Cabinet in high-grade synthetic material
• All components subject to pressure in glass-fibre-reinforced
plastics
• All components to brine in Noryl
EN0H-1412GE23 R0807 • Subject to change
Water treatment
Product specification sheet
Application
Calcium carbonate dissolved in water is a valuable mineral but
may create serious problems to private households as soon as
the water is heated. A solid layer of lime scale will form, preferably
on hot surfaces. This scale reduces the heat efficiency of water
heaters and the life time of expensive appliances. KaltecSoft is
designed to provide a cost efficient solution to protect your water
installations. KaltecSoft combines the proven ion exchange technology with a state-of-the-art control valve. Regeneration is
volume controlled to ensure minimum consumption of water and
salt. Available in three different sizes KaltecSoft is easy to install
and simple to operate. The included filter combination FK06
protects not only KaltecSoft but also appliances and water pipes
against corrosion caused by impurities in the water. Together
with the integrated pressure reducing valve it extends the life time
of the whole installation.
Special Features
• Stops scale from forming
• Increases equipment efficiency and protects appliances
• Cuts soap/detergent bills by up to 50%
• Full automatic, meter control saves water and salt
• Filter combination included
• KaltecSoft is set on night regeneration as default
Range of Application
Medium Water
Water temperature 5-30°C
Operating pressure 2,0-8,0 bar
Technical Data
Ambient temperature 2-40°C
Nominal pressure PN 10
Nominal flow rate (∆p=1,0 bar) 1,4 m
Nominal flow rate (∆p=1,8 bar) 1,8 m
Reverse rinsing max. (∆p=1,8 bar) 1,6 m
Supply voltage (ext. transformer) 230 V / 50 Hz
Protective extra low voltage 24 V
Power consumption 2 W (during treatment)
Protection class IP 22
Connection size 3/4" external
Connection sewerage 1/2" hose nozzle
3
/h
3
/h
3
/h
www.honeywell.com 1
KaltecSoft PW50AS/BS/CS Water treatment
Method of Operation
Hard or medium-hard drinking water contains large amounts of
lime, which can deposit in pipes, fittings and devices and result
in irreparable damages.
KaltecSoft is based on the simple exchange of minerals. Calcium
and magnesium is replaced by sodium, thus preventing additional scale build up.
Options
Type Resin volume
PW50-AS KaltecSoft 10 litres
PW50-BS KaltecSoft 15 litres
PW50-CS KaltecSoft 20 litres
Version PW50-AS PW50-BS PW50-CS
Connection size 3/4" external 3/4" external 3/4" external
Dimensions mm
H 660 990 1120
W 310 310 310
D 425 425 425
Resin volume L 10 15 20
Consumable material store approx. kg 40 80 100
Salt consumption/regeneration g 1362 1873 2520
Exchange capacity between regenerations* mol 5 7,5 10
Operating capacity mol 4 8 8
3
x°dH 22 44 44
m
Regeneration period min 25 35 45
3
Nominal flow rate (∆p=0,8 bar, full softening mode) m
* Softening of water
/h 1,4 1,4 1,4
2 www.honeywell.com
EN0H-1412GE23 R0807 • Subject to change