Honeywell LP916 Catalog Page

Pneumatic Thermostats
LP916 Pneumatic Thermostat
Application Type: Unit Ventilator Dimensions, Approximate: 4 3/4 in. high x 3 3/4 in. wide x 3 in. deep
(121 mm high x 95 mm wide x 76 mm deep)
Airflow Usage: 0.022 scfm (10.4 mL/s) with 0.007 in. restriction Air Connections: Barb fittings 1/4 in. (6 mm) Number of Pipes: 2 Mounting: In compartment of a unit ventilator Operating Temperature: 135 F maximum (57 C maximum) Storage Temperature: 150 F maximum (66 C maximum) Setpoint: Single Remote Bulb: Ye s Maximum Operating Pressure: 25 psi (170 kPa)
Setpoint Temperature Range Changeover
Product Number Action
LP916A1019/U Direct Acting 65 F to
LP916A1134/U Direct Acting 65 F to
LP916A1175/U Direct Acting 40 F to
LP916B1017/U Direct Acting
LP916B1058/U Direct Acting
LP916B1074/U Direct Acting
LP916B1082/U Direct Acting
LP916B1090/U Direct Acting
LP916C1023/U Reverse
Heating, Reverse Acting Cooling
Heating, Reverse Acting Cooling
Heating, Reverse Acting Cooling
Heating, Reverse Acting Cooling
Heating, Reverse Acting Cooling
Acting
85 F
85 F
80 F
65 F to 85 F
65 F to 85 F
65 F to 85 F
65 F to 85 F
65 F to 85 F
60 F to 80 F
19 C to
3.5 F 2 C Warmer /
30 C
19 C to
3.5 F 2 C Warmer /
30 C
4 C to
7 F ñ13 C40 F to 80
26 C
19 C to
Heat 18 psi,
30 C
Cool 13 psi
19 C to
Heat 18 psi,
30 C
Cool 9 psi
19 C to
Heat 18 psi,
30 C
Cool 13 psi
19 C to
Heat 18 psi,
30 C
Cool 13 psi
19 C to
Heat 18 psi,
30 C
Cool 13 psi
15 C to
3.5 F 2 C 60 F to 80
26 C
Heat 124 kPa, Cool 90 kPa
Heat 124 kPa, Cool 62 kPa
Heat 124 kPa, Cool 90 kPa
Heat 124 kPa, Cool 90 kPa
Heat 124 kPa, Cool 90 kPa
Two-pipe, single temperature, unit mounted, remote bulb pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems.
• Liquid filled remote bulb.
• Direct Acting (DA), Reverse Acting (RA) and Heating/Cooling (DA/ RA) models are available.
Accessories:
107324A-Capillary Holder Assembly for duct insertion, 8 3/8 in. long
Replacement Parts:
14003113-002-Repair kit containing 0.007 in. restrictor plate, filters, and
gaskets
Throttling Range
3.5 F 2 C Warmer /
3.5 F 2 C Warmer /
3.5 F 2 C Warmer /
3.5 F 2 C Warmer /
3.5 F 2 C Warmer /
Scale Markings Includes Comments
Cooler
Cooler
F
Cooler
Cooler
Cooler
Cooler
Cooler
F
Integral Mounting Bracket and 304528A Bag Assembly (mounting hardware). Order bu b hangers (316297-00021) separately.
Integral Mounting Bracket, (2) 316297­00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).
Integral Mounting Bracket and 304528A Bag Assembly (mounting hardware). Order bu b hangers (316297-00021) separately.
Order Mounting Bracket, Knob, Bulb Hangers, and Scale Plate separately.
Integral Mounting Bracket, (2) 316297­00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).
Bu b 1/2 x 5 7/8
Bu b 3/8 x 7 in.,
Bu b 3/8 x 7 in.,
Bu b 1/2 x 5 7/8
Bu b 1/2 x 5 7/8
Bu b 3/8 x 7 in.,
New installation model
Bu b 3/8 x 9 in.,
Bu b 3/8 x 9 in.,
Sensor Element(F) (C) (psi) (kPa) (F) (C)
in., capillary 36 in. (914 mm) long
capillary 36 in. (914 mm) long
capillary 36 in. (914 mm) long
in., capillary 36 in. (914 mm) long
in., capillary 36 in. (914 mm) long
capillary 36 in. (914 mm) long
Bu b 3/8 x 7 in., capillary 36 in. (914 mm) long
capillary 36 in. (914 mm) long
capillary 36 in. (914 mm) long
Pneumatic
Controls
70-6910 647