Honeywell JTYJ-GD-01BW, JTYJ-GD-01LM User Manual

Honeywell Smokr detector
Overview
Honeywell Smoke Detector is a stand-alone re alarm, that detects the presence of a high concentration of smoke, then emits a light and sound alarm, so you can take the necessary security measures, protect yourself, your family and your property.
Accessories
Alarm box x1
Battery x1
The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2
Sound output holes
Switch button «Sound stop / Self-monitoring»
Smoke input hole
Installation
1. Fastening with screws
A) Insert a battery into battery compartment, press and hold the «Sound stop / Self-check» button for 1 second. Make sure that the red-yellow indicator is ashing on the device, after which you will hear a corresponding beep; B) Drill holes in the ceiling with a perforator; C) Insert the dowels; D) Using self-tapping screws, attach the mounting plate; E) Attach the main alarm panel to the mounting panel in accordance with all the index marks, scroll clockwise until you hear a click, that indicates xation of the device.
Using self-tapping screws, install the mounting plate. Attach the main alarm panel to the mounting panel in accordance with all the index marks. Scroll clockwise until it clicks.
2. Mounting with adhesive tape A) Insert a battery into the battery compartment, press and hold the «Sound stop / Self-check» button for 1 second. Make sure that the red-yellow indicator is ashing on the device, after which you will hear a corresponding beep; B) Remove the protective lm from one side of the adhesive tape and attach it to the back of the mounting panel; C) Remove the protective lm from the other side of the adhesive tape and attach
the mounting plate to the ceiling;
D) Attach the main alarm panel to the mounting panel in accordance with all the index marks, scroll clockwise until you hear a click, that indicates the xation of the device.
3. Precautions during installation
A) The device is only used indoors; B) The distance between the device and the lighting equipment should be more than 50 cm; C) Do not install the device in a bathroom, in areas, where water easily enters; D) Do not install near any heat sources or steam; E) Do not install the unit in rooms with a temperature of -10 ° C and lower or 55 ° C or higher; F) If the cabinet is su󰀩ciently close to the ceiling, the distance between the cabinet and the independent re alarm should be 60 cm or more; G) The distance between the device and the hood, the air conditioner and the vent windows (openings) should be more than 150 cm; H) It is recommended to install the device with screws. If you have chosen a method, using adhesive tape, in the event of an unforeseen situation, the user is solely responsible; I) If you use the device mounting method, using adhesive tape, the selected mounting surface must be smooth, at, dry and clean; J) If you have chosen a method using adhesive tape, it is necessary to regularly check the reliability of fastening the device to avoid its falling; K) If the battery leaks, you will not be able to install the device into the mounting panel.
Loading...