Honeywell HR80 Installation and User Guide

HR 80
Installation and User Guide Montage und Bedienung Installatie- en Bedieningsinstructie
1 Overview and use
The radiator controller HR 80 is a component of the zoning system. It can be installed on all the common radiator valves. As the valve is a self contained unit, there is no risk of it causing any water leakage from your heating.
The set temperature can be changed...
manually using the adjustment dial on the operating unit of the radiator controller
with the command centre
1.1 Pack content (Fig. A)
1 Operating unit 2 Coupling module 3 Adapter Danfoss RA
1.2 Operating elements and display (Fig. B, C)
1 Display: Shows current set
temperature and device information.
2 Adjustment dial on the
operating unit: Allows manual temperature adjustment.
3 Symbol for the RF connec-
tion to the command centre.
2 Installation
Remove the old thermostat.
2.1 Inserting/Changing batteries (Fig. D)
Open battery compartment (Fig. D).
► ► If necessary, remove empty batteries.
Do not dispose of batteries with household trash. They must be returned in accordance with the local statutory requirements.
Always replace both batteries. Only use 1.5 V alkaline batteries of the type LR06.
Insert the new batteries into the battery compartment. Ensure that
the polarity is correct!
Close the battery compartment.
If the batteries were changed after a successful binding procedure, Section 2.4).
2.2 Separating operating unit from the coupling
module (Fig. E, F)
Turn the point of the locking knob (1) upward to open the lock. (Fig. E).
Pull operating unit and coupling module apart from each other
(Fig. F).
2.3 Installing coupling module (Fig. G, H, I)
The Honeywell-Braukmann, MNG, Heimeier, Junkers, Landis & Gyr 'Duogyr' valves do not require an adapter. For adapters for Oventrop, Danfoss, Herz and Vaillant valves, refer to Section 8.
Turn the adjustment dial (3) of the coupling module
counterclockwise until the nose (1) of the adjustment dial is positioned at the stop (2) of the housing (Fig. G).
Push coupling module onto the radiator valve (Fig. H). Slide metal knurled nut onto the threading of the radiator valve.
(Fig. I)
Tighten the metal knurled nut without using a tool (Fig. I).
Radiator Controller
Heizkörper­regler
Radiator­regelaar
4 Batteries 5 Caleffi adapter
4 Symbol for separating the
operating unit and coupling
module. 5 Set temperature 6 Symbol for actual value
coming from the command
centre (optional).
appears in the display (see
Honeywell GmbH
Böblinger Straße 17 71101 Schönaich, Germany Tel.: (++49) (0) 7031 637 01 Fax: (++49) (0) 7031 637 493 http://europe.hbc.honeywell.com
Hereby, Honeywell Inc., declares that th is radiator controller is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.The pr oduct´s conformity declaration can be r equested from the manufacturer.
Non-EC-countries Note: Use of this produc t is only permitted if the 433 MHz and/o r 868 MHz frequency band is approved f or this application.
Hiermit erklärt Honeywell Inc., dass s ich dieser Heizkörperregler in Übereinstim mung mit den grundlegenden Anforderun gen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Die Konformitätserklärung des Produkts kann beim Hersteller angefordert werden.
Hinweis Nicht-EU Länder: Dieses Produk t darf nur verwendet werden, wenn der Betrieb auf dem 433 MHz und/oder 868 MHz Frequenzband zugelassen ist.
Hierbij verklaart Honeywell Inc. dat het toestel radiator regelaar in overe enstemming is met de essentiële eis en en de andere relevante bepalingen van richtlijn 1999/5/EG. De verklaring van conformiteit vo or dit product kan opgevraagd worden bij de fabrikant.
Voor niet-EC-landen: gebruik dit produc t alleen als de 433 MHz en/of de 868 MHz frequentie-band goedgekeurd is voor deze applicatie.
The right is reserved to make modif ications. This document replaces all previous publications.
MU2H-0299 GE51R0505A
A
B
Hint: The correct installation of the coupling module is best
checked with the central heating switched on. If the coupling module is correctly installed, the radiator will become warm (adjustment dial positioned at the left-hand stop).
2.4 Activating binding procedure (Fig. J)
Caution!
New components of the zoning system must be assigned to the command centre before they can be taken into operation. This process is called the "binding procedure".
Position the operating unit directly near the corresponding
Press the binding procedure button (1, Fig. J) for approx. one
If several radiator controllers are to be controlled simultaneously in one room:
Press the binding procedure button on all the radiator controllers
Activate binding procedure at the command centre (see operating
The radiator controller receives data from the command centre. This process can take up to 4 minutes.
Remove the disturbing/shielding devices, e.g. wireless
Repeat the binding procedure.
The radiator controller communicates with the central operating unit via a wireless connection.
When selecting the operating site ensure that the
distance to wireless devices such as wireless headphones, cordless phones etc. is approx. 1–2 m according to the DECT standard.
First read through all the steps for the complete binding procedure and then carry them out. The binding procedure mode remains active at the radiator controller for a maximum of 4 minutes.
coupling module.
second and then release it.
When the binding procedure button is released, the symbol flashes and the software version number is displayed for 30 seconds.
consecutively.
instructions of the command centre).
During binding procedure, the symbol is shown
continuously in the display of the radiator controller. The
following is displayed: .
Failed binding procedure
The binding procedure has failed if the symbol extinguishes. Take the following measures:
headphones, cordless telephones, loudspeakers, garage door openers.
If the symbol extinguishes during normal operation, possible causes are discharged batteries at the command centre. You do not have to repeat binding operation, if the communication is reestablished. If you remove the batteries and insert them again, the HR80 goes direct in sync mode.
The set temperature at the radiator controller is automatically set to 20 °C.
C
6543
1 Übersicht und Anwendung
Der Heizkörperregler HR 80 ist eine Komponente des Einzelraum­Regelungssystem. Er kann auf alle gängigen Heizungsventile mon­tiert werden. Schmutz- oder Wasserflecken entstehen nicht.
Die Soll-Temperatur können Sie ändern ...
von Hand mit dem Stellrad am Bedienteil des Heizkörperreglers
mit der zentralen Bedieneinheit
1.1 Lieferumfang (Abb. A)
1 Bedienteil 2 Ventilaufsatz 3 Adapter Danfoss RA
1.2 Bedienelemente und Display (Abb. B, C)
1 Display: Zeigt aktuelle Soll-
Temperatur und Geräte­informationen.
2 Stellrad am Bedienteil:
Ermöglicht manuelle Temperatureinstellung.
3 Symbol für Sendeverbin-
dung zur zentralen Bedien­einheit.
2 Montage
Alten Thermostat entfernen.
2.1 Batterien einlegen/wechseln (Abb. D)
Batteriefach öffnen (Abb. D).
► ► Gegebenenfalls leere Batterien entfernen.
Gebrauchte Batterien nicht mit dem Hausmüll entsorgen, sondern entsprechend den gesetzlichen Bestimmungen zurückgeben.
Immer beide Batterien wechseln. Nur 1,5-V-Alkaline-Batterien vom Typ LR06 verwenden.
Neue Batterien in das Batteriefach einlegen. Auf richtige Polung
achten!
Batteriefach schließen.
Werden nach erfolgreichem Teach-in die Batterien ge­wechselt, erscheint im Display
2.2 Bedienteil vom Ventilaufsatz trennen (Abb. E, F)
Spitze des Verriegelungsknopfs (1) nach oben drehen, um die
Verriegelung zu öffnen (Abb. E).
Bedienteil und Ventilaufsatz auseinander ziehen (Abb. F).
2.3 Ventilaufsatz montieren (Abb. G, H, I)
Die Ventile Honeywell-Braukmann, MNG, Heimeier, Junkers, Landis & Gyr 'Duogyr' erfordern keinen Adapter. Adapter für Oventrop-, Danfoss-, Herz- und Vaillantventile siehe Rückseite, Kap. 8.
Stellrad (3) des Ventilaufsatzes gegen den Uhrzeigersinn drehen,
bis die Nase (1) des Stellrads am Anschlag (2) des Gehäuses sitzt (Abb. G).
Ventilaufsatz auf das Heizkörperventil schieben (Abb. H). Metallrändelmutter auf das Gewinde des Heizkörperventils
schieben (Abb. I).
Metallrändelmutter ohne Werkzeug festdrehen (Abb. I).
TIPP: Am einfachsten lässt sich die korrekte Montage des Ventil-
aufsatzes prüfen, wenn die zentrale Heizung eingeschaltet ist. Der Heizkörper wird bei korrekt montiertem Ventilauf­satz warm (Stellrad am linken Anschlag).
D
H
4 Batterien 5 Adapter Caleffi
4 Symbol für Trennung von
Bedienteil und Ventilauf-
satz. 5 Soll-Temperatur 6 Symbol für Ist-Wert, der von
der zentralen Bedieneinheit
kommt (optional).
(siehe Kap. 2.4).
E
I
2.4 Teach-in aktivieren (Abb. J)
Achtung!
Neue Komponenten des Einzelraum-Regelungssystems müssen der zentralen Bedieneinheit zugeordnet werden, bevor sie in Be­trieb gehen können. Dieser Vorgang wird "Teach-in" genannt.
Bedienteil in unmittelbare Nähe des zugehörigen Ventilaufsatzes
Teach-in-Taste (1, Abb. J) für ca. eine Sekunde drücken und
Wenn in einem Raum mehrere Heizkörperregler gleichzeitig ange­steuert werden sollen:
Teach-in-Taste der Reihe nach an allen Heizkörperreglern drü-
Teach-in an der zentralen Bedieneinheit aktivieren (siehe Bedie-
Der Heizkörperregler empfängt Daten von der zentralen Bedien­einheit. Dieser Vorgang kann bis zu 4 Minuten dauern.
Störende/abschirmende Geräte entfernen, z. B. drahtlose
Teach-in wiederholen.
Der Heizkörperregler kommuniziert per Funk mit der zentralen Bedieneinheit.
Bei der Wahl des Betriebsorts auf ca. 1–2 m Ab-
stand zu Funkgeräten wie Funk-Kopfhörer, schnurlose Telefone nach DECT-Standard etc. achten.
Zuerst alle Handlungsschritte für den gesamten Teach-in durchlesen und dann ausführen. Der Teach-in-Betrieb bleibt am Heizkörperregler für maximal 4 Minuten aktiv.
bringen.
dann loslassen.
Beim Loslassen blinkt das Symbol und die Versionsnummer der Software wird für 30 Sekunden angezeigt.
cken.
nungsanleitung zur zentralen Bedieneinheit).
Während des Teach-ins wird das Symbol kontinuierlich im Display des Heizkörperreglers angezeigt. Es erscheint die Anzeige: .
Misslungener Teach-in
Der Teach-in ist misslungen, wenn das Symbol er­lischt. Folgende Maßnahmen durchführen:
Kopfhörer, schnurlose Telefone, Lautsprecher, Garagentoröffner.
Wenn im Normalbetrieb das Symbol erlischt, ist kein erneuter Teach-in nötig. Möglicherweise sind die Batterien der zentralen Bedieneinheit leer. Nach einem Batterie­wechsel wird der HR 80 automatisch synchronisiert.
Die Soll-Temperatur am Heizkörperregler wird automa­tisch auf 20 °C gesetzt.
F
G
1
J
1 Overzicht en gebruik
De radiatorregelaar HR 80 maakt deel uit van het Zone-regel­systeem. De HR 80 kan op alle gangbare radiatorafsluiters worden gemonteerd. Er ontstaan geen vuil- of watervlekken.
De insteltemperatuur kunt u als volgt wijzigen...
met de hand, met behulp van de instelknop op het bedienings­gedeelte van de radiatorregelaar
met de centrale bedieningseenheid
1.1 Inhoud van de verpakking (afb. A)
1 Bedieningsgedeelte 2 Koppelstuk 3 Hulpstuk Danfoss RA
1.2 Bedieningselementen en schermweergave
(afb. B, C)
1 Weergave scherm: geeft de
actuele ingestelde temperatuur en informatie over de werking weer.
2 Instelknop: voor het hand-
matig instellen van de temperatuur.
3 Symbool voor de draadloze RF
verbinding met de centrale bedieningseenheid.
2 Montage
Verwijder de oude radiatorthermostaat.
2.1 Batterijen plaatsen/vervangen (afb. D)
Batterijvak aan de onderzijde openen (afb. D).
► ► Verwijder, indien nodig, de lege batterijen.
Werp gebruikte batterijen niet bij het normale afval, maar lever deze in bij een inzamelpunt voor KCA.
Vervang altijd beide batterijen tegelijk. Plaats alleen batterijen van het type LR06, 1,5 V, alkaline.
Plaats de nieuwe batterijen in het batterijvak. Let daarbij op de
juiste polariteit!
Sluit het batterijvak.
Wanneer de batterijen worden vervangen na een teach-in (zie Hfdst. 2.4), verschijnt op het scherm .
2.2 Bedieningsgedeelte van het koppelstuk afnemen
(afb. E, F)
Draai de punt van de vergrendelknop (1) naar boven, om de vergrendeling te openen (afb. E).
Trek het bedieningsgedeelte en het koppelstuk van elkaar los
(afb. F).
2.3 Koppelstuk monteren (afb. G, H, I)
Voor de thermostatische radiatorafsluiters van Honeywell (Ultraline), Heimeier, Junkers, Landis & Gyr ‘Duogyr’ is geen hulpstuk noodzakelijk. Voor Oventrop, Danfoss, Herz en Vaillant radiatorafsluiters wel, zie Hfdst. 8.
Draai het stelwiel (3) van het koppelstuk naar links, totdat het
nokje (1) van het stelwiel tegen de aanslag (2) van de behuizing zit (afb. G).
Plaats het koppelstuk op de afsluiter (afb. H). Schuif de metalen gekartelde moer op de schroefdraad van de
radiatorafsluiter (afb. I).
Draai de metalen gekartelde moer handvast. Zonder gebruik te
maken van gereedschap (afb. I).
4 Batterijen 5 Hulpstuk Caleffi
4 Symbool voor de scheiding
van bedieningsgedeelte en
het koppelstuk. 5 Ingestelde temperatuur. 6 Symbool voor de huidige
waarde, die afkomstig is
van de centrale bedie-
ningseenheid (optioneel).
Tip: De montage van het koppelstuk kan het beste worden
gecontroleerd, wanneer de centrale verwarming aan is. De radiator wordt warm, als het koppelstuk juist is gemonteerd (het stelwiel is geheel naar links gedraaid).
2.4 Teach-in activeren (afb. J)
Let op!
Om met de centrale bedieningseenheid te kunnen communiceren moeten de diverse componenten van het Zone-regelsysteem worden geïnitieerd. Deze procedure wordt ‘teach-in’ genoemd.
Houd ter controle van de communicatie het bedieningsgedeelte
Druk ca. 1 sekonde op de teach-in-knop (1, afb. J) en laat deze
Wanneer in één ruimte meerdere radiatorregelaren tegelijk moeten worden aangestuurd:
Druk achtereenvolgens op de teach-in-knop van alle
Activeer de teach-in-modus op de centrale bedieningseenheid
De radiatorregelaar ontvangt gegevens van de centrale bedie­ningseenheid. Dit kan maximaal 4 minuten duren.
Verwijder storende/afschermende apparatuur, bijv. draadloze
Herhaal de teach in.
De radiatorregelaar communiceert draadloos (radiografisch) met de centrale bedieningseenheid. Hou daarom bij plaatsing rekening met de nadelige gevolgen van metalen objecten, zoals kasten en wapening van betonvloeren etc..
Zorg voor een afstand van ca. 1–2 m tot overige
draadloze apparatuur (o.a. draadloze koptelefoons en DECT-telefoons).
De teach-in modus van de radiatorregelaar blijft maximaal 4 minuten actief. Maak uzelf daarom van tevoren vertrouwd met de volgende stappen.
nabij het bijbehorende koppelstuk op de radiator.
weer los.
Bij loslaten knippert het pictogram en wordt gedurende 30 seconden het versienummer van de software getoond.
radiatorregelaren in de betreffende ruimte.
(zie de instructies van de centrale bedieningseenheid).
Gedurende de teach-in wordt het symbool continu weergegeven op het scherm van de radiatorregelaar. Vervolgens verschijnt de melding: op het scherm.
Mislukte teach-in
Als het -symbool op het scherm verdwijnt, is de teach­in mislukt. Voer, om de communicatie te verbeteren, de volgende maatregelen uit:
telefoons, koptelefoons, luidsprekers, etc.
Wanneer tijdens normaal bedrijf het pictogram dooft, hoeft de teach-in niet te worden herhaald. Het kan zijn dat dan de batterijen van de centrale bedieningseenheid leeg zijn. Na het vervangen van de batterijen wordt de HR 80 weer automatisch gesynchroniseerd.
De temperatuurinstelling van de radiatorregelaar wordt automatisch op 20 °C ingesteld.
K L M N O P Q R S T
2.5 Finishing installation of radiator controller (Fig. K, L, M)
Turn the retaining bracket on the operating unit until the tip points
upwards (Fig. K).
The lock on the coupling module opens.
Slide the operating unit onto the coupling module (Fig. L). Turn the retaining bracket to the side (Fig. M).
The operating unit and coupling module are connected firmly. The symbol disappears from the display of the HR 80. The
radiator controller is now ready for operation.
2.6 Installing radiator controller onto another valve
Before screwing the radiator controller onto another valve:
Separate the valve lantern from the operating unit. Mount the valve lantern as described in Section 2.3.
3 Operation
Every local change in the setpoint temperature remains valid until a time program overwrites it automatically.
The set temperature is controlled by the command centre and set there as well. For further information please refer to the operating instructions of the command centre.
3.1 Changing set temperature with adjustment dial
Turn the adjustment dial of the operating unit until the desired set
temperature (between 5 – 30 °C) is displayed.
The range for the set temperature (standard range: 5 – 30 °C) can be restricted at the command centre.
In order to open or close the radiator valve completely:
Turn the adjustment dial until "OFF" (closed) or "ON" (opened) is
displayed. (If temperature limits are set, "ON"/"OFF" is not displayed.)
3.2 Changing batteries
If Batt appears in the display, both batteries must be replaced (see Section 2.1).
If the batteries are too weak, the radiator controller opens the radiator valve completely.
If the batteries are replaced after the binding procedure has been completed, is displayed.
The radiator controller waits for data from the command centre.
3.3 Emergency operation with empty batteries (Fig. E, F, N)
Separate operating unit from coupling module (Fig. E and F).
Use the adjustment dial to open (in the direction of the plus sign)
or close (in the direction of the minus sign) the heating valve manually (Fig. N).
4 Automatic functions
4.1 Window function
If you open a window and the temperature drops sharply within a short period, the radiator controller closes the radiator valve in order to save energy. The display then shows the message
When the temperature rises again, the radiator controller returns to normal operation, however at the latest after 30 minutes.
The window function can be deactivated at the command centre.
4.2 Protection against valve malfunction
If the valve is not opened once completely within a period of 2 weeks, the valve is opened and shut again briefly. This ensures that the valve does not seize. The display then shows the message cycle. The 2-week cycle begins at the moment at which the
operating unit is connected to the valve lantern.
4.3 Frost protection
If the temperature drops below 5 °C, the radiator controller keeps the radiator valve at a constant 5 °C.
The frost-protection value (standard value: 5 °C) can be changed at the command centre.
The frost-protection function does not function when the batteries are empty or the operating unit is removed.
5 Def (default setting) and Full operating
modes
In order to change between the two operating modes, press the binding procedure button (1, Fig. J) until the respective operating mode is shown on the display.
5.1 Def (default setting) operating mode
The HR 80 operates with the optimum valve lift that is required for room temperature control.
5.2 Full operating mode
If the complete valve lift is to be used or if the valve does not close completely, you have to set the HR 80 to the full operating
mode.
The battery lifetime is reduced in the full operating mode.
6 Resetting the HR 80 to the factory settings
Separate operating unit from the valve lantern (Fig. E and F). Remove the batteries. Insert the batteries again while keeping the binding procedure
button pressed.
Attach the operating unit to the valve lantern (Fig. K, L and M).
7 Status message E3
If the symbol e3 is shown on the display, the motor of the HR 80 can no longer be moved.
8 Installing additional devices or parts
The following adapters/coupling modules are available for Oventrop, Herz, Danfoss, Vaillant and Caleffi valves:
Coupling module type Order name
Oventrop HU 01 (Fig. N) (knurled nut M30x1)
Herz HU 02 (Fig. O) (knurled nut M28)
Adapter type
Danfoss adapter set EVA 1-Danfoss
RAV (gray) (Fig. P) RA (white) (Fig. Q) RAVL (black) (Fig. R)
Vaillant adapter EHA 1VAI (Fig. S)
Caleffi (Fig. T)
HU 01
HU 02
EVA 1-Danfoss
(enclosed)
EHA 1VAI
(enclosed)
8.1 Installing adapter
Select the required adapter.
Open up the adapter and push it onto the valve as far as the stop.
Turn it while doing so until you feel it click into place.
If provided on the adapter:
Screw the adapter firm or insert the adapter pin.
9 Service mode (for installers only)
The wireless contact between the radiator controller, the command centre and a receiver unit is checked in Service mode.
Separate operating unit from coupling module (see Section 2.2.
.
Fig. F)
Turn the adjustment dial until on (open) appears in the display. Turn adjustment dial two full rotations (720°) further.
TesT is displayed. Service mode is active.
The radiator controller transmits a test message to any avail­able receiver unit (e.g. HC60ng).
Press the binding procedure button.
The radiator controller is ready to receive the test message from the command centre.
The first two digits in the display indicate the number of re­ceived test messages, and the right-hand digit indicates the field strength (1 = sufficient field strength, 5 = very good field strength)
To deactivate Service mode:
Press the binding procedure button for 5 seconds or wait 5
minutes or remove and then reinsert the batteries.
Service mode is deactivated.
10 WEEE directive 2002/96 EG
electric and electronic law
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.
2.5 Heizkörperregler fertig montieren (Abb. K, L, M)
Haltebügel am Bedienteil drehen, bis die Spitze nach oben zeigt (Abb. K).
Die Verriegelung für den Ventilaufsatz öffnet sich.
Bedienteil auf den Ventilaufsatz schieben (Abb. L). Haltebügel wieder zur Seite drehen (Abb. M).
Bedienteil und Ventilaufsatz sind fest verbunden.
Im Display des HR 80 erlischt das Symbol . Der Heizkörperregler ist jetzt betriebsbereit.
2.6 Heizkörperregler auf ein anderes Ventil montieren
Bevor Sie den Heizkörperregler auf ein anderes Ventil schrauben:
Trennen Sie den Ventilaufsatz vom Bedienteil. Montieren Sie den Ventilaufsatz wie in Kap. 2.3 beschrieben.
3 Bedienung
Jede lokale Änderung der Soll-Temperatur ist so lange gültig, bis sie automatisch durch ein Zeitprogramm überschrieben wird.
Die Soll-Temperatur wird von der zentralen Bedieneinheit geregelt und dort eingestellt. Näheres ist in der Bedienungsanleitung der zentralen Bedieneinheit beschrieben.
3.1 Soll-Temperatur am Stellrad ändern
Am Stellrad des Bedienteils drehen, bis im Display die ge-
wünschte Soll-Temperatur (zwischen 5-30 °C) angezeigt wird.
Der Bereich für die Soll-Temperatur (Standardbereich 5­30 °C) kann an der zentralen Bedieneinheit eingeschränkt werden.
Um das Heizungsventil vollständig zu öffnen oder zu schließen:
Am Stellrad drehen, bis im Display "OFF" (geschlossen) oder
"ON" (geöffnet) erscheint. (Wenn Temperaturlimits eingestellt sind, wird "ON"/"OFF" nicht angezeigt.)
3.2 Batteriewechsel
Wenn im Display Batt erscheint, müssen beide Batterien ge­wechselt werden (siehe Kap. 2.1).
Sind die Batterien zu schwach, öffnet der Heizkörperregler das Heizkörperventil vollständig.
Werden nach erfolgreichem Teach-in die Batterien gewechselt, erscheint die Anzeige .
Der Heizkörperregler wartet auf Daten der zentralen Bedieneinheit.
3.3 Notbedienung bei leeren Batterien (Abb. E, F, N)
Bedienteil vom Ventilaufsatz trennen (Abb. E und F).
► ► Heizungsventil mit dem Stellrad am Ventilaufsatz von Hand öff-
nen (in Richtung des Pluszeichens) oder schließen (in Richtung des Minuszeichens) (Abb. N).
4 Automatische Funktionen
4.1 Fensterfunktion
Wenn Sie ein Fenster öffnen und dadurch die Temperatur in kurzer Zeit stark sinkt, schließt der Heizkörperregler das Heizungsventil, um Energie zu sparen. Im Display erscheint dann die Meldung
. Wenn die Temperatur wieder steigt, spätestens aber nach 30 Minu­ten, nimmt der Heizkörperregler wieder den normalen Betrieb auf. Die Fensterfunktion kann an der zentralen Bedieneinheit ausge­schaltet werden.
4.2 Schutz vor Festsitzen des Ventils
Wird das Ventil innerhalb von 2 Wochen nicht einmal vollständig geöffnet, wird das Ventil kurzzeitig geöffnet und wieder zugefahren. Damit wird verhindert, dass sich das Ventil festsetzt. Im Display erscheint dann die Meldung cycle. Der 2-Wochen Zyklus beginnt
an dem Zeitpunkt, an dem das Bedienteil mit dem Ventilaufsatz verbunden wurde.
4.3 Frostschutz
Sinkt die Temperatur unter 5 °C, regelt der Heizkörperregler das Heizungsventil auf 5 °C konstant.
An der zentralen Bedieneinheit kann der Frostschutzwert (Standardwert ist 5 °C) geändert werden.
Der Frostschutz funktioniert nicht bei leeren Batterien oder abgezogenem Bedienteil.
5 Betriebsarten Def (Standardeinstellung)
und Full
Um zwischen den beiden Betriebsarten zu wechseln, drücken Sie die Teach-in-Taste (1, Abb. J), bis die jeweilige Betriebsart auf dem Display erscheint.
5.1 Betriebsart Def (Standardeinstellung)
Der HR 80 arbeitet mit dem optimalen Ventilhub, der zur Raumtemperaturregelung benötigt wird.
5.2 Betriebsart Full
Wenn der gesamte Ventilhub ausgenutzt werden soll, oder das Ventil nicht vollständig schließt, müssen Sie den HR 80 auf die Betriebsart full einstellen.
In der Betriebsart full verringert sich die Batterielebensdauer.
6 HR 80 auf Werkseinstellungen zurücksetzen
Bedienteil vom Ventilaufsatz trennen (Abb. E und F). Batterien entfernen. Halten Sie die Teach-in-Taste gedrückt und legen dabei die
Batterien wieder ein.
Bedienteil und Ventilaufsatz verbinden (Abb. K, L und M).
7 Statusmeldung E3
Wenn das Symbol e3 auf dem Display erscheint, kann der Motor des HR 80 nicht mehr bewegt werden.
8 Montage zusätzlicher Geräte oder Teile
Für Oventrop-, Herz-, Danfoss-, Vaillant- und Caleffiventile sind folgende Adapter/Ventilaufsätze erhältlich:
Ventilaufsatztyp Bestellbezeichnung
Oventrop HU 01 (Abb. N) (Rändelmutter M30x1)
Herz HU 02 (Abb. O) (Rändelmutter M28)
Adaptertyp
Danfoss-Adapter-Set EVA 1-Danfoss RAV (grau) (Abb. P)
RA (weiß) (Abb. Q) RAVL (schwarz) (Abb. R)
Vaillant Adapter EHA 1VAI (Abb. S)
Caleffi Adapter (Abb. T)
HU 01
HU 02
EVA 1-Danfoss
(liegt bei)
EHA 1VAI
(liegt bei)
8.1 Adapter montieren
Erforderlichen Adapter wählen.
Adapter aufweiten und bis zum Anschlag auf das Ventil schieben.
Dabei drehen, bis er spürbar einrastet.
Wenn am Adapter vorgesehen:
Adapter mit Schraube festziehen oder Adapterstift aufsetzen.
9 Service-Modus (nur für Installateure)
Im Service-Modus wird der Funkkontakt zwischen Heizkörperreg­ler, zentraler Bedieneinheit und einer Empfängereinheit überprüft.
Bedienteil vom Ventilaufsatz trennen (siehe Kap. 2.2 Abb. F). Am Stellrad drehen, bis im Display on (geöffnet) erscheint. Stellrad um zwei volle Umdrehungen (720°) weiterdrehen.
Im Display erscheint TesT. Der Service-Modus ist aktiviert.
Der Heizkörperregler sendet eine Testmeldung an eine evtl. vorhandene Empfängereinheit (z. B. R6660D).
Teach-in-Taste drücken.
Der Heizkörperregler ist empfangsbereit für eine Testmeldung von der zentralen Bedieneinheit.
Auf dem Display geben die ersten beiden Ziffern die Anzahl der empfangenen Testmeldungen, die rechte Ziffer die Feld­stärke an (1=ausreichende Feldstärke, 5=sehr gute Feldstärke)
Um den Service-Modus zu deaktivieren:
Teach-in-Taste 5 sec lang drücken oder 5 Minuten warten oder
Batterien entfernen und wieder einlegen.
Service-Modus ist deaktiviert.
10 WEEE-Richtlinie 2002/96 EG
2.5 Voltooien montage radiatorregelaar (afb. K, L, M)
Schuif het bedieningsgedeelte op het koppelstuk (afb. L). Draai de klembeugel zo, dat de punt richting het koppelstuk wijst
2.6 Radiatorregelaar op een andere afsluiter monteren
Voordat u de radiatorregelaar op een andere afsluiter monteert:
Scheidt het koppelstuk van het bedieningsgedeelte. Monteer het koppelstuk zoals beschreven in Hs. 2.3.
3 Bediening
De gewenste temperatuurinstelling wordt door de centrale bedieningseenheid geregeld. Voor een gedetailleerde beschrijving zie de gebruiksaanwijzing van de centrale bedieningseenheid.
3.1 Gewenste temperatuurinstelling met de
Om de radiatorafsluiter volledig te openen of te sluiten:
Draai aan de instelknop, tot op het scherm ‘OFF’ (dicht) of ‘ON’
3.2 Batterijen vervangen
Wanneer op het scherm Batt verschijnt, dienen beide batterijen te worden vervangen (zie Hfdst. 2.1).
3.3 Noodbediening bij lege batterijen (afb. E, F, N)
► ► Afsluiter via het stelwiel openen (draai in de richting van plus-
4 Automatische functies
4.1 Vensterfunctie
Wanneer u een raam openzet, waardoor de temperatuur in korte tijd sterk daalt, sluit de radiatorthermostaat de radiatorklep om zo energie te besparen. Op het scherm verschijnt dan de melding
Wanneer de temperatuur weer stijgt, of na maximaal 30 minuten, schakelt de radiatorregelaar terug naar de normale bedrijfsmodus. De vensterfunctie kan op de centrale bedieningseenheid worden uitgeschakeld.
4.2 Beveiliging tegen vastzitten van de klep
Wanneer de klep in een periode van 2 weken niet minstens één keer volledig is geopend, wordt de klep kort geopend en weer gesloten. Daarmee wordt voorkomen, dat de klep vast komt te zitten. Op het display verschijnt dan de melding cycle. De
tweewekelijkse cyclus begint op het moment waarop het bedieningsgedeelte wordt gekoppeld aan het koppelstuk.
4.3 Vorstbeveiliging
Wanneer de temperatuur onder 5 °C daalt, regelt de radiator­regelaar de afsluiter op een constante temperatuur van 5 °C. Op de centrale bedieningseenheid kan de vorstbeveiliging­temperatuur (standaardwaarde 5 °C) worden gewijzigd.
Elektro- und Elektronikgesetz
Entsorgen Sie Verpackung und Produkt am Ende der Produktlebensdauer in einem entsprechenden Recycling­Zentrum. Entsorgen Sie das Produkt nicht mit dem gewöhnlichen Hausmüll. Verbrennen Sie das Produkt nicht.
Draai de klembeugel op het bedieningsgedeelte zo, dat de punt naar boven wijst (afb. K).
De vergrendeling voor het koppelstuk is open.
(afb. M).
Het bedieningsgedeelte en koppelstuk zijn vast met elkaar verbonden.
Op het display van de HR 80 dooft het pictogram . De radiatorthermostaat is nu gereed voor gebruik.
Elke lokale wijziging van de insteltemperatuur blijft geldig, tot deze automatisch door een tijdprogramma wordt overschreven.
instelknop wijzigen
Draai aan de instelknop op het bedieningsgedeelte tot op het scherm de gewenste temperatuurinstelling wordt getoond.
De temperatuur kan tussen 5-30 °C worden ingesteld en kan bovendien met de centrale bedieningseenheid worden begrensd.
(open) verschijnt. (Wanneer temperatuurgrenzen zijn ingesteld, wordt "ON"/"OFF" niet getoond.)
Wanneer de batterijen bijna leeg zijn, wordt de radiatorafsluiter door de radiatorregelaar volledig open gezet.
Wanneer na een geslaagde teach-in de batterijen worden vervangen, verschijnt op het scherm .
De radiatorregelaar wacht op gegevens van de centrale bedieningseenheid.
Scheidt het bedieningsgedeelte van het koppelstuk (afb. E, F).
teken) of sluiten (draai in de richting van minteken (afb. N).
.
De vorstbeveiliging werkt niet bij lege batterijen of wanneer het bedieningsgedeelte is gescheiden van het koppelstuk.
5 Bedrijfsmodi Def (standaardinstelling)
en Full
Om tussen de beide bedrijfsmodi te wisselen, drukt u op de teach­in-knop (1, afb. J), tot de betreffende modus op het display verschijnt.
5.1 Bedrijfsmodus Def (standaardinstelling)
De HR 80 werkt met de optimale klepslag, die nodig is voor de temperatuurregeling van de ruimte.
5.2 Bedrijfsmodus Full
Wanneer de totale klepslag moet worden benut of de klep niet volledig sluit, moet u de HR 80 instellen op de modus full.
In de modus full hebben de batterijen een kortere levensduur.
6 HR 80 resetten naar de fabrieksinstellingen
Scheid het bedieningsgedeelte van het koppe lstu k (afb. E en F)
Verwijder de batterijen. Houd de teach-in-knop ingedrukt en plaats tegelijkertijd de
batterijen terug.
Koppel het bedieningsgedeelte aan het koppelstuk (afb. K, L en
M).
7 Statusmelding E3
Wanneer het pictogram e3 op het display verschijnt, kan de motor van de HR 80 niet meer in beweging worden gezet.
8 Aanpassingshulpstukken en toebehoren
aanbrengen
Voor thermostatische-afsluiters van Oventrop, Herz, Danfoss, Vaillant en Caleffi zijn de volgende adapter hulpstukken verkrijgbaar:
Koppelstuk type Bestelcode
Oventrop HU 01 (afb. N) (wartel M30x1)
Herz HU 02 (afb. O) (wartel M28)
Aanpassingshulpstuk type Danfoss-adapterset
EVA 1-Danfoss RAV (grijs) (afb. P) RA (wit) (afb. Q) RAVL (zwart) (afb. R)
Vaillant-adapter EHA 1VAI (afb. S)
Caleffi (afb. T)
8.1 Adapter monteren
Selecteer het benodigde hulpstuk.
Open de aanpassingshulpstuk en schuif deze tot aan de aanslag
op de afsluiter. Draai het hulpstuk daarbij licht heen en weer totdat het hulpstuk voelbaar vastklikt.
Indien noodzakelijk bij hulpstuk:
Borg het hulpstuk met de meegeleverde bout en breng, indien
nodig, de extra drukstift aan.
9 Service-modus (alleen voor installateurs)
In de service-modus wordt de draadloze RF- verbinding tussen radiatorregelaar, de centrale bedieningseenheid en ontvangst­eenheid gecontroleerd.
Scheid het bedieningsgedeelte van het koppelstuk (zie Hfdst. 2.2
afb. F)
Draai aan de instelknop, tot op het scherm on (open) verschijnt. Draai de instelknop twee volledige omwentelingen (720°) verder.
Op het scherm verschijnt TesT. De service-modus is geactiveerd.
De radiatorregelaar zendt een testboodschap naar een evt. beschikbare ontvangeenheid (b.v. HC60ng).
Druk op de teach-in-knop.
De radiatorregelaar is gereed voor het ontvangen van een testboodschap van de centrale bedieningseenheid.
Op het scherm geven de eerste twee cijfers het aantal ontvangen testboodschappen aan, en het rechter cijfer de veldsterkte (1=voldoende veldsterkte, 5=zeer goede veldsterkte).
Om de service-modus uit te schakelen:
Druk de teach-in-knop 5 sec. in of wacht 5 minuten of verwijder
de batterijen en plaats deze terug.
De service-modus is uitgeschakeld.
10 WEEE-richtlijn 2002/96 EG