HE220A,B AND HE260A,B BY-PASS FLOW-THROUGH HUMIDIFIERS
American Lung Association® Health House® Program and
Honeywell Working Together For Better Air
Did you know that the average person breathes 3400 gallons(12,870 liters) of air each
day * and spends 90% of that day inside?**
Indoor air quality products from Honeywell are designed to help make your home more
comfortable—from zoning products that allow you to control the temperature in
individual areas of the home to humidifiers and comfort control centers that help
balance the moisture content of your indoor air.
Honeywell is proud to be a partner of the American Lung Association® Health House®
program that provides guidelines for constructing homes with improved air quality and
ventilation.
For more information on ways to improve the air inside your home, please visit the
Health House website at:
www.healthhouse.org
and the American Lung Association website at: ww.lungusa.org
The American Lung Association and its Health House program do not endorse
products.
For more information about Honeywell Indoor Air Quality products, visit:
www.honeywell.com/yourhome
or call:
1-800-345-6770 x531
*EPA.National Air Quality 1999 Status & Trends.
**Indoor Air Pollution, An Introduction for Health Professionals, EPA, US Government Printing Office #1994523-217/81322.
IMPORTANT
69-1111EF-22
Please read these instructions and keep them in your records.
HE220A,B AND HE260A,B BY-PASS FLOW-THROUGH HUMIDIFIERS
7
4
OPERATING YOUR HUMIDIFIER
Your Honeywell HE220A and HE260A Humidifiers
are controlled by the H8908A Convertible Humidity
Control installed on either an interior wall in the
living area or on the return air duct. Choose the
humidity control setting using the combination
relative humidity/outdoor temperature setting scale
on your humidity control. Match the dial setting to
the outdoor temperature for optimizing the humidity
level while reducing the moisture condensation on
your windows. Use the table below to adjust the
humidity control to the recommended setting.
Humidity Control
Régulateur d'humidité
HUMIDITY
OUTDOOR
SETTING
TEMPERATURE
15%
-30 °C
F
-20 °
20%
-25 °C
-10 °F
25%
-20 °C
0 °F
30%
-10 °C
F
+10 °
35%
-5 °C
+20 °F
40%
C
Over 0 °
F
Over 20 °
M1469
At Outside
Tem per atur e
Recommended
Setting
At Outside
Temperature
Recommended
Setting
-20°F (-29°C)15+10°F (-12°C)30
-10°F (-23°C)20+20°F (-7°C)35
0°F (-18°C)25Above 20°F (-7°C)40
NOTE: As the outside temperature drops, the recommended humidity control setting
is lowered to accommodate for dewpoint effects. These settings should
reduce the accumulation of moisture and ice on your windows and in other
areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause
excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve,
ventilate your home to remove the moisture.
Your Honeywell HE220B and HE260B Humidifiers are
controlled by the Honeywell H1008 Automatic Humidity
Control with HumidiCalc+ Software. The automatic
humidity control is mounted in the return air duct where it
can be exposed to the return air airstream.The
HumidiCalc+ Software inside your automatic humidity
control is designed to automatically adjust the humidity
level based on indoor temperature and humidity, inferred
or measured outdoor temperature, and the frost factor
dial setting. The frost factor allows for variations in
furnace size, window insulation and average daily
H1008A
M1281
climate temperature.
369-1111EF-2
HE220A,B AND HE260A,B BY-PASS FLOW-THROUGH HUMIDIFIERS
The Automatic Humidity Control with HumidiCalc+ Software requires an initial
adjustment period. Set the frost factor dial on 5 and use the following table to adjust
the frost factor—only one setting at a time—increasing the dial setting if you feel you
need more humidity, or reducing the setting if you see moisture on the inside of your
windows. For more precise humidity adjustment, set the frost factor between dial
settings. Allow two days for the humidity level to subside before making further
adjustments. Once you have tuned in the proper setting, you should never have to
adjust it again. HumidiCalc+ Software takes over and makes any future adjustments
caused by varying outdoor temperatures, thus reducing moisture build-up on windows
while maintaining the optimal humidity level.
Humidity LevelRecommended Adjustment
Insufficient humidityIncrease the frost factor dial by one setting.
Condensation on windowsDecrease the frost factor dial by one setting.
HOW YOUR HUMIDIFIER WORKS
Your Honeywell humidifier uses the principle that vapor (evaporated water) is created
when warm air blows over a water soaked area. As the vapor circulates, the relative
humidity rises.
Your humidity control monitors the relative humidity and activates the humidifier
accordingly. The humidifier water supply disburses water evenly over the humidifier
pad. The warm dry air from the furnace passes over the humidifier pad and picks up
the moist air to circulate it through your home.
Humidified air feels warmer and more comfortable so you may be able to lower your
thermostat heating setpoint and save money on your heating fuel bills. The end result
is that your humidifier gives you a comfortable environment that is also energy
efficient.
MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your humidifier and provides a
more comfortable home. Frequency of cleaning depends on the condition of your
water.
You can use either hard or soft water in your humidifier, but hard water mineral
deposits are more difficult to clean than soft water deposits.
69-1111EF-24
HE220A,B AND HE260A,B BY-PASS FLOW-THROUGH HUMIDIFIERS
A
PerfectFlo™ WATER
H
W
DISTRIBUTION TRAY
WATER FEED NOZZLE
HUMIDIFIER PAD ASSEMBLY
UMIDIFIER HOUSING
ATER FEED TUBE
SIDEWALL
COVER
BYPASS SIDEWALL
Every 1 to 3 Months (Depending on Water Quality)
WARNING
Voltage Hazard.
Can cause electrical shock and equipment damage.
Disconnect power and shut off water supply before installing or servicing.
IMPORTANT
Never oil any part of the humidifier.
Use the following procedure to clean your Honeywell humidifier:
1. Disconnect the power and turn off the humidifier water supply.
2. Remove the humidifier cover.
3. Remove the humidifier pad assembly from the humidifier by grasping the tray and pull-
ing it toward you.
4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from
the frame.
5. Gently pinch the water nozzle catches inward until you can lift the water nozzle off the
tray.
6. Slide the humidifier pad out of the frame.
569-1111EF-2
M12327
HE220A,B AND HE260A,B BY-PASS FLOW-THROUGH HUMIDIFIERS
7. Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain
hole has nothing blocking it.
8. Clean the humidifier pad with a putty knife.
NOTE: If excessive mineral deposits are present, replace with a new pad.
9. Disconnect the drain hose from the drain fitting on the bottom of the humidifier housing.
10. Clean the drain fitting, if necessary.
11.Bend the drain hose to loosen any mineral deposits.
12. lush the drain hose with pressurized water (a running tap) to clean the hose.
13. Reattach the drain hose to the drain fitting.
14. Slide the humidifier pad back into the frame.
15. Snap the water nozzle back onto the tray.
16. Reattach the tray to the frame.
17. Place the humidifier pad assembly in the humidifier housing and press until the assembly
is completely seated. Be careful not to pinch or kink the water feed tube.
18. Replace the humidifier cover.
19. Verify the humidifier operation by following the steps in the Checking the
Humidifier for Proper Operation section.
End of Humidification Season
Clean the humidifier and shut it off at the end of the heating season. Use the Every 1 to
3 Months section, steps 1 through 18 to shut down for the season.
IMPORTANT
Be sure the humidifier power is off.
Vacation
When leaving on vacation, turn off the humidfier water supply and your humidity
control. Turn on the water supply and reset your humidity control when you return.
CHECKING YOUR HUMIDIFIER OPERATION
After winter startup or servicing, check the humidifier operation:
1. Turn on the humidifier power and water supply.
2. Turn the H908A Convertible Humidity Control to the highest setting, or the H1008A
Automatic Humidity Control to the test position, and set the thermostat to 10°F (6°C)
above the room temperature.
69-1111EF-26