Honeywell H46C User Manual

H46C Humidity Controller
2 X 3 IN.
INSTALLATION INSTRUCTIONS
APPLICATION
The H46C Humidity Controller is used with portable and central unit dehumidifiers to maintain relative humidity. The H46 has an spst, snap-acting switch designed for line voltage circuits and two leadwires for switch box mounting.
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous condition.
2. Check the ratings in the instructions and on the
product to make sure the product is suitable for your application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
CAUTION
Electrical Shock Hazard. Can cause electrical shock or equipment damage.
Disconnect power supply before connecting wiring.
Location
Select a location about 5 ft (1.5m) above the floor in an area with good circulation at average temperature and humidity for the area to be controlled. Avoid locations near hot or cold air ducts and discharged air from the controlled equipment.
Mounting
1. Remove the setting knob.
2. To remove cover, pull cover forward from device.
3. Install a 2 in. x 3 in. (51 mm x 76 mm) vertical
switch box at the selected location.
4. Using the two screws provided, fasten the adapter
plate to the switch box, as shown.
5. Pull the wires from the switch box through the
opening in the adapter plate and connect to the H46 leadwires with the solderless connectors provided. See Fig. 2 and 3 for typical hookup.
6. Push the wires back into the switch box.
7. Place the H46 against the adapter plate, making
certain the tab at the bottom of the plate fits into the notch on the H46.
8. Fasten the H46 to the adapter plate by tightening
the captive screw.
9. Replace the cover and the setting knob.
ADAPTER PLATE
H46 CAPTIVE MOUNTING SCREW
SCREWS (2)
H46 (COVER OFF)
NYLON ELEMENT
Fig. 1. Mounting H46C on vertical switch box.
SWITCH BOX
ADAPTER PLATE
PLATE TAB
H46 LEADWIRES (2)
WALL SURFACE
M7907
Wiring
Disconnect power supply before connecting wiring to avoid electrical shock or equipment damage. All wiring must comply with local codes or equipment damage. All wiring must comply with local codes and ordinances. Do not exceed contact and coil ratings when wiring into system. See Fig. 2.
® U.S. Registered Trademark Copyright © 2003 Honeywell International Inc. • • All Rights Reserved
95-5367-4
H46C HUMIDITY CONTROLLER
H46C
R
N
P
R
S
3
HUMIDITY
CONTROLLER
RISE
L1 (HOT)
OWER
1
UPPLY
L2
PROVIDE DISCONNECT MEANS AND OVERLOAD
1
PROTECTION AS REQUIRED.
DEHUMIDIFIE EXHAUST FA OR AIR CONDITIONE
M7923
Fig. 2. Typical H46C wiring diagram.
Connections and Operation
A dehumidistat in combination with the thermostat can be used to run the air conditioner to control relative humidity levels. The dehumidistat and thermostat can be wired in parallel or in series.
Wiring in parallel allows the dehumidistat to indepen­dently control the humidity level, but could cause overcooling of the home. During unoccupied times, the homeowner should set the thermostat to a relatively high setting and control moisture using the dehumidistat.
Wiring in series prevents overcooling but the air conditioner runs only when both the thermostat and dehumidistat are calling. During unoccupied times, the homeowner should set the thermostat to a relatively low setting and control moisture using the dehumidistat.
SETTING AND ADJUSTMENT
The H46 makes contact on a relative humidity rise to the setpoint to start the dehumidifier. On a decrease in relative humidity to the setpoint (minus the differential), the switch breaks contact to stop the dehumidifier. Turn the knob clockwise to the setting stop to place the H46 in the On position. Turn the knob counterclockwise to the setting stop to place the H46 in the Off position.
CHECKOUT
After completing all mounting and wiring, turn on the power supply. Place the system into operation by turning the setting knob toward the low end of the scale until the dehumidifier motor starts. Turn the setting knob slowly toward the high end of the scale until the dehumidifier motor stops.
H46C
FILTER LIGHT
HEAT OFF FANAUTO ONCOOL
3 2
PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS
1
AS REQUIRED. HEATING DAMPER MOTOR, IF USED.
2 3
CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION.
Fig. 3. Typical parallel wiring hookup for H46C with T87F/Q539A combination
for dehumidification and mildew control.
T87F/Q539A INTERNALSCHEMATIC
R1
BX O
T87F
TEMPERATURE FALL
W1 Y1
HEAT OFF COOL
W Y
HEATING RELAY OR VALVE COIL
COOLING CONTACTOR COIL
FIXED COOL ANTICIPATOR
G RHR
FAN RELAY COIL
ADJUSTABLE HEAT ANTICIPATOR
1
M791
95-5367-4 2