Honeywell GC-715P24, GC-715N24 User Manual

DSP COLOR CAMERA
GC-715N24 GC-715P24
TM
* “
TM
BMB
BMB
” is the Trade Mark of Honeywell, CCTV CoE.
MEMO
READ AND RETAIN THIS OPERATION MANUAL
Control Products Business Unit
18F, Kukje Center Building, 191, Hangangro-2ga, Yongsan-gu, Seoul 140-702, Korea Tel : 82-2-799-6109 Fax : 82-2-749-6119
E-mail : cctv@honeywell.com
http://www.honeywell.co.kr/cctv
Printed in Korea
G-110821
CAUTION
RISK OF ELECTRIC SHOCK
DO N OT O PEN
Explanation of Graphical Symbols.
This symbol is intended to alert the user to the presence of uninsulated dangerous voltagewithin the products enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operating and maintenance(Servicing) Instructions in the literature accompanying the appliance.
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER(OR BACK).
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PRERSONNEL
MEMO
CAUTIONS FOR SAFE OPERATION !
Changes or modifications not approved
by manufacturer could void the user’s authority to operate the equipment.
To prevent fire or shock hazard, do not
expose this camera to rain or moisture.
To prevent electric shocks and other
hazards, do not use different from the specified power source.
Do not install too hot or cold places,
recommended operation temperature is -10~ 50
Do not expose lens directly to the sun.
CCD may be damaged.
Do not place the camera to heavy
shocks or vibrations.
Do not place or install the camera on
an unstable place, stand, tripod, bracket or table. That may cause serious injury to people or damage to appliance.
Do not attempt to service or repair of
yourself. Please contact all servicing to qualified service personnel
In case of installing too close to Monitor,
variation of monitor brightness cause any hunting of camera in low light mode.
1
1
Cautions for safe operation ------------------------------------- 1
About GC-715N/P24 ------------------------------------- 3
Name and function of each section ------------------------------------- 4
Installation ------------------------------------- 5
Adjustment and operation ------------------------------------- 8
Specifications ------------------------------------- 23
Accessory
C mount adapter
IRIS JACK for AUTO IRIS LENS
2
2
GC-715N/P24
Outlines
Honeywell’s GC-715N/P24 is a high sensitivity CCD color camera with high sensitivity
function of the field integration technique.
Features
1/3” IT Super HAD CCD ( NTSC: 410,000 / PAL: 470,000 )Outstanding BLC implementation with Honeywell’s BMB(Black Mask BLC) function.
( 3 levels adjustable )
CS/C lens mount.Excellent signal-to-noise ratio of more than 50dB.High Sensitivity : Minimum illumination of 0.001lx ( F1.2, 30IRE, SENS On X 128 )2-WAY Auto Iris : Video iris or DC iris lens can be used.External synchronization with LINE LOCK. Auto White Balance : Auto white balance realizes true color reproduction within various
light sources. ( 2,800 ºK~8,000 ºK )
Control : Flickerless, Back light compensation , AGC , Manual shutter control,
Maximum Sensitivity select, Auto white Balance/ Indoor/Outdoor/Fluorescent light/ BMB Level
Name and function of each section
3
3
51
⑥⑦
68
148
AUTO IRIS lens connectorAUTO IRIS lens select switchSync. select switchVideo output connectorPower input connectorPower lampDC IRIS level adjustment
(when using DC IRIS lens)
V- PHASE adjustment
(when using LINE LOCK)
[unit : mm]
4
4
Installation
Mounting a Lens
1. Remove the protective cap in front of the camera.
2. Confirm the mount ring whether it is for C or CS. * Caution1
3. Attach the lens to the lens mount ring.
4. If the lens has an Auto Iris mechanism, connect the iris cable to the Lens connector (EE/VSD S/W must be set to VSD on the side of the camera) A. In the case of having no iris amplifier : Set the slide switch to DC (Down side) B. In the case of having iris amplifier : Set the slide switch VSD (Upper side) C. Set the S/W on the side of the camera to DC or VSD, too.
If using lens that has iris amplifier, “LEVEL” and “ALC” volume of lens must be
adjust carefully. It may cause any hunting.
When connecting Auto iris lens, be sure to use the connector to be recommended
by manufacturer. (E4-191, Chuo Musen, Japan)
* Caution 1 : This appliance is set to CS mount default.
If you want to use C mount lens, fix a C adapter ring additionally packed in the box.
5
5
When Auto-Iris Lens is used...
VSD LENS PIN CONFIGURATION
3
1
1. POWER(12V) 2. NO CONNECTION
3. VIDEO SIGNAL 4. GND
4
2
Set the select switch to VSD
* For the best condition, read lens manual carefully . * After connecting Auto iris-lens you may need to set flange back focus.
DC IRIS LENS PIN CONFIGURATION
3
1
1. CONTROL- 2. CONTROL+
3. DRIVE+ 4. DRIVE-
4
2
Set the select switch to DC
Connection of AC power supply
Must be checked the power source from the external power supply before power on. Recommended power source capacity :
AC 24V, more than 500mA
6