CAUTION: EQUIPMENT DAMAGE
HAZARD. To prevent possible
compressor damage, do not operate
cooling system when outdoor
temperature is below 50°F (10°C).
1
Operating Manual
About your new thermostat
Congratulations on the purchase of your new Honeywell thermostat. It has been
designed to give you many years of reliable service and easy-to-use, push-button
climate control.
• One-touch temp control overrides program schedule at any time.
• EnergyStar® compliant to greatly reduce your heating/cooling expenses.
• Large, clear, backlit display is easy to read — even in the dark.
• Displays both room temperature and temperature setting.
• Removable battery holder for fast, easy replacement.
• Built-in compressor protection.
2
FocusPROTM TH6000 Series
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go. All you have to do is set
the time and day. Then check the settings below and change if needed:
1. Set time and day (required for proper operation) .........................See page 6
2. Select fan setting (Auto/On): Preset to Auto .................To change, see page 7
3. Select system setting (Heat/Cool): Preset to Heat ......To change, see page 8
4. Program schedules: Preset to energy-saving levels while you’re at work or
asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to
bed at 10 pm) ...............................................................To change, see pages 9-11
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and
manually adjust the temperature (see pages 12-13).
3
Operating Manual
Quick reference to controls
Digital display (see page 5).Battery holder (see page 17).
Temperature Buttons
Press to adjust temperature
settings (see page 11-13).
Hold Button
Press to override
programmed temperature
Function Buttons
Press to select the function displayed just above each
button. (Functions change depending on the task.)
4
control (see page 13).
Set Clock/Day/
Schedule
Auto
WakeWed
Fan
In Recovery
System
Auxiliary
Heat On
Heat
Heat
Setting
Inside
AM
72
72
6:30
Replace Battery
Quick reference to display screen
FocusPROTM TH6000 Series
Current inside temperature
In Recovery
(see page 16)
Current program period
Wake/Leave/Return/Sleep
(see pages 9-11)
Set Clock/Day/Schedule
(see pages 6 & 11)
Function buttons
Press the button beneath each function to
view or change settings (functions change
depending on the task)
Low battery warning
(see page 17)
5
Current time/day
(see page 6)
Temperature setting
(see pages 11-13)
Auxiliary heat
(Only for heat pumps
with auxiliary heat)
System status
Heat On/Cool On (If
flashing, see page 15)
System setting
Heat/Cool/Auto/Off/Em
Heat (see page 8)
Fan setting
Auto/On (see page 7)
Operating Manual
Set Clock/Day/
Schedule
Auto
FanSystem
Heat
PM
4:30
Done
Set DaySet Schedule
Wed
Set the time and day
Press SET CLOCK/DAY/SCHEDULE, then adjust time
Press SET DAY, then select current day
1. Press the SET CLOCK/DAY/SCHEDULE
button, then press sor tto set
the clock time.
2. Press the SET DAY button, then
press sor tto select the day
of the week.
3. Press DONE to save & exit.
Note: If the SET CLOCK/DAY/SCHEDULE
option is not displayed, press DONE or RUN SCHEDULE.
Note: If the display flashes Set Clock,
the thermostat will follow your settings
for the weekday “Wake” time period until
you reset the time and day.
6
Set Clock/Day/
Schedule
Auto
FanSystem
Heat
Set Clock/Day/
Schedule
On
FanSystem
Heat
Select the fan setting
FocusPROTM TH6000 Series
Press the FAN button to select Auto or On.
In “Auto” mode (the most commonly used
setting), the fan runs only when the heating
or cooling system is on. If set to “On,” the
fan runs continuously. Use this setting for
improved air circulation, or for more efficient
air cleaning.
7
Operating Manual
Set Clock/Day/
Schedule
Auto
FanSystem
Heat
Set Clock/Day/
Schedule
Auto
FanSystem
Cool
Select the system setting
Note: The Auto and Em Heat
system settings may not
appear, depending on how your
thermostat was installed.
Press the SYSTEM button to select:
• Heat: Thermostat controls only the
heating system.
• Cool: Thermostat controls only the
cooling system.
• Off: Heating and cooling systems are off.
• Auto: Thermostat automatically selects
heating or cooling depending on the
indoor temperature.
• Em Heat (only for heat pumps with
auxiliary heat): Thermostat controls
Emergency and Auxiliary Heat.
Compressor is locked out.
8
FocusPROTM TH6000 Series
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four
time periods each day, with different settings for weekdays and weekends.
WAKE
6:00 am
70
LEAVE
8:00 am
62
RETURN
6:00 pm
70
SLEEP
10:00 pm
62
Set to the time you awaken and the temperature you want during
the morning, until you leave for the day.
°
Set to the time you leave home and the temperature you want
while you are away (usually an energy-saving level).
°
Set to the time you return home and the temperature you want
during the evening, until bedtime.
°
Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
°
9
Operating Manual
EnergyStar® settings for maximum cost savings
This thermostat is pre-set to use EnergyStar® program settings. We recommend these
settings, since they can reduce your heating/cooling expenses by as much as 33%.
(See next page to adjust times and temperatures of each time period.)
1. Press SET CLOCK/DAY/SCHEDULE, then SET
SCHEDULE.
2. Press sor tto set your weekday Wake
time (Mon–Fri), then press NEXT.
3. Press sor tto set the temperature for this
time period, then press NEXT.
4. Set time and temperature for the next time
period (Leave). Repeat steps 2 and 3 for each
weekday time period.
5. Press NEXT to set weekend time periods (SatSun), then press DONE to save & exit.
Note: Make sure the thermostat is set to the system you
want to program (Heat or Cool).
Note: You can press CANCEL PERIOD to eliminate unwanted
time periods (except Wake).
11
Operating Manual
Run Schedule
Auto
FanSystem
Heat
Heat
Setting
Inside
AM
69
75
6:30
Temporary
Program schedule override (temporary)
Press to temporarily adjust temperature.
Press to cancel temporary setting and
resume program schedule.
Note: Make sure the thermostat is set
to the system you want to control (heat,
cool or auto).
Press sor tto immediately adjust
the temperature. This will temporarily
override the temperature setting for the
current time period.
The new temperature will be
maintained only until the next
programmed time period begins (see
page 10). For example, if you want to
turn up the heat early in the morning,
it will automatically be lowered later,
when you leave for the day.
To cancel the temporary setting at any
time, press RUN SCHEDULE.
12
Run Schedule
Auto
FanSystem
Heat
Heat
Setting
Inside
AM
69
75
6:30
Hold
Program schedule override (permanent)
FocusPROTM TH6000 Series
Press to permanently adjust temperature.
Press to cancel “Hold” setting and
resume program schedule.
Note: Make sure the thermostat is set
to the system you want to control (heat,
cool or auto).
Press HOLD to permanently adjust
the temperature. This will override
the temperature settings for all time
periods.
The “Hold” feature turns off the
program schedule and allows you to
adjust the thermostat manually, as
needed.
Whatever temperature you set will
be maintained 24 hours a day, until
you manually change it, or press RUNSCHEDULE to cancel “Hold” and resume
the programmed schedule.
13
Operating Manual
Set Clock/Day/
Schedule
Auto
FanSystem
Auto
Auto Changeover (heat/cool)
Press until screen
displays “Auto”
Note: The Auto system setting
may not appear, depending on
how your thermostat was installed.
Auto Changeover is a feature used in climates where both air conditioning and heating are used on the same day. When the system is set to Auto, the thermostat automatically selects heating or cooling depending on
the indoor temperature.
Heat and cool settings must be at least 3
degrees apart. The thermostat will automatically adjust settings to maintain this
3-degree separation (called “deadband”).
The 3-degree separation between heating
and cooling set temperatures is fixed, and
cannot be changed.
14
Set Clock/Day/
Schedule
Auto
FanSystem
Cool On
Cool
Cool
Setting
Inside
AM
75
75
6:30
Built-in compressor protection
Message flashes until safe restart
time has elapsed
FocusPROTM TH6000 Series
This feature helps prevent damage to the
compressor in your air conditioning or heat
pump system.
Damage can occur if the compressor is
restarted too soon after shutdown. This feature forces the compressor to wait for a few
minutes before restarting.
During the wait time, the display will flash
the message Cool On (or Heat On if you have
a heat pump). When the safe wait time has
elapsed, the message stops flashing and the
compressor turns on.
15