• F52F models are available with one electronic cell and
a rated capacity of 1000 cfm (1700 m
electronic cells and a rated capacity of 2000 cfm
(3400 m
• Electronic cell(s) can be washed in most automatic
dishwashers.
• Solid state power supply is energized by an airflow
switch; no interconnection to fan system is required.
• Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt-loading conditions.
• Pressure drop is approximately equal to that of a
regular fiberglass filter.
• Neon light shows that the air cleaner is operating.
• Automatic interlock switch disconnects the power
when unit is opened.
• Optional W8600F Air Cleaner Monitor indicates air
cleaner performance, informs owner when cell
washing is due and indicates need for system check.
3
/hr).
3
/hr), or two
APPLICATION
The F52F Return Grille Electronic Air Cleaner is wall or
ceiling mounted in the main return air duct of a central forced
air heating, cooling, or ventilation system. It captures a
significant number of the airborne particles (0.5 microns and
larger) from the air circulated through the cell(s).
Parts List ........................................................................... 18
X-XX UL
68-0074-9
F52F RETURN GRILLE ELECTRONIC AIR CLEANER
SPECIFICATIONS
IMPORTANT
Models:
Electrical Ratings:
Capacity, Efficiency, Pressure Drop:
See Fig. 1.
Temperature Ratings:
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed
specifications. Also, this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be
expected if those conditions are changed.
F52F Return Grille Electronic Air Cleaner (one-cell model
for up to 1000 cfm [1700 m
power supply with air cleaner monitor capability, one
electronic cell, prefilter, door/grille and airflow switch.
F52F Return Grille Electronic Air Cleaner (two-cell model
for up to 2000 cfm [3400 m
power supply with air cleaner monitor capability, two
electronic cells, prefilter, door/grille and airflow switch.
Maximum Current (A)
No. of
Cells
120 x 12.50.40.222
220 x 250.40.236
Operating Ambient: 40°F to 125°F (4°C to 52°C).
Temperature of Airflow Through Cell(s): 40°F to 125°F
System
Size (in.)
(4°C to 52°C).
120V,
60 Hz
3
/hr]). Includes solid state
3
/hr]). Includes solid state
220/240V,
50/60 Hz
Maximum
Power (W)
Maximum Cell Washing Temperature: 220°F (104°C).
Storage and Shipping (Entire Unit): minus 40°F to
plus 140°F (minus 40°C to plus 60°C).
Mounting:
Recesses into duct opening on wall or ceiling. On wall
installation, mount with hinge on bottom or either side (see
Review Installation Requirements section). Not intended for
floor installations.
Weight:
F52F Electronic Air
Cleaner
Shipped39.217.858.826.7
Installed29.413.445.320.6
Cell(s)—included in
above weights
Dimensions:
See Fig. 2 and 3.
Door/Grille Type:
Egg crate.
Cell Size:
12-1/2 x 20 in. (318 x 508 mm).
Underwriters Laboratories Inc. Listed:
File No. E30954, Guide No. AGGZ.
Canadian Standards Association Listed:
File No. LR19060-L.
Accessories and Replacement Parts:
See Fig. 23.
1-Cell2-Cell
lbkglbkg
9.54.39.5
ea
4.3
ea
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number, or specify:
1. Order number.4. Type of door/grille—louvered or egg crate.
2. Voltage and frequency.5. Accessories, if desired.
3. Dimensions: 20 x 25 or 20 x 12-1/2 in.6. W8600F Air Cleaner Monitor, if desired.
(508 x 635 or 508 x 318 mm).Specify beige or white color.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.Home and Building Control Customer Logistics
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 2C9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0074—9
2
F52F RETURN GRILLE ELECTRONIC AIR CLEANER
.25 (62)
900
.20 (50)
.15 (37)
.10 (25)
.05 (13)
0 (0)
1000
(1700)
3
PRESSURE DROP IN IN. WC (PA)
1
100
90
80
70
EFFICIENCY, PERCENT
60
50
500
400
(850)
(680)
F52F ONE CELL CAPACITY IN cfm (m /hr)
1 EFFICIENCY RATINGS BASED ON NATIONAL BUREAU OF STANDARDS DUST SPOT METHOD USING ATMOSPHERIC DUST
AND AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR-CONDITIONING ENGINEERS STANDARD 52.1-92.
600
(1020)
700
(1190)
800
(1360)
(1530)
1
100
90
80
70
EFFICIENCY, PERCENT
60
50
1000
1200
800
(1700)
(1360)
F52F TWO CELL CAPACITY IN cfm (m /hr)
(2040)
1400
(2350)
1600
(2720)
1800
(3060)
Fig. 1. Air cleaner efficiency and pressure drop at various airflow rates.
1-1/8 (29)
12-7/8
(327)
KNOCKOUT FOR 1/2 INCH
CONDUIT CONNECTOR
ON BOTTOM OF F52
1-3/8 (35)
7
(178)
.25 (62)
.20 (50)
.15 (37)
.10 (25)
.05 (13)
0 (0)
2000
(3400)
3
PRESSURE DROP IN IN. WC (PA)
M7824
15-3/4 (400)
11/16
(18)
1-1/4
(32)
28
(711)
3/16
(5)
(7)
1-3/16
(30)
3/4 (19)
3-11/16
(94)
11-3/16
(284)
17-7/8
(454)
26
(660)
1-1/8 (29)
KNOCKOUT FOR 1/2 INCH
CONDUIT CONNECTOR
ON BACK OF F52
M11983
Fig. 2. Approximate installation dimensions in in. (mm) of one-cell F52F Electronic Air Cleaner.
68-0074—93
F52F RETURN GRILLE ELECTRONIC AIR CLEANER
23-1/8
(587)
29-1/16 (738)
17-5/16
(440)
31 (787)
11-1/2
(292)
5-5/8
(143)
3/16 (5)
(8)
13/16 (21)
11/16 (18)
24
(610)
2-1/2 (64)
1-1/2 (38)
1-1/4
10-3/4
(273)
3/16
(5)
(7)
A
(32)
7 (178)
4-1/16
(103)
8-1/16
(205)
13-5/8
(346)
22
(559)
1-1/2
(38)
3/4
(19)
KNOCKOUT FOR 1/2 INCH CONDUIT
CONNECTOR ON BACK OF F52
Fig. 3. Approximate installation dimensions in in. (mm) of two-cell F52F Electronic Air Cleaner.
PLANNING THE INSTALLATION
Application and Construction
The air cleaner should be installed in the occupied space
return duct opening leading to a central air handling system.
All of the air circulated by the system must pass through the
electronic air cleaner.
The front door of the electronic air cleaner is hinged to
provide access to the internal components. See Fig. 4.
The air cleaner has one or two electronic cell(s) that must be
installed with the ionizer section (side with fine wires) facing
the door.
17-11/16
(449)
3/4 (19)
7/8 (22)
3-3/8
(86)
KNOCKOUT FOR
1/2 INCH CONDUIT
CONNECTOR
M11984
The cell(s) is held in place by metal hooks and a
quarter-turn latch.
A spring contact provides the electrical connection between
the solid state power supply and the electronic cell(s). An
interlock switch interrupts the line voltage to the power supply
when the door is opened. A rocker-type ON-OFF switch
allows the air cleaner to be turned off manually. An indicator
light that is on shows that the air cleaner is energized and the
power supply is producing high voltage.
68-0074—9
4
F52F RETURN GRILLE ELECTRONIC AIR CLEANER
M11985
METAL MESH
PREFILTER
INTERLOCK SWITCH
ONE-CELL MODEL
CELL HOOKS
ON-OFF
SWITCH
POWER SUPPLY
ENCLOSURE
ELECTRONIC
CELL
CELL
LATCH
ON-OFF
SWITCH
INTERLOCK
SWITCH
CELL
CONTACT
PLATE
HINGE
HINGE
TWO-CELL MODEL
POWER SUPPLY
ENCLOSURE
DOOR
CELL HOOKS
CELL LATCH
CELL CONTACT
PLATE
ELECTRONIC CELL
METAL MESH
PREFILTER
DOOR
M7820A
Fig. 4. Internal components of F52F Electronic Air Cleaner.
Review Installation Requirements
The air cleaner is installed in place of the main return grille
so all the air circulated by the system passes through the
air cleaner.
It can be installed in either a wall or ceiling, but not in the
floor. See Fig. 5 through 7 for typical installations.
AIRFLOW
UPFLOW
FURNACE
RETURN GRILLE
ELECTRONIC AIR
CLEANER
AIRFLOW
M7809
Fig. 5. Typical electronic air cleaner application
on platform-mounted upflow furnace.
(Dotted lines show optional ductwork.)
Fig. 6. Typical electronic air cleaner installation on
an upflow furnace.
68-0074—95
F52F RETURN GRILLE ELECTRONIC AIR CLEANER
RETURN
GRILLE
ELECTRONIC
AIR CLEANER
COUNTERFLOW
FURNACE
Fig. 7. Typical electronic air cleaner application on counterflow (downflow) furnace.
(Dotted lines show optional ductwork.)
In a wall installation, mount the one-cell air cleaner with the
door hinge on the bottom so the air cleaner fits between the
two studs 16 in. (407 mm) on center. The two-cell air cleaner
fits between two studs 24 in. (610 mm) on center when
mounted with the hinge on either side
or
between three 16 in.
studs, with center stud removed, when mounted with hinge on
the bottom.
Do not install either unit with the hinge on the top because the
cell(s) will be awkward to remove.
Determine Duct Design Requirements
The return duct should end at, or slightly behind, the finished
wall surface. Do not use a standard register flange, or the
door may not fit tightly against the wall.
Transitions
Transitions are needed when the duct is a different size than
the air cleaner. Gradual transitions reduce air turbulence and
increase efficiency. The transition should be 20 degrees or
about 4 in. per running ft (100 mm per 300 linear mm) or less
on each side of a transition fitting.
INSTALLATION
When Installing this Product…
1. Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
RETURN GRILLE
ELECTRONIC
AIR CLEANER
AIRFLOW
M7810
CAUTION
Electric Shock Hazard.
Can cause electrical shock or equipment damage.
Disconnect power before installing air cleaner.
Unpack the Air Cleaner
1. Check that all components are included. The unit
consists of:
• Door assembly in separate box.
• One metal mesh prefilter.
• One or two electronic cell(s).
• Literature package.
2. Lift out and set aside the door/grille assembly and the
prefilter. Turn the cell latch (Fig. 4) toward the air
cleaner cabinet and remove the electronic cell(s), lifting
from the side nearest the latch. Set aside.
3. Remove the four screws holding the wiring
compartment cover.
4. Remove the air cleaner cabinet from the carton.
Make Wall Opening
1. Size the wall opening to fit the air cleaner as closely as
possible with the air cleaner door hinge on either side
or bottom for the two-cell model, and on the bottom for
the one-cell model. See Table 1 for dimensions.
Table 1. Installation Dimensions.
Wall Stud SpacingUnit Dimensions
Modelin.mmin.mm
1-cell1640612-7/8 x
2-cell24 or 32 610 or 81329-1/16 x 22 738 x 559
25-15/16
327 x 659
68-0074—9