Honeywell F150e1034, F150e1026, F150e1000, F150e1018, F150e Owner's Manual

...
F150E
whole-house air quality system
F150E
W8600A
AIRWATCH™
Media Air Cleaner
PRODUCT DATA

FEATURES

• W8600A AIRWATCH filter change indicator.
• High efficiency media filter captures particles as small as 0.3 micron.
• Efficiency ratings based on the American Society of Heating, Refrigerating and Air Conditioning Engineers Standard 52.2-1999.
• Applicable to all gas, oil, and electric forced warm air furnaces and to compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Cabinet can support weight of residential furnace and evaporator coil.
• Requires no electrical connections.
• Mounts in any position.
• Requires no maintenance except periodic media filter replacement.
• Quick and easy media filter replacement.
• Later upgrade to higher performing Honeywell media or electronic air cleaner is easy.

APPLICATION

® U.S. Registered Trademark © 2004 Honeywell International Inc. All Rights Reserved
Contents
Application.........................................................................1
Features ............................................................................1
Specifications ....................................................................2
Ordering Information .........................................................2
Planning the Installation ....................................................3
Installation ........................................................................6
Checkout ...........................................................................7
68-0245EF-3
F150E MEDIA AIR CLEANER

SPECIFICATIONS

IMPORTANT
The specifications in this publication do not include normal manufacturing tolerances; therefore, an individual unit may not exactly match the listed specifications. This product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.
Model:
F150E Media Air Cleaner includes cabinet, access door and
pleated media filter, and W8600A AirWatch™ Indicator.
Application:
Use with gas, oil, and electric forced warm air furnaces and
with compressor cooling. Can be used with heat pumps if filter is changed regularly to prevent excessive pressure drop. Not recommended for applications where pressure drop may be critical.
Pressure Drop:
Initial pressure drop at 492 fpm: 0.23 in. wc. Dust fed to 0.5 in. wc pressure drop: 72 grams.
Efficiency:
Efficiency Ratings: Based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Minimum Efficiency Reporting Valve (MERV): 10 at 492 fpm.
Filter Media:
Pleated for greater media capacity.
Capacity And Pressure Drop:
See Fig 2. Initial Pressure Drop: 0.23 in. wc at 492 fpm.
Temperature Rating:
-40° to +140°F (-40° to +60°C).
Dimensions:
See Fig. 1.
Mounting:
Mounts in any position in the return air duct, usually next to
the furnace blower compartment. Cabinet is sturdy enough to support weight of a residential furnace and evaporator coil.Underwriters Laboratories, Inc.:
Listed to UL 900, Class 2.
Included Accessory:
W8600A AirWatch™ Indicator.
Upgrade Path:
The F150E uses the same cabinet as the F300E Electronic
Air Cleaner. Upgrade may require installing the cell key, electronic cells, protective screens and installation and wiring of the power box, depending on model.
Initial Efficiency*:
Replacement Media:
For optimum system performance, replace the filter every six
INITIAL EFFICIENCY* :
85.1%
61.8%
24.8%
% EFFICIENCY
0.3 - 1.01.0 - 3.03.0 - 10.0
% EFFICIENCY
*LMS Technologies Inc. Fractional Efficiency Testing FC100, 2004.
months (before heating season and before cooling season). Adjust the schedule to you needs, but replace the filter at least annually.
Filter Size (in.) Part Number
16 x 25 FC100A1029 16 x 20 FC100A1003 20 x 25 FC100A1037 20 x 20 FC100A1011
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0245EF-3 2
F150E MEDIA AIR CLEANER
1
(29)
1
8
6
(172)
DIM. A
(SEE TABLE)
7
3 4
F150E SIZE
IN.
16 X 25 20 X 25 16 X 20 20 X 20
8
(22)
MM 406 X 635 508 X 635 406 X 508 508 X 508
5 8
(16)
DIM. A
IN. MM IN. MM
14-7/16 18-7/16 14-7/16 18-7/16
367 468 367 468
16-3/16 20-3/16 16-3/16 20-3/16
DIM. B
DIM. C (SEE TABLE)
DIM. D (SEE TABLE)
411
23-1/4
513
23-1/4
411
18-1/4
513
18-1/4
DIM. C
IN. MM IN.
591
25-1/2
591
25-1/2
457
20-1/2
457
20-1/2
DIM. D
MM 648
648 521 521
DIM. B
(SEE TABLE)
7 8
(22)
M22578
Fig. 1. Installation dimensions in in. (mm) of air cleaner.
FILTER SIZE
20 X 25 16 X 25 20 X 20
0.300
1
0.250
0.200
0.150
0.100
0.050
PRESSURE DROP (IN. WC)
0.000
0
WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER
1
BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP REACHES 0.5 IN. WC. (0.1 kPa).
16 X 20
500 1000 1500
AIRFLOW (CFM)
Fig. 2. Capacity, Pressure Drop and Area of
F150E Filter Media.

PLANNING THE INSTALLATION

Location

The media air cleaner should be installed where all the air passing through the system is circulated through it. The best location is in the return air duct next to the blower compart­ment so the media air cleaner can help to keep the blower motor and evaporator coils clean. Do not mount in the supply air duct.
For most efficient air cleaning, spread airflow evenly across the face of the media. If the duct is a different size than the media air filter cabinet, gradual transitions are required. If the duct turns sharply just before the air filter, turning vanes are
2000
M14709A
required.
Choose a location that is readily accessible for checking and replacing the filter. Allow at least 26 in. (660 mm) clearance in front of the unit for removal of the cartridge.
Install the media air filter where the temperature will not exceed the ratings in the Specifications.
3 68-0245EF-3
F150E MEDIA AIR CLEANER
A

Applications With Air Conditioning

Mount the media air cleaner upstream of the evaporator coil in a cooling system. The filter will help to keep the coil clean and reduce maintenance.

Applications With A Humidifier

The media air cleaner is compatible with humidifiers. Avoid applications where water mist will reach the media. If an atomizing humidifier is used, the filter media will require replacement more often because of minerals in the water.

Choose Mounting Position

The media air cleaner can be mounted in any position, but the arrow on the cartridge must point in the same direction as the airflow. See Figs. 3-10 for proper location of the media air cleaner for a variety of furnace installations. Note that the media air cleaner cabinet is sturdy enough to easily support the weight of the furnace and evaporator coil. See Fig. 4.
M940
Fig. 4. Highboy furnace, with installation beneath furnace.
Media air cleaner is mounted horizontally where return
enters from below.
M939A
Fig. 3. Highboy furnace, with side installation.
Media air filter is mounted vertically where return
enters side inlet of furnace.
68-0245EF-3 4
M941A
Fig. 5. Highboy furnace, with closet installation. Media air cleaner is mounted vertically on furnace between furnace
and louvered return air opening in closet door.
M942A
F150E MEDIA AIR CLEANER
Fig. 6. Lowboy furnace, with media air cleaner mounted
horizontally in return plenum just above furnace and
opposite heating plenum.
M944A
Fig. 8. Central fan installation, with media air cleaner
mounted horizontally in central return duct.
M945A
Fig. 9. Horizontal furnace, with media air filter mounted
vertically in return duct near furnace.
M943A
Fig. 7. Counterflow furnace, with media air cleaner mounted horizontally in return duct or plenum just
above furnace.
M946A
Fig. 10. Two or more media air cleaners used in a high
capacity system.